Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A digitally implemented phase-locked loop detection scheme for analysis of the phase and power stability of a calibration tone

A digital phase-locked loop (PLL) scheme is described which detects the phase and power of a high SNR calibration tone. The digital PLL is implemented in software directly from the given description. It was used to evaluate the stability of the Goldstone Deep Space Station open loop receivers for Radio Science. Included is a derivative of the Allan variance sensitivity of the PLL imposed by additive white Gaussian noise; a lower limit is placed on the carrier frequency.

Densmore, A. C.↗

Uplink Array Calibration via Far-Field Power Maximization

Uplink antenna arrays have the potential to greatly increase the Deep Space Network s high-data-rate uplink capabilities as well as useful range, and to provide additional uplink signal power during critical spacecraft emergencies. While techniques for calibrating an array of receive antennas have been addressed previously, proven concepts for uplink array calibration have yet to be demonstrated. This article describes a method of utilizing the Moon as a natural far-field reflector for calibrating a phased array of uplink antennas. Using this calibration technique, the radio frequency carriers transmitted by each antenna of the array are optimally phased to ensure that the uplink power received by the spacecraft is maximized.

Vilnrotter, V.↗

Calibration of the Ames Anechoic Facility. Phase 1: Short range plan

A calibration was made of the acoustic and aerodynamic characteristics of a small, open-jet wind tunnel in an anechoic room. The jet nozzle was 102 mm diameter and was operated subsonically. The anechoic-room dimensions were 7.6 m by 5.5 m by 3.4 m high (wedge tip to wedge tip). Noise contours in the chamber were determined by various jet speeds and exhaust collector positions. The optimum nozzle/collector separation from an acoustic standpoint was 2.1 m. Jet velocity profiles and turbulence levels were measured using pressure probes and hot wires. The jet was found to be symmetric, with no unusual characteristics. The turbulence measurements were hampered by oil mist contamination of the airflow.

Hickey, D.↗

Calibration of the 2-Phase Bubble Tracking Model for Liquid Mercury Target Simulation with Machine Learning Surrogate Models

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is one of the most powerful accelerator-driven neutron sources in the world. The intense protons strike on SNS's mercury target to provide bright neutron beams, which also leads to severe fluid-structure interactions inside the target. Prediction of resultant loading on the target is difficult particularly when helium gas is injected into mercury to reduce the loading and mitigate the pitting damage on vessel walls. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this multi-physics problem. However, several uncertain parameters in the R-P model require intensive simulations to determine their optimal values. With the help of machine learning and the measured target strain, we have studied the major uncertain parameters in this R-P model and developed a framework to identify optimal parameters that significantly reduce the discrepancy between simulations and experimental strains. The preliminary results show the possibility of using this mercury/helium mixture and surrogate models to predict a better match of target strain response when the helium gas is injected.

Lin, Lianshan↗

Jason-1 Precise Orbit Determination from GPS Tracking: Method, Performance and Calibration of the Lc Phase Center Offset

Jason-1, launched on December 7, 2001, is continuing the time series of centimeter level Ocean topography observations as the follow-on to the highly successful TOPEX/POSEIDON (T/P) radar altimeter satellite. The precision orbit determination (POD) is a critical component to meeting the Ocean topography goals of the mission. T/P has demonstrated that the time variation of Ocean topography can be determined with an accuracy of a few centimeters, thanks to the availability of highly accurate orbits based primarily on SLR+DORIS tracking. The Jason-1 mission is intended to continue measurement of the Ocean surface with the same, if not better accuracy.

Luthcke, Scott B.↗

Digital Phase-Shift Standard

Digital phase-shift standard used in combination with oscillator to calibrate other phase standards and phase-angle voltmeters. Phase-shifter circuit provides two square-wave outputs, A and B, with phase difference between them selectable in 30 degrees increments. Circuit is used with input signals as low as 1 volt rms, in almost any waveform.

Cramp, J. A.↗

Extraction of quantitative surface characteristics from AIRSAR data for Death Valley, California

Polarimetric Airborne Synthetic Aperture Radar (AIRSAR) data were collected for the Geologic Remote Sensing Field Experiment (GRSFE) over Death Valley, California, USA, in Sep. 1989. AIRSAR is a four-look, quad-polarization, three frequency instrument. It collects measurements at C-band (5.66 cm), L-band (23.98 cm), and P-band (68.13 cm), and has a GIFOV of 10 meters and a swath width of 12 kilometers. Because the radar measures at three wavelengths, different scales of surface roughness are measured. Also, dielectric constants can be calculated from the data. The AIRSAR data were calibrated using in-scene trihedral corner reflectors to remove cross-talk; and to calibrate the phase, amplitude, and co-channel gain imbalance. The calibration allows for the extraction of accurate values of rms surface roughness, dielectric constants, sigma(sub 0) backscatter, and polarization information. The radar data sets allow quantitative characterization of small scale surface structure of geologic units, providing information about the physical and chemical processes that control the surface morphology. Combining the quantitative information extracted from the radar data with other remotely sensed data sets allows discrimination, identification and mapping of geologic units that may be difficult to discern using conventional techniques.

Kierein-Young, K. S.↗

Ultrasonic calibration device

Device is an instrument for producing known changes in both acoustic absorption and phase velocity. Calibration signal arises from actual change of acoustic parameters, not from electrical simulation. Instrument is able to simulate changes in sensitivity enhancement achieved by use of ultrasonic resonators, which cannot be achieved using electrical calibration techniques.

Heyman, J. S.↗

Experimental Constraints on Ureilite Petrogenesis

This experimental study explores the petrogenesis of ureilites by a partial melting/smelting process. Experiments have been performed over temperature (1150-1280 C), pressure (5-12.5 MPa), and low oxygen fugacity (graphite-CO gas) conditions appropriate for a hypothetical ureilite parent body approximately 200 km in size. Experimental and modeling results indicate that a partial melting/smelting model of ureilite petrogenesis can explain many of the unique characteristics displayed by this meteorite group. Compositional information preserved in the pigeonite-olivine ureilites was used to estimate the composition of melts in equilibrium with the ureilites. The results of 20 experiments saturated with olivine, pyroxene, metal, and liquid with appropriate ureilite compositions are used to calibrate the phase coefficients and pressure-temperature dependence of the smelting reaction. The calibrated coefficients are used to model the behavior of a hypothetical residue that is experiencing fractional smelting. The residue is initially olivine-rich and smelting progressively depletes the olivine content and enriches the pyroxene and metal contents of the residues. The modeled residue composition at 1260 C best reproduces the trend of ureilite bulk compositions. The model results also indicate that as a ureilite residue undergoes isothermal decompression smelting over a range of temperatures, Ca/Al values and Cr203 contents are enriched at lower temperatures (below about 1240 C) and tend to decrease at higher temperatures. Therefore, fractional smelting can account for the high Ca/A1 and Cr203 wt% values observed in ureilites. We propose that ureilites were generated from an olivine-rich, cpx-bearing residue. Smelting began when the residue was partially melted and contained liquid, olivine, and carbon. These residues experienced varying degrees of fractional smelting to produce the compositional variability observed within the pigeonite-bearing ureilites. Variations in mineral composition, modal proportions, and isotopic signatures are best described by heterogeneous accretion of the ureilite parent body followed by minimal and variable degrees of igneous processing.

Singletary, Steven↗

Prototype development of a Geostationary Synthetic Thinned Aperture Radiometer (GeoSTAR)

Weather prediction and hurricane tracking would greatly benefit of a continuous imaging capability of a hemisphere at millimeter wave frequencies. We are developing a synthetic thinned aperture radiometer (STAR) prototype operating from 50 to 56 GHz as a ground-based testbed to demonstrate the technologies needed to do full earth disk atmospheric temperature soundings from Geostationary orbit with very high spatial resolution. The prototype consists of a Y-array of 24 MMIC receivers that are compact units implemented with low noise InP MMIC LNAs, second harmonic I-Q mixers, low power IF amplifiers and include internal digital bias control with serial line communication to enable low cost testing and system integration. Furthermore, this prototype STAR includes independent LO and noise calibration signal phase switching circuitry for each arm of the Y-array to verify the operation and calibration of the system.

Millimeter wave low noise amplifiers↗

Automated electronic system for measuring thermophysical properties

Phase-charge coatings are used to measure surface temperature accurately under transient heating conditions. Coating melts when surface reaches calibrated phase-charge temperature. Temperature is monitored by infrared thermometer, and corresponding elapsed time is recorded by electronic data-handling system.

Creel, T. R., Jr.↗

Measurement and Calibration of PSD with Phase-shifting Interferometers

We discuss the instrumental aspects affecting the measurement accuracy when determining PSD with phase shifting interferometers. These include the source coherence, optical train effects, and detector effects. The use of a carefully constructed calibration standard will also be discussed. We will end with a recommended measurement and data handling procedure.

Lehan, J. P.↗

Aquarius Instrument Science Calibration During the Risk Reduction Phase

This final report presents the results of work performed under NASA Grant NAG512726 during the period 15 January 2003 through 30 June 2004. An analysis was performed of a possible vicarious calibration method for use by Aquarius to monitor and stabilize the absolute and relative calibration of its microwave radiometer. Stationary statistical properties of the brightness temperature (T(sub B)) measured by a low Earth orbiting radiometer operating at 1.4135 GHz are considered as a means of validating its absolute calibration. The global minimum, maximum, and average T(sub B) are considered, together with a vicarious cold reference method that detects the presence of a sharp lower bound on naturally occurring values for T(sub B). Of particular interest is the reliability with which these statistics can be extracted from a realistic distribution of T(sub B) measurements that would be observed by a typical sensor. Simulations of measurements are performed that include the effects of instrument noise and variable environmental factors such as the global water vapor and ocean surface temperature, salinity and wind distributions. Global minima can vary widely due to instrument noise and are not a reliable calibration reference. Global maxima are strongly influenced by several environmental factors as well as instrument noise and are even less stationary. Global averages are largely insensitive to instrument noise and, in most cases, to environmental conditions as well. The global average T(sub B) varies at only the 0.1 K RMS level except in cases of anomalously high winds, when it can increase considerably more. The vicarious cold reference is similarly insensitive to instrument effects and most environmental factors. It is not significantly affected by high wind conditions. The stability of the vicarious reference is, however, found to be somewhat sensitive (at the several tenths of Kelvins level) to variations in the background cold space brightness, T(sub c). The global average is much less sensitive to this parameter and so using two approaches together can be mutually beneficial.

Ruf, Christopher S.↗

Preliminary calibration plan for the Advanced Particles and Field Observatory (APAFO) magnetometer experiment

Prelaunch and postlaunch calibration plans for the APAFO magnetometer experiment are presented. A study of tradeoffs between boom length and spacecraft field is described; the results are summarized. The prelaunch plan includes: calibration of the Vector Fluxgate Magnetometer (VFM), Star Sensors, and Scalar Helium Magnetometer (SHM); optical bench integration; and acquisition of basic spacecraft field data. Postlaunch calibration has two phases. In phase one, SHM data are used to calibrate the VFM, total vector magnetic field data are used to calibrate a physical model of the spacecraft field, and both calibrations are refined by iteration. In phase two, corrected vector data are transformed into geocentric coordinates, previously undetected spacecraft fields are isolated, and initial geomagnetic field models are computed. Provided the SHM is accurate to the required 1.0 nT and can be used to calibrate the VFM to the required 3.0- nT accuracy, the tradeoff study indicates that a 12 m boom and a spacecraft field model uncertainty of 5 percent together allow the 1.0 nT spacecraft field error requirement to be met.

Voorhies, C. V.↗

Calibration Test Set for a Phase-Comparison Digital Tracker

An apparatus that generates four signals at a frequency of 7.1 GHz having precisely controlled relative phases and equal amplitudes has been designed and built. This apparatus is intended mainly for use in computer-controlled automated calibration and testing of a phase-comparison digital tracker (PCDT) that measures the relative phases of replicas of the same X-band signal received by four antenna elements in an array. (The relative direction of incidence of the signal on the array is then computed from the relative phases.) The present apparatus can also be used to generate precisely phased signals for steering a beam transmitted from a phased antenna array. The apparatus (see figure) includes a 7.1-GHz signal generator, the output of which is fed to a four-way splitter. Each of the four splitter outputs is attenuated by 10 dB and fed as input to a vector modulator, wherein DC bias voltages are used to control the in-phase (I) and quadrature (Q) signal components. The bias voltages are generated by digital-to-analog- converter circuits on a control board that receives its digital control input from a computer running a LabVIEW program. The outputs of the vector modulators are further attenuated by 10 dB, then presented at high-grade radio-frequency connectors. The attenuation reduces the effects of changing mismatch and reflections. The apparatus was calibrated in a process in which the bias voltages were first stepped through all possible IQ settings. Then in a reverse interpolation performed by use of MATLAB software, a lookup table containing 3,600 IQ settings, representing equal amplitude and phase increments of 0.1 , was created for each vector modulator. During operation of the apparatus, these lookup tables are used in calibrating the PCDT.

Boas, Amy↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