Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscillator spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Five-minute P Modes Detected in Doppler Shift Measurement on Alpha Centauri

A spectrophotometer using the principle of optical resonance spectroscopy, designed for the goal of identifying radial and weakly non radial eigenmodes in the five minute range in the case of stars, is discussed. The conclusion of the first test of this new instrument was that if the observation can be photon noise limited (i.e., in total absence of any instrumental source of noise), the five-minute solar oscillation could still be detected by removing the Sun far enough for its magnitude to become zero or one. Such a situation is very closely represented by the observation of Alpha Centauri A, because it is a G2 V star, very similar to the Sun, with a mass of 1.1 in solar unit. Six nights were granted to this program on a 3.6m telescope, from 22 to 28 May 1983. Two and half nights provided over 20 hours of data of photometric quality good enough for analysis.

Fossat, E.↗

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

New Measurements of Doubly Ionized Iron Group Spectra by High Resolution Fourier Transform and Grating Spectroscopy

We report new measurements of doubly ionized iron group element spectra, important in the analysis of B-type (hot) stars whose spectra they dominate. These measurements include Co III and Cr III taken with the Imperial College VUV Fourier transform (FT) spectrometer and measurements of Co III taken with the normal incidence vacuum spectrograph at NIST, below 135 nm. We report new Fe III grating spectra measurements to complement our FT spectra. Work towards transition wavelengths, energy levels and branching ratios (which, combined with lifetimes, produce oscillator strengths) for these ions is underway.

Smillie, D. G.↗

Ground-based mm-wave emission spectroscopy for the detection and monitoring of stratospheric ozone

The molecular rotational spectrum of ozone is quite rich in the mm-wave region from 50 to 300 GHz. An apparatus, which was developed primarily for detection and measurement of stratospheric ClO and other trace molecules, is found to be well suited also for the observation of ozone lines. The collecting antenna of the apparatus is a simple mm-waveguide feedhorn. The detector is a superheterodyne mixer using a special high frequency Schottky diode and a klystron local oscillator. The spectrometer is a 256 channel filter bank with 1 MHz resolution per channel. The apparatus is believed to be the first ground-based mm-wave instrument having the capability of obtaining data of sufficient quality to make use of the inversion technique. The ground based radio technique is most sensitive to changes in vertical distribution in the region above 25 km, a region which is difficult to sample by other techniques.

Parrish, A.↗

Photoexcitation and ionization in carbon dioxide - Theoretical studies in the separated-channel static-exchange approximation

Vertical-electronic static-exchange photoexcitation and ionization cross sections are reported which provide a first approximation to the complete dipole spectrum of CO2. Separated-channel static-exchange calculations of vertical-electronic transition energies and oscillator strengths, and Stieltjes-Chebyshev moment methods were used in the development. Detailed comparisons were made of the static-exchange excitation and ionization spectra with photoabsorption, electron-impact excitation, and quantum-defect estimates of discrete transition energies and intensities, and with partial-channel photoionization cross sections obtained from fluorescence measurements and from tunable-source and (e, 2e) photoelectron spectroscopy. Results show that the separate-channel static-exchange approximation is generally satisfactory in CO2.

Padial, N.↗

High-Speed Linear Raman Spectroscopy for Instability Analysis of a Bluff Body Flame

We report a high-speed laser diagnostics technique based on point-wise linear Raman spectroscopy for measuring the frequency content of a CH4-air premixed flame stabilized behind a circular bluff body. The technique, which primarily employs a Nd:YLF pulsed laser and a fast image-intensified CCD camera, successfully measures the time evolution of scalar parameters (N2, O2, CH4, and H2O) in the vortex-induced flame instability at a data rate of 1 kHz. Oscillation of the V-shaped flame front is quantified through frequency analysis of the combustion species data and their correlations. This technique promises to be a useful diagnostics tool for combustion instability studies.

