Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Power Saving Optimization for Linear Collider Interaction Region Parameters

Optimization of Interaction Region parameters of a TeV energy scale linear collider has to take into account constraints defined by phenomena such as beam-beam focusing forces, beamstrahlung radiation, and hour-glass effect. With those constraints, achieving a desired luminosity of about 2E34 would require use of e{sup +}e{sup -} beams with about 10 MW average power. Application of the 'travelling focus' regime may allow the required beam power to be reduced by at least a factor of two, helping reduce the cost of the collider, while keeping the beamstrahlung energy loss reasonably low. The technique is illustrated for the 500 GeV CM parameters of the International Linear Collider. This technique may also in principle allow recycling the e{sup +}e{sup -} beams and/or recuperation of their energy.

43 PARTICLE ACCELERATORS↗

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Analytic Framework for Optimal Milling Parameter Selection

The selection of optimal parameters is an important step in machining process definition. This paper presents a decision analytic framework for completing this task. The approach is demonstrated for titanium milling. An influence diagram showing the decision situation, the corresponding uncertainties, and the value is presented. The optimization objective is the selection of machining parameters that minimize cost while considering uncertainty in tool life and stability. The uncertainties are characterized using a probability distribution taking into account all available information. The cost associated with tool failure and unstable cutting conditions is incorporated in the cost formulation. A process probability tree showing the uncertainties and the corresponding costs is constructed. The optimization results show a 90% reduction in machining cost as compared to tool manufacturer-recommended parameters. The proposed framework is normative and robust and can be applied for optimizing process parameters in conventional (such as milling and turning) and non-conventional (such as electric discharge machining, electro-chemical machining) processes. A discussion section regarding inference, experimental design, and risk aversion is included.

Karandikar, Jaydeep↗

Uncertainty quantification and optimization of precipitating hydrometeor parameters for winter precipitation in a cloud microphysics scheme

The precipitating hydrometeor parameters used in cloud microphysics schemes carry inherent uncertainties. The quantification of these uncertainties, together with parameter optimization, can significantly improve precipitation forecasts. This study investigates the effects of 13 parameters in the Weather Research and Forecasting (WRF) Double-Moment 6-class (WDM6) microphysics scheme, which define the hydrometeor characteristics such as fall velocity–diameter and mass–diameter relationships, as well as the shape parameter of the drop size distribution for precipitating particles such as rain, snow, and graupel on simulated winter precipitation. A comparison between the model's pre-defined parameters and observations from the International Collaborative Experiments for the PyeongChang 2018 Olympic and Paralympic winter games (ICE-POP 2018) field campaign reveals that the fall velocity–diameter relationship for rain, the mass–diameter relationships for snow and graupel, and the shape parameters for all precipitating particles in the WDM6 scheme deviate from the median values observed by the two-dimensional video disdrometer (2DVD). To quantify parameter sensitivities, a perturbed parameter ensemble (PPE) of 256 simulations was conducted within parameter ranges constrained by 2DVD observations for three winter precipitation cases. Bayesian optimization was then applied to identify parameter sets that minimized the root mean square error (RMSE) for each case, achieving reductions of up to 30.2 %. These results demonstrate that ensemble-based uncertainty quantification and parameter optimization can help identify key parameters and provide a pathway to improving precipitation simulation performance. In addition, measurement sites can be strategically selected based on regions that show high sensitivity to variations in hydrometeor characteristic parameters.

