Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗

Flexible organic integrated electronics for self-powered multiplexed ocular monitoring

Smart contact lens has drawn extensive research interests due to the noninvasive real-time detection of the human body to provide biomedical information for health management. However, it has been difficult to accurately measure the physiological signals in tears, and the use of external power source has also hindered the future applications. Here, we demonstrated an organic electrochemical transistor based multiplexed sensors self-powered by the organic solar cells (OSCs). The integrated device was fabricated via simple process including solution blade-coating and thermal evaporation. OSCs were optimized to provide optimal operation voltage for the sensors that exhibit semilog-linear response to the glucose and calcium ions in tear fluids without any peripheral circuits. The sensing signals can be transmitted to the laptop wirelessly through a near filed communication unit. This integrated self-powered multiplexed sensing device will provide real-time monitoring of the biomarkers in tears, prospected to be installed on the smart contact lens for the early detection and diagnosis of diabetes.

36 MATERIALS SCIENCE↗

Functional and transcriptional characterization of complex neuronal co-cultures

Brain-on-a-chip systems are designed to simulate brain activity using traditional in vitro cell culture on an engineered platform. It is a noninvasive tool to screen new drugs, evaluate toxicants, and elucidate disease mechanisms. However, successful recapitulation of brain function on these systems is dependent on the complexity of the cell culture. In this study, we increased cellular complexity of traditional (simple) neuronal cultures by co-culturing with astrocytes and oligodendrocyte precursor cells (complex culture). We evaluated and compared neuronal activity (e.g., network formation and maturation), cellular composition in long-term culture, and the transcriptome of the two cultures. Compared to simple cultures, neurons from complex co-cultures exhibited earlier synapse and network development and maturation, which was supported by localized synaptophysin expression, up-regulation of genes involved in mature neuronal processes, and synchronized neural network activity. Also, mature oligodendrocytes and reactive astrocytes were only detected in complex cultures upon transcriptomic analysis of age-matched cultures. Functionally, the GABA antagonist bicuculline had a greater influence on bursting activity in complex versus simple cultures. Collectively, the cellular complexity of brain-on-a-chip systems intrinsically develops cell type-specific phenotypes relevant to the brain while accelerating the maturation of neuronal networks, important features underdeveloped in traditional cultures.

59 BASIC BIOLOGICAL SCIENCES↗

Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate. Here, we present a technique to overcome such limitations. Employing a machine learning (ML) strategy, we can accurately predict electron beam properties for every shot using only parameters that are easily recorded at high repetition rate by the detector while the experiments are ongoing, by training a model on a small set of fully diagnosed bunches. Applying ML as real-time noninvasive diagnostics could enable some new capabilities, e.g., online optimization of the long-term stability and fine single-shot quality of the electron beam, filtering the events and making online corrections of the data for time-resolved UED, otherwise impossible. This opens the possibility of fully realizing the potential of high repetition rate UED and UEM for life science and condensed matter physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Computational investigations of Dienes defect- and vacancy-induced changes in the electronic and vibrational properties of carbon fiber structural units

Carbon fiber (CF) is a promising lightweight alternative to steel and is of significant interest for energy applications. As CF continues to find new uses and is exposed to new external conditions, a noninvasive method of monitoring its structural integrity is critical. Raman spectroscopy is a commonly used method for this monitoring; however, it is highly inferential, and the interpretation of the data is not always straightforward. In this work, we perform density functional theory (DFT) calculations to investigate changes in the vibrational properties of CF structural units (i.e., graphene and graphite) caused by monovacancy and Dienes defects as a foundation for modeling more complex defects that move our model toward that of realistic CF. Using large computational supercells, we can understand how these defects change the electronic structure and vibrational properties of graphene and graphite for interdefect distances near those of the lower experimental limit. The monovacancy opens an electronic bandgap at the K point. Although no such electronic gap is opened by the Dienes defect, both defects introduce flat defect bands near the Fermi energy. The Dienes defect creates long-range deviations of the phonons, leading to substantial broadening of the highest frequency optical modes in the band structure compared to that of the pristine material. In contrast, the phonon changes caused by the monovacancy are short range, and only minor changes in the band structure or phonon density of states were observed. These findings can assist in the interpretation of experimental results by providing atomic-scale insight into key electronic and vibrational features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proteomic and metabolomic profiling of acute and chronic stress events associated with military exercises

By characterizing physiological changes that occur in warfighters during simulated combat, we can start to unravel the key biomolecular components that are linked to physical and cognitive performance. Viable field-based sensors for the warfighter must be rapid and noninvasive. In an effort to facilitate this, we applied a multiomics pipeline to characterize the stress response in the saliva of warfighters to correlate biomolecular changes with overall performance and health. In this study, two different stress models were observed – one of chronic stress and one of acute stress. In both models, significant perturbations in the immune, metabolic, and protein manufacturing/processing systems were observed. However, when differentiating between stress models, specific metabolites associated with the “fight or flight” response and protein folding were seen to be discriminate of the acute stress model.

