Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The high intensity diffractometer for residual stress analysis (HIDRA), a third generation residual stress mapping neutron diffractometer at the high flux isotope reactor

This paper describes the hardware and software upgrades, operation, and performance of the high intensity diffractometer for residual stress analysis (HIDRA) instrument, a residual stress mapping neutron diffractometer located at the High Flux Isotope Reactor at Oak Ridge National Laboratory in Oak Ridge Tennessee, USA. Following a major upgrade in 2018, the new instrument has a single 3 He multiwire 2D 30 × 30 cm 2 position sensitive detector, yielding a field of view of 17° 2θ. Further, the increase in the field of view (from 4° 2θ) from the previous model instrument has contributed to the tremendous improvement in the out of plane solid angle such that the 3D count rate could be obtained easily. Accordingly, the hardware, software, Data Acquisition System (DAS), and so on have also been updated. Finally, all these enhanced features of HIDRA have been ably demonstrated by conducting multi directional diffraction measurements in the quenched 750-T74 aluminum, and the evolved and improved strain/stress mappings are presented.

3D printing↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photo-induced electron paramagnetic resonance: A means to identify defects and the defect level throughout the bandgap of ultrawide bandgap semiconductors

Ultrawide bandgap semiconductors (UWBGs) provide great promise for optical devices operating in the near to deep ultraviolet, and recently they have become a viable semiconducting material for high power electronics. From the power grid to electronic vehicles, the intention is to replace massively awkward components with the convenience of a solid state electronic “chip.” Unfortunately, the challenges faced by wide bandgap electronic materials, such as GaN and SiC, increase as the bandgap increases. A point defect, for example, can take on more charge states and energy configurations. This perspective describes a method to investigate the many charge states and their associated transitions—photo-induced electron paramagnetic resonance (photo-EPR) spectroscopy. Although not new to the study of defects in semiconductors, photo-EPR studies can probe the entire ultrawide bandgap given the appropriate light source for excitation. Examples provided here cover specific defects in UWBGs, AlN, and Ga2O3. The discussion also reminds us how the rapid pace of discovery surrounding this newest class of semiconductors is due, in part, to fundamental research studies of the past, some as far back as a century ago and some based on very different materials systems.

Physics↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Obtaining bulk-like correlated oxide surfaces with protective caps

Functional oxides exhibit a diverse range of correlated electron phenomena, some of which are highly attractive for novel electronic, magnetic, and optical devices. Despite decades of advancement of our fundamental understanding of these materials, they consistently fall short of realizing their promise in functional devices. We identify a significant bottleneck toward device realization to be surface overoxidation. Protective caps can effectively prevent overoxidation, but their interfaces with functional oxides are not well understood. These interfaces are critical for effectively using functional oxides in field-effect devices, where “the interface is the device.” This work addresses the chemistry and physics of the interface between protective caps and the correlated metal SrVO3, a model functional oxide. Our comparison of five different cap materials reveals effective protection and similar SrVO3 surface chemistry in all cases. Systematic comparisons of surface and bulk-sensitive photoelectron spectra reveal that negligible interface redox takes place, elucidating the cap-SrVO3 interface chemistry. This work demonstrates a robust and simple solution to the surface overoxidation problem in vanadates, paving the way toward effectively using these materials in field-effect devices. Our conclusions are general and can be applied to numerous other systems, thus moving oxide electronics closer to the realization of functional devices.

Cohen, Amit (ORCID:0009000276477510)↗

StarDICE III: characterization of the photometric instrument with a collimated beam projector

