Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cumulative sum quality control for calibrated breast density measurements

Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative sensitivity of Normalized Difference Vegetation Index (NDVI) and Microwave Polarization Difference Index (MPDI) for vegetation and desertification monitoring

A simple equation relating the Microwave Polarization Difference Index (MPDI) and the Normalized Difference Vegetation Index (NDVI) is proposed which represents well data obtained from Nimbus 7/SMMR at 37 GHz and NOAA/AVHRR Channels 1 and 2. It is found that there is a limit which is characteristic of a particular type of cover for which both indices are equally sensitive to the variation of vegetation, and below which MPDI is more efficient than NDVI. The results provide insight into the relationship between water content and chlorophyll absorption at pixel size scales.

Becker, Francois↗

Physically-based parameterization of spatially variable soil and vegetation using satellite multispectral data

A stochastic-geometric landsurface reflectance model is formulated and tested for the parameterization of spatially variable vegetation and soil at subpixel scales using satellite multispectral images without ground truth. Landscapes are conceptualized as 3-D Lambertian reflecting surfaces consisting of plant canopies, represented by solid geometric figures, superposed on a flat soil background. A computer simulation program is developed to investigate image characteristics at various spatial aggregations representative of satellite observational scales, or pixels. The evolution of the shape and structure of the red-infrared space, or scattergram, of typical semivegetated scenes is investigated by sequentially introducing model variables into the simulation. The analytical moments of the total pixel reflectance, including the mean, variance, spatial covariance, and cross-spectral covariance, are derived in terms of the moments of the individual fractional cover and reflectance components. The moments are applied to the solution of the inverse problem: The estimation of subpixel landscape properties on a pixel-by-pixel basis, given only one multispectral image and limited assumptions on the structure of the landscape. The landsurface reflectance model and inversion technique are tested using actual aerial radiometric data collected over regularly spaced pecan trees, and using both aerial and LANDSAT Thematic Mapper data obtained over discontinuous, randomly spaced conifer canopies in a natural forested watershed. Different amounts of solar backscattered diffuse radiation are assumed and the sensitivity of the estimated landsurface parameters to those amounts is examined.

Jasinski, Michael F.↗

Multiscale vector fields for image pattern recognition

A uniform processing framework for low-level vision computing in which a bank of spatial filters maps the image intensity structure at each pixel into an abstract feature space is proposed. Some properties of the filters and the feature space are described. Local orientation is measured by a vector sum in the feature space as follows: each filter's preferred orientation along with the strength of the filter's output determine the orientation and the length of a vector in the feature space; the vectors for all filters are summed to yield a resultant vector for a particular pixel and scale. The orientation of the resultant vector indicates the local orientation, and the magnitude of the vector indicates the strength of the local orientation preference. Limitations of the vector sum method are discussed. Investigations show that the processing framework provides a useful, redundant representation of image structure across orientation and scale.

Low, Kah-Chan↗

First Look at Landsat-7 Mission Performance: Technical and Operational Results to Date

A primary goal of the current Landsat-7 mission, launched on April 15, 1999, is to acquire and refresh on a seasonal basis, calibrated ata sets of multispectral digital imagery of the landmass of the Earth The Enhanced Thematic Mapper Plus (ETM+) imager flown on Landsat-7 provides ground spatial resolutions in the panchromatic, reflective and emissive bands of 15, 30 and 60 meters, respectively, for a nominal scene 183 km wide by 170 km long. This mission not only builds on the invaluable 27-year continuous archive of thematic images of the Earth provided by previous Landsat satellites, it also inaugurates a new era of robust data acquisition with an emphasis on global change science. The newly developed Long Term Acquisition Plan (LTAP) is being used to optimize the systematic collection of data from all parts of the globe, populating the U.S.-held archive at the USGS EROS Data Center (EDC) with over 90,000 Landsat scene per year . An additional 73,000 Images are expected to be acquired each year by several international ground stations, for a total downlink of Landsat7 data in excess of 100 terabytes per year. Nearly 20,000 scan of Landsat-7 ETM+ data have already been acquired in the first 100 days of the mission. Early results derived from assessments of the ETM+ instrument, the spacecraft, and the ground processing systems indicate that the image quality is outstanding, clearly the best ever provided by any Landsat mission. Sensor radiometric background stability after the first 100 days in orbit is approximately 0.1 percent. Stability of the Full Aperture Solar Calibrator is approximately 0.3 percent, and mid-scale per pixel noise is approximately 0.6 percent. A ground processing system has been implemented at EDC which is capable of capturing, processing and archiving 250 Landsat scenes 9 per day, and delivering 100 scene products to seems each day. The cost of a systematically-processed Level 1 product has been dropped dramatically to $600, end there is no longer any copyright protection an the data. The net result is that the use of Landsat ETM+ data is expected to grow dramatically, and this growth is expected to benefit all facets of the land remote sensing community.

