Convective heating measurement by means of an infrared camera

The development of rapid and accurate wind tunnel techniques to measure convective heating distributions in complex reentry configurations is discussed. Major emphasis was put on the infrared camera technique. Its essence is the measurement of infrared emission from the surface of a wind tunnel model as a function of time. Prior calibration of the infrared camera relates the emission to the surface temperature of the model. The time history of the surface temperature can then be related to the heating rate by standard techniques. The output of the camera is an electrical signal that is tape-recorded in analog form, then digitized and processed by computer, so that automated and relatively rapid data reduction can be accomplished. In addition, the camera produces real-time visual displays of the infrared emission as pictures on an oscilloscope screen. These pictures give immediate indications of hot and cool spots on the model.

Compton, D. L.↗

Vibration-rotation double resonance effects in symmetrical top molecules.

Rotational transitions in symmetrical top molecules in the wavelength regions of 1-3 mm are sufficiently strong to be observed directly on an oscilloscope. Changes in the vibrational level populations induced by laser radiations affect the intensity of the rotational transitions. Observation of the microwave lines under the influence of chopped laser radiation shows a variety of interesting and potentially informative effects. At pressures above a few tenths of a torr the effect of laser radiation is to reduce the microwave response. This is true for all microwave lines at all those laser frequencies which are absorbed by the gas, and this effect is roughly proportional to the absorption coefficient. The rise and decay times of this effect increase with pressure and the the linear dimensions of the absorption cell. At low pressures the microwave response may increase, decrease, or remain unaffected depending on the observed microwave transitions and the specific laser line applied to the gas.

Marantz, H.↗

Use of an infrared-imaging camera to obtain convective heating distributions.

The IR emission from the surface of a wind-tunnel model is determined as a function of time with the aid of an infrared-sensitive imaging camera. Prior calibration of the IR camera relates the emission to the surface temperature of the model. The time history of the surface temperature is then related to the heating rate by standard techniques. The output of the camera is recorded in analog form, digitized, and processed by a computer. In addition, real-time visual displays of the IR emissions are obtained as pictures on an oscilloscope screen.

Compton, D. L.↗

A remote test parameter profile display

Multiplexed digital recording system with simple interface between it and standard commercially available oscilloscopes was developed. System included: rapid set-up, minimum input cabling, low cost, display expansion capability, and portability.

Harrold, J. L.↗

Low-cost clearance indicator for high speed turbomachinery

System consists of hermetically sealed capacitance probe, compact electronic driver, power supply, and oscilloscope and/or voltmeter for readout. System requires no mechanical connection to the rotating parts of turbomachinery, and does not disrupt rotor mainstream flow pattern. It can be effectively used in other applications to measure dynamic clearances between moving and stationary parts.

Evans, R. C.↗

Grain refinement control in gas-shielded arc welding of aluminum tubing

When sections are being welded, operator varies pulse rate of power supply and simultaneously monitors signal on oscilloscope until rate is found which produces maximum arc gas voltage. Remainder of welding is performed with power supply set at this pulse rate, producing desired maximum weld puddle agitation and fine uniform weld of grain structure.

Iceland, W. F.↗

Turbulence measurements in a compressible boundary layer subjected to a shock-wave-induced adverse pressure gradient.

The rms intensities of fluctuating mass flux and total temperature and their correlation coefficients are given for the case of an adiabatic, Mach 4, axisymmetric shock-wave boundary-layer interaction. Data were obtained upstream, within, and downstream of the interaction by the use of constant temperature hot-wire anemometer. Turbulence spectra and quantitative behavior from oscilloscope traces are shown at selected locations. The measurements indicate that certain frequencies of the turbulence are increased as a result of the interaction and that the mass flux and total temperature fluctuations remain highly correlated over most of the boundary layer throughout the interaction. The present data are also transformed to rms intensities of fluctuating static temperature and velocity and compared with existing data obtained in adiabatic flows.

Rose, W. C.↗

A dynamic polariscope for stress wave analysis.

A polariscope for the study of the propagation of stress waves in birefringent sheets is described. Sensitive, fast-responding photomultiplier tubes, a laser light source, and a multiple channel oscilloscope were used for the simultaneous recording of the stress-optic data at several points of the target following impact. A method of separation of stresses and the computation of displacement, strain, and stress is given.

