Search NASA⌕ Search

SEARCH · Search NASA

Results for “novel apparatus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluation of Electrodialysis Desalination Performance of Novel Bioinspired and Conventional Ion Exchange Membranes with Sodium Chloride Feed Solutions

Electrodialysis (ED) desalination performance of different conventional and laboratory-scale ion exchange membranes (IEMs) has been evaluated by many researchers, but most of these studies used their own sets of experimental parameters such as feed solution compositions and concentrations, superficial velocities of the process streams (diluate, concentrate, and electrode rinse), applied electrical voltages, and types of IEMs. Thus, direct comparison of ED desalination performance of different IEMs is virtually impossible. While the use of different conventional IEMs in ED has been reported, the use of bioinspired ion exchange membrane has not been reported yet. The goal of this study was to evaluate the ED desalination performance differences between novel laboratory‑scale bioinspired IEM and conventional IEMs by determining (i) limiting current density, (ii) current density, (iii) current efficiency, (iv) salinity reduction in diluate stream, (v) normalized specific energy consumption, and (vi) water flux by osmosis as a function of (a) initial concentration of NaCl feed solution (diluate and concentrate streams), (b) superficial velocity of feed solution, and (c) applied stack voltage per cell-pair of membranes. A laboratory‑scale single stage batch-recycle electrodialysis experimental apparatus was assembled with five cell‑pairs of IEMs with an active cross-sectional area of 7.84 cm2. In this study, seven combinations of IEMs (commercial and laboratory-made) were compared: (i) Neosepta AMX/CMX, (ii) PCA PCSA/PCSK, (iii) Fujifilm Type 1 AEM/CEM, (iv) SUEZ AR204SZRA/CR67HMR, (v) Ralex AMH-PES/CMH-PES, (vi) Neosepta AMX/Bare Polycarbonate membrane (Polycarb), and (vii) Neosepta AMX/Sandia novel bioinspired cation exchange membrane (SandiaCEM). ED desalination performance with the Sandia novel bioinspired cation exchange membrane (SandiaCEM) was found to be competitive with commercial Neosepta CMX cation exchange membrane.

42 ENGINEERING↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Experimental Studies of Carbon Nanotube Materials for Space Radiators

Game ]changing propulsion systems are often enabled by novel designs using advanced materials. Radiator performance dictates power output for nuclear electric propulsion (NEP) systems. Carbon nanotubes (CNT) and carbon fiber materials have the potential to offer significant improvements in thermal conductivity and mass properties. A test apparatus was developed to test advanced radiator designs. This test apparatus uses a resistance heater inside a graphite tube. Metallic tubes can be slipped over the graphite tube to simulate a heat pipe. Several sub ]scale test articles were fabricated using CNT cloth and pitch ]based carbon fibers, which were bonded to a metallic tube using an active braze material. The test articles were heated up to 600 C and an infrared (IR) camera captured the results. The test apparatus and experimental results are presented here.

SanSoucie, MIchael P.↗

Experiments in gasdynamics of explosions.

Various topics concerning recent accomplishments in experimental studies of gasdynamics of explosions are reviewed. Detonations, shocks, and blast waves form these topics. The most important feature of current studies is the particular attention paid to transient processes and the concomitant progress made in the development of novel experimental means for the study of such processes. The most exciting prospects for the future are associated with possibilities of exploiting knowledge of explosion phenomena for the development of such interesting devices as the gasdynamic laser and the apparatus based on the use of lasers to achieve controlled thermonuclear reaction.

Oppenheim, A. K.↗

Tensile testing apparatus

An improved mechanical extensometer is described for use with a constant load creep test machine. The dead weight of the extensometer is counterbalanced by two pairs of weights connected through a pulley system and to rod extension and leading into the furnace where the test sample is undergoing elevated temperature (above 500 F.) tensile testing. Novel gripper surfaces, conical tip and flat surface are provided in each sampling engaging platens to reduce the grip pressure normally required for attachment of the extensometer to the specimen and reduce initial specimen bending normally associated with foil-gage metal testing.