Williams, Darrel L.↗

Comparison of Jovian and Terrestrial Lightning as Observed from Space

We compare the images of Jovian lightning taken by Galileo spacecraft with the images of terrestrial lightning observed by Lightning Imaging Spectrometer (LIS) onboard the TERRA spacecraft. Both data sets have good spatial resolution: Galileo's pixel is 25 km, or about half the atmospheric scale height, LIS pixel is 3-6 km, also about half of the scale height. This good resolution allows us to see that both Jovian and terrestrial lightning spots look diffuse because of the scattering in the clouds above. Previously we used the appearance of the diffuse spots on Jupiter to model lightning depths and the opacity and shape of the overlying clouds (Dyudina and Ingersoll, 2000). The comparison with LIS data allowed us to verify that the model is valid for terrestrial lightning. The irregular shapes of large terrestrial lightning suggests 30-km scale horizontal bolts. On Jupiter the spots, projected onto the horizontal plane, are nearly circular suggesting that the large size of the spots is mostly due to the horizontal diffusion of the photons scattered in the clouds. Unlike the Galileo observations, LIS has fine temporal resolution of 2 ms, or about 250 frames per single lightning flash. We will discuss the temporal evolution of terrestrial flashes and its implications for Jupiter.

Dyudina, Ulyana A.↗

Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring

A document describes the fabrication of a two-dimensional microcalorimeter array that uses microstrip wiring and integrated heat sinking to enable use of high-performance pixel designs at kilopixel scales (32 X 32). Each pixel is the high-resolution design employed in small-array test devices, which consist of a Mo/Au TES (transition edge sensor) on a silicon nitride membrane and an electroplated Bi/Au absorber. The pixel pitch within the array is 300 microns, where absorbers 290 microns on a side are cantilevered over a silicon support grid with 100-micron-wide beams. The high-density wiring and heat sinking are both carried by the silicon beams to the edge of the array. All pixels are wired out to the array edge. ECR (electron cyclotron resonance) oxide underlayer is deposited underneath the sensor layer. The sensor (TES) layer consists of a superconducting underlayer and a normal metal top layer. If the sensor is deposited at high temperature, the ECR oxide can be vacuum annealed to improve film smoothness and etch characteristics. This process is designed to recover high-resolution, single-pixel x-ray microcalorimeter performance within arrays of arbitrarily large format. The critical current limiting parts of the circuit are designed to have simple interfaces that can be independently verified. The lead-to-TES interface is entirely determined in a single layer that has multiple points of interface to maximize critical current. The lead rails that overlap the TES sensor element contact both the superconducting underlayer and the TES normal metal

Chervenak, James↗

THE STAR-FORMATION RELATION FOR REGIONS IN THE GALACTIC PLANE: THE EFFECT OF SPATIAL RESOLUTION

We examined the relations between molecular gas surface density and star-formation rate surface density in an 11 deg{sup 2} region of the Galactic plane. Dust continua at 1.1 mm from the Bolocam Galactic Plane Survey and 22 μm emission from the Wide-field Infrared Survey Explorer (WISE) all-sky survey were used as tracers of molecular gas and the star-formation rate, respectively, across the Galactic longitude of 31.5 ≥ l ≥ 20.5 and Galactic latitude of 0.5 ≥ b ≥ –0.5. The relation was studied over a range of resolutions from 33'' to 20' by convolving images to larger scales. The pixel-by-pixel correlation between 1.1 mm and 22 μm increases rapidly at small scales and levels off at the scale of 5'-8'. We studied the star-formation relation based on a pixel-by-pixel analysis and on an analysis of the 1.1 mm and 22 μm peaks. The star-formation relation was found to be nearly linear with no significant changes in the form of the relation across all spatial scales, and it lies above the extragalactic relation from Kennicutt. The average gas-depletion time is ≈200 Myr and does not change significantly at different scales, but the scatter in the depletion time decreases as the scale increases.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Processing for Binarization Enhancement via Fuzzy Reasoning

A technique for enhancing a gray-scale image to improve conversions of the image to binary employs fuzzy reasoning. In the technique, pixels in the image are analyzed by comparing the pixel's gray scale value, which is indicative of its relative brightness, to the values of pixels immediately surrounding the selected pixel. The degree to which each pixel in the image differs in value from the values of surrounding pixels is employed as the variable in a fuzzy reasoning-based analysis that determines an appropriate amount by which the selected pixel's value should be adjusted to reduce vagueness and ambiguity in the image and improve retention of information during binarization of the enhanced gray-scale image.

