Modular optical test instrument for 1700-11,000 angstrom units.
Optical measuring instrument consisting of eight modular units, specimen chamber and carriage
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Optical measuring instrument consisting of eight modular units, specimen chamber and carriage
Instruments and devices based on optical fiber were originally simple and passive. That has changed. A variety of devices uses optical fiber for sensing, communications and various optoelectronic functions. This paper discusses the creation of a hybrid optical fiber that incorporates not just the light transmission function but other types of materials and new multiple fiber arrangements. Recent experiences with a fiber draw tower reveal new possibilities for achieving multifunctional devices able to perform diverse instrumentation sensing applications. This is achievable even with feature sizes, when desired, on the nanoscale. For instance, fiber comprised of one or more light guides and one or more electrically conducting wires is feasible. This combination of optical fiber and metal wire may be termed a wiber . The wiber could determine temperature and proximity to surfaces, detect radio-frequency radiation, and provide electrical power. At the same time, a wiber would have the capability to simultaneously transmit light where the light is utilized to sense temperature and proximity and give illumination. There are many possible uses--depending on design and configuration--cutting across many technologies and programs.
Instruments used in ocean color remote sensing algorithm development, validation, and data acquisition which have the potential for further commercial development and marketing are discussed. The Ocean Data Acquisition System (ODAS) is an aircraft-borne radiometer system suitable for light aircraft, which has applications for rapid measurement of chlorophyll pigment concentrations along the flight line. The instrument package includes a three channel radiometer system for upwelling radiance, an infrared temperature sensor, a three-channel downwelling irradiance sensor, and Loran-C navigation. Data are stored on a PC and processed to transects or interpolated 'images' on the ground. The instrument has been in operational use for two and one half years. The accuracy of pigment concentrations from the instrument is quite good, even in complex Chesapeake Bay waters. To help meet the requirement for validation of future satellite missions, a prototype air-deployable drifting buoy for measurement of near-surface upwelled radiance in multiple channnels is undergoing test deployment. The optical drifter burst samples radiance, stores and processes the data, and uses the Argos system as a data link. Studies are underway to explore the limits to useful lifetime with respect to power and fouling.
Training Manual RQA/M5 provides a basic course of instruction in the use of optical instruments for precise dimensional control and alignment of structural elements and assemblies, such as associated with space vehicles, aircraft, ships, and buildings.
Instrumentation used in optical polarimetry is discussed with reference to high-resolution spectropolarimetry, an orbiter cloud photopolarimeter, X-ray polarimeters, and the design of a self-nulling ellipsometer. Consideration is given to surface and thin-film ellipsometry noting studies of electrochemical surface layers, surface anisotropy, polish layers on infrared window materials, and anodic films. Papers on biological, chemical, and physical polarimetry are presented including birefringence in biological materials, vibrational optical activity, and the optical determination of the thermodynamic phase diagram of a metamagnet. Remote sensing is discussed in terms of polarization imagery, the optical polarimetry of particulate surfaces, and techniques and applications of elliptical polarimetry in astronomy and atmospheric studies.
For many aspheric and freeform optical components, existing interferometric solutions require a custom computer-generated hologram (CGH) to characterize the part. The overall objective of this research is to develop hardware and a procedure to produce a combined, dynamic, Hartmann/ Digital Holographic interferometry inspection system for a wide range of advanced optical components, including aspheric and freeform optics. This new instrument would have greater versatility and dynamic range than currently available measurement systems. The method uses a spatial light modulator to pre-condition wavefronts for imaging, interferometry, and data processing to improve the resolution and versatility of an optical inspection instrument. Existing interferometers and Hartmann inspection systems have either too small a dynamic range or insufficient resolution to characterize conveniently unusual optical surfaces like aspherical and freeform optics. For interferometers, a specially produced, computer-generated holographic optical element is needed to transform the wavefront to within the range of the interferometer. A new hybrid wavefront sensor employs newly available spatial light modulators (SLMs) as programmable holographic optical elements (HOEs). The HOE is programmed to enable the same instrument to inspect an optical element in stages, first by a Hartmann measurement, which has a very large dynamic range but less resolution. The first measurement provides the information required to precondition a reference wave that avails the measurement process to the more precise phase shifting interferometry. The SLM preconditions a wavefront before it is used to inspect an optical component. This adds important features to an optical inspection system, enabling not just wavefront conditioning for null testing and dynamic range extension, but also the creation of hybrid measurement procedures. This, for example, allows the combination of dynamic digital holography and Hartmann sensing procedures to cover a virtually unlimited dynamic range with high resolution. Digital holography technology brings all of the power and benefits of digital holographic interferometry to the requirement, while Hartmann-type wavefront sensors bring deflectometry technologies to the solution. The SLM can be used to generate arbitrary wavefronts in one leg of the interferometer, thereby greatly simplifying its use and extending its range. The SLM can also be used to modify the system into a dynamic Shack-Hartmann system, which is useful for optical components with large amounts of slope. By integrating these capabilities into a single instrument, the system will have tremendous flexibility to measure a variety of optical shapes accurately.
