Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

NASA’s PACE Ocean Color Instrument Thermal Design Evolution: from Goddard’s Instrument Design Lab through Flight Development

NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, set to launch in 2024, seeks to provide data continuity for the ocean color, aerosol and cloud measurements acquired by NASA’s on-orbit Earth Science observatories since the 1990s. It will accomplish this through its Ocean Color Instrument (OCI), an optical spectrometer being developed for hyper-spectral measurements in the ultraviolet-to-near-infrared band between 340 nm and 2260 nm. Although OCI’s instrument architecture will provide greater insight and resolution than its predecessors in this wavelength range, the engineering required to achieve this also poses a greater challenge. In thermal engineering, this translates to a more complex thermal control approach to address high heat dissipations, stringent stabilities, the volume of heat that requires transport, and changing thermal environments due to tilting of the entire instrument ±20° twice per orbit. This current work explores how the PACE OCI instrument design has evolved from its initial conception in NASA Goddard’s Instrument Design Laboratory (IDL) to the current iteration of its flight design. The IDL studies explored three separate instrument configurations and two spatial resolutions per configuration, which were then down selected to a single instrument type and spatial resolution for flight instrument development. OCI subsequently went through major project milestones, including Preliminary Design Review (PDR), Critical Design Review (CDR), Pre-Environmental Review (PER) and Pre-Ship Review (PSR), with significant design updates along the way. This paper aims to provide a comprehensive account of OCI’s thermal control architecture evolution and the engineering drivers that have shaped it, with the goal of identifying trends spanning the full instrument development timeline to inform and advance future instrument thermal designs.

PACE↗

NASA’s PACE Ocean Color Instrument Thermal Design Evolution: from Goddard’s Instrument Design Lab through Flight Development

NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, set to launch in 2024, seeks to provide data continuity for the ocean color, aerosol and cloud measurements acquired by NASA’s on-orbit Earth Science observatories since the 1990s. It will accomplish this through its Ocean Color Instrument (OCI), an optical spectrometer being developed for hyper-spectral measurements in the ultraviolet-to-near-infrared band between 340 nm and 2260 nm. Although OCI’s instrument architecture will provide greater insight and resolution than its predecessors in this wavelength range, the engineering required to achieve this also poses a greater challenge. In thermal engineering, this translates to a more complex thermal control approach to address high heat dissipations, stringent stabilities, the volume of heat that requires transport, and changing thermal environments due to tilting of the entire instrument ±20° twice per orbit. This current work explores how the PACE OCI instrument design has evolved from its initial conception in NASA Goddard’s Instrument Design Laboratory (IDL) to the current iteration of its flight design. The IDL studies explored three separate instrument configurations and two spatial resolutions per configuration, which were then down selected to a single instrument type and spatial resolution for flight instrument development. OCI subsequently went through major project milestones, including Preliminary Design Review (PDR), Critical Design Review (CDR), Pre-Environmental Review (PER) and Pre-Ship Review (PSR), with significant design updates along the way. This paper aims to provide a comprehensive account of OCI’s thermal control architecture evolution and the engineering drivers that have shaped it, with the goal of identifying trends spanning the full instrument development timeline to inform and advance future instrument thermal designs.

PACE↗

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology): Enabling Technology for Missions to the Venus Clouds

AERACEPT (AErosol Rapid Analysis Combined Entry Probe/sonde Technology) is an early-stage technology allowing a single aeroshell body to act as both an entry vehicle and aerosol-sampling passive descent sonde. AERACEPT does not require heat shield separation, deployable parachutes, or descent control, thus reducing the mass, volume, and complexity of planetary aerosol sampling. AERACEPT is particularly well suited for a Venus mission, where the particles of greatest interest are within the subsonic descent regime. AERACEPT uses the aeroshell’s own velocity to drive aerosol capture and separation through a series of embedded inlets. It takes advantage of recently developed thermal protection materials (3D-CC and HEEET) in combination with heritage aerosol sampling technologies from both planetary and airborne science (high-speed inlets and particle separation). The trade space for a given descent trajectory includes the particle capture efficiency for a given size, the bias introduced in the sampled particle size and concentration distributions, and the thermal alteration experienced by the particles during their brief exposure to the internal flow environment. AERACEPT is included in the Nephele mission concept study for a small spacecraft targeting the Venus middle and lower cloud layers. Nephele complements larger missions targeting Venus atmospheric gas analysis, such as DAVINCI and Venera-D, by specifically targeting cloud and haze particles. Because of the short lifetime of the probe in the lower atmosphere, Nephele requires a fast cadence of analysis of the captured particles, and includes the VOLTR dual optical spectrometer (SERS/LIBS) as part of its notional payload. Preliminary modeling based on the Nephele trajectory at 63 km to 39 km indicates AERACEPT can limit sample heating to 30-60 K above ambient. A modified particle tracking model has been implemented to estimate capture efficiency of particles larger than 0.1 µm and total sample volume as part of an inlet and interal flow path geometry trade study. Further modeling and empirical testing is underway to improve these estimates.