Kojima, Jun↗

A simplified CARS measurement system for rapid determination of temperature and oxygen concentration

A new spectroscopic concept for the rapid determination of temperature and oxygen concentration by CARS (Coherent Anti-Stokes Raman Spectroscopy) was described. The ratio of two spectral regions in the broadband Q-branch spectrum was detected by photomultipliers in a monochromator, which ratio depends on temperature and species concentration. The comparison of the measured data with theory was made using a flat flame burner and an electric furnace, with reasonable results. Various optical techniques for alignment were introduced including a highly efficient, stable dye oscillator. The combination of the spectroscopic concept and the optical techniques will make the CARS measurement system rapid in data processing and simple in optical parts.

Fujii, Shoichi↗

High Electron Mobility SiGe/Si Transistor Structures on Sapphire Substrates

SiGe/Si n-type modulation doped field effect structures and transistors (n-MODFETs) have been fabricated on r-plane sapphire substrates. The structures were deposited using molecular beam epitaxy, and antimony dopants were incorporated via a delta doping process. Secondary ion mass spectroscopy (SIMS) indicates that the peak antimony, concentration was approximately 4 x 10(exp19) per cubic cm. The electron mobility was over 1,200 and 13,000 sq cm/V-sec at room temperature and 0.25 K, respectively. At these two temperatures, the electron carrier densities were 1.6 and 1.33 x 10(exp 12) per sq cm, thus demonstrating that carrier confinement was excellent. Shubnikov-de Haas oscillations were observed at 0.25 K, thus confirming the two-dimensional nature of the carriers. Transistors, with gate lengths varying from 1 micron to 5 microns, were fabricated using these structures and dc characterization was performed at room temperature. The saturated drain current region extended over a wide source-to-drain voltage (V(sub DS)) range, with (V(sub DS)) knee voltages of approximately 0.5 V and increased leakage starting at voltages slightly higher than 4 V.

Alterovitz, Samuel A.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

Report of the heterodyne submillimeter-wave sensors panel

After reviewing the science goals of the Astrotech 21 mission set, and comparing the resulting receiver performance requirements with existing technology, the panel determined that there were significant unmet requirements in four areas: local oscillator power and mixer sensitivity in the Tera-Hz regime, infrared spectrometer channel count, and array technology in any form. A comprehensive development plan has been prepared to provide these capabilities in the time frame needed before technology freeze dates of the respective missions. It was also noted that development of these capabilities has immense payoff for future astrophysics missions, as it opens entire new areas of spectroscopy and imaging in the critical submillimeter wave regime rich in molecular transitions.

Wilson, Robert↗

Internal Heterogeneous Processes in Aluminum Combustion

This paper discusses the aluminum particle combustion mechanism which has been expanded by inclusion of gas dissolution processes and ensuing internal phase transformations. This mechanism is proposed based on recent normal and microgravity experiments with particles formed and ignited in a pulsed micro-arc. Recent experimental findings on the three stages observed in Al particle combustion in air and shows the burning particle radiation, trajectory (streak), smoke cloud shapes, and quenched particle interiors are summarized. During stage I, the radiation trace is smooth and the particle flame is spherically symmetric. The temperature measured using a three-color pyrometer is close to 3000 K. Because it exceeds the aluminum boiling point (2730 K), this temperature most likely characterizes the vapor phase flame zone rather than the aluminum surface. The dissolved oxygen content within particles quenched during stage I was below the detection sensitivity (about 1 atomic %) for Wavelength Dispersive Spectroscopy (WDS). After an increase in the radiation intensity (and simultaneous decrease in the measured color temperature from about 3000 to 2800 K) indicative of the transition to stage II combustion, the internal compositions of the quenched particles change. Both oxygen-rich (approx. 10 atomic %) and oxygen-lean (< 1 %) regions are identified within the particles using back-scattered electron imaging and WDS. During stage II, oscillations are observed in particle radiation and the flame and smoke cloud are distorted from their original spherically-symmetric shape. In stage III, particle radiation continues to exhibit oscillations, but its radiation intensity drops and remains at a nearly constant level. The measured temperature decreases to about 2300 K. Also, larger changes in particle velocities are observed, and oxide caps are found on quenched particle surfaces. While these results showed the correlation between the aluminum particle combustion behavior and the evolution of its internal composition, the change from the spherically symmetric to asymmetric flame shape occurring upon the transition from stage I to stage II combustion could not be understood based only on the fact that dissolved oxygen is detected in the particles. The connection between the two phenomena appeared even less significant because in earlier aluminum combustion studies carried in O2/Ar mixtures, flame asymmetry was not observed as opposed to experiments in air or O2/CO mixtures. It has been proposed that the presence of other gases, i.e., hydrogen, or nitrogen causes the change in the combustion regime.

