Design and Conduct of a Windshear Detection Flight Experiment

A description of the design and conduct of a series of flight experiments which tested the performance of candidate windshear detection devices is presented. With prototype windshear sensors installed, a NASA Boeing 737 test aircraft conducted numerous low altitude penetrations of microburst windshear conditions. These tests were preceded by extensive preparations which included piloted simulations, determination of safe operating limits, and the development of unique flight test hardware, displays, and procedures. The test aircraft and more than 50 research and support personnel were deployed to Orlando, Florida, and Denver, Colorado, during June and July 1991 for field testing. Upon receiving a forecast of developing weather activity, the aircraft crew launched and proceeded to the storm location, guided by uplinked ground radar information and voice communications with ground weather personnel. The tests required constant monitoring of numerous factors including aircraft flight parameters, ground obstructions, windshear magnitude, lightning, escape routes, ATC coordination, storm cell development, and others. The flight tests were extremely successful, safely recording more than 25 low altitude microburst windshear and strong gust front approaches and penetrations, along with completing a full test matrix of additional requirements related to windshear sensor performance. Data quality from the tests was excellent and indicates strong potential for airborne remote sensors to accurately predict and warn the flight crew of hazardous windshear conditions with ample time for precautionary crew action.

Flight Testing↗

Detection of fatigue cracks by nondestructive testing methods

The effectiveness was assessed of various NDT methods to detect small tight cracks by randomly introducing fatigue cracks into aluminum sheets. The study included optimizing NDT methods calibrating NDT equipment with fatigue cracked standards, and evaluating a number of cracked specimens by the optimized NDT methods. The evaluations were conducted by highly trained personnel, provided with detailed procedures, in order to minimize the effects of human variability. These personnel performed the NDT on the test specimens without knowledge of the flaw locations and reported on the flaws detected. The performance of these tests was measured by comparing the flaws detected against the flaws present. The principal NDT methods utilized were radiographic, ultrasonic, penetrant, and eddy current. Holographic interferometry, acoustic emission monitoring, and replication methods were also applied on a reduced number of specimens. Generally, the best performance was shown by eddy current, ultrasonic, penetrant and holographic tests. Etching provided no measurable improvement, while proof loading improved flaw detectability. Data are shown that quantify the performances of the NDT methods applied.

Anderson, R. T.↗

Flight-test experience of a helicopter encountering an airplane trailing vortex

This paper presents results of a flight-test experiment of a UH-1H helicopter encountering the vortex wake of a C-54 airplane. The helicopter was instrumented to record the pilot control inputs, determine the upset experience, and measure critical loads within the rotor system. During the flight-test program 132 penetrations of the vortex wake were made by the helicopter at separation distances from 3/8 to 6-1/2 nautical miles. Test results indicated that the helicopter upsets and the vortex induced blade loads experienced were minimal and well within safe limits. The upsets were very mild when compared to a typical response of a small airplane to the vortex wake of the C-54 airplane.

Dunham, R. E., Jr.↗

Lithium-Ion Batteries with Safer Current Collectors

The US Department of Energy’s Oak Ridge National Laboratory and Soteria Battery Innovation Group collaborated to develop a metallized polymer film as a current collector for lithium-ion batteries and design slit patterns for electrodes to improve battery safety. The metallized polymer film serves as a fuse that will break under high temperature resulting from a short circuit. Consequently, the short circuit will be broken and the heat generated from the short circuit will be alleviated to avoid thermal runaway. The electrodes with slit patterns are expected to be broken into small segments upon mechanical impact, which can isolate the damaged electrodes from the rest. Thus, the heat generation associated with the mechanical impact will be reduced, along with the likelihood of thermal runaway. This effort aimed to improve lithium-ion battery safety by replacing traditional metal foils with metallized polymer films as current collector and introducing slit patterns to battery electrodes. The metallized polymer films were polyethylene terephthalate with a thin metal (aluminum for cathodes and copper for anodes) coating on both sides. Slit patterns with various geometries and dimensions were designed via simulation. Temperature distribution on cells with electrodes with and without slit patterns was also simulated via nemerical modeling. Electrodes on traditional metal foils and metallized polymer films were coated via a pilot-scale slot-die coater at the US Department of Energy Battery Manufacturing Facility at Oak Ridge National Laboratory. The electrodes were calendered to 35% porosity and punched out with and without slit patterns. Pouch cells were assembed with the electrodes inside a dry room for electrochemical and safety testing. Electrodes coated on metallized polymer films exhibited comparable electrochemical performance to their counterparts coated on traditional metal foils. They also showed improved safety in nail penetration and indentation tests.

