Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Southwest Research Institute assistance to NASA in biomedical areas of the technology

Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

Culclasure, D. F.↗

Densitography - A new method for evaluation of cardiac performance of rest and during exercise.

The validity of the densitographic curves obtained from the pinna of the ear for measuring the systolic intervals has been investigated in 28 subjects. This technique is found to permit the performance of noninvasive physiologic studies during physical activities, exercise tests, flight conditions, and probably long-term monitoring of critically ill patients. Densitographic curves constitute an excellent substitute by which to measure time-base intervals of the cardiac cycle when the carotid pulse tracing is not available.

Chirife, R.↗

Cardiovascular responses to glucagon - Physiologic measurement by external recordings.

Assessment by noninvasive polygraphic techniques of the cardiovascular responses of normal subjects to intravenous injections of glucagon and glucagon diluent. A blinding procedure which eliminated observer bias was used during the reading of tracings. Analysis of group results showed that glucagon provoked uniformly significant changes, including increase in heart rate, blood pressure, pressure-rate product, and ejection time index, and decrease in prejection period, mechanical and electromechanical systole, left ventricular ejection time, and the ratio PEP/LVET. The principal results correlated well with those of previous studies of the hemodynamic effects of glucagon.

Byrne, M. J.↗

A study of ventricular contractility and other parameters possibly related to vasodepressor syncope

The effects of diminished orthostatic and exercise tolerance resulting from prolonged bedrest were studied by noninvasion methods to determine if alterations in myocardial contractility were induced by bedrest. These methods were apexcardiography, systolic time intervals, and echocardiography. It is concluded that bedrest causes detrimental alterations in the contractile state of the myocardium which accounts for the decreases in maximal oxygen uptaken during exercise after bedrest. Tabulated test data are included.

Hyatt, K. H.↗

Quantitative values of blood flow through the human forearm, hand, and finger as functions of temperature

A literature search was made to obtain values of human forearm, hand and finger blood flow as functions of environmental temperature. The sources used include both government and laboratory reports and the research presented in the open literature. An attempt was made to review many of the more quantitative noninvasive determinations and to collate the results in such a way as to yield blood flow values for each body segment as continuous functions of temperature. A brief review of the various ways used to measure blood flow is included along with an abstract of each work from which data was taken.

Montgomery, L. D.↗

Apparatus and method for processing Korotkov sounds

A Korotkov sound processor, used in a noninvasive automatic blood measuring system where the brachial artery is occluded by an inflatable cuff, is disclosed. The Korotkoff sound associated with the systolic event is determined when the ratio of the absolute value of a voltage signal, representing Korotkov sounds in the range of 18 to 26 Hz to a maximum absolute peak value of the unfiltered signals, first equals or exceeds a value of 0.45. Korotkov sound associated with the diastolic event is determined when a ratio of the voltage signal of the Korotkov sounds in the range of 40 to 60 Hz to the absolute peak value of such signals within a single measurement cycle first falls below a value of 0.17. The processor signals the occurrence of the systolic and diastolic events and these signals can be used to control a recorder to record pressure values for these events.

Golden, D. P., Jr.↗

Advance techniques for monitoring human tolerance to positive Gz accelerations

Tolerance to positive g accelerations was measured in ten normal male subjects using both standard and advanced techniques. In addition to routine electrocardiogram, heart rate, respiratory rate, and infrared television, monitoring techniques during acceleration exposure included measurement of peripheral vision loss, noninvasive temporal, brachial, and/or radial arterial blood flow, and automatic measurement of indirect systolic and diastolic blood pressure at 60-sec intervals. Although brachial and radial arterial flow measurements reflected significant cardiovascular changes during and after acceleration, they were inconsistent indices of the onset of grayout or blackout. Temporal arterial blood flow, however, showed a high correlation with subjective peripheral light loss.

Pelligra, R.↗

Cardiac mechanics: Physiological, clinical, and mathematical considerations

Recent studies concerning the basic physiological and biochemical principles underlying cardiac muscle contraction, methods for the assessment of cardiac function in the clinical situation, and mathematical approaches to cardiac mechanics are presented. Some of the topics covered include: cardiac ultrastructure and function in the normal and failing heart, myocardial energetics, clinical applications of angiocardiography, use of echocardiography for evaluating cardiac performance, systolic time intervals in the noninvasive assessment of left ventricular performance in man, evaluation of passive elastic stiffness for the left ventricle and isolated heart muscle, a conceptual model of myocardial infarction and cardiogenic shock, application of Huxley's sliding-filament theory to the mechanics of normal and hypertrophied cardiac muscle, and a rheological modeling of the intact left ventricle. Individual items are announced in this issue.

Mirsky, I.↗

Cardiovascular effects of variations in habitual levels of physical activity

Mechanisms involved in human cardiovascular adaption to stress, particularly adaption to different levels of physical activity are determined along with quantitative noninvasive methods for evaluation of cardiovascular function during stess in normal subjects and in individuals with latent or manifest cardiovascular disease. Results are summarized.

Blomqvist, C. G.↗

The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

Laing, R. A.↗

Biomedical ultrasonoscope

Portable, battery-powered device permits noninvasive examination of body's interior and is particularly well suited to real-time examination of heart. Instrument is capable of C-mode, A-mode, and M-mode scan display.

Lee, R. D.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems

The following projects involving cardiovascular instrumentation were conducted: (1) the development and fabrication of a three-dimensional display measurement system for vectorcardiograms, (2) the development and fabrication of a cardiovascular monitoring system to noninvasively monitor beat-by-beat the blood pressure and heart rate using aortic pulse wave velocity, (3) the development of software for an interactive system to analyze systolic time interval data, and (4) the development of microprocessor-based physiologic instrumentation, focussing initially on EKG rhythm analysis. Brief descriptions of these projects were given.

Mark, R. G.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2

The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.

Mark, R. G.↗

Effects of water immersion to the neck on pulmonary circulation and tissue volume in man

A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.

Begin, R.↗

An objective determination of /+/G-sub z acceleration tolerance

The paper describes a method for objective determination of (+)G-sub z (head-to-foot) acceleration tolerance. Using noninvasive instrumentation based on a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from backscattered ultrasound. Over 100 subjects have been studied during more than 2000 centrifuge runs

Sandler, H.↗

Applications of Doppler ultrasound in clinical vascular disease

Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

Barnes, R. W.↗

Systolic time interval data acquisition system. Specialized cardiovascular studies

The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

Baker, J. T.↗

Evaluation of the electromechanical properties of the cardiovascular system after prolonged weightlessness

Devices and techniques for measuring and analyzing systolic time intervals and quantitative phonocardiograms were initiated during Apollo 17. The data show that the systolic time interval from Apollo 17 crewmen remained elevated longer postflight than the response criteria of heart rate, blood pressure, and percent change in leg volume all of which had returned to preflight levels by the second day postflight. Although the systolic time interval values were only slightly outside the preflight fiducial limits, this finding suggested that: the analysis of systolic time intervals may help to identify the mechanisms of postflight orthostatic intolerance by virtue of measuring ventricular function more directly and, the noninvasive technique may prove useful in determining the extent and duration of cardiovascular instability after long duration space flight. The systolic time intervals obtained on the Apollo 17 crewmen during lower body negative pressure were similar to those noted in patients with significant heart disease.

Bergman, S. A., Jr.↗