Search NASA⌕ Search

SEARCH · Search NASA

Results for “polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

99 records · Page 6

Evaluation of the beam-induced depolarization of the HJET target at the EIC

The Polarized Atomic Hydrogen Gas Jet Target (HJET) has played a central role in the absolute calibration of proton beam polarization at RHIC and is foreseen as a key component of the hadron polarimetry program at the future Electron–Ion Collider (EIC). The substantially higher beam current, reduced bunch spacing, and shorter bunch length planned for EIC operation motivate a careful reassessment of possible beam-induced depolarization of the jet target. In this paper, the depolarization of ground-state hydrogen atoms caused by the time-dependent magnetic field of the circulating polarized proton beam is quantitatively evaluated. The hydrogen atom is treated as a four-level hyperfine system in a holding magnetic field, and transitions driven by harmonic components of the bunch-induced magnetic field are analyzed using time-dependent quantum-mechanical evolution along atomic trajectories. Numerical tracking of hydrogen atoms through the beam region is performed using nominal EIC beam parameters. It is shown that, for a holding field of 120 mT (as used at RHIC), the resulting depolarization of the jet target at the EIC is negligibly small, ≲ 0.01 %, and well below the level relevant for EIC polarization accuracy requirements. The stability of this result with respect to plausible variations of the EIC proton beam parameters is also evaluated. In addition, possible effects under alternative experimental conditions are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cubic crystals in an x-ray polarization-splitting geometry

Hexagonal and cubic crystals contain paired sets of internal planes that reflect the linearly polarized components of certain x rays into two separate, perpendicular directions. For the cubic crystals, two distinct crystal orientations provide the same polarization-splitting geometry. One of the orientations may have advantages for plasma spectroscopy by suppressing unwanted reflections. This paper demonstrates the two orientations with a germanium crystal and K characteristic lines from copper and zirconium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

Polarization splitting with cubic crystals evaluated with synchrotron radiation

X-ray polarization-splitting crystals separate incident x rays into two components with perpendicular polarization by Bragg reflections at 45° from paired sets of internal planes. Here, the polarization-splitting properties of a germanium crystal are verified using incompletely polarized synchrotron radiation. Further, cleaner data would have come from a beam with a higher degree of polarization, which is achievable with small changes in the experimental geometry.

47 OTHER INSTRUMENTATION↗

Single layer graphene protective layer on GaAs photocathodes for spin-polarized electron source

GaAs-based photocathodes are the primary choice for polarized electron sources, commonly used in polarized electron microscopes and polarized positron sources. GaAs photocathodes are typically activated with cesium and oxygen, which are highly reactive and require an