The measurement of Type Ia supernovae magnitudes provides cosmological distances, which constrain dark energy parameters. Current and upcoming large photometric surveys require improved photometric calibration precision to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment aims to establish accurate broad-band flux references for these surveys, targeting sub-percent precision in magnitude measurements. Achieving this requires precise filter bandpass measurements for both StarDICE and survey instruments with sub-nanometre accuracy. To this end, we developed the Collimated Beam Projector (CBP), an optical device for calibrating the throughput of astronomical telescopes and their filters. The CBP uses a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam, continuously monitored in flux and wavelength. The CBP output flux is measured with a large-area photodiode calibrated relative to a NIST photodiode. Using CBP measurements, we derive the StarDICE telescope throughput and filter transmissions, anchoring them to NIST’s absolute calibration. After analysing systematic uncertainties, we achieved sub-nanometre accuracy for filter central wavelengths, measured filter transmission with ~0.5 per cent precision per 1 nm bin, and detected out-of-band leakages at a relative level of 10 –4 ⁠. Furthermore, we synthesized equivalent transmission for full pupil illumination from four sampled positions in the StarDICE telescope mirror, with ~0.2 nm accuracy for central wavelengths and 7 mmag for broad-band fluxes. This demonstrates our ability to characterize telescope throughput down to the millimagnitude, paving the way for future developments, such as the Rubin-CBP for measuring the LSST at Vera Rubin Observatory, and a portable CBP version for in-situ transmission monitoring.

Calibration↗

Isolation of Single Donors in ZnO

The shallow donor in zinc oxide (ZnO) is a promising semiconductor spin qubit with optical access. Single indium donors are isolated in a commercial ZnO substrate using plasma focused ion beam (PFIB) milling. Quantum emitters are identified optically by spatial and frequency filtering. The indium donor assignment is based on the optical bound exciton transition energy and magnetic dependence. The emission stability of these single donors in terms of both intensity and frequency, alongside their transition linewidths less than twice the lifetime limit, highlight the promise of single In donors as optically accessible spin qubits. Here, the optical stability of single donors after FIB fabrication is promising for optical device integration required for scalable quantum technologies based on single donors in direct band gap semiconductors.

42 ENGINEERING↗

Gaussian approximation potential for amorphous Si : H

Hydrogenation of amorphous silicon (a–Si : H) is critical for reducing defect densities, passivating midgap states and surfaces, and improving photoconductivity in silicon-based electro-optical devices. Modeling the atomic-scale structure of this material is critical to understanding these processes, which in turn is needed to describe c–Si/a–Si : H heterojunctions that are at the heart of modern solar cells with world-record efficiency. Density functional theory (DFT) studies achieve the required high accuracy but are limited to moderate system sizes of 100 atoms or so by their high computational cost. Simulations of amorphous materials have been hindered by this high cost because large structural models are required to capture the medium-range order that is characteristic of such materials. Empirical potential models are much faster, but their accuracy is not sufficient to correctly describe the frustrated local structure. Data-driven, machine-learned interatomic potentials have broken this impasse and have been highly successful in describing a variety of amorphous materials in their elemental phase. Here, we extend the Gaussian approximation potential (GAP) for silicon by incorporating the interaction with hydrogen, thereby significantly improving the degree of realism with which amorphous silicon can be modeled. We show that our Si : H GAP enables the simulation of hydrogenated silicon with an accuracy very close to DFT but with computational expense and run times reduced by several orders of magnitude for large structures. Here, we demonstrate the capabilities of the Si : H GAP by creating models of hydrogenated liquid and amorphous silicon and showing that their energies, forces, and stresses are in excellent agreement with DFT results, and their structure as captured by bond and angle distributions are in agreement with both DFT and experiments.

36 MATERIALS SCIENCE↗

Plasmonic nanoarcs: a versatile platform with tunable localized surface plasmon resonances in octave intervals

The tunability of the longitudinal localized surface plasmon resonances (LSPRs) of metallic nanoarcs is demonstrated with key relationships identified between geometric parameters of the arcs and their resonances in the infrared. The wavelength of the LSPRs is tuned by the mid-arc length of the nanoarc. The ratio between the attenuation of the fundamental and second order LSPRs is governed by the nanoarc central angle. Beneficial for plasmonic enhancement of harmonic generation, these two resonances can be tuned independently to obtain octave intervals through the design of a non-uniform arc-width profile. Because the character of the fundamental LSPR mode in nanoarcs combines an electric and a magnetic dipole, plasmonic nanoarcs with tunable resonances can serve as versatile building blocks for chiroptical and nonlinear optical devices.

