Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase contrast.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

X-ray Pump-Probe Measurements using a Laser-Plasma Accelerator (Final Report)

This project funded one graduate student, Mario Balcazar, to perform experiments on high power laser facilities to study the application of X-rays generated by laser wakefield accelerated electrons for advanced radiography, in particular X-ray phase contrast imaging of hydrodynamic shocks/instabilities. The work made use of the DOE’s LaserNetUS facilities. We performed dynamic phase-contrast X-ray imaging of the shock generated by a 200 ps duration laser pulse (E = 1 J, I = 10 15 Wcm –2 ) with a 30 µm diameter liquid target, with unprecedented spatio-temporal resolution. This includes multi-shock generation within the liquid jet and plasma instability formation. Innovative electron-beam radiography was used to probe the laser-plasma interplay finding evidence of bilateral heating of the water followed by strong electric field generation. These measurements help explain some of the discrepancies between simulation and experiment and pave the way to better plasma diagnostic systems in HED and ICF physics experiments. This work was performed in collaboration with researchers from Michigan, LLNL, LBL and Sandia National Laboratories, Queen’s University Belfast and Imperial College.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-supervised physics-informed generative networks for phase retrieval from a single X-ray hologram

X-ray phase contrast imaging significantly improves the visualization of structures with weak or uniform absorption, broadening its applications across a wide range of scientific disciplines. Propagation-based phase contrast is particularly suitable for time- or dose-critical in vivo/in situ/operando (tomography) experiments because it requires only a single intensity measurement. However, the phase information of the wave field is lost during the measurement and must be recovered. Conventional algebraic and iterative methods often rely on specific approximations or boundary conditions that may not be met by many samples or experimental setups. In addition, they require manual tuning of reconstruction parameters by experts, making them less adaptable for complex or variable conditions. Here we present a self-learning approach for solving the inverse problem of phase retrieval in the near-field regime of Fresnel theory using a single intensity measurement (hologram). A physics-informed generative adversarial network is employed to reconstruct both the phase and absorbance of the unpropagated wave field in the sample plane from a single hologram. Unlike most state-of-the-art deep learning approaches for phase retrieval, our approach does not require paired, unpaired, or simulated training data. This significantly broadens the applicability of our approach, as acquiring or generating suitable training data remains a major challenge due to the wide variability in sample types and experimental configurations. The algorithm demonstrates robust and consistent performance across diverse imaging conditions and sample types, delivering quantitative, high-quality reconstructions for both simulated data and experimental datasets acquired at beamline P05 at PETRA III (DESY, Hamburg), operated by Helmholtz-Zentrum Hereon. Furthermore, it enables the simultaneous retrieval of both phase and absorption information.

36 MATERIALS SCIENCE↗

Information transfer as a framework for optimized phase imaging

In order to efficiently image a non-absorbing sample (a phase object), dedicated phase contrast optics are required. Typically, these optics are designed with the assumption that the sample is weakly scattering, implying a linear relation between a sample’s phase and its transmission function. In the strongly scattering, nonlinear case, the standard optics are ineffective, and the transfer functions used to characterize them are uninformative. We use the Fisher information (FI) to assess the efficiency of various phase imaging schemes and to calculate an information transfer function (ITF). We show that a generalized version of Zernike phase contrast is efficient given sufficient prior knowledge of the sample. We show that with no prior knowledge, a random sensing measurement yields a significant fraction of the available information. Finally, we introduce a generalized approach to common path interferometry that can be optimized to prioritize sensitivity to particular sample features. Each of these measurements can be performed using Fourier lenses and phase masks.

Koppell, Stewart↗

Shock compression of a low-density carbon foam

Porous polymer foams are found in numerous applications where they may be subjected to dynamic compression. The shockwave properties of polymer foams have several features that make shock Hugoniot measurements and interpretation challenging. Here, we present a comparison of dynamic X-ray phase contrast imaging and traditional optical velocimetry approaches to measuring the shocked states for a low-density carbon foam. Overall, dynamic X-ray phase contrast imaging was found to reduce errors associated with the measured Hugoniot states. In this study, the foam exhibits anomalous compression as expected due to its high initial porosity arising from shock heating.

