Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Maturing CCD Photon-Counting Technology for Space Flight

This paper discusses charge blooming and starlight saturation - two potential technical problems - when using an Electron Multiplying Charge Coupled Device (EMCCD) type detector in a high-contrast instrument for imaging exoplanets. These problems especially affect an interferometric type coronagraph - coronagraphs that do not use a mask to physically block starlight in the science channel of the instrument. These problems are presented using images taken with a commercial Princeton Instrument EMCCD camera in the Goddard Space Flight Center's (GSFC), Interferometric Coronagraph facility. In addition, this paper discusses techniques to overcome such problems. This paper also discusses the development and architecture of a Field Programmable Gate Array and Digital-to-Analog Converter based shaped clock controller for a photon-counting EMCCD camera. The discussion contained here will inform high-contrast imaging groups in their work with EMCCD detectors.

Mallik, Udayan↗

InGaAsP Avalanche Photodetectors for Non-Gated 1.06 micrometer Photon-Counting Receivers

The efficient detection of single photons at 1.06 micron is of considerable interest for lidar/ladar systems designed for remote sensing an d ranging as well as for free-space optical transmission in photon-st arved applications. However, silicon-based single photon avalanche diodes (SPADs) used at shorter wavelengths have very low single photon d etection efficiency (approximately 1 - 2%) at 1.06 micron, and InP/In GaAs SPADs designed for telecommunications wavelengths near 1.5 micro n exhibit high dark count rates that generally inhibit non-gated (free-running) operation. To bridge this "single photon detection gap" for wavelengths just beyond 1 micron, we have developed high performance , large area (80 - 200 micron diameter) InP-based InGaAsP quaternary absorber SPADs optimized for operation at 1.06 micron and based on a highly reliable planar geometry avalanche photodiode structure. We wil l show that dark count rates are sufficiently low to allow for non-ga ted operation while achieving detection efficiencies far surpassing t hose found for Si SPADs. At a detection efficiency of 10%, 80 micron diameter devices exhibit dark count rates below 1000 Hz and count rate s of at least 3 MHz when operated at -40 C. Significantly higher dete ction efficiencies (30 - 50%) are achievable with acceptable tradeoff s in dark count rate. In this paper, we will also discuss performance modeling for these devices and compare their behavior with longer wav elength InP-based InGaAs ternary absorber SPADs fabricated on a relat ed device design platform.

Itzler, Mark A.↗

Solid-state Image Sensor with Focal-plane Digital Photon-counting Pixel Array

A solid-state focal-plane imaging system comprises an NxN array of high gain. low-noise unit cells. each unit cell being connected to a different one of photovoltaic detector diodes, one for each unit cell, interspersed in the array for ultra low level image detection and a plurality of digital counters coupled to the outputs of the unit cell by a multiplexer(either a separate counter for each unit cell or a row of N of counters time shared with N rows of digital counters). Each unit cell includes two self-biasing cascode amplifiers in cascade for a high charge-to-voltage conversion gain (greater than 1mV/e(-)) and an electronic switch to reset input capacitance to a reference potential in order to be able to discriminate detection of an incident photon by the photoelectron (e(-))generated in the detector diode at the input of the first cascode amplifier in order to count incident photons individually in a digital counter connected to the output of the second cascade amplifier. Reseting the input capacitance and initiating self-biasing of the amplifiers occurs every clock cycle of an integratng period to enable ultralow light level image detection by the may of photovoltaic detector diodes under such ultralow light level conditions that the photon flux will statistically provide only a single photon at a time incident on anyone detector diode during any clock cycle.

Fossum, Eric R.↗

Determination of Local Slope on the Greenland Ice Sheet Using a Multibeam Photon-Counting Lidar in Preparation for the ICESat-2 Mission

The greatest changes in elevation in Greenland and Antarctica are happening along the margins of the ice sheets where the surface frequently has significant slopes. For this reason, the upcoming Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) mission utilizes pairs of laser altimeter beams that are perpendicular to the flight direction in order to extract slope information in addition to elevation. The Multiple Altimeter Beam Experimental Lidar (MABEL) is a high-altitude airborne laser altimeter designed as a simulator for ICESat-2. The MABEL design uses multiple beams at fixed angles and allows for local slope determination. Here, we present local slopes as determined by MABEL and compare them to those determined by the Airborne Topographic Mapper (ATM) over the same flight lines in Greenland. We make these comparisons with consideration for the planned ICESat-2 beam geometry. Results indicate that the mean slope residuals between MABEL and ATM remain small (< 0.05 degrees) through a wide range of localized slopes using ICESat-2 beam geometry. Furthermore, when MABEL data are subsampled by a factor of 4 to mimic the planned ICESat-2 transmit-energy configuration, the results are indistinguishable from the full-data-rate analysis. Results from MABEL suggest that ICESat-2 beam geometry and transmit-energy configuration are appropriate for the determination of slope on approx. 90-m spatial scales, a measurement that will be fundamental to deconvolving the effects of surface slope from the ice-sheet surface change derived from ICESat-2.