25 ENERGY STORAGE↗

External tank space debris considerations

Orbital debris issues associated with maintaining a Space Shuttle External Tank (ET) on orbit are presented. The first issue is to ensure that the ET does not become a danger to other spacecraft by generating space debris, and the second is to protect the pressurized ET from penetration by space debris or meteoroids. Tests on shield designs for penetration resistance showed that when utilized with an adequate bumper, thermal protection system foam on the ET is effective in preventing penetration.

Elfer, N.↗

Mapping Ice Buried by the 1875 and 1961 Tephra of Askja Volcano, Northern Iceland using Ground-Penetrating Radar: Implications for Askja Caldera as a Geophysical Testbed for In-Situ Resource Utilization

Eruptions of the Askja Volcano in Northern Iceland in 1875 and 1961 blanketed the caldera with rhyolitic and basaltic tephra deposits, respectively, which preserved layers of seasonal snowpack as massive ice. Askja serves as an operational and geophysical analog to test ground-penetrating radar field and analysis techniques for in-situ resource utilization objectives relevant to the martian and lunar environments. We conducted ground-penetrating radar surveys at center frequencies of 200, 400, and 900 MHz to map the thickness and extent of tephra deposits and underlying massive ice at three caldera sites. We identified up to 1 meter of tephra preserving up to 4.5 meters of massive ice. We measured the real dielectric permittivity of the overlying tephra and the total attenuation at each frequency of the tephra and ice. A key objective of our investigation was to determine if this attenuation (or loss) could be used as an additional, identifying characteristic of massive ice preserved at depth when compared to ice-free stratigraphy. Loss rates of the ice-rich subsurface decreases with increasing ice thickness relative to the overburden which may constitute a possible signature. Attenuation also increased with increasing frequency. The tephra, ice, and other volcanic deposits at each of our three caldera sites and the ice-free pumice-mantled 1961 Vikrahraun lava flow exhibited a characteristically low loss rate at all frequencies. This result highlights the ambiguity associated with identifying the unique signature of ice within low-loss stratigraphies, a possible challenge for its identification in the martian or lunar subsurface using radar.

Emileigh S. Shoemaker↗

Selective penetration behavior of microgels in superpermeable channels and reservoir matrices

Gel treatment is an effective way to attack excessive water production in many mature oilfields around the world. Selective penetration is desired for successful gel treatments. That is, gel materials should easily penetrate the target zones (i.e., channeling features such as superpermeable channels) without entering/damaging the nontarget zones (i.e., reservoir matrices or oil zones). This study revealed that presence of threshold penetration pressure (ΔP th ) was responsible for selective penetration behavior of tested microgels. The concept of ΔP th was utilized to figure out favorable working conditions for effective gel treatments. Microgel dispersions were injected into superpermeable (super-k) sandpacks (mimicking super-k channels in reservoirs, 60–221 darcies), heterogeneous models with super-k channels (79–230 darcies), and sandstone cores (mimicking reservoir matrices, 50–5000 md). The results demonstrated that a minimum differential driving pressure (i.e., threshold penetration pressure, ΔP th ) was required to push microgel particles to penetrate channels or matrices. The critical penetration behavior was closely related to the particle/pore size ratio. Low ΔP th at smaller particle/pore ratios was beneficial to allow easy penetration of gel materials into the channeling zones. On the contrary, high ΔPth at larger particle/pore ratios was desirable to prevent gel materials from massively invading and damaging the matrices. Instead, the gel particles accumulated at the inlet surface, and a gel cake was gradually formed. The cake further prevented the invasion of the gels. The cake could be removed by chemical breakers to resume the injectivity/productivity of the matrices. Correlations were developed to describe the relationship between ΔP th and particle/pore ratio. A distinct transition was identified at the particle/pore ratio of about 3. This research could help identify the favorable conditions to achieve successful gel treatments. In an effective conformance treatment, the particle/pore ratio in the channel should be sufficiently low to allow easy penetration of gel materials into the channel (e.g., particle/pore ratio<2 in this study). Meanwhile, the particle/pore ratio in the matrix should be large enough to support a high ΔP th and thus prevent massive gel invasion into the matrix. This study advances the current pore scale studies (a single particle passing through a single channel) to Darcy-scale characterization.

02 PETROLEUM↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The detection of fatigue cracks by nondestructive test methods

X-radiographic, penetrant, ultrasonic, and eddy current techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 1.27 to 0.018 cm and in depth from 0.451 to 0.003 cm. Specimen thicknesses were nominally 0.152 and 0.532 cm. Specimens were evaluated in the 'as-milled' surface condition, in the etched surface condition, and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test evaluations were compared with actual crack size obtained by analysis of the fractured specimens. Inspection data were then analyzed to provide a statistical basis for determining the threshold crack detection sensitivity for each of the inspection techniques at a 95% probability and 95% confidence level.

Rummel, W. D.↗

The detection of fatigue cracks by nondestructive testing methods

X-radiographic penetrant, ultrasonic, eddy current, holographic, and acoustic emission techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 0.500 inch (1.27 cm) to 0.007 inch (0.018 cm) and in depth from 0.178 inch (0.451 cm) and 0.001 inch (0.003 cm). Specimen thicknesses were nominally 0.060 inch (0.152 cm) and 0.210 inch (0.532 cm) and surface finishes were nominally 32 and 125 rms and 64 and 200 rms respectively. Specimens were evaluated in the as-milled surface condition, in the chemically milled surface condition and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test (NDT) evaluations were compared with actual crack size obtained by measurement of the fractured specimens. Inspection data was then analyzed to provide a statistical basis for determinating the threshold crack detection sensitivity (the largest crack size that would be missed) for each of the inspection techniques at a 95% probability and 95% confidence level.

Rummel, W. D.↗

A Model for Shear Layer Effects on Engine Noise Radiation

Prediction of aircraft engine noise is an important aspect of addressing the issues of community noise and cabin noise control. The development of physics based methodologies for performing such predictions has been a focus of Computational Aeroacoustics (CAA). A recent example of code development in this area is the ducted fan noise propagation and radiation code CDUCT-LaRC. Included within the code is a duct radiation model that is based on the solution of FfowcsWilliams-Hawkings (FW-H) equation with a penetrable data surface. Testing of this equation for many acoustic problems has shown it to provide generally better results than the Kirchhoff formula for moving surfaces. Currently, the data surface is taken to be the inlet or exhaust plane for inlet or aft-fan cases, respectively. While this provides reasonable results in many situations, these choices of data surface location lead to a few limitations. For example, the shear layer between the bypass ow and external stream can refract the sound waves radiated to the far field. Radiation results can be improved by including this effect, as well as the rejection of the sound in the bypass region from the solid surface external to the bypass duct surrounding the core ow. This work describes the implementation, and possible approximation, of a shear layer boundary condition within CDUCT-LaRC. An example application also illustrates the improvements that this extension offers for predicting noise radiation from complex inlet and bypass duct geometries, thereby providing a means to evaluate external treatments in the vicinity of the bypass duct exhaust plane.

Nark, Douglas M.↗

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

Improved spatial uniformity of beam-plane interaction by means of inverse rastering

An analysis is presented that shows the desirability and feasibility of conducting irradiations of large test objects by beams of penetrating radiation, by the method of moving the test object back and forth through the beam, rather than by sweeping the beam across the object. An extension of this method of inverse rastering allows the generation of composite beams with any desired intensity-vs-energy spectrum, obviating the need to determine equivalent damage factors for every energy in the spectrum.

Miller, C. G.↗

Bridging the length scales on mechanical property evaluation (Final Report)

The development of small-scale mechanical testing in combination with microstructural investigation is of great interest to the nuclear materials community for both materials development and monitoring applications. Dramatically reducing the sample sizes to reduce radioactivity and obtaining mechanical properties of irradiated samples is truly intriguing. Moreover, such studies promise a range of benefits including cost reduction, fundamental insight in structure-property relationships, increased statistics on less sample material, and reinvestigation of prior irradiated and tested reactor samples while simultaneously enabling the generation of mechanical test data on ion beam irradiated materials with limited penetration depths. Small scale materials testing on sub-sized samples has been studied for several decades, though it has only been after the development of micro-testing based on Focused Ion Beam (FIB) sample manufacturing in that orders of magnitude smaller samples could really be investigated in a quantitative manner. In recent years, small scale mechanical testing techniques at a number of length scales has been developed for both unirradiated and irradiated (ion and neutron) materials. Technological advances made in this field have enabled ex-situ and in-situ transmission electron microscopy (TEM) and scanning electron microscopy (SEM) examination, thus leading to more accurate measurements as well as additional mechanistic information. A recent review of the benefits of these techniques show that these techniques are at a stage to tackle multi-scale ranges of materials investigations and can be utilized to obtain fundamental science-based understanding of nuclear materials. Considering the tremendous advances made, one can see how small-scale mechanical testing techniques combined with modeling can enable true small scale to bulk scale mechanical property correlations. However, for the engineering community to adapt this approach fully, one needs to demonstrate that a) that these techniques can produce results with high fidelity and reproducibility, b) generate engineering stress-strain data that one can utilize to understand bulk behavior, and c) generate new insight into relevant phenomena fostering the true understanding of radiation damage and microstructure in materials for nuclear applications. It is the objective of this proposal to bridge the length scale between macro- and micro- scale mechanical testing of unirradiated and irradiated materials. This involves the development and demonstration of procedures for multi-scale mechanical testing that enable high fidelity reproducibility of data and the generation bulk property data from small-scale mechanical tests. Through this, the proposal aims to enhance the confidence in the obtained data at the smaller length scales and enhance the insight provided from these techniques for bulk scale applications on both unirradiated and irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Drag and distribution measurements of single-element fuel injectors for supersonic combustors

The drag caused by several vortex generating fuel injectors for scramjet combustors was measured in a Mach 2 to 3.5 airstream. Injector drag was found to be strongly dependent on injector thickness ratio. The distribution of helium injected into the stream was measured both in the near field and the far field of the injectors for a variety of pressure ratios. The far field results differed appreciably from measurements in the near field. Injection pressure ratio was found to profoundly influence the penetration. One of the aerowing configurations tested yielded low drag consistent with desirable penetration and spreading characteristics.

Povinelli, L. A.↗

Simulated meteoroid penetration of reusable surface insulation

Meteoroid impact simulation test results on insulation tiles were used to determine penetration resistance of reusable surface insulation attached to simulated shuttle structures. The probability of no meteoroid damage to a typical shuttle orbiter was determined. Specimens were plasma jet tested to determine effects of various size meteoroid cavities on their thermal performance. None of the tiles failed catastrophically, but large, egg-shaped craters did result from meteoroid penetration. The metallic side of a specimen that was completely penetrated showed a petalled hole typical for thin gage shielded structures.

Lehman, J. K.↗