Through the use of a special optical filter, the Thermal Infrared Imaging Spectrometer, an airborne multispectral IR imaging instrument operating in the thermal emission region (7.5-14 microns), will achieve signal-to-noise ratios greater than 600 with ambient temperature optics. This instrument will be used to do compositional surface mapping of the terrain, and will refine the ability to categorize rock families and types by providing much higher spectral resolution in the emission region than was previously available. Details of the optical system, the detector, the cooler system, and the support electronics are described.
Outer planets Grand Tour spacecraft onboard optical guidance instruments, discussing vidicon and image dissector systems designs
Integrated photonics generally is the integration of multiple lithographically defined photonic and electronic components and devices (e.g. lasers, detectors, waveguides passive structures, modulators, electronic control and optical interconnects) on a single platform with nanometer-scale feature sizes. The development of photonic integrated circuits permits size, weight, power and cost reductions for spacecraft microprocessors, optical communication, processor buses, advanced data processing, and integrated optic science instrument optical systems, subsystems and components. This is particularly critical for small spacecraft platforms. We will give an overview of some NASA applications for integrated photonics.
Integrated photonics generally is the integration of multiple lithographically defined photonic and electronic components and devices (e.g. lasers, detectors, waveguides passive structures, modulators, electronic control and optical interconnects) on a single platform with nanometer-scale feature sizes. The development of photonic integrated circuits permits size, weight, power and cost reductions for spacecraft microprocessors, optical communication, processor buses, advanced data processing, and integrated optic science instrument optical systems, subsystems and components. This is particularly critical for small spacecraft platforms. We will give an overview of some NASA applications for integrated photonics.
It has always been difficult to measure local temperature and flow velocity within fuel bundle geometries because of their complex and compact layouts. High-resolution mapping of the flow field is especially challenging. High-resolution data is typically obtained using optical instruments but optical access to the interior regions of a bundle is severely limited. Velocity fields within fuel bundle models have been mapped with particle image velocimetry (PIV), an optical technique that employs lasers and cameras. Optical access to the bundle interior is obtained using transparent materials and matching the refractive index of the physical structures with that of the fluid. Testing is necessarily isothermal because refractive indices vary with temperature. However, the ultimate aim of such studies is understanding fluid dynamics and heat transfer within real reactors and so flow field mapping under nonisothermal conditions is of particular interest. Temperature fields can be mapped at high-resolution using laser-induced fluorescence (LIF). However, as an optical technique it is unsuitable for nonisothermal liquid flows. This is due to the same sort of optical distortion that restricts PIV. It is also unsuitable for opaque fluids and setups with restricted optical access. Fiber optic distributed temperature sensing (DTS) offers a high-resolution alternative that does not rely upon imaging. A single sensor can map temperature fields at resolutions far exceeding that achievable with conventional sensors such as thermocouples. Though fiber optic sensors cannot match the spatial resolution and bandwidth of LIF, they are suitable for nonisothermal and opaque flows. And though fibers are physical probes that perturb the flow, they can be strung across complex geometries to provide data in regions lacking the optical access necessary for techniques like LIF. Distributed temperature sensing has the potential to provide fuel bundle temperature data of a type that cannot be obtained with optical methods or conventional sensors. This paper reports on preliminary results of efforts to use fiber optic distributed temperature sensors in a fuel bundle model. We are conducting a feasibility study exploring implementation issues such as strain control in the mounting configuration and signal noise associated with flow-induced vibration. We describe here the setup and present preliminary data from our first phase testing with stagnant flow. (authors)
The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.