AERACEPT↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH2) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment.

plasma↗

Optical Alignment and Diffraction Analysis for AIRES: An Airborne Infrared Echelle Spectrometer

The optical design is presented for a long-slit grating spectrometer known as AIRES (Airborne InfraRed Echelle Spectrometer). The instrument employs two gratings in series: a small order sorter and a large steeply blazed echelle. The optical path includes four pupil and four field stops, including two narrow slits. A detailed diffraction analysis is performed using GLAD by Applied Optics Research to evaluate critical trade-offs between optical throughput, spectral resolution, and system weight and volume. The effects of slit width, slit length, oversizing the second slit relative to the first, on- vs off-axis throughput, and clipping at the pupil stops and other optical elements are discussed.

Haas, Michael R.↗

Planar Rowland spectrometer for fiber-optic wavelength demultiplexing

A planar Rowland spectrometer was fabricated and characterized as a wavelength demultiplexer for multimode fiber-optic applications. The spectrometer consisted of a planar multimode glass waveguide with two curved end faces and a cylindrical concave attached to one of the end faces. Semiconductor lasers with wavelengths between 0.825 and 0.845 micron were used for the measurements. Cross-talk isolation between two adjacent fibers with center-to-center separation of 175 microns (100 A in wavelength difference) was measured to be 18 dB. The device's performance was limited by grating diffraction efficiency, optical aberration, waveguide dispersion, and waveguide losses.

Yen, H. W.↗

Electro-Optical Imaging Fourier-Transform Spectrometer

An electro-optical (E-O) imaging Fourier-transform spectrometer (IFTS), now under development, is a prototype of improved imaging spectrometers to be used for hyperspectral imaging, especially in the infrared spectral region. Unlike both imaging and non-imaging traditional Fourier-transform spectrometers, the E-O IFTS does not contain any moving parts. Elimination of the moving parts and the associated actuator mechanisms and supporting structures would increase reliability while enabling reductions in size and mass, relative to traditional Fourier-transform spectrometers that offer equivalent capabilities. Elimination of moving parts would also eliminate the vibrations caused by the motions of those parts. Figure 1 schematically depicts a traditional Fourier-transform spectrometer, wherein a critical time delay is varied by translating one the mirrors of a Michelson interferometer. The time-dependent optical output is a periodic representation of the input spectrum. Data characterizing the input spectrum are generated through fast-Fourier-transform (FFT) post-processing of the output in conjunction with the varying time delay.

Chao, Tien-Hsin↗

Cloud microstructure as determined by an optical cloud particle spectrometer.

Use of an improved single-particle light-scattering instrument for measurement of cloud microstructure in field studies. Cloud particle size and number information is measured over 12 sizing intervals, in the range from 4 to 85 microns in diameter. The microstructure can be observed in real time and with a spatial resolution not previously reported. The general features of water cloud droplet size and number distributions are consistent with previous direct capture and replication studies. The transition from water to ice phase regions in cumuliform clouds can be inferred from dramatic changes observed in the distribution features. Results are also presented for stratus and cirrus cloud penetrations.

Ryan, R. T.↗

Infrared fiber coupled acousto-optic tunable filter spectrometer

A spectrometer design is introduced which combines an acoustooptic tunable filter (AOTF) and IR-transmitting flouride-glass fibers. The AOTF crystal is fabricated from TeO2 and permits random access to any wavelength in less than 50 microseconds, and the resulting spectrometer is tested for the remote analysis of gases and hydrocarbons. The AOTF spectrometer, when operated with a high-speed frequency synthesizer and optimized algorithms, permits accurate high-speed spectroscopy in the mid-IR spectral region.