Kinslow, R.↗

System for measuring transients in fluid flow

When test valve is actuated, piston is moved by pressurized fluid, and displacement is monitored by electro-optical tracking system and recorded by oscilloscope camera. Electro-optical monitor produces output voltage proportional to displacement of piston.

Pearson, D. J.↗

Device for recording the 20 Hz - 200 KHz sound frequency spectrum using teletransmission

The device described consists of two distinct parts: (1) The sound pickup system consisting of the wide-frequency band condenser microphone which contains in the same assembly the frequency-modulated oscillator and the output stage. Being transistorized and small, this system can be easily moved, so that sounds can be picked up even in places that are difficult to reach with larger devices. (2) The receiving and recording part is separate and can be at a great distance from the sound pickup system. This part contains a 72 MHz input stage, a frequency changer that gives an intermediate frequency of 30 MHz and a multichannel analyzer coupled to an oscilloscope and a recorder.

Baciu, I.↗

Conductive elastomeric extensometer

An extensometer was used for measuring surface area changes of the human body caused by expansion and contraction of the body. A relatively thin and wide strain responsive conductive elastomeric band was adapted for application to a part of the body, such as around a limb or the trunk of the body. The elastomeric band is incorporated as a resistor in a balanced bridge circuit. Expansion or contraction of the portion of the body on which the elastomeric band is applied causes a change in the resistance of the band and a resultant imbalance of the bridge circuit. The output of the amplifier in volts is suitable for proving the desired reading through a recorder, oscilloscope or voltmeter.

Gause, R. L.↗

Differential phonograms

A new noise measuring method is outlined that is based on electronic analysis of the radiated noise. Non-relevant components are suppressed, while the differential phonogram displayed on the oscilloscope screen discloses the information carrying components. It allows low skilled operators to perform: (1) correct alignment of equipment; (2) detection of incipient failure; and (3) checking of prototypes.

Halpert, E.↗

The initiation of boiling during pressure transients

The initiation of boiling of water on metal surfaces during pressure transients has been investigated. The data were obtained by a new technique in which light beam fluctuations and a pressure signal were simultaneously recorded on a dual beam oscilloscope. The results obtained agreed with those obtained using high speed photography. It was found that, for water temperatures between 90-150 C, the wall superheat required to initiate boiling during a rapid pressure transient was significantly higher than required when the pressure was slowly reduced. This result is explained by assuming that a finite time is necessary for vapor to fill the cavity at which the bubble originates. Experimental measurements of this time are in reasonably good agreement with calculations based on the proposed theory. The theory includes a new procedure for estimating the coefficient of vaporization.

Weisman, J.↗

Nondestructive testing of electro thermal devices

This paper describes the results of a recent investigation into 'thermal time constant' nondestructive testing of high reliability electrical fuses. The use of established nondestructive test technology for examining the quality and firing characteristics of electro-explosive devices has been successfully applied to the inspection and prediction of the functional performance of electrical fuses. The technique requires application of a low level current pulse to the electrical fuse with an oscilloscope display of the curve as generated by the temperature coefficient of resistance feedback. The heating curve of temperature vs time is composed of one predominant thermal time constant, which is the product of the test unit's thermal capacity and thermal resistance. It has been found that the quality of the individual electrical fuse, for instance, the relative condition of the critical internal weld or solder joint, can be examined nondestructively.

Earnest, J. E., Jr.↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

A technique for generating shear waves in cylindrical shells under radial impact

Experimental techniques are developed to study and measure the shear-wave velocity in an aluminum cylindrical shell subjected to a radial impact. The radial impact is obtained by exploding an electrical detonator inserted in plastic plugs mounted on the end of the shell. Strain gages, mounted on the outside surface of the shell at various axial locations, are used to obtain oscilloscope traces from which the shear-wave velocity can be calculated.

Blum, A.↗

Microwave interferometry technique for obtaining gas interface velocity measurements in an expansion tube facility

A microwave interferometer technique to determine the front interface velocity of a high enthalpy gas flow, is described. The system is designed to excite a standing wave in an expansion tube, and to measure the shift in this standing wave as it is moved by the test gas front. Data, in the form of a varying sinusoidal signal, is recorded on a high-speed drum camera-oscilloscope combination. Measurements of average and incremental velocities in excess of 6,000 meters per second were made.