The Atomic, Molecular and Optical Science (AMO) instrument at the Linac Coherent Light Source (LCLS) provides a tight soft X-ray focus into one of three experimental endstations. The flexible instrument design is optimized for studying a wide variety of phenomena requiring peak intensity. There is a suite of spectrometers and two photon area detectors available. An optional mirror-based split-and-delay unit can be used for X-ray pump–probe experiments. Recent scientific highlights illustrate the imaging, time-resolved spectroscopy and high-power density capabilities of the AMO instrument.
Traditionally, infrared (IR) space instruments have been focused by iterating with a number of different thickness shim rings in a thermal vacuum chamber until the focus meets requirements. This has required a number of thermal cycles that are very expensive as they tie up many integration and test (I&T)/ environmental technicians/engi neers work ing three shifts for weeks. Rather than creating a test shim for each iteration, this innovation replaces the test shim and can focus the instrument while in the thermal vacuum chamber. The focus tool consists of three small, piezo-actuated motors that drive two sets of mechanical interface flanges between the instrument optics and the focal- plane assembly, and three optical-displacement metrology sensors that can be read from outside the thermal vacuum chamber. The motors are used to drive the focal planes to different focal distances and acquire images, from which it is possible to determine the best focus. At the best focus position, the three optical displacement metrology sensors are used to determine the shim thickness needed. After the instrument leaves the thermal vacuum chamber, the focus tool is replaced with the precision-ground shim ring. The focus tool consists of two sets of collars, one that mounts to the backside of the interface flange of the instrument optics, and one that mounts to the backside of the interface flange of the focal plane modules. The collars on the instrument optics side have the three small piezo-actuated motors and the three optical displacement metrology systems. Before the instrument is focused, there is no shim ring in place and, therefore, no fasteners holding the focal plane modules to the cameras. Two focus tooling collars are held together by three strong springs. The Orbiting Carbon Observatory (OCO) mission spectrometer was focused this way (see figure). The motor described here had to be moved five times to reach an acceptable focus, all during the same thermal cycle, which was verified using pupil slicing techniques. A focus accuracy of .20.100 microns was achieved.
Optically Stimulated Electron Emission (OSEE) has been used to quantify surface contamination in the aerospace community. As advances are made towards the understanding of OSEE, it is desirable to incorporate technological advances with succeeding generations of instrumentation, so that improvements in the practical application of OSEE may be disseminated among the user community. Several studies undertaken by Yost, Welch, Abedin and others have expanded the knowledge base related to the underlying principles of OSEE. The conclusions of these studies, together with inputs from the user community were the foundation upon which the development of a third generation OSEE instrument was based. This manuscript describes the significant improvements incorporated into a third generation OSEE instrument as well as the elements unique to its design.
The James Webb Space Telescope (JWST) Optical Telescope Element + Integrated Science Instrument Module (OTIS) went through environmental testing at the Goddard Space Flight Center. The vibration and acoustic tests occurred outside of cleanrooms. These areas are typically around ISO Class 8, far out of specifications for JWST. Through collaboration between the OTIS Mechanical and Contamination Engineering teams, a portable clean enclosure was designed, built, and verified to prevent contamination of the sensitive OTIS assembly. This manuscript describes the process of designing and building this enclosure, including materials selection and High Efficiency Particle Air (HEPA) filtration. This enclosure also provided environmental control with a portable air conditioning unit to control the relative humidity level enabling personnel to work within it. The manuscript emphasizes working in a systematic order to maintain cleanliness and integrity. “Clean as you go” during construction was a top priority to ensure that this critical Ground Support Equipment (GSE) was acceptable. The process of installing the walls and then sealing their internal and external surfaces with approved films was critical to maintaining OTIS integrity. This proved important because OTIS was in the enclosure for months longer than originally planned. This manuscript concludes by reviewing the process used to verify that the OTIS clean enclosure could achieve acceptable contamination level fallout accumulation for use during the vibration and acoustic testing and then verifying that the predicted performance was achieved after testing was complete.
The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom optical mapping instrument (OMI) to improve measurement throughput time, facilitate automated measurements, allow for localized specimen examination, obtain spatial information relative to commercial benchtop spectrophotometer instruments, and provide automated data analysis. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. In addition to the unique instrument developed in this study, new insights have emerged from the examination of specimens from previous experiments, including: the depletion of the UV absorber is revealed for specimens beyond a certain size after artificial ultraviolet (UV) weathering; an optical degradation by internal haze formation is confirmed following Damp Heat (85 °C/85% relative humidity) testing; the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture; and the greater local (in the order of millimeters) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.
The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.