Dominguez, Jesus A.↗

Quantum pixel representations and compression for N-dimensional images

Abstract We introduce a novel and uniform framework for quantum pixel representations that overarches many of the most popular representations proposed in the recent literature, such as (I)FRQI, (I)NEQR, MCRQI, and (I)NCQI. The proposed QPIXL framework results in more efficient circuit implementations and significantly reduces the gate complexity for all considered quantum pixel representations. Our method scales linearly in the number of pixels and does not use ancilla qubits. Furthermore, the circuits only consist of $$R_y$$ R y gates and $$\text {CNOT}$$ CNOT gates making them practical in the NISQ era. Additionally, we propose a circuit and image compression algorithm that is shown to be highly effective, being able to reduce the necessary gates to prepare an FRQI state for example scientific images by up to 90% without sacrificing image quality. Our algorithms are made publicly available as part of , a Quantum Image Pixel Library.

97 MATHEMATICS AND COMPUTING↗

Modeling misregistration and related effects on multispectral classification

Any noise in measurements (due to the scene, sensor, or the analog to digital process) causes a finite fraction of measurements to fall outside of the classification limits. For field boundaries, where the misregistration effects are felt, the misregistration causes the border in a given (set of) band(s) to be closer than expected to a given pixel, so that the mixed materials in the pixels cause additional pixels to fall outside of the class limits. Considerations of the transient distance involved in the difference in brightness between adjacent fields, when scaled to "per pixel", allow the estimation of the width of the border zones. The entire problem is then scaled to field sizes to allow estimation of the global effects. This approach allows the estimation of the accuracy of multispectral classification which might be expected for field interiors, the useful number of quantization bits, and one set of criteria for an unbiased classifier.

Billingsley, F. C.↗

Progress in the Development of Mo-Au Transition-Edge Sensors for X-Ray Spectroscopy

X-ray microcalorimeters using transition-edge sensors (TES) show great promise for use in astronomical x-ray spectroscopy. We have obtained very high energy resolution (2.8 electronvolts at 1.5 kiloelectronvolts and 3.7 electronvolts at 3.3 kiloelectronvolts) in a large, isolated TES pixel using a Mo/Au proximity-effect bilayer on a silicon nitride membrane. We will discuss the performance and our characterization of that device. In order to be truly suitable for use behind an x-ray telescope, however, such devices need to be arrayed with a pixel size and focal-plane coverage commensurate with the telescope focal length and spatial resolution. Since this requires fitting the TES and its thermal link, a critical component of each calorimeter pixel, into a far more compact geometry than has previously been investigated, we must study the fundamental scaling laws in pixel optimization. We have designed a photolithography mask that will allow us to probe the range in thermal conductance that can be obtained by perforating the nitride membrane in a narrow perimeter around the sensor. This mask will also show the effects of reducing the TES area. Though we have not yet tested devices of the compact designs, we will present our progress in several of the key processing steps and discuss the parameter space of our intended investigations.

of Magnetic Calorimeters for Applications in X-ray↗

INCREASING EVIDENCE FOR HEMISPHERICAL POWER ASYMMETRY IN THE FIVE-YEAR WMAP DATA

Motivated by the recent results of Hansen et al. concerning a noticeable hemispherical power asymmetry in the Wilkinson Microwave Anisotropy Probe (WMAP) data on small angular scales, we revisit the dipole-modulated signal model introduced by Gordon et al.. This model assumes that the true cosmic microwave background signal consists of a Gaussian isotropic random field modulated by a dipole, and is characterized by an overall modulation amplitude, A, and a preferred direction, p-hat. Previous analyses of this model have been restricted to very low resolution (i.e., 3.{sup 0}6 pixels, a smoothing scale of 9 deg. FWHM, and l {approx}< 40) due to computational cost. In this paper, we double the angular resolution (i.e., 1.{sup 0}8 pixels and 4.{sup 0}5 FWHM smoothing scale), and compute the full corresponding posterior distribution for the five-year WMAP data. The results from our analysis are the following: the best-fit modulation amplitude for l {<=} 64 and the ILC data with the WMAP KQ85 sky cut is A = 0.072 {+-} 0.022, nonzero at 3.3{sigma}, and the preferred direction points toward Galactic coordinates (l, b) = (224 deg., - 22 deg.) {+-} 24 deg. The corresponding results for l {approx}< 40 from earlier analyses were A = 0.11 {+-} 0.04 and (l, b) = (225 deg. - 27 deg.). The statistical significance of a nonzero amplitude thus increases from 2.8{sigma} to 3.3{sigma} when increasing l{sub max} from 40 to 64, and all results are consistent to within 1{sigma}. Similarly, the Bayesian log-evidence difference with respect to the isotropic model increases from {delta}ln E = 1.8 to {delta}ln E = 2.6, ranking as 'strong evidence' on the Jeffreys' scale. The raw best-fit log-likelihood difference increases from {delta}ln L = 6.1 to {delta}ln L = 7.3. Similar, and often slightly stronger, results are found for other data combinations. Thus, we find that the evidence for a dipole power distribution in the WMAP data increases with l in the five-year WMAP data set, in agreement with the reports of Hansen et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward memory-efficient melt pool monitoring: a classification framework using event-based imaging and sparse sensing technique