Levin, K. H.↗

Fine Pitch Grids for an X-Ray Solar Imaging Spectrometer Fabricated by Optical Lithography and XeF2 Etching

Fine-pitch, sub-collimating X-ray grids have been developed for an instrument in the High Energy Solar Spectroscopic Imager , a proposed NASA mission. In addition to high-energy x- rays, the instrument requires collimation of photons with energies of less than 4 keV such that free-standing grids are required that have no material between the grid slats. Fabrication of these grids is described.

x-ray↗

Two-Frequency Electro-Optic Gas-Correlation Spectrometer

Acoustical modulator not necessary. Two-frequency electro-optic gas-correlation spectrometer relatively simple. Illumination provided by ordinary lamp, no moving parts, and filtered output of detector is beat-frequency signal directly proportional to correlation between spectra of gases in cells.

Margolis, Jack S.↗

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-0IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 pm (1000 -4000 cm-') to allow high-resolution, high-speed hyperspectral imaging applications [l-51. One application will be theremote sensing of the measurement of a large number of different atmospheric gases simultaneously in the sameairmass. Due to the use of a combination of birefiingent phase retarders and multiple achromatic phase switches toachieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventionalFourier transform spectrometer but without any moving parts. In this paper, the principle of operations, systemarchitecture and recent experimental progress will be presen.

solild state imaging Fourier tranform spectrometer↗

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-O IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 micron (1000-4000/cm) to allow high-resolution, high-speed hyperspectral imaging applications. One application will be the remote sensing of the measurement of a large number of different atmospheric gases simultaneously in the same airmass. Due to the use of a combination of birefringent phase retarders and multiple achromatic phase switches to achieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventional Fourier transform spectrometer but without any moving parts. In this paper, the principle of operations, system architecture and recent experimental progress will be presented.

liquid crystal achromatic phase switch↗

Multilaser Herriott Cell for Planetary Tunable Laser Spectrometers

Geometric optics and matrix methods are used to mathematically model multilaser Herriott cells for tunable laser absorption spectrometers for planetary missions. The Herriott cells presented accommodate several laser sources that follow independent optical paths but probe a single gas cell. Strategically placed output holes located in the far mirrors of the Herriott cells reduce the size of the spectrometers. A four-channel Herriott cell configuration is presented for the specific application as the sample cell of the tunable laser spectrometer instrument selected for the sample analysis at Mars analytical suite on the 2009 Mars Science Laboratory mission.

continuous-wave↗

Optical processing of imaging spectrometer data

The data-processing problems associated with imaging spectrometer data are reviewed; new algorithms and optical processing solutions are advanced for this computationally intensive application. Optical decision net, directed graph, and neural net solutions are considered. Decision nets and mineral element determination of nonmixture data are emphasized here. A new Fisher/minimum-variance clustering algorithm is advanced, initialization using minimum-variance clustering is found to be preferred and fast. Tests on a 500-class problem show the excellent performance of this algorithm.

Liu, Shiaw-Dong↗

JPL activities on development of acousto-optic tunable filter imaging spectrometer

Recent activities of JPL in the development of a new type of imaging spectrometers for earth observation and planetary exploration are reported. This instrument uses the acousto-optic tunable filter (AOTF) as high resolution and fast programmable bandpass filter. AOTF operates in the principle of acousto-optic interaction in an anisotropic medium. This filter can be tuned in sequential, random, and multiwavelength access modes, providing observational flexibility. The diffraction process in the filter generates two diffracted monochromatic beams with polarization orthogonal to each other, creating a unique capability to measure both polarimetric and spectral properties of the incoming light simultaneously with a single instrument. The device gives wide wavelength operations with reasonably large throughput. In addition, it is in a compact solid-state structure without moving parts, providing system reliability. These attractive features give promising opportunities to develop a new generation of airborne/spaceborne and ground, real-time, imaging spectrometer systems for remote sensing applications.

Cheng, Li-Jen↗

Use of the Airborne Visible/Infrared Imaging Spectrometer to Calibrate the Optical Sensor on Board the Japanese Earth Resources Satellite-1

In this paper, we describe an experiment to calibrate the Optical Sensor on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

spaceborne↗