60 APPLIED LIFE SCIENCES↗

Remote sensing of Pu in uranyl nitrate crystals using reflectance spectroscopy and chemometrics

Remote quantification of Pu(VI) (0–5 mol%) co-crystallized with U in uranyl nitrate hexahydrate (UNH) crystals was achieved in a glove box using reflectance spectroscopy coupled with chemometric modeling. Reflectance spectra were also acquired for Pu(IV) and Np(VI) (0–5 mol%) crystallized with UNH; revealing spectral features consistent with their solution-phase analogs. Principal component analysis revealed Pu(IV/VI) and Np(VI) concentrations as the primary source of variation in the data, informing the development of a supervised partial least squares regression model for Pu(VI). The resulting calibration demonstrated robust performance, with replicate root mean square errors near 10% and quantifiable limits near 0.2 mol% Pu(VI) relative to U. The Pu(VI) remained stable in the crystalline UNH matrix for at least one week with minimal reduction to Pu(IV). Notably, Pu(VI) and Np(VI) incorporation in UNH quenched U(VI) fluorescence while Pu(IV) did not. This study presents a noninvasive, spectroscopic approach for solid-state Pu quantification, with direct implications for material accountability and nuclear nonproliferation monitoring.

Sadergaski, Luke R. [Oak Ridge National Laboratory↗

Anisotropic index of refraction and structural properties of hexagonal boron nitride epilayers probed by spectroscopic ellipsometry

The anisotropic index of refraction of 200 μm thick boron-10 enriched hexagonal boron nitride (h-BN) freestanding epilayers grown by metalorganic chemical vapor deposition has been measured using spectroscopic ellipsometry in the UV (4.0–5.1 eV) spectral range. It was found that the index of refraction for the polarization mode with an electric field perpendicular to the c-axis (ordinary, n o ) is much higher than that with an electric field parallel to the c-axis (extraordinary, n e ). By inclusion of turbostratic- (t-) phase layers within h-BN having an average inclination angle (θ) with respect to the ideal c-plane, a simple method for quantifying θ has been deduced. Our results revealed that the presence of t-phase layers decreases the optical anisotropy of h-BN and that a signature of improved crystalline quality is an increase in the ordinary index of refraction (n o ) as a result of the average incline angle θ approaching 0° and predicted that n o = 2.7 and n e = 1.5 at 280 nm for single crystalline h-BN epilayers. More importantly, our results demonstrated that spectroscopic ellipsometry is an effective technique for characterizing the crystalline quality of h-BN epilayers with the advantages of being noninvasive and highly sensitive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of ion velocity distributions in a large scale laser-produced plasma

Laser-produced plasma velocity distributions are an important, but difficult quantity to measure. In this work, we present a noninvasive technique for measuring individual charge state velocity distributions of laser-produced plasmas using a high temporal and spectral resolution monochromator. The novel application of this technique is its ability to detect particles up to seven meters from their inception (significantly larger than most laboratory plasma astrophysics experiments, which take place at or below the millimeter scale). The design and assembly of this diagnostic is discussed in terms of maximizing the signal to noise ratio, maximizing the spatial and temporal resolution, and other potential use cases. The analysis and results of this diagnostic are demonstrated by directly measuring the time-of-flight velocity of all ion charge states in a laser produced carbon plasma.

47 OTHER INSTRUMENTATION↗

Reconstructions from randomly generated longitudinal electron bunch profiles with Gaussian envelopes using the Gerchberg–Saxton algorithm

Knowledge of longitudinal electron bunch profiles is vital to optimize the performance of plasma wakefield accelerators and x-ray free electron laser linacs. Because of their importance to these novel applications, noninvasive frequency domain techniques are often employed to reconstruct longitudinal bunch profiles from coherent synchrotron, transition, or undulator radiation measurements. In this paper, we detail several common reconstruction techniques involving the Kramers–Kronig phase relationship and Gerchberg–Saxton algorithm. Additionally, through statistical analysis, we draw general conclusions about the accuracy of these reconstruction techniques and the most suitable candidate for reconstructing well-isolated longitudinal bunch profiles from spectroscopic data.

47 OTHER INSTRUMENTATION↗

Time-resolved broadband impulsive stimulated Brillouin scattering in single crystal hematite

Impulsive stimulated Brillouin scattering (ISBS) has emerged as a noninvasive means to determine the elastic properties of transparent materials. Here, we report on time-resolved broadband ISBS reflectivity measurements in single crystal hematite, α-Fe 2 O 3 . We found that the observed transient reflectivity changes are best described by the known strain propagation model (SPM) and introduced a simple derivation of the ISBS-SPM formula based on ray tracing, which accounts for the presence of the interface. Additionally, measurements at different incident probe beam angles illustrate a plausible approach toward determining the speed of sound in transparent media without any prior knowledge of their dielectric properties and vice versa.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Toward implementing autonomous adaptive data acquisition for scanning hyperspectral imaging of biological systems

Autonomous experimentation is an emerging area of research, primarily related to autonomous vehicles, scientific combinatorial discovery approaches in materials science and drug discovery, and iterative research loops of planning, experimentation, and analysis. However, autonomous approaches developed in these contexts are difficult to apply to high-dimensional mapping technologies, such as scanning hyperspectral imaging of biological systems, due to sample complexity and heterogeneity. We briefly cover the history of adaptive sampling algorithms and surrogate modeling in order to define autonomous adaptive data acquisition as an objective-based, flexible building block for future biological imaging experimentation driven by intelligent infrastructure. We subsequently summarize the recent implementations of autonomous adaptive data acquisition (AADA) for scanning hyperspectral imaging, assess how these address the difficulties of autonomous approaches in hyperspectral imaging, and highlight the AADA design variation from a goal-oriented perspective. Finally, we present a modular AADA architecture that embeds AADA-driven flexible building blocks to address the challenge of time resolution for high-dimensional scanning hyperspectral imaging of nonequilibrium dynamical systems. In our example research-driven experimental design case, we propose an AADA infrastructure for time-resolved, noninvasive, and label-free scanning hyperspectral imaging of living biological systems. This AADA infrastructure can accurately target the correct state of the system for experimental workflows that utilize subsequent expensive, high-information-content analytical techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electron beam characterization via quantum coherent optical magnetometry

We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturbs the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size, and total current. We tested this method for an e-beam with currents ranging from 30 to 110 μA. Our approach is insensitive to electron kinetic energy, and we confirmed that experimentally between 10 and 20 keV. In conclusion, this technique offers a unique platform for noninvasive characterization of charged particle beams used in accelerators for particle and nuclear physics research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Terahertz near-field imaging of sidewall-induced losses in superconducting qubits

Correlating superconducting qubit performance with advanced materials analysis is a key strategy for improving coherence. Existing diagnostics for key properties, such as dielectric loss, structural discontinuity, and interface heterogeneity, often rely on destructive electron microscopy or low-throughput millikelvin measurements. Here, in this study, we demonstrate noninvasive terahertz (THz) nano-imaging/spectroscopy of encapsulated niobium transmon qubits as a high-throughput proxy for performance evaluation. We identify large variations in sidewall near-field signals, implicating sidewall loss and discontinuity as major coherence limiters, and also use THz hyperspectral line scans to probe dielectric responses and field participation at Al junction interfaces.

Kim, Richard H. J. [Ames Laboratory (AMES), Ames, ↗

Operando measurement of lattice strain in internal combustion engine components by neutron diffraction

Significance Internal combustion engine components experience extreme thermomechanical cycling during operation, and the continuing need to improve engine efficiency while maintaining or improving reliability drives the development of lightweight materials with improved thermal and mechanical integrity. Understanding the behavior of new materials in dynamic operation requires operando characterization tools, but conventional in situ measurements of material behavior during real engine operation are very limited, and no practical means exist to replicate such extreme dynamics for ex situ study. In this work, we demonstrate that the penetrating power of neutrons can provide noninvasive measurement of lattice strains inside components of a firing engine, enabling the operando study of complex load states and thermal gradients throughout the solid materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