Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Towards Three-Dimensional Neutron Imaging with Light-field Technology

A broad range of applications in nuclear safeguards and security can benefit from compact, fast neutron imagers with large angular acceptance. However, accurate 3D multi-vertex reconstruction in a monolithic detector remains a significant barrier to realization. Current approaches, such as the centroiding approach and the use of shadow masks, have not yet resulted in a successful demonstration in a light-starved environment. This project explored the use of cutting-edge technology—a light field camera—which inherently preserves both the spatial and directional information of incident light. Such technology can, in principle, resolve multi-vertex events and offer accurate position reconstruction in 3D with relatively simple readout electronics. Since the project's inception in May 2023, we have built an experimental setup to calibrate and characterize a commercial light-field camera (Lytro Illum). We assessed its 3D event reconstruction capability in a relatively low-light intensity environment by analyzing the cross-correlation of a series of 2D images of a characterized tunable light source taken at various distances. A sub-cm resolution, lower than typical neutron interaction separations in a compact scintillator volume, was observed with the LED light source, suggesting the promising capability of its nominal optics design to provide the adequate resolution required for a compact monolithic neutron directional detector. However, using a light-field-based readout for a neutron camera requires incorporating an ultra-low-noise light sensor, which is beyond the scope of this project. We also initiated the development of a 3D light-field-based reconstruction algorithm tailored to sparse scenes, as expected from particle interactions in a scintillator medium. Additionally, we demonstrated the capability of the algorithm to replicate the ground truth. Finally, we began the development of a neutron directional detector simulation to determine the performance criteria for light-field-based reconstruction that allows for good neutron directional reconstruction. This Feasibility Study has led to a successful follow-up project under the DNN R&D innovation portfolio starting May 2024.

42 ENGINEERING↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Modulating spin-valley relaxation in WSe 2 with variable thickness VOPc layers

Combining the synthetic tunability of molecular compounds with the optical selection rules of transition metal dichalcogenides (TMDCs) that derive from spin-valley coupling could provide interesting opportunities for the readout of quantum information. However, little is known about the electronic and spin interactions at such interfaces and the influence on spin-valley relaxation. Here, in this work, vanadyl phthalocyanine (VOPc) molecular layers are thermally evaporated on WSe 2 to explore the effect of molecular layer thickness on excited-state spin-valley polarization. The thinnest molecular layer supports an interfacial state which destroys the spin-valley polarization almost instantaneously, whereas a thicker molecular layer results in longer-lived spin-valley polarization than the WSe 2 monolayer alone. The mechanism appears to involve a tightly bound species at the molecule/TMDC interface that strengthens exchange interactions and is largely avoided in thicker VOPc layers that isolate electrons from WSe 2 holes.

2D materials↗

Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two approaches for the optical isolation of cells: "megatiles" with grooved boundaries between cells, and a 3D-printed plastic frame hosting individual cells. Further, we found that the latter suppresses optical crosstalk to negligible levels while providing an easier assembly method. Overall, these performance studies can help inform calorimeter design and realistic simulations of 5D showers (time, energy, position) for the EIC and other experiments.

47 OTHER INSTRUMENTATION↗

Harnessing the Spin-Flip Radiative Lifetimes of Optically Addressable Molecular Qubits

Optically addressable molecular qubits based on spin-flip (SF) emissive transitions are promising candidates for quantum technologies due to their sharp luminescence lines and tunable optical-spin interfaces. Yet, the microscopic mechanisms controlling the spin-flip radiative lifetime of SF emitters, a key property for efficient spin readout, remain largely unexplored. Here, we present a computational study of several Cr 4+ and Mo 4+ pseudotetrahedral molecular qubits, and we identify chemical and structural features that influence the transition dipole moment associated with the SF emission, which, in turn, governs the SF radiative lifetime. We find that the magnitude of the dipole moment is governed by the multireference character of the spin-flip excited-state wave function, which can be modulated by tuning the energy separation between the d orbitals of the metal and the spin-pairing energy. Both parameters are sensitive to molecular symmetry, metal–ligand bond covalency, and bond anisotropy and leave room for modulation via ligand and metal design, as well as applied strain, which is relevant for sensing applications. Our findings provide a mechanistic framework for understanding and tuning the spin-flip radiative behavior of molecular qubits and SF emitters that may guide future advances in quantum information science.