Blackburn, L. B.↗

Novel animal model of multiple sclerosis: The glial connexin gap junction as an environmental tuner for neuroinflammation

Abstract Connexins, which comprise gap junctions (GJs) via homotypic/heterotypic oligomerization, act as channels to connect opposing cells, mainly in solid organs such as the skin, liver, heart, and central/peripheral nervous system. Connexins are synthesized in the endoplasmic reticulum, assembled in the Golgi apparatus as hexamers, and inserted into the cell membrane as hemichannels. These hemichannels are closed under normal conditions until they combine to form clusters and connect to neighboring cells via GJs in a head‐to‐head configuration. Opening of hemichannels, which depends on the intra‐ or extracellular environment, allows various bioactive molecules to enter into or be released from the host cells. Recent pathological studies on human demyelinating diseases have revealed alterations of connexin expression patterns in demyelinating lesions. To elucidate the molecular mechanisms of connexins in the pathomechanisms of inflammatory demyelination, we induced experimental autoimmune encephalomyelitis (EAE) in connexin 30 (Cx30)‐deficient mice, oligodendroglia‐specific Cx47‐ablated mice, and astroglia‐specific Cx43‐ablated mice. We found that both astroglial‐Cx30‐deficient mice and Cx43‐ablated mice showed amelioration of the clinical course of EAE, while oligodendroglial‐Cx47‐ablated mice showed aggravation. These findings indicate the distinct role of connexins expressed in different cell types and the substantial contribution of connexin‐mediated pathology to demyelinating disorders. The imbalance in connexin expression, which is caused by the inflammatory environment, results in an increase in hemichannels in glial cells. The release of proinflammatory molecules induced by the increase in hemichannels on activated glial cells is a crucial mechanism of demyelinating disorders.

Yamasaki, Ryo↗

Novel Optical Diagnostic Techniques for Studying Particle Deposition Upon Large Cylinders in a Sheared Suspension

On a twelve-month voyage to Mars, one astronaut will require at least two tons of potable water and two tons of pure oxygen. Efficient, reliable fluid reclamation is therefore necessary for manned space exploration. Space habitats require a compact, flexible, and robust apparatus capable of solid-fluid mechanical separation over a wide range of fluid and particle densities and particle sizes. In space, centrifugal filtration, where particles suspended in fluid are captured by rotating fixed-fiber mat filters, is a logical candidate for mechanical separation. Non-colloidal particles are deposited on the fibers due to inertial impaction or direct interception. Since rotation rates are easily adjustable, inertial effects are the most practical way to control separation rates for a wide variety of multiphase mixtures in variable gravity environments. Understanding how fluid inertia and differential fluid-particle inertia, characterized by the Reynolds and Stokes numbers, respectively, affect deposition is critical in optimizing filtration in a microgravity environment. This work will develop non-intrusive optical diagnostic techniques for directly visualizing where and when non-colloidal particles deposit upon, or contact, solid surfaces: 'particle proximity sensors'. To model particle deposition upon a single filter fiber, these sensors will be used in ground-based experiments to study particle dynamics as in the vicinity of a large (compared with the particles) cylinder in a simply sheared (i.e., linearly-varying, zero-mean velocity profile) neutrally-buoyant, refractive-index matched solid-liquid suspension.

Yoda, M.↗

Method of and Apparatus for Histological Human Tissue Characterization Using Ultrasound

A method and apparatus for determining important histological characteristics of tissue, including a determination of the tissue's health. Electrical pulses are converted into meaningful numerical representations through the use of Fourier Transforms. These numerical representations are then used to determine important histological characteristics of tissue. This novel invention does not require rectification and thus provides for detailed information from the ultrasonic scan.

Yost, William T.↗

Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

Kelley, Anthony R.↗

Quality assurance and quality control of the $26~\text {m}^2$ SiPM production for the DarkSide-20k dark matter experiment

DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with 50 tonnes of low radioactivity underground argon (UAr) acting as the WIMP target. NUV-HD-cryo Silicon Photomultipliers (SiPM)s designed by Fondazione Bruno Kessler (FBK) (Trento, Italy) were selected as the photon sensors covering two $10.5~\text {m}^2$ Optical Planes, one at each end of the TPC, and a total of $5~\text {m}^2$ photosensitive surface for the liquid argon veto detectors. This paper describes the Quality Assurance and Quality Control (QA/QC) plan and procedures accompanying the production of FBK NUV-HD-cryo SiPM wafers manufactured by LFoundry s.r.l. (Avezzano, AQ, Italy). SiPM characteristics are measured at 77 K at the wafer level with a custom-designed probe station. As of March 2025, 1314 of the 1400 production wafers (94% of the total) for DarkSide-20k were tested. The wafer yield is $93.2\pm 2.5$%, which exceeds the 80% specification defined in the original DarkSide-20k production plan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Silicon Carbide (SiC) Fiber Manufacture: Continuous Processing of Novel Precursors via Modified Material Handling