Dreizin, E. L.↗

Emerging flux, magnetic reconnection, plasma turbulence and waves in the transition zone of the solar atmosphere

Ultraviolet spectroscopy of the solar transition zone, especially Spacelab 2 results, is reviewed. Emerging magnetic flux is considered as the energy source of the solar corona and the solar wind. The conversion of magnetic into kinetic energy is facilitated in the transition zone because of unique conditions. Radiation losses are sufficient to create fast instabilities. Observed nonthermal velocities in spectra of the transition zone indicate the existence of strong plasma oscillations and turbulence. The small filling factor of the transition zone indicates a highly filamentary structure of density, magnetic field strength, and currents, which results in rapid reconnection time scales. Particle acceleration and the heating of the corona are placed in the areas of strong plasma oscillations of the transition zone.

Brueckner, G. E.↗

Discovery of Soft Spectral Component and Transient 22.7s Quasi Periodic Oscillations of SAX J2103.5+4545

XMM-Newton observed SAX J2103.5+4545 on January 6, 2003, while RXTE was monitoring the source. Using RXTE-PCA dataset between December 3, 2002 and January 29, 2003, the spin period and average spin-up rate during the XMM-Newton observations were found to be 354.7940+/-0.0008 s and (7.4 +/- 0.9) x 10(exp -13) Hz/s respectively. In the power spectrum of the 0.9-11 keV EPIC-PN lightcurve, we found quasi periodic oscillations around 0.044 Hz (22.7 s) with an rms fractional amplitude approx. 6.6 %. We interpreted this QPO feature as the Keplerian motion of inhomogeneities through the inner disk. In the X-ray spectrum, in addition to the power law component with high energy cutoff and approx. 6.4 keV fluorescent iron emission line, we discovered a soft component consistent with a blackbody emission with kT approx. 1.9 keV. The pulse phase spectroscopy of the source revealed that the blackbody flux peaked at the peak of the pulse with an emission radius approx. 0.3 km, suggesting the polar cap on the neutron star approx. 6.42 keV was shown to peak at the off-pulse phase, supporting the idea that this feature arises from fluorescent emission of the circumstellar material around the neutron star rather than the hot region in the vicinity of the neutron star polar cap.

Inam, S. C.↗

Line List for the A 2 Π−X 2 Σ + and the B 2 Σ + −X 2 Σ + Band Systems of CaF

The spectral analysis of molecule-rich asymptotic giant branch (AGB) stars is challenging. Although other calcium and fluorine bearing molecules are observed in the microwave and in the visible spectrum of AGB stars, CaF has never been detected, despite favorable chemical equilibrium predictions. Yet, measuring the CaF abundance could give more insight into the fluorine budget of AGB stars and allow better simulation of stellar spectra. In this work, we present an analysis of the visible spectrum of CaF obtained with a Fourier transform spectrometer. CaF A 2 Π−X 2 Σ + and the B 2 Σ + −X 2 Σ + band systems were excited with a hollow cathode discharge. Using previous fluorescence spectroscopy measurements, highly accurate ground state constants, and reasonable extrapolation schemes, the strongest features of CaF in the visible spectrum can be accurately modeled for both band systems. Spectroscopic constants are determined for A 2 Π with v ≤ 16 and for B 2 Σ + with v ≤ 20. Ab initio transition dipole moment curves of both transitions were calculated and scaled, and we provide a line list with Einstein A coefficients and oscillator strengths. This line list can be used to simulate spectra of CaF at temperatures and pressures relevant to astrophysical environments.

