Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Measurement of engine-oil fuel dilution using laser induced florescence spectroscopy

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil, or fuel in oil (FiO). Fuel dilution of oil is believed to be one of the underlying mechanisms that promotes low speed pre-ignition (LSPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of transient measurements, the LIF technique resolves transient dilution on the minutes time scale, making it possible to study the relation between FiO and LSPI. The measurement is based on adding a dye (ca. 500 ppm) to the fuel and monitoring for its presence in the oil via LIF. The instrument contains a 532-nm laser diode, and a spectrometer to resolve the LIF spectra. A fiber-optic assembly links the instrument to the engine measurement location; the probe is in a Y-configuration with the six fibers around one on a common probe end that connects to the engine; the Y-assembly legs are connected to the instrument; the two legs are the six fibers for transporting the laser light, and the single fiber for the fluorescence. We have expanded on our previous work (Parks et al, SAE paper 2007-01-4108, 2007), by demonstrating the diagnostic technique with to measure transient oil dilution on a 2.0-liter GM ECOTEC LNF single cylinder SI engine. The proposed LIF diagnostic will be critical in studying oil-dilution correlation with LSPI events.

Neupane, Sneha↗

Low-cost, portable optical sensors for critical mineral prospecting and process monitoring

A combination of projected demand increases for economically critical minerals and a monopolistic global marketplace for these minerals has caused concern over supply chain vulnerabilities, which would impact energy, national defense, and advanced technology production. Domestic production of critical minerals is hindered by expensive and non-portable methods for analyzing metal concentration, which is vital both for resource prospecting and process monitoring. Here, a suite of luminescent materials along with portable instrumentation is presented for fluorescence-based detection of trace concentrations of critical minerals (cobalt, rare earth elements, and aluminum) as well as common gangue metals that are removed during processing (iron and aluminum). A metal-organic framework comprised of zinc, adenine, and trimesic acid immobilized on a fiber optic tip is capable of sensing part-per-billion concentrations of terbium, europium, dysprosium, and samarium through a sensitization approach, in which individual elements produce characteristic emission bands enabling multiple rare earths to be simultaneously detected and distinguished. A deep-UV light emitting diode is used as the excitation source, while a portable spectrometer is used to detect the emitted light. A similar optical set-up is coupled with two different carbon dot materials, which can detect low part-per-million concentrations of cobalt and iron in acidic environments. Metal-organic framework thin films comprised of copper and 2-aminoterephthalic acid are used in tandem with a portable optical set-up to further detect aluminum, with successful deployment in real fly ash leachates. Taken together, these technologies provide an inexpensive and sensitive path towards characterizing economically critical metals.

characterization and extraction of rare earth elem↗

Dynamic computational optical fringe mitigation in tunable laser absorption spectroscopy

In optical spectroscopic systems where unwanted optical scattering cannot be eliminated, Fabry-Pérot etalons cause unpredictable changes in the spectral background. Frequent system calibration is then required to maintain the desired measurement accuracy, which presents a major limitation to the spectrometer. We introduce a computational approach to mitigate the adverse effects of optical fringing without hardware modifications. Motivated by experimental observations of complicated fringe behaviors, we simplify the problem by decomposing the fringe background into component etalons that can be addressed according to their individual characteristics. The effectiveness of the proposed method is demonstrated on a silicon photonic methane sensor, where accurate measurements of methane concentration are obtained from spectral data strongly affected by optical fringes.

Teng, Chu C. (ORCID:0000000152744835)↗

Portable fiber optic sensor for rare earth elements and other critical metals using photoluminescence methods