molecular qubits↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Antisite defect qubits in monolayer transition metal dichalcogenides

Abstract Being atomically thin and amenable to external controls, two-dimensional (2D) materials offer a new paradigm for the realization of patterned qubit fabrication and operation at room temperature for quantum information sciences applications. Here we show that the antisite defect in 2D transition metal dichalcogenides (TMDs) can provide a controllable solid-state spin qubit system. Using high-throughput atomistic simulations, we identify several neutral antisite defects in TMDs that lie deep in the bulk band gap and host a paramagnetic triplet ground state. Our in-depth analysis reveals the presence of optical transitions and triplet-singlet intersystem crossing processes for fingerprinting these defect qubits. As an illustrative example, we discuss the initialization and readout principles of an antisite qubit in WS 2 , which is expected to be stable against interlayer interactions in a multilayer structure for qubit isolation and protection in future qubit-based devices. Our study opens a new pathway for creating scalable, room-temperature spin qubits in 2D TMDs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time bioelectronic sensing of environmental contaminants

Real-time chemical sensing is crucial for applications in environmental and health monitoring. Biosensors can detect a variety of molecules through genetic circuits that use these chemicals to trigger the synthesis of a coloured protein, thereby producing an optical signal. However, the process of protein expression limits the speed of this sensing to approximately half an hour, and optical signals are often difficult to detect in situ. Here we combine synthetic biology and materials engineering to develop biosensors that produce electrical readouts and have detection times of minutes. Here we programmed Escherichia coli to produce an electrical current in response to specific chemicals using a modular, eight-component, synthetic electron transport chain. As designed, this strain produced current following exposure to thiosulfate, an anion that causes microbial blooms, within 2 min. This amperometric sensor was then modified to detect an endocrine disruptor. The incorporation of a protein switch into the synthetic pathway and encapsulation of the bacteria with conductive nanomaterials enabled the detection of the endocrine disruptor in urban waterway samples within 3 min. Our results provide design rules to sense various chemicals with mass-transport-limited detection times and a new platform for miniature, low-power bioelectronic sensors that safeguard ecological and human health.

59 BASIC BIOLOGICAL SCIENCES↗

High-speed two-dimensional terahertz spectroscopy with echelon-based shot-to-shot balanced detection

By using a reflective-echelon-based electro-optic sampling technique and a fast detector, we develop a two-dimensional terahertz (THz) spectrometer capable of shot-to-shot balanced readout of THz waveforms at a full 1-kHz repetition rate. To demonstrate the capabilities of this new detection scheme for high-throughput applications, we use gas-phase acetonitrile as a model system to acquire two-dimensional THz rotational spectra. The results show a two-order-of-magnitude speedup in the acquisition of multidimensional THz spectra when compared to conventional delay-scan methods while maintaining accurate retrieval of the nonlinear THz signal. Our report presents a feasible solution for bringing the technique of multidimensional THz spectroscopy into widespread practice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsed Magnetic Gradiometry in Earth's Field [Poster]

We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spatially separated magnetometers. Operation of the gradiometer in multiple field orientations is discussed. The noise floor is measured as low as 25$\frac{fT}{\sqrt{Hz-cm}}$ in a room without magnetic shielding.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Results from ADRIANO2 Test Beams

A novel high-granularity, dual-readout calorimetric technique (ADRIANO2) is under development as part of the research program of T1604 Collaboration. (Talk Presented at the 19th International Conference on Calorimetry in Particle Physics (CALOR 2022), University of Sussex, Sussex, UK, 16–20 May 2022). The building block of such a calorimeter consists of a pair of optically isolated, small size tiles made of scintillating plastic and lead glass. The prompt Čerenkov light from the glass can be exploited to perform high resolution timing measurements, while the high granularity provides good resolution of the spatial components of the shower. Dual-readout compensation and particle flow techniques can be applied simultaneously to the scintillation and to the Čerenkov section, providing excellent energy resolution as well as PID particle identification. These characteristics make ADRIANO2 a 6-D detector, suited for High Energy as well as High Intensity experiments. A report on the status of the ADRIANO2 project, preliminary measurements of light yield, and current and future R&D plans by T1604 Collaboration are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress toward picosecond on-chip magnetic memory