36 MATERIALS SCIENCE↗

Phase and contrast moiré signatures in two-dimensional cone beam interferometry

Neutron interferometry has played a distinctive role in fundamental science and characterization of materials. Moiré neutron interferometers are candidate next-generation instruments: they offer microscopy-like magnification of the signal, enabling direct camera recording of interference patterns across the full neutron wavelength spectrum. Here we demonstrate the extension of phase-grating moiré interferometry to two-dimensional geometries. Our fork-dislocation phase gratings reveal phase singularities in the moiré pattern, and we explore orthogonal moiré patterns with two-dimensional phase gratings. Our measurements of phase topologies and gravitationally induced phase shifts are in good agreement with theory. These techniques can be implemented in existing neutron instruments to advance interferometric analyses of emerging materials and precision measurements of fundamental constants. Published by the American Physical Society 2024

Sarenac, D. (ORCID:0000000185753367)↗

Single Electron Self-coherence and Its Wave/Particle Duality in the Electron Microscope

Intensities in high-resolution phase-contrast images from electron microscopes build up discretely in time by detecting single electrons. A wave description of pulse-like coherent-inelastic interaction of an electron with matter implies a time-dependent coexistence of coherent partial waves. Their superposition forms a wave package by phase decoherence of 0.5 - 1 radian with Heisenbergs energy uncertainty ΔE H = $\hbar$/2 Δt -1 matching the energy loss ΔE of a coherent-inelastic interaction and sets the interaction time Δt. In these circumstances, the product of Planck's constant and the speed of light hc is given by the product of the expression for temporal coherence λ 2 /Δλ and the energy loss ΔE. Experimentally, the self-coherence length was measured by detecting the energy-dependent localization of scattered, plane matter waves in surface proximity exploiting the Goos–Hänchen shift. Chromatic-aberration Cc-corrected electron microscopy on boron nitride (BN) proves that the coherent crystal illumination and phase contrast are lost if the self-coherence length shrinks below the size of the crystal unit cell at ΔE > 200 eV. Finally, in perspective, the interaction time of any matter wave compares with the lifetime of a virtual particle of any elemental interaction, suggesting the present concept of coherent-inelastic interactions of matter waves might be generalizable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗

Phase-Shifting Zernike Interferometer Wavefront Sensor

The canonical Zernike phase-contrast technique1,2,3,4 transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/D) of the PSF which is intermediate between the input and output planes. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective. Second, the phase shift in the central core of the PSF is dynamic and or arbitrary size. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument

wavefront sensing↗

Experimental Study of the Fundamental Properties of Warm Dense Mixtures

The aim of the proposed research was to provide a multi-scale study of the properties of warm dense hydrocarbons, by studying the thermodynamic properties through the equation of state and the microscopic properties by x-ray scattering. Understanding the fundamental properties of warm dense mixtures is an intellectual challenge due to the complexity of the system. Unlike liquids or gases, where constituent particle interactions occur through collisions or bonding between valence electrons, in these strongly coupled systems the atoms will be partially ionized and compressed so tightly together that interactions between the inner core electrons can play a role in the systems chemistry. Advances in computational capabilities and development of new theoretical models have been used to predict the properties of mixtures but there is currently no experimental data of the fundamental interaction between the particles in mixtures to test these predictions against. The proposed research was to experimentally investigate the interaction of the different species in hydrocarbons by measuring the compressibility of substances with different carbon and hydrogen ratios and the complexity of the microscopic interactions through elastic and inelastic x-ray scattering. To study the bulk properties of warm dense hydrocarbons we established the Warm Dense Matter Research Laboratory (WDMRL) in the Institute for Shock Physics at Washington State University. The goal was for experiments in the WDMRL to determine shock loading conditions of interest in the hydrocarbon mixtures. We planned on using Hugoniot EOS measurements and a range of carbon and hydrogen concentrations to determine conditions when the EOS of the mixture varied significantly from that of the classical mixing model. Even though shock transit measurements through aluminum foils suggested pressures upto 400GPa, the experiments in the WDMRL were unsuccessful in getting usable shockwave compression data above 100GPa in polystyrene which was below the pressure of interest for hydrocarbon mixtures (>200GPa). To complete the project, we tested a technique using x-ray phase contrast imaging to map the location of tracer layers in a test sample of polycarbonate to record the material motion in dynamically compressed samples. A technique that will be useful for future warm dense matter experiments. These experiments used <200nm gold layers in polycarbonate samples to measure the material velocity and shock speed using x-ray phase contrast imaging. These results were compared to continuum surface measurements performed at ISP and show that the tracer layer technique can measure hydrodynamic properties accurately in dynamically compressed materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AFM Studies of Lunar Soils and Application to the Mars 2001 Mission

