Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscilloscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Method and apparatus for measuring minority carrier lifetimes and bulk diffusion length in P-N junction solar cells

Carrier lifetimes and bulk diffusion length are qualitatively measured as a means for qualification of a P-N junction photovoltaic solar cell. High frequency (blue) monochromatic light pulses and low-frequency (red) monochromatic light pulses were alternately applied to the cell while it was irradiated by light from a solar simulator, and synchronously displaying the derivative of the output voltage of the cell on an oscilloscope. The output voltage is a measure of the lifetimes of the minority carriers (holes) in the diffused N layer and majority carriers (electrons) in the bulk P material, and of the diffusion length of the bulk silicon. By connecting a reference cell in this manner with a test cell to be tested in reverse parallel, the display of a test cell that matches the reference cell will be a substantially zero output.

Vonroos, O. H.↗

Inflight lightning characteristics measurement system

A research data-gathering system being developed for inflight measurement of direct and nearby lightning strike characteristics is described. Wideband analog recorders used to record the lightning scenario are supplemented with high-sample-rate digital transient recorders with augmented memory capacity for increased time resolution of specific times of interest. The endless-loop data storage technique employed by the transient recorders circumvents problems associated with oscilloscopic techniques and allows unattended operation. System integrity and immunity from induced effects is accomplished by fiber-optics signal-transmission links, shielded system enclosures, and the use of a dynamotor for power system isolation.

Pitts, F. L.↗

Modelling switching-time effects in high-frequency power conditioning networks

Power transistor networks which switch large currents in highly inductive environments are beginning to find application in the hundred kilohertz switching frequency range. Recent developments in the fabrication of metal-oxide-semiconductor field-effect transistors in the power device category have enhanced the movement toward higher switching frequencies. Models for switching devices and of the circuits in which they are imbedded are required to properly characterize the mechanisms responsible for turning on and turning off effects. Easily interpreted results in the form of oscilloscope-like plots assist in understanding the effects of parametric studies using topology oriented computer-aided analysis methods.

Owen, H. A.↗

Calibration tests on magnetic tape lightning current detectors

The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

Crouch, K. E.↗

Magnetic tape lightning current detectors

Development and application tests of a low cost, passive, peak lightning current detector (LCD) found it to provide measurements with accuracies of + or - 5 percent to + or - 10 percent depending on the readout method employed. The LCD uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. The test results showed that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10 percent were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result.

Crouch, K. E.↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

Specifying and calibrating instrumentations for wideband electronic power measurements

The wideband electric power measurement related topics of electronic wattmeter calibration and specification are discussed. Tested calibration techniques are described in detail. Analytical methods used to determine the bandwidth requirements of instrumentation for switching circuit waveforms are presented and illustrated with examples from electric vehicle type applications. Analog multiplier wattmeters, digital wattmeters and calculating digital oscilloscopes are compared. The instrumentation characteristics which are critical to accurate wideband power measurement are described.

Lesco, D. J.↗

Dynamic characteristics of a high-speed rotor with radial and axial foil-bearing supports

An asymmetric rotor (19N; 4.3 lb), supported radially and axially by compliant bearings is subjected to severe excitation by rotating unbalance in the 'pitching' mode at speeds to 50,000 rpm. The resilient, air-lubricated bearings provide very effective damping, so that regions of resonance and instability can be traversed with amplitudes and limit-trajectories within acceptable bounds. A novel journal bearing is introduced, in which a resilient support is furnished by the outer turn of the coiled foil-element bent to form an open polygon. The experimental apparatus and procedure are described, and the response of the rotor and flexible support system are documented by oscilloscope records of motion.

Licht, L.↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Results of an exploration of the relationship between ultrasonic attenuation and fatigue survivability of graphite fiber epoxy composites fabricated under different cure conditions are reported. A total of 9 27 x 40 cm eight-ply graphite epoxy laminated specimens were formed, and fatigue tests were run on five partial samples at 73.5 N varying at 30 Hz, with tests ending at a 1.27 cm deflection. A pulsed oscillator generated sinusoidal waves and transducers recorded the passage of the ultrasonic waves for display on oscilloscopes. Cure pressures ranged from 0.52-0.85 MPa and cure temperatures were in the 150-200 C interval. Ultrasonic through-transmission at 4 MHz was performed prior to and during fatigue testing. The minimum void volume fraction occurred at 175 C and 0.86 MPa. The flexural stiffness decreased with the number of fatigue cycles past 10,000, when the attenuation also increased. Correlations were found between the 4.0 MHz signal attenuation and the void volume fraction, and between the number of fatigue cycles to failure and the 4.0 MHz signal attenuation.

Williams, J. H., Jr.↗

Doppler radar echoes of lightning and precipitation at vertical incidence

Digital time series data at 16 heights within two storms were collected at vertical incidence with a 10-cm Doppler radar. On several occasions during data collection, lightning echoes were observed as increased reflectivity on an oscilloscope display. Simultaneously, lightning signals from nearby electric field change antennas were recorded on an analog recorder together with the radar echoes. Reflectivity, mean velocity, and Doppler spectra were examined by means of time series analysis for times during and after lightning discharges. Spectra from locations where lightning occurred show peaks, due to the motion of the lightning channel at the air speed. These peaks are considerably narrower than the ones due to precipitation. Besides indicating the vertical air velocity that can then be used to estimate hydrometeor-size distribution, the lightning spectra provide a convenient means to estimate the radar cross section of the channel. Subsequent to one discharge, we deduce that a rapid change in the orientation of hydrometeors occurred within the resolution volume.

Zrnic, D. S.↗

Determining the Orientation of Anisotropic Materials

Ultrasonics probe direction of tile fibers. Hand-held acoustic transducer determines fiber orientation of heat resistant tiles. Transducers head placed on outer surface of painted tile. Signals from receiving transducers displayed on two-channel oscilloscope. Application suggests extending technique to inspection of other anisotropic materials. Plywood and fiber/epoxy composites examined to determine fiber direction; ultrasonics used to find direction of roll in sheet metal and other rolled products.

Sugg, F. E.↗

Electronic Force Gage for Welders

Welding force monitored in process. Electronic force gage uses strain gage on deformable member. Oscilloscope trace of welding force photographed and compared with standard trace during calibration and troubleshooting of resistance welding equipment. Adaptable to small scale resistance welding in electronics industry.

Bradley, J. W.↗

Eddy-Current Damage Test for Carbon Composites

Nondestructive test method detects cracks in materials of low conductivity. Test setup includes eddycurrent unit with frequency of 2 to 20 MHz/ and storage oscilloscope. High frequency required to assure depth of penetration less than substrate thickness, to prevent thickness from influencing reading. Eddy-current analysis confirmed by visual inspection as damaged area was sectioned and evaluated.

Hamilton, A. B.↗

Controlling the Focus in Electron-Beam Welders

Detector using two whirling wires measures focus of beam in electronbeam welder. Multiple-wire beam-sampling method provides for simple nullmeter focus indication easily controlled by operator. Detector not only operates at high beam currents but eliminates need for oscilloscope.

Macfarlane, D. I.↗

Development of a simplified optical technique for the simultaneous measurement of particle size distribution and velocity

Existing techniques were surveyed, an experimental procedure was developed, a laboratory test model was fabricated, limited data were recovered for proof of principle, and the relationship between particle size distribution and amplitude measurements was illustrated in an effort to develop a low cost, simplified optical technique for measuring particle size distributions and velocities in fluidized bed combustors and gasifiers. A He-Ne laser illuminated Rochi Rulings (range 10 to 500 lines per inch). Various samples of known particle size distributions were passed through the fringe pattern produced by the rulings. A photomultiplier tube converted light from the fringe volume to an electrical signal which was recorded using an oscilloscope and camera. The signal amplitudes were correlated against the known particle size distributions. The correlation holds true for various samples.

Smith, J. L.↗

Measurement of the J = 0-1 rotational transitions of three isotopes of ArD(+)

The rotational transitions of all three isotopic species of ArD(+) in samples containing the Ar isotopes in their natural abundances have been measured by means of millimeter and submillimeter techniques that employ a magnetically enhanced abnormal glow discharge. All three transition frequency measurements were made from digitally averaged signals detected through a lock-in amplifier with a 10-msec time constant. The Ar-4OD(+) transition was easily visible in real time on an oscilloscope with SNR of about 15. It is noted that the observed transition of Ar-38D(+) is more than five orders of magnitude weaker than that due to HCO(+).

Bowman, W. C.↗

A graphics subsystem retrofit design for the bladed-disk data acquisition system

A graphics subsystem retrofit design for the turbojet blade vibration data acquisition system is presented. The graphics subsystem will operate in two modes permitting the system operator to view blade vibrations on an oscilloscope type of display. The first mode is a real-time mode that displays only gross blade characteristics, such as maximum deflections and standing waves. This mode is used to aid the operator in determining when to collect detailed blade vibration data. The second mode of operation is a post-processing mode that will animate the actual blade vibrations using the detailed data collected on an earlier data collection run. The operator can vary the rate of payback to view differring characteristics of blade vibrations. The heart of the graphics subsystem is a modified version of AMD's ""super sixteen'' computer, called the graphics preprocessor computer (GPC). This computer is based on AMD's 2900 series of bit-slice components.

Carney, R. R.↗

Bulk undercooling

Bulk undercooling methods and procedures will first be reviewed. Measurement of various parameters which are necessary to understand the solidification mechanism during and after recalescence will be discussed. During recalescence of levitated, glass-encased large droplets (5 to 8 mm diam) high speed temperature sensing devices coupled with a rapid response oscilloscope are now being used at MIT to measure local thermal behavior in hypoeutectic and eutectic binary Ni-Sn alloys. Dendrite tip velocities were measured by various investigators using thermal sensors or high speed cinematography. The confirmation of the validity of solidification models of bulk-undercooled melts is made difficult by the fineness of the final microstructure, the ultra-rapid evolution of the solidifying system which makes measurements very awkward, and the continuous modification of the microstructure which formed during recalescence because of precipitation, remelting and rapid coarsening.

Kattamis, T. Z.↗