Photon-Counting↗

Determination of Local Slope on the Greenland Ice Sheet Using a Multibeam Photon-Counting Lidar in Preparation for the ICESat-2 Mission

The greatest changes in elevation in Greenland and Antarctica are happening along the margins of the ice sheets where the surface frequently has significant slopes. For this reason, the upcoming Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) mission utilizes pairs of laser altimeter beams that are perpendicular to the flight direction in order to extract slope information in addition to elevation. The Multiple Altimeter Beam Experimental Lidar (MABEL) is a high-altitude airborne laser altimeter designed as a simulator for ICESat-2. The MABEL design uses multiple beams at fixed angles and allows for local slope determination. Here, we present local slopes as determined by MABEL and compare them to those determined by the Airborne Topographic Mapper (ATM) over the same flight lines in Greenland. We make these comparisons with consideration for the planned ICESat-2 beam geometry. Results indicate that the mean slope residuals between MABEL and ATM remain small (< 0.05◦) through a wide range of localized slopes using ICESat-2 beam geometry. Furthermore, when MABEL data are subsampled by a factor of 4 to mimic the planned ICESat-2 transmit-energy configuration, the results are indistinguishable from the full-data-rate analysis. Results from MABEL suggest that ICESat-2 beam geometry and transmit-energy configuration are appropriate for the determination of slope on ∼90-m spatial scales, a measurement that will be fundamental to deconvolving the effects of surface slope from the ice-sheet surface change derived from ICESat-2.

Greenland↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

Fiber-Detector Subsystem Loss Comparison for A Ground-Based Photon-Counting Optical Receiver

A comparative study of the losses associated with fiber-coupled single-photon detectors in two different configurations, each with the goal of receiving a pulsed-position modulated signal with a maximum data rate of 267 Mbps. First, we consider a 7x1 few-mode-fiber (FMF) photonic lantern coupled to seven individual superconducting nanowire single photon detectors (SNSPDs). In the second configuration we assess a single FMF coupled to a 16-channel monolithic SNSPD array. In each case we measure and compare combined fiber coupling, SNSPD blocking, and system efficiency losses under emulated atmospheric turbulence conditions. We address subsystem impact on link performance and analyze feasibility for future NASA lunar and deep-space optical communications missions.

Fiber optics↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Fiber-Detector Subsystem Loss Comparison for A Ground-Based Photon-Counting Optical Receiver

In this paper we present a comparative study of the losses associated with fiber-coupled single-photon detectors in two different configurations, each with the goal of receiving a pulsed-position modulated signal with a maximum data rate of 267 Mbps. First, we consider a 7x1 few-mode-fiber (FMF) photonic lantern coupled to seven individual superconducting nanowire single photon detectors (SNSPDs). In the second configuration we assess a single FMF coupled to a 16-channel monolithic SNSPD array. In each case we measure and compare combined fiber coupling, SNSPD blocking, and system efficiency losses under emulated atmospheric turbulence conditions. We address subsystem impact on link performance and analyze feasibility for future NASA lunar and deep-space optical communications missions.

Fiber optics↗

Photon counting with a self-scanned diode array.

A self-scanned diode array may be used as temporary storage for individual photons if enough gain is provided by an image intensifier or electron multiplier to provide a detectable signal from each input event.

Mcnall, J. F.↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time-pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

NASA's Photon-Counting SLR2000 Satellite Laser Ranging System: Progress and Applications

NASA's new unmanned SLR2000 system is designed to track, with millimeter precision and using single photon returns, a constellation of roughly 24 retroreflector-equipped satellites, which range in altitude from about 300 km to 20,000 km. Totally autonomous operation and a common engineering configuration are expected to greatly reduce station operations costs relative to NASA's current manned systems. The system has also been designed with a goal of significantly lowering replication costs. All of the prototype components and subsystems have been completed and tested and have substantially met the original specifications. The prototype system is presently undergoing final integration and testing in a dedicated shelter with an azimuth tracking dome synchronized to the optical tracking mount. The facility also features a number of security features such as security cameras and sensors designed to detect power or thermal control problems or entry by unauthorized personnel. Field tests are in progress. The present paper provides an overview of the various subsystems and test results to date. The meteorological subsystem, which has operated successfully in the field for almost three years, consists of several sensors which measure: (1) pressure, temperature, and relative humidity; (2) wind speed and direction; (3) ground visibility and precipitation; and (4) local cloud cover as a function of station azimuth and elevation (day and night). A "pseudo-operator" software program interprets the sensor readings and modifies satellite tracking priorities based on local meteorological conditions.

Degnan, John J.↗

Coding for optical channels with photon-counting

The problem of coding for Pierce's recent model for optical communications is studied. It was concluded that for any positive rate rho (measured in nats per photon), the best code of length n has an error probability bounded by an exponentially decaying function of n. Explicit practical schemes are shown for rho less than or = to 1; and evidence is given that rho approximating 1 may be the practical limit for optical communication.

Mceliece, R. J.↗

Design and Performance of a Multi-mode Photon-counting Receiver for the NASA O2O Mission

The NASA Orion O2O mission was designed and tested to support high-rate bi-directional optical communications between one of multiple ground sites and a crewed capsule during a 10-day mission. This paper focuses on the design and performance of the receiver that will be based at the NASA White Sands Complex, New Mexico, USA. The main receiver components consist of two 40-cm apertures, each coupled to a specialty multi-mode optical fiber; each fiber coupled to a custom array of superconducting nanowire single-photon detectors; a high-speed, high-channel-count time-to-digital converter; and custom digitizing electronics to perform deserialization, demodulation, clock recovery, and forward error correction with a powerful serially-concatenated pulse-position-modulation turbo code. We show error-free data communication performance up to the maximum required data rate of 267 Mb/s.

optical↗

MABEL Photon-Counting Laser Altimetry Data in Alaska for ICESat-2 Simulations and Development

Multiple Altimeter Beam Experimental Lidar (MABEL) maps Alaskan crevasses in detail, using 50 of the expected along-track Advanced Topographic Laser Altimeter System (ATLAS) signal-photon densities over summer ice sheets. Ice, Cloud, and Land Elevation Satellite 2 (ICESat-2) along-track data density, and spatial data density due to the multiple-beam strategy, will provide a new dataset to mid-latitude alpine glacier researchers.

Landsat-8↗