42 ENGINEERING↗

Ultra-broadband mid-infrared generation in dispersion-engineered thin-film lithium niobate

Thin-film lithium niobate (TFLN) is an emerging platform for compact, low-power nonlinear-optical devices, and has been used extensively for near-infrared frequency conversion. Recent work has extended these devices to mid-infrared wavelengths, where broadly tunable sources may be used for chemical sensing. To this end, we demonstrate efficient and broadband difference frequency generation between a fixed 1-µm pump and a tunable telecom source in uniformly-poled TFLN-on-sapphire by harnessing the dispersion-engineering available in tightly-confining waveguides. We show a simultaneous 1–2 order-of-magnitude improvement in conversion efficiency and ∼5-fold enhancement of operating bandwidth for mid-infrared generation when compared to equal-length conventional lithium niobate waveguides. We also examine the effects of mid-infrared loss from surface-adsorbed water on the performance of these devices.

47 OTHER INSTRUMENTATION↗

Wavelength-tunable infrared chiral metasurfaces with phase-change materials

Optical phase-change materials exhibit tunable permittivity and switching properties during phase transition, which offers the possibility of dynamic control of optical devices. Here, a wavelength-tunable infrared chiral metasurface integrated with phase-change material GST-225 is demonstrated with the designed unit cell of parallelogram-shaped resonator. By varying the baking time at a temperature above the phase transition temperature of GST-225, the resonance wavelength of the chiral metasurface is tuned in the wavelength range of 2.33 µm to 2.58 µm, while the circular dichroism in absorption is maintained around 0.44. The chiroptical response of the designed metasurface is revealed by analyzing the electromagnetic field and displacement current distributions under left- and right-handed circularly polarized (LCP and RCP) light illumination. Moreover, the photothermal effect is simulated to investigate the large temperature difference in the chiral metasurface under LCP and RCP illumination, which allows for the possibility of circular polarization-controlled phase transition. The presented chiral metasurfaces with phase-change materials offer the potential to facilitate promising applications in the infrared regime, such as chiral thermal switching, infrared imaging, and tunable chiral photonics.

36 MATERIALS SCIENCE↗

Infrared phase-change chiral metasurfaces with tunable circular dichroism

Integrating phase-change materials in metasurfaces has emerged as a powerful strategy to realize optical devices with tunable electromagnetic responses. Here, phase-change chiral metasurfaces based on GST-225 material with the designed trapezoid-shaped resonators are demonstrated to achieve tunable circular dichroism (CD) responses in the infrared regime. The asymmetric trapezoid-shaped resonators are designed to support two chiral plasmonic resonances with opposite CD responses for realizing switchable CD between negative and positive values using the GST phase change from amorphous to crystalline. The electromagnetic field distributions of the chiral plasmonic resonant modes are analyzed to understand the chiroptical responses of the metasurface. Furthermore, the variations in the absorption spectrum and CD value for the metasurface as a function of the baking time during the GST phase transition are analyzed to reveal the underlying thermal tuning process of the metasurface. The demonstrated phase-change metasurfaces with tunable CD responses hold significant promise in enabling many applications in the infrared regime such as chiral sensing, encrypted communication, and thermal imaging.

42 ENGINEERING↗

Parametric study of optical transmission through plasmonic hole arrays modulated by the phase transition of vanadium dioxide

We have performed comprehensive electromagnetic simulations and preliminary experiments to explore the effects of geometrical and material parameters on the extraordinary optical transmission (EOT) through periodic arrays of subwavelength holes in a bilayer stack consisting of a gold or silver film atop a vanadium dioxide film (Au/Ag + VO 2 ), where the latter undergoes a semiconductor-to-metal phase transition. Using the finite-difference time-domain (FDTD) and finite-element methods (FEM), we vary iteratively the array periodicity, VO 2 film thickness and hole diameters, as well as the refractive index inside the VO 2 -layer holes and the VO 2 optical constants. For each variation, we compare the metallic-to-semiconducting ratios of the zero-order transmission ( T 00 ) peaks and find sharp maxima in these ratios within narrow parameter ranges. The maxima arise from Fabry-Perot and Fano-type resonances that minimize T 00 in the semiconducting phase of the perforated bilayers. At a fixed array period, the primary factors controlling the VO 2 -enabled EOT modulation are the VO 2 thickness, diameter of the VO 2 -layer holes, and absorption in the two VO 2 phases. Besides uncovering the origins of the higher metallic-phase T 00 , this study provides a protocol for optimizing the performance of the bilayer hole arrays for potential uses as dynamically tunable nano-optical devices.