Rare earth elements and other metals are vital to a range of technologies that are used in the energy and defense sectors. However, monopolistic market conditions have caused significant concern over the stability of the critical metal supply chain, and this has spurred extensive efforts in many nations to produce these metals domestically, both from conventional sources such as mining and well as from unconventional sources such as coal and its utilization byproducts. Slow and expensive characterization methods pose a significant barrier for both metals prospecting and process monitoring. A promising solution to this challenge is the development of highly sensitive luminescent sensors for metals, which can offer low costs, portability, and sensitivity. Anionic zinc adeninate metal-organic frameworks (BioMOFs) are known to distinguishing and detect part-per-billion levels of terbium, europium, samarium, and dysprosium in water by sensitizing the narrow, element-specific emission bands from these lanthanides. Here, a BioMOF material is immobilized onto a large diameter, solarization-resistant fiber optic tip integrated with a portable, low-cost spectrometer for rare earth element sensing. Immobilizing the sensing material on fiber instead of dispersing the sensing material in solution offers several advantages: it facilitates solvent removal, which enhances luminescent signal from the sensitized lanthanides, and it also allows the BioMOF to be recycled for multiple uses. The sensing system was deployed on a simulated process stream and exhibited qualitative agreement with inductively-coupled plasma mass spectrometry for terbium and europium detection, highlighting the potential for the sensing system to be deployed for real-world applications. By using different sensing materials, the same portable sensor may be deployed to detect other energy relevant metals such as cobalt, providing a cost-effective and sensitive platform for critical metal characterization.

Crawford, Scott↗

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James↗

First Offline Results from the S3 Low-Energy Branch

We present the first results obtained from the S3 Low-Energy Branch, the gas cell setup at SPIRAL2-GANIL, which will be installed behind the S3 spectrometer for atomic and nuclear spectroscopy studies of exotic nuclei. The installation is currently being commissioned offline, with the aim to establish optimum conditions for the operation of the radio frequency quadrupole ion guides, mass separation and ion bunching, providing high-efficiency and low-energy spatial spread for the isotopes of interest. Transmission and mass-resolving power measurements are presented for the different components of the S3-LEB setup. In addition, a single-longitudinal-mode, injection-locked, pumped pulsed-titanium–sapphire laser system has been recently implemented and is used for the first proof-of-principle measurements in an offline laser laboratory. Laser spectroscopy measurements of erbium, which is the commissioning case of the S3 spectrometer, are presented using the 4f126s23H6→4f12(3H)6s6p optical transition.

Romans, Jekabs (ORCID:0000000197427745)↗

Design and performance of a multi-terahertz Fourier transform spectrometer for axion dark matter experiments

Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Narrow-bandwidth tunable optical filter stabilized by Newton’s rings fringe analysis

The resolution of grating spectrometers is insufficient to resolve many features present in the emission spectra of solid-state quantum emitters. Spectral resolution may be improved by inserting a Fabry–Perot interferometer (FPI) whose length is tuned by a piezoelectric actuator. Yet piezo creep and thermal fluctuations cause instability that makes this solution unsuitable for measurement times longer than tens of seconds. To overcome this challenge, we employ active feedback derived from the Newton’s rings interference pattern formed by the reflection of a single-frequency laser from the FPI cavity. The resulting FPI transmission frequency is stable to within 50 MHz over several hours.

KC, Raju Bhai (ORCID:0000000267406588)↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

Integrated Silicon Fourier Transform Spectrometer with Broad Bandwidth and Ultra‐High Resolution

An ultra-high resolution Fourier transform spectrometer (FTS) realized in silicon photonic platform that can operate with broad band, narrow band as well as a combination of broad band and narrow band signals is reported. The ultra-high resolution of the spectrometer is achieved by exploiting multiple techniques: a Michelson interferometer (MI) structure to increase the optical path delay (OPD), a hybrid waveguide design to reduce insertion loss, an optimized heater and air trenches to achieve higher thermal efficiency. Here, to further increase the OPD of the spectrometer to increase its resolution, a novel multiple interferometers approach is employed which combines balanced MI with N statically imbalanced MIs, thereby increasing the OPD of a single MI by factor of N + 1. An FTS spectrometer consisting of N = 2 such MIs is fabricated and experimentally characterized using unknown broad bandwidth input signal spectra of about 180 nm centered around 1550 nm, a narrow line laser input signal, and a combination of broad and narrow band signals demonstrating spectral resolution of about 0.16 nm.