Léo Lavy↗

Tunable Heterodyne Receiver from 100 Micron to 1,000 Micron for Airborne Observations

Interest in high resolution spectrometers for the submillimeter wavelength range from 100 micron to 1,000 micron is mostly stimulated by molecular spectroscopy in radioastronomy and atmospheric physics, and by plasma diagnostic experiments. Schottky diodes in waveguide mixer technology and InSb-hot electron bolometers are successfully used in the 0.5 to a few millimeter range whereas tandem Fabry-Perot spectrometers combined with photoconductive detectors (Ge:Sb and Ge:Ga) are used for the 100 micron range. Recent research on heterodyne spectrometers, with Schottky diodes in an open structure mixer and a molecular laser as local oscillators, which can be used over the whole wavelength range is summarized.

Roeser, H. P.↗

Multiplex coherent raman spectroscopy detector and method

A multiplex coherent Raman spectrometer (10) and spectroscopy method rapidly detects and identifies individual components of a chemical mixture separated by a separation technique, such as gas chromatography. The spectrometer (10) and method accurately identify a variety of compounds because they produce the entire gas phase vibrational Raman spectrum of the unknown gas. This is accomplished by tilting a Raman cell (20) to produce a high-intensity, backward-stimulated, coherent Raman beam of 683 nm, which drives a degenerate optical parametric oscillator (28) to produce a broadband beam of 1100-1700 nm covering a range of more than 3000 wavenumber. This broadband beam is combined with a narrowband beam of 532 nm having a bandwidth of 0.003 wavenumbers and focused into a heated windowless cell (38) that receives gases separated by a gas chromatograph (40). The Raman radiation scattered from these gases is filtered and sent to a monochromator (50) with multichannel detection.

Chen, Peter↗

MIMOS II on MER One Year of Mossbauer Spectroscopy on the Surface of Mars: From Jarosite at Meridiani Planum to Goethite at Gusev Crater

The miniaturized Mossbauer (MB) spectrometer MIMOS II [1] is part of the Athena payload of NASA s twin Mars Exploration Rovers "Spirit" (MER-A) and "Opportunity" (MER-B). It determines the Fe-bearing mineralogy of Martian soils and rocks at the Rovers respective landing sites, Gusev crater and Meridiani Planum. Both spectrometers performed successfully during first year of operation. Total integration time is about 49 days for MERA (79 samples) and 34 days for MER-B (85 samples). For curiosity it might be interesting to mention that the total odometry of the oscillating part of the MB drive exceeds 35 km for both rovers.

Klingelhoefer, G.↗

An experiment concept to measure stratospheric trace constituents by Laser Heterodyne Spectroscopy

The concept and techniques of a Laser Heterodyne Spectrometer experiment for measuring the vertical profiles of several stratospheric trace gases are discussed. The goal of the experiment is to develop a laser heterodyne receiver capable of measuring 2-4 gases simultaneously from Spacelab and, ultimately, from free-flying platforms. Sensitivity analyses are currently being performed for tenuous molecules such as ClO, ClONO2, NOCl, HO2, H2O2, and N2O5, although the capability exists for measuring more abundant gases, such as O3, HNO3, N2O, NO2, and CH4. Results indicate that O3 and ClO vertical profiles can be measured with an accuracy equal to or better than 95% and 80%, respectively, over the total profile. Laboratory measurements of the performance characteristics of the local oscillator and heterodyne detector are discussed with reference to 'excess-noise' and Doppler-shift effects.

Allario, F.↗