Bayesian optimization↗

Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

Purpose: Aims in this study are to (1) develop a computational model observer which reliably tracks the detectability of human observers in low dose computed tomography (CT) images reconstructed with knowledge-based iterative reconstruction (IMR™, Philips Healthcare) and filtered back projection (FBP) across a range of independent variables, (2) use the model to evaluate detectability trends across reconstructions and make predictions of human observer detectability, and (3) perform human observer studies based on model predictions to demonstrate applications of the model in CT imaging. Methods: Detectability (d′) was evaluated in phantom studies across a range of conditions. Images were generated using a numerical CT simulator. Trained observers performed 4-alternative forced choice (4-AFC) experiments across dose (1.3, 2.7, 4.0 mGy), pin size (4, 6, 8 mm), contrast (0.3%, 0.5%, 1.0%), and reconstruction (FBP, IMR), at fixed display window. A five-channel Laguerre–Gauss channelized Hotelling observer (CHO) was developed with internal noise added to the decision variable and/or to channel outputs, creating six different internal noise models. Semianalytic internal noise computation was tested against Monte Carlo and used to accelerate internal noise parameter optimization. Model parameters were estimated from all experiments at once using maximum likelihood on the probability correct, P{sub C}. Akaike information criterion (AIC) was used to compare models of different orders. The best model was selected according to AIC and used to predict detectability in blended FBP-IMR images, analyze trends in IMR detectability improvements, and predict dose savings with IMR. Predicted dose savings were compared against 4-AFC study results using physical CT phantom images. Results: Detection in IMR was greater than FBP in all tested conditions. The CHO with internal noise proportional to channel output standard deviations, Model-k4, showed the best trade-off between fit and model complexity according to AIC{sub c}. With parameters fixed, the model reasonably predicted detectability of human observers in blended FBP-IMR images. Semianalytic internal noise computation gave results equivalent to Monte Carlo, greatly speeding parameter estimation. Using Model-k4, the authors found an average detectability improvement of 2.7 ± 0.4 times that of FBP. IMR showed greater improvements in detectability with larger signals and relatively consistent improvements across signal contrast and x-ray dose. In the phantom tested, Model-k4 predicted an 82% dose reduction compared to FBP, verified with physical CT scans at 80% reduced dose. Conclusions: IMR improves detectability over FBP and may enable significant dose reductions. A channelized Hotelling observer with internal noise proportional to channel output standard deviation agreed well with human observers across a wide range of variables, even across reconstructions with drastically different image characteristics. Utility of the model observer was demonstrated by predicting the effect of image processing (blending), analyzing detectability improvements with IMR across dose, size, and contrast, and in guiding real CT scan dose reduction experiments. Such a model observer can be applied in optimizing parameters in advanced iterative reconstruction algorithms as well as guiding dose reduction protocols in physical CT experiments.

60 APPLIED LIFE SCIENCES↗

SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Three different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stability boundary and optimal operating parameter identification in milling using Bayesian learning

Here, this paper describes a novel Bayesian learning approach for stability boundary and optimal parameter identification in milling without the knowledge of the underlying tool dynamics or material cutting force coefficients. The paper is divided into two parts. First, a Bayesian learning method for stability lobe identification using test results is described. Each axial depth and spindle speed combination is characterized by a probability of stability which is updated using Bayes’ rule when a test result (stable or unstable) is made available. A novel likelihood function is defined which incorporates knowledge of the stability behavior. Numerical results show convergence to the analytical stability lobe diagram. Second, an adaptive experimental strategy to identify optimal operating parameters that maximize material removal rate is described. Numerical evaluation shows convergence to the optimal operating point with error less than 15 % within ten tests on average. The approach is validated using experimental results. Results show that the proposed method is an efficient and robust learning method to identify the stability lobe diagram and optimal operating parameters with a limited number of tests/data points.

Bayesian machine learning↗

End-to-end protocol for high-quality quantum approximate optimization algorithm parameters with few shots

The quantum approximate optimization algorithm (QAOA) is a quantum heuristic for combinatorial optimization that has been demonstrated to scale better than state-of-the-art classical solvers for some problems. For a given problem instance, QAOA performance depends crucially on the choice of the parameters. While average-case optimal parameters are available in many cases, meaningful performance gains can be obtained by fine-tuning these parameters for a given instance. This task is especially challenging, however, when the number of circuit executions (shots) is limited. In this work, we develop an end-to-end protocol that combines multiple parameter settings and fine-tuning techniques. We use large-scale numerical experiments to optimize the protocol for the shot-limited setting and observe that optimizers with the simplest internal model (linear) perform best. We implement the optimized pipeline on a trapped-ion processor using up to 32 qubits and 5 QAOA layers, and we demonstrate that the pipeline is robust to small amounts of hardware noise. To the best of our knowledge, these are the largest demonstrations of QAOA parameter fine-tuning on a trapped-ion processor in terms of two-qubit gate count.

quantum algorithms & computation↗

A multicriteria framework with voxel-dependent parameters for radiotherapy treatment plan optimization