Li, Ang↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

Three-beam hybrid fs/ps coherent anti-Stokes Raman scattering of rotation–vibration non-equilibrium

In this work, we demonstrate time-resolved rotational and vibrational temperature measurements to probe plasma non-equilibrium through a simple three-beam hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system. A single pump/Stokes pair is employed to generate both the pure-rotational and ro-vibrational Raman coherence. A novel phase-matching scheme, to our knowledge, is employed to spatially overlap the two CARS signals, simplifying the optical design and allowing signal selection by tuning a single spectrometer grating. Measurements were performed near the electrodes in a N 2 DC glow discharge. Both the rotational temperature and the vibrational populations up to $v$ = 8 were calculated from the separately measured single-shot pure-rotational and ro-vibrational CARS spectra. Strong rotation–vibration non-equilibrium was observed at both electrodes, with the cathode showing higher vibrational and rotational temperatures. In addition, non-Boltzmann behaviors were observed at both electrodes. This simplified approach enables measurements of rotational and vibrational temperatures with high spatial resolution in non-equilibrium flows.

42 ENGINEERING↗

Modeling Wavelength Dependent Mid-infrared (5.5–25 μm) Optical Constants of Silicate Glasses: A Genetic Algorithm Approach

Wavelength-dependent mid-infrared (400–1,800 cm -1 ; 5.56–25 μm) optical constants (real and imaginary indices of refraction; n and k) are determined using reflectance spectra at a spectral sampling of 4 cm -1 for several silicate glasses of varying SiO 2 wt% which include (a) basaltic volcanic glass from Kilauea, Hawaii, (b) synthetic andesite, (c) two synthetic dacites, (d) obsidian volcanic glass from Mount Lassen, California, (e) synthetic rhyodacite, and (f) rhyolitic volcanic glass from Mexico. Because glasses are optically isotropic, no specific orientation was required for spectral measurements, and polished glass samples were measured at random orientations using micro-FTIR spectrometer. Lorentz-Lorenz dispersion theory and Fresnel reflectance model for high symmetry materials were used to model the optical constants by optimizing oscillator parameters in modeled spectra to match laboratory spectra. A genetic algorithm (GA) approach automatically finds the natural oscillators and their parameters for each spectrum, and then uses these parameters in a non-linear least squares optimization routine. The study compared spectral parameters such as Christiansen feature, reststrahlen bands (RBs), and the peaks centered around 860–1,100 (peak 1) and 400–480 cm -1 (peak 2) of n and k to their respective SiO 2 wt% of the glasses. CF, RBs, peak 1 of n and k, and peak 2 of n shift to higher wavenumbers with increased SiO 2 wt%, whereas peak 2 of k shifts to lower wavenumbers with increased SiO 2 wt%. Derived optical constants of these glasses will improve quantitative abundance mapping of volcanic materials on the surfaces of silicate targets in the Solar System.

58 GEOSCIENCES↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

Gas-phase oxidation and nanoparticle formation in multi-element laser ablation plumes

The evolution from gas-phase oxidation to nanoparticle and agglomerate formation was studied in nanosecond laser-produced plasmas of a multi-principal element alloy target in air. Here gas-phase oxidation of plasma species was monitored in situ via optical emission spectroscopy, while a custom-built single particle mass spectrometer was used to measure size and compositions of agglomerated nanoparticles formed in laser ablation plumes. Ex situ analysis employing transmission electron microscopy was used to study nanoparticle morphology, crystal structure, and element distribution at the nanoscale. Emission spectra indicate that gas-phase oxidation of elements in the alloy target are formed at varying times during plume evolution, and mass spectrometry results indicate fractal agglomerates contain all principal alloying elements and their oxides. Finally, electron microscopy characterization illustrates that these agglomerates consist of multiple material types: sub-10 nm diameter amorphous, multi-element nanoparticles, ≈10–30 nm diameter Ti-rich crystalline oxide nanoparticles, and ejected base material. Results highlight that the multi-component target composition impacts molecular formation in the gas phase and the morphology, composition, and structure of nanoparticles and agglomerates formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