General Atomics Electromagnetic Systems (GA-EMS) together with The Nonwovens Institute (NWI) and Harper International have executed on a development project to improve the production efficiency and reduce the production cost of silicon carbide (SiC) fiber – a critical material that advances US energy security and aerospace leadership. In the first budget period (BP1), the modified tow throughput (MTT) apparatus was developed, enabling fiber spinning in the form of loose coils rather than tightly packed spools (Figure 1) for batch processing of SiC fiber. This coil-based approach was proven to be capable of uniform fiber crosslinking and ceramic conversion, as well as demonstrating key process efficiencies while meeting the program fiber property targets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method of and Apparatus for Histological Human Tissue Characterization Using Ultrasound

A method and apparatus for determining important histological characteristics of tissue, including a determination of the tissue's health is discussed. Electrical pulses are converted into meaningful numerical representations through the use of Fourier Transforms. These numerical representations are then used to determine important histological characteristics of tissue. This novel invention does not require rectification and thus provides for detailed information from the ultrasonic scan.

Yost, William T.↗

A conserved chaperone protein is required for the formation of a noncanonical type VI secretion system spike tip complex

Type VI secretion systems (T6SSs) are dynamic protein nanomachines found in Gram-negative bacteria that deliver toxic effector proteins into target cells in a contact-dependent manner. Prior to secretion, many T6SS effector proteins require chaperones and/or accessory proteins for proper loading onto the structural components of the T6SS apparatus. However, despite their established importance, the precise molecular function of several T6SS accessory protein families remains unclear. In this study, we set out to characterize the DUF2169 family of T6SS accessory proteins. Using gene co-occurrence analyses, we find that DUF2169-encoding genes strictly co-occur with genes encoding T6SS spike complexes formed by valine-glycine repeat protein G (VgrG) and DUF4150 domains. Although structurally similar to Pro-Ala-Ala-Arg (PAAR) domains, “PAAR-like” DUF4150 domains lack PAAR motifs and instead contain a conserved PIPY motif, leading us to designate them PIPY domains. Next, we present both genetic and biochemical evidence that PIPY domains require a cognate DUF2169 protein to form a functional T6SS spike complex with VgrG. This contrasts with canonical PAAR proteins, which bind VgrG on their own to form functional spike complexes. By solving the first crystal structure of a DUF2169 protein, we show that this T6SS accessory protein adopts a novel protein fold. Furthermore, biophysical and structural modeling data suggest that DUF2169 contains a dynamic loop that physically interacts with a hydrophobic patch on the surface of its cognate PIPY domain. Based on these findings, we propose a model whereby DUF2169 proteins function as molecular chaperones that maintain VgrG–PIPY spike complexes in a secretion-competent state prior to their export by the T6SS apparatus.

DUF2169↗

Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

A shake test of the Large Rotor Test Apparatus (LRTA) was performed in an effort to enhance NASAscapability to measure dynamic hub loads for full-scale rotor tests. This paper documents the results of theshake test as well as efforts to calibrate the LRTA balance system to measure dynamic loads.Dynamic rotor loads are the primary source of vibration in helicopters and other rotorcraft, leading topassenger discomfort and damage due to fatigue of aircraft components. There are novel methods beingdeveloped to reduce rotor vibrations, but measuring the actual vibration reductions on full-scale rotorsremains a challenge. In order to measure rotor forces on the LRTA, a balance system in the non-rotatingframe is used. The forces at the balance can then be translated to the hub reference frame to measure therotor loads. Because the LRTA has its own dynamic response, the balance system must be calibrated toinclude the natural frequencies of the test rig.

Shake Test Results↗

Preparation for and Performance of a Pseudomonas aeruginosa Biofilm Experiment On Board the International Space Station