The upcoming Mars 01 mission will carry an Atomic Force Microscope (AFM) as part of the Mars Environmental Compatibility Assessment (MECA) instrument. By operating in a tapping mode, the AFM is capable of sub-nanometer resolution in three dimensions and can distinguish between substances of different compositions by employing phase contrast imaging. To prepare for the Mars 01 mission, we are testing the AFM on a lunar soil to determine its ability to define particle shapes and sizes and grain-surface textures. The test materials are from the Apollo 17 soil 79221, which is a mixture of agglutinates, impact and volcanic beads, and mare and highland rock and mineral fragments. The majority of the lunar soil particles are less than 100 microns in size, comparable to the sizes estimated for martian dust. We have used the AFM to examine several different soil particles at various resolutions. The instrument has demonstrated the ability to identify parallel ridges characteristic of twinning on a 150 micron plagioclase feldspar particle. Extremely small (10-100 nanometer) adhering particles are visible on the surface of the feldspar grain, and they appear elongate with smooth surfaces. Phase contrast imaging of the nanometer particles shows several compositions to be present. When the AFM was applied to a 100 micron glass spherule, it was possible to define an extremely smooth surface; this is in clear contrast to results from a basalt fragment which exhibited a rough surface texture. Also visible on the surface of the glass spherule were chains of 100 nanometer and smaller impact melt droplets. For the '01 Mars mission, the AFM is intended to define the size and shape distributions of soil particles, in combination with the NMCA optical microscope system and images from the Robot Arm Camera (RAC). These three data sets will provide a means of assessing potentially hazardous soil and dust properties. The study that we have conducted on the lunar soils now suggests that the NMCA experiment will be able to define grain transport and weathering processes. For example, it should be possible to determine if Martian grains have been subjected to aeolian or water transport, volcanic activity, impact melting processes, in-situ weathering, and a host of other processes. Additionally, textural maturity could be assessed (via freshness and form of fracture patterns and grain shapes). Thus, the AFM has the potential to shed new light on Martian surface processes by adding the submicroscopic dimension to planetary investigations.

Weitz, C. M.↗

Deformation heterogeneity and intragrain lattice misorientation in high strength contrast, dual-phase bridgmanite/periclase

A bridgmanite/periclase aggregate is investigated due to its prevalence in the Earth’s lower mantle and its importance for understanding geodynamic processes. In dual-phase polycrystalline aggregates, both strength contrast between phases and single crystal elastic and plastic anisotropy are known to influence the development of intragrain misorientation, and the evolution of crystallographic texture. In this study, full-field crystal plasticity simulations are performed with a finite element solution method, and applied to an aggregate of a mechanically strong orthorhombic phase with perovskite structure (bridgmanite, MgSiO 3 ), and a relatively weaker cubic phase (periclase, MgO). The relative strengths of the phases are parameterized to elucidate the effect that strength contrast has on texture evolution and single-phase simulations are performed for comparison. Altogether, results indicate that the relative strength between the two phases influences the development of plasticity, and the overall texture evolution. Results are discussed in light of trends related to the evolution of plasticity and misorientation in the aggregate, and their dependence on both the strength contrast between phases as well as the spatial distribution of grains and phases.