Here, we offer a perspective on the prospects of ultrafast spintronics and opto-magnetism as a pathway to high-performance, energy-efficient, and non-volatile embedded memory in digital integrated circuit applications. Conventional spintronic devices, such as spin-transfer-torque magnetic-resistive random-access memory (STT-MRAM) and spin–orbit torque MRAM, are promising due to their non-volatility, energy-efficiency, and high endurance. STT-MRAMs are now entering into the commercial market; however, they are limited in write speed to the nanosecond timescale. Improvement in the write speed of spintronic devices can significantly increase their usefulness as viable alternatives to the existing CMOS-based devices. In this article, we discuss recent studies that advance the field of ultrafast spintronics and opto-magnetism. An optimized ferromagnet–ferrimagnet exchange-coupled magnetic stack, which can serve as the free layer of a magnetic tunnel junction (MTJ), can be optically switched in as fast as ~3 ps. Integration of ultrafast magnetic switching of a similar stack into an MTJ device has enabled electrical readout of the switched state using a relatively larger tunneling magnetoresistance ratio. Purely electronic ultrafast spin–orbit torque induced switching of a ferromagnet has been demonstrated using ~6 ps long charge current pulses. We conclude our Perspective by discussing some of the challenges that remain to be addressed to accelerate ultrafast spintronics technologies toward practical implementation in high-performance digital information processing systems.

42 ENGINEERING↗

A novel silicon photomultiplier readout architecture for low-light applications

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light applications, allows the use of a relatively high SiPM operating voltage. This maximizes photon detection efficiency and minimizes gain/efficiency voltage-dependence while eliminating direct optical cross-talk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coherent Control over Nuclear Hyperpolarization Using an Optically Initializable Chromophore-Radical System

Chromophore radicals (CR) are emerging as important components for molecular quantum information science (QIS), especially in the context of quantum sensing. Here, we demonstrate that the optically hyperpolarized electrons in a 1,6,7,12-tetrakis(4-tert-butylphenoxy)-perylene-3,4,9,10-bis(dicarboximide) (tpPDI) covalently linked to a partially deuterated 1,3-bis(diphenylene)-d 16 -2-phenylallyl radical (BDPA-d 16 ) can be coherently manipulated via pulsed dynamic nuclear polarization (DNP) methods to transfer polarization to nuclear spins and back. Under light illumination at 85 K, electron hyperpolarization in BDPA is enhanced 2.1- to 2.4-fold over thermal polarization and lasts for more than 100 ms. By applying nuclear orientation via electron spin-locking (NOVEL) DNP, this optically amplified electron hyperpolarization was successfully transferred to a 1 H nuclear spin within the CR system and efficiently returned to the electron spin for readout via reverse-NOVEL. The NOVEL transfer efficiency of 65% amounts to a 688-fold nuclear spin hyperpolarization of the target nuclear spin, considering the 2.1-fold electron spin hyperpolarization. This reversible coherent manipulation of hyperpolarization transfer highlights the utility of CR systems to initialize and read out nuclear spin states in a disordered matrix at moderate cryogenic temperatures. Coupled with CRs’ environmental compatibility, tunability, and precise state initialization, these results highlight the promising role of nuclear spins in CRs for QIS applications, including quantum sensing and memory.

charge transfer↗

The CMS Barrel Calorimeter Processor demonstrator (BCPv1) board evaluation

For the CERN LHC phase 2, the barrel region of the CMS electromagnetic (ECAL EB) and hadronic calorimeters (HCAL HB) require new back-end electronics for their readout. To this purpose, a first version of the ATCA-based blade, the Barrel Calorimeter Processor (BCPv1), has been developed. The performance of the optical links as well as clock distribution are also presented here. Here, the BCPv1 has been tested together with front-end and trigger boards, as well as with the new DAQ and TCDS Hub (DTH) [1], to demonstrate that the BCPv1 meets the required specifications.

47 OTHER INSTRUMENTATION↗