Donev, Eugenii U. (ORCID:000000030555219X)↗

Patterning of magneto-optical nanomaterials

Patterning of colloidal particles in precisely organized architectures has attracted intense research interest for decades. This is due to their potential applications in flexible electronics, magnetic and optical devices, sensors, biotechnology, communications, etc. However, creation of mesoscale assemblies at commercial scale received less attention. The mesoscale systems reside between the micro- and macroscopic scales, with length dimensions from ≈ 100 um to 5mm. One way to create mesoscale materials is to leverage decades of experimental and theoretical research in nanomaterials field that allows us to precisely create and control the placement of nanoscale materials. We developed a versatile and automatic mesoscale patterning technology that provide precise and consistent control and special arrangement of functional nanomaterials. The versatility of the strategy is demonstrated by patterning nanoparticles with different dimensions, shapes and compositions, tethered with various functionalities and subjected to different external stimuli. Nanomaterials were created via the paten t pending automated flow-throughput domain process (AFTDP), aka nano-additive manufacturing approach, recently developed by us, based on a unique small-scale fluidics concept, that enables a uniform reaction environment for production of high-quality materials in large quantities.

36 MATERIALS SCIENCE↗

Patterning of magneto-optical nanomaterials

Patterning of colloidal particles in precisely organized architectures has attracted intense research interest for decades. This is due to their potential applications in flexible electronics, magnetic and optical devices, sensors, biotechnology, communications, etc. However, creation of mesoscale assemblies at commercial scales have received less attention. The mesoscale systems reside between the micro- and macroscopic scales, with length dimensions from ≈ 100 µm to 5 mm. By leveraging decades of experimental and theoretical research in nanomaterial fields, we were able to precisely create and control the placement of nanoscale materials, allowing us to create mesoscale materials. We developed a versatile and automatic mesoscale patterning technology (via SEM-FIB and 3D printing) that provides precise and consistent control and special arrangement of functional nanomaterials. The versatility of the strategy is demonstrated by patterning nanoparticles with different dimensions, shapes and compositions, tethered with various functionalities and subjected to different external stimuli.

42 ENGINEERING↗

Topology Optimization of Manufacturable Photonic Crystals With Complete Bandgaps [Dissertation]

Periodic structures consisting of dielectric material, i.e. photonic crystals, are capable of prohibiting electromagnetic waves within frequency ranges referred to as bandgaps. This principle was first demonstrated with alternating slabs of material and later demonstrated with three-dimensional (3D) structures capable of reflecting waves from any incident angle. A number of potential applications for photonic bandgap structures exist, including loss-less sharp corner waveguides, fiber optics, and radome design. Further, many optical devices could benefit from the perfect-mirror behavior of photonic crystals.

36 MATERIALS SCIENCE↗

In Situ X-ray Measurements to Follow the Crystallization of BaTiO 3 Thin Films during RF-Magnetron Sputter Deposition

Here, we report on adding an important dimension to the fundamental understanding of the evolution of the thin film micro structure evolution. Thin films have gained broad attention in their applications for electro-optical devices, solar-cell technology, as well storage devices. Deep insights into fundamental functionalities can be realized via studying crystallization microstructure and formation processes of polycrystalline or epitaxial thin films. Besides the fundamental aspects, it is industrially important to minimize cost which intrinsically requires lower energy consumption at increasing performance which requires new approaches to thin film growth in general. Here, we present a state of the art sputtering technique that allows for time-resolved in situ studies of such thin film growth with a special focus on the crystallization via small angle scattering and X-ray diffraction. Focusing on the crystallization of the example material of BaTiO 3 , we demonstrate how a prototypical thin film forms and how detailed all phases of the structural evolution can be identified. The technique is shaped to enable a versatile approach for understanding and ultimately controlling a broad variety of growth processes, and more over it demonstrate how to in situ investigate the influence of single high temperature sputtering parameters on the film quality. It is shown that the whole evolution from nucleation, diffusion adsorption and grain growth to the crystallization can be observed during all stages of thin film growth as well as quantitatively as qualitatively. This can be used to optimize thin-film quality, efficiency and performance.

36 MATERIALS SCIENCE↗