Vision sensors like CMOS and CCD cameras are often used for in-process monitoring of melt pools in laser-based additive and welding processes, but they require transferring large amounts of data and computational processing resources. Event-based neuromorphic imagery, on the other hand, detects only the change in pixel intensity, thus potentially reducing the data amount and latency. With an event imager, this study develops a framework for melt pool condition classification, including image construction, time scale selection, optimal pixel selection, and sparse classification, to achieve a highly memory-efficient scheme. These are based on sparse sensing techniques with singular value decomposition (SVD) and QR pivoting, the two fundamental matrix transformations for linear dimensionality reduction. The framework is then validated by classifying a controlled experiment by exciting various mode shapes of liquid gallium pools of varying depths (3, 6, and 8 mm). At 200 pixels, the classifier can reach overall accuracy of 75%, while at 2000 pixels (0.013% of the total possible pixels), the accuracy is nearly 90% (89.86%). At the same number of pixels, random selection can only achieve 46% and 67%, respectively. The memory savings of the sparsely sampled event data compared to a conventional imager is about 500 times. In addition to performance, implementation and limitations of the framework are also discussed.

42 ENGINEERING↗

The GCT camera for the Cherenkov Telescope Array

The Gamma Cherenkov Telescope (GCT) is one of the designs presented for the Small Sized Telescope (SST) section of the Cherenkov Telescope Array (CTA). The GCT uses dual-mirror optics, resulting in a compact telescope with good image quality and a large field of view with a smaller, more economical, camera than is achievable with conventional single mirror solutions. The photon counting GCT camera is designed to record the flashes of atmospheric Cherenkov light from gamma and cosmic ray initiated cascades, which last only a few tens of nanoseconds. The GCT optics require that the camera detectors follow a convex surface with a radius of curvature of 1 m and a diameter of ~35 cm, which is approximated by tiling the focal plane with 32 modules. The initial camera prototype is equipped with multi-anode photomultipliers, each comprising an 8×8 array of 6×6 mm 2 pixels to provide the required angular scale, adding up to 2048 pixels in total. Detector signals are shaped, amplified and digitised by electronics based on custom ASICs that provide digitisation at 1 GSample/s. The camera is self-triggering, retaining images where the focal plane light distribution matches predefined spatial and temporal criteria. The electronics are housed in the liquid-cooled, sealed camera enclosure. LED flashers at the corners of the focal plane provide a calibration source via reflection from the secondary mirror. The first GCT camera prototype underwent preliminary laboratory tests last year. In November 2015, the camera was installed on a prototype GCT telescope (SST-GATE) in Paris and was further used to successfully record the first Cherenkov light of any CTA prototype, and the first Cherenkov light seen with such a dual-mirror optical system. A second full-camera prototype based on Silicon Photomultipliers is under construction. Up to 35 GCTs are envisaged for CTA.

47 OTHER INSTRUMENTATION↗

Digital pixel test structures implemented in a 65 nm CMOS process

The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20–40 µm and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article. The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at + 20 °C and a detection efficiency of 99% for a DPTS irradiated with a dose of 10 15 1 MeV n eq cm -2 . Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Energy Scale of the XRS on Astro-E2

The XRS on Astro-E2 consists of a microcalorimeter array with 31 active pixels. The XRS energy scale, which converts the measured pulse heights to the energies of the photons incident on the array, is a non-linear function of the thermal properties of the pixels and the power and noise conditions on the array. Each of the pixels operates independently and requires an individual energy scale. Analytic models of the XRS pulses are currently being developed that will be used to model the energy scale. However, because of the inherent complexity, a full empirical calibration of the energy scale is being conducted. The XRS energy scale has been calibrated for a range of operating conditions including variations in the detector temperature, bath temperatures, and photon flux. This allows us to characterize the functional dependence of the energy scale on these variables and to then generate a semi-empirical model that can be used to account for variations in operating conditions in space. We will present the results of the empirical characterization and comparisons to the analytic models.

Cottam, J.↗