Purpose: To establish a new mathematical framework for radiotherapy treatment optimization with voxel-dependent optimization parameters. Methods: In the treatment plan optimization problem for radiotherapy, a clinically acceptable plan is usually generated by an optimization process with weighting factors or reference doses adjusted for a set of the objective functions associated to the organs. Recent discoveries indicate that adjusting parameters associated with each voxel may lead to better plan quality. However, it is still unclear regarding the mathematical reasons behind it. Furthermore, questions about the objective function selection and parameter adjustment to assure Pareto optimality as well as the relationship between the optimal solutions obtained from the organ-based and voxel-based models remain unanswered. To answer these questions, the authors establish in this work a new mathematical framework equipped with two theorems. Results: The new framework clarifies the different consequences of adjusting organ-dependent and voxel-dependent parameters for the treatment plan optimization of radiation therapy, as well as the impact of using different objective functions on plan qualities and Pareto surfaces. The main discoveries are threefold: (1) While in the organ-based model the selection of the objective function has an impact on the quality of the optimized plans, this is no longer an issue for the voxel-based model since the Pareto surface is independent of the objective function selection and the entire Pareto surface could be generated as long as the objective function satisfies certain mathematical conditions; (2) All Pareto solutions generated by the organ-based model with different objective functions are parts of a unique Pareto surface generated by the voxel-based model with any appropriate objective function; (3) A much larger Pareto surface is explored by adjusting voxel-dependent parameters than by adjusting organ-dependent parameters, possibly allowing for the generation of plans with better trade-offs among different clinical objectives. Conclusions: The authors have developed a mathematical framework for radiotherapy treatment optimization using voxel-based parameters. The authors can improve the plan quality by adjusting voxel-based weighting factors and exploring the unique and large Pareto surface which include all the Pareto surfaces that can be generated by organ-based model using different objective functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine Learning-Based Technique for Automated Sensor Characterization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert s time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Zepeda, Cuevas [Chicago U., KICP]↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗

Application of a machine learning algorithm (XGBoost) to offline RHIC luminosity optimization

The operation parameter optimization in 2020 RHIC low energy run is difficult. First, the RHIC luminosity is affected by many RHIC operation parameters, as well as affected by many Low Energy RHIC electron Cooling (LEReC) operation parameters. Second, the luminosity signal in this run is noisy and not sensitive to these parameter changes, especially when these parameters are very close to their optimized values. It is not easy to distinguish the effects of one parameter from all other operation parameters separately. Therefore, it is difficult to optimize the luminosity by varying these parameters one by one. To find a way for luminosity optimization, we analyze some operation parameters via a machine learning algorithm - XGBoost. After constructing a black-box surrogate model from XGBoost and plotting their partial dependency plots (PDF) and SHAP value plots for different operation parameters, we can find the effects of an individual parameter on the RHIC luminosity and optimize it accordingly.

43 PARTICLE ACCELERATORS↗

Distributionally Robust Variational Quantum Algorithms With Shifted Noise

Given their potential to demonstrate near-term quantum advantage, variational quantum algorithms (VQAs) have been extensively studied. Although numerous techniques have been developed for VQA parameter optimization, it remains a significant challenge. A practical issue is the high sensitivity of quantum noise to environmental changes, and its propensity to shift in real time. This presents a critical problem as an optimized VQA ansatz may not perform effectively under a different noise environment. For the first time, we explore how to optimize VQA parameters to be robust against unknown shifted noise. We model the noise level as a random variable with an unknown probability density function (PDF), and we assume that the PDF may shift within an uncertainty set. This assumption guides us to formulate a distributionally robust optimization problem, with the goal of finding parameters that maintain effectiveness under shifted noise. We utilize a distributionally robust Bayesian optimization solver for our proposed formulation. This provides numerical evidence in both the Quantum Approximate Optimization Algorithm (QAOA) and the Variational Quantum Eigensolver (VQE) with hardware-efficient ansatz, indicating that we can identify parameters that perform more robustly under shifted noise. We regard this work as the first step towards improving the reliability of VQAs influenced by real-time noise.

97 MATHEMATICS AND COMPUTING↗

Application of a spring-dashpot system to clinical lung tumor motion data

Purpose: The treatment efficacy of radiation therapy for lung tumors can be increased by compensating for breath-induced tumor motion. In this study, we quantitatively examine a mathematical model of pseudomechanical linkages between an external surrogate signal and lung tumor motion. Methods: A spring-dashpot system based on the Voigt model was developed to model the correlation between abdominal respiratory motion and tumor motion during lung radiotherapy. The model was applied to clinical data obtained from 52 treatments ('beams') from 10 patients, treated on the Mitsubishi Real-Time Radiation Therapy system, Sapporo, Japan. In Stage 1, model parameters were optimized for individual patients and beams to determine reference values and to investigate how well the model can describe the data. In Stage 2, for each patient the optimal parameters determined for a single beam were applied to data from other beams to investigate whether a beam-specific set of model parameters is sufficient to model tumor motion over a course of treatment. Results: In Stage 1, the baseline root mean square (RMS) residual error for all individually optimized beam data was 0.90 {+-} 0.40 mm (mean {+-} 1 standard deviation). In Stage 2, patient-specific model parameters based on a single beam were found to model the tumor position closely, even for irregular beam data, with a mean increase with respect to Stage 1 values in RMS error of 0.37 mm. On average, the obtained model output for the tumor position was 95% of the time within an absolute bound of 2.0 and 2.6 mm in Stages 1 and 2, respectively. The model was capable of dealing with baseline, amplitude and frequency variations of the input data, as well as phase shifts between the input abdominal and output tumor signals. Conclusions: These results indicate that it may be feasible to collect patient-specific model parameters during or prior to the first treatment, and then retain these for the rest of the treatment period. The model has potential for clinical application during radiotherapy treatment of lung tumors.