Biofilms are a problem on Earth given their ability to degrade the materials upon which they grow and due to their relevance to infections. Remarkably, 65% and 80% of infections and chronic diseases on Earth are associated with biofilms, respectively. In space, these problems' impact is higher because the crew's lives and mission success depend on nominal operation of mechanical systems. Furthermore, the isolated confined environment nature of spaceflight may increase the rates of disease transmission. In the case of the International Space Station (ISS), biofilms are an identified problem on the Environmental Control and Life Support System (ECLSS), namely on the water processor assembly (WPA). In late 2019, the Space Biofilms experiment launched towards ISS to (i) characterize the mass, thickness, morphology, and gene expression of biofilms formed in space with respect to matched Earth controls, (ii) interrogate the expression of antimicrobial resistance genes, and (iii) test novel materials as potential biofilm control strategies for future ECLSS components. For this, 288 bacterial samples were prepared prior to the launch of the Northrop Grumman CRS-12 mission from NASA's Wallops Flight Facility. The samples were integrated into the spaceflight hardware, BioServe's Fluid Processing Apparatus (FPA) packed in sets of eight in Group Activation Packs (GAP). Half of these samples were activated and terminated on orbit by NASA astronauts Jessica Meir and Christina Koch, while the remaining half were processed equivalently on Earth. The spaceflight bacterial samples of Space Biofilms returned on board SpaceX' CRS-19 Dragon spacecraft, in early 2020. We here describe the test campaign implemented to verify the experiment design and confirm it would enable us to achieve the project's scientific goals. This campaign ended with the Experiment Verification Test (EVT), from which we here present example morphology and transcriptomic results. We describe in detail the sample preparation prior to flight, including cleaning and sterilization of the coupons of six materials (SS316, passivated-SS316, lubricant impregnated surface, catheter-grade silicone with and without a nanotopography, and cellulose membrane), loading and integration of growth media, bacterial inoculum, fixative and preservative to enable experiment termination on orbit. Additionally, we describe the performance of the experiment on board the ISS, including crew activities, use of assets, temperature profile, and experiment timeline; all leading to a successful spaceflight experiment.

Pamela Flores↗

Methods and Apparatus for Reducing Multipath Signal Error Using Deconvolution

A deconvolution approach to adaptive signal processing has been applied to the elimination of signal multipath errors as embodied in one preferred embodiment in a global positioning system receiver. The method and receiver of the present invention estimates then compensates for multipath effects in a comprehensive manner. Application of deconvolution, along with other adaptive identification and estimation techniques, results in completely novel GPS (Global Positioning System) receiver architecture.

Kumar, Rajendra↗

The Measurement of Shear Strain in Impact Ice Using a Modified Lap Joint Test and Digital Image Correlation

The results of ice adhesion testing efforts are typically quantified using the maximum shear stress sustained at the interface before the ice detaches from the underlying substrate. While this singular value can be useful for understanding the role icing wind tunnel conditions and substrate surface properties have on the strength of the ice-substrate interface, it does not capture the mechanical behavior of the ice during an experiment. To better understand the deformation of the ice sample and ice-substrate interface during testing, digital image correlation was applied to the lap-joint shear test methodology utilized at NASA Glenn Research Center. Preparation of the sample surface for digital image correlation, initial parsing of the correlation data, and the time synchronization of data from multiple sources are discussed. Using the directional components of deformation measured via digital image correlation, a novel approach to calculating the interfacial shear strain is presented. Results from analyzing several impact ice samples consistently reveals a non-linear response in the ice during mechanical loading which occurs prior to sample delamination, a behavior not observable in the force and displacement data gathered from the testing apparatus. Both the full and small angle forms of the engineering shear strain are evaluated, with the full shear strain form providing considerably lower noise levels. The transition of sample response from near the interface to the bulk behavior of the ice under shear loading is discussed with results from several samples being presented.

Ice adhesion↗

The Measurement of Shear Strain in Impact Ice Using a Modified Lap Joint Test and Digital Image Correlation

The results of ice adhesion testing efforts are typically quantified using the maximum shear stress sustained at the interface before the ice detaches from the underlying substrate. While this singular value can be useful for understanding the role icing wind tunnel conditions and substrate surface properties have on the strength of the ice-substrate interface, it does not capture the mechanical behavior of the ice during an experiment. To better understand the deformation of the ice sample and ice-substrate interface during testing, digital image correlation was applied to the lap-joint shear test methodology utilized at NASA Glenn Research Center. Preparation of the sample surface for digital image correlation, initial parsing of the correlation data, and the time synchronization of data from multiple sources are discussed. Using the directional components of deformation measured via digital image correlation, a novel approach to calculating the interfacial shear strain is presented. Results from analyzing several impact ice samples consistently reveals a non-linear response in the ice during mechanical loading which occurs prior to sample delamination, a behavior not observable in the force and displacement data gathered from the testing apparatus. Both the full and small angle forms of the engineering shear strain are evaluated, with the full shear strain form providing considerably lower noise levels. The transition of sample response from near the interface to the bulk behavior of the ice under shear loading is discussed with results from several samples being presented.

: Ice Adhesion, Digital Image Correlation, Experim↗