36 MATERIALS SCIENCE↗

Simultaneous imaging and diffraction in the dynamic diamond anvil cell

The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hollow Ptychography: Toward Simultaneous 4D Scanning Transmission Electron Microscopy and Electron Energy Loss Spectroscopy

With the recent development of high-acquisition-speed pixelated detectors, 4D scanning transmission electron microscopy (4D-STEM) is becoming routinely available in high-resolution electron microscopy. 4D-STEM acts as a “universal” method that provides local information on materials that is challenging to extract from bulk techniques. It extends conventional STEM imaging to include super-resolution techniques and to provide quantitative phase-based information, such as differential phase contrast, ptychography, or Bloch wave phase retrieval. However, an important missing factor is the chemical and bonding information provided by electron energy loss spectroscopy (EELS). 4D-STEM and EELS cannot currently be acquired simultaneously due to the overlapping geometry of the detectors. Here, the feasibility of modifying the detector geometry to overcome this challenge for bulk specimens is demonstrated, and the use of a partial or defective detector for ptycholgaphic structural imaging is explored. Here, results show that structural information beyond the diffraction-limit and chemical information from the material can be extracted together, resulting in simultaneous multi-modal measurements, adding the additional dimensions of spectral information to 4D datasets.

4D-scanning transmitting electron microscopy (STEM↗

Time resolved in-situ multi-contrast X-ray imaging of melting in metals

In this work, the application of a time resolved multi-contrast beam tracking technique to the investigation of the melting and solidification process in metals is presented. The use of such a technique allows retrieval of three contrast channels, transmission, refraction and dark-field, with millisecond time resolution. We investigated different melting conditions to characterize, at a proof-of-concept level, the features visible in each of the contrast channels. We found that the phase contrast channel provides a superior visibility of the density variations, allowing the liquid metal pool to be clearly distinguished. Refraction and dark-field were found to highlight surface roughness formed during solidification. This work demonstrates that the availability of the additional contrast channels provided by multi-contrast X-ray imaging delivers additional information, also when imaging high atomic number specimens with a significant absorption.

36 MATERIALS SCIENCE↗

Element differentiation with a Hartmann- based X-ray phase imaging system

Significant efforts are currently ongoing in X-ray imaging to provide multimodal imaging systems, targeting better sensitivity and specificity for both biomedical or non-destructive testing applications. Knowing the elemental composition of specific structures, such as breast microcalcifications in mammography, would help to differentiate malign and benign tumours. Standard X-ray Phase Contrast Imaging techniques provide only qualitative information on elements with similar absorption properties. However, their chemical composition can be determined from the measurement of the phase as it is directly related to the optical index of elemental materials. We will show new experimental results obtained with an X-ray phase imaging system based on a Hartmann mask. Early data treatment succeeded in retrieving both the real and imaginary parts of the refractive index. The system demonstrates the capability to discriminate materials based on elemental composition.

36 MATERIALS SCIENCE↗

Phase retrieval for refraction-enhanced x-ray radiography using a deep neural network

X-ray refraction-enhanced radiography (RER) or phase contrast imaging is widely used to study internal discontinuities within materials. The resulting radiograph captures both the decrease in intensity caused by material absorption along the x-ray path, as well as the phase shift, which is highly sensitive to gradients in density. A significant challenge lies in effectively analyzing the radiographs to decouple the intensity and phase information and accurately ascertain the density profile. Conventional algorithms often yield ambiguous and unrealistic results due to difficulties in including physical constraints and other relevant information. We have developed an algorithm that uses a deep neural network to address these issues and applied it to extract the detailed density profile from an experimental RER. To generalize the applicability of our algorithm, we have developed a technique that quantitatively evaluates the complexity of the phase retrieval process based on the characteristics of the sample and the configuration of the experiment. Accordingly, this evaluation aids in the selection of the neural network architecture for each specific case. Beyond RER, the model has potential applications for other diagnostics where phase retrieval analysis is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