60 APPLIED LIFE SCIENCES↗

Lithium-ion battery physics and statistics-based state of health model

A pseudo-2d model using COMSOL Multiphysics® software is developed to simulate performance and performance degradation of Li-ion batteries consisting of layered and olivine cathodes with graphite anode when subjected to peak shaving grid service. Multiple degradation pathways are considered, including solid electrolyte interphase (SEI) formation and breakdown at the anode, cathode dissolution and its synergistic effect on SEI formation at the anode. The model is validated by simulating commercial cylindrical cell performance. A global model is developed to simulate performance across all chemistries, along with individual chemistry models using global model parameters as initial values. There is good agreement between these models for various optimization parameters such as SEI equilibrium potential, cathode dissolution exchange current density, solvent diffusivity in the SEI and SEI ionic conductivity. To circumvent time constraints related to the COMSOL model, a 0d global model is developed which fits data well and provides more clarity on differences in cathode dissolution exchange current density. Again, good agreement for various optimization parameters is obtained among the COMSOL global & individual chemistry models and the 0-d model. The lessons learned from the physics-based model is used to develop a top down statistics-based model using current, voltage and anode volumetric change per mole lithium intercalated, along with their interactions as degradation predictors. This model predicts out of sample degradation for multiple grid services and electric vehicle drive cycle with high accuracy and provides the pathway to develop an efficient battery management system combining machine learning and findings from physics-based computationally intensive algorithms.

Crawford, Aladsair J.↗

Characterization of Hot Workability of 5052 Aluminum Alloy Based on Activation Energy-Processing Map

In the design of hot forming processes for aluminum alloys, hot processing maps are usually used as a powerful tool for processing parameters optimizations. Although the stability of deformation is considered in conventional hot processing (CHP) maps, the difficulty of deformation, i.e., whether deformation is easy to occur, is not taken into account. Therefore, it is difficult for CHP maps to efficiently and accurately obtain the optimal processing parameters and achieve satisfying hot workability. Hence, in this study, thermal compression tests were performed to investigate the hot forming behavior of 5052 aluminum alloy in the deformation temperature range of 553-733 K and strain rate range of 0.001-1 s{sup −1}. We proposed an activation energy-processing (AEP) map by coupling the CHP map and the activation energy value, and thereby applied it to evaluate the hot workability of 5052 aluminum alloy. In CHP maps, the region with the highest power dissipation efficiency is generally considered to be the best processing region. However, the AEP map shows that materials with satisfying hot workability not only depends on high power dissipation efficiency, but also on low activation energy values. At the strain of 0.7, the optimal hot processing region predicted by the CHP map lies in the temperature range of 583-673 K and strain rate range of 0.001-0.1 s{sup −1}, but that predicted by AEP map locates in the temperature range of 643-733 K and strain rate range of 0.001-0.1 s{sup −1}. Microstructure characterization implies that the optimal processing region predicted by the CHP map presents necklace-like structures, which are non-uniform and unbeneficial for deformation, while that predicted by the AEP map consists of fine, uniform and equiaxed grains. Thus, it is implied that the processing regions predicted by the AEP map are more suitable for forming, i.e., the reasonability of the AEP map is verified.

36 MATERIALS SCIENCE↗

Investigating the practicality of a minimally defined co-axial HPGe detector model using MCNP

An MCNP model of a co-axial HPGe detector, defined by the specification sheet and without parameter optimization, was used to assess practicality for efficiency characterization and complex spectra simulation. Simulated efficiencies, with and without Gaussian energy broadening, were compared against an experimental calibration for a standard counting geometry. Results show that this minimal detector model predicted efficiencies within 6% of experimental values at energies above 100 keV, while including energy broadening offered little improvement. Furthermore, this work shows that extensive detector characterization and optimization of parameters is not absolutely necessary, thereby reducing the experimental burden associated with detector modeling for many applications.

42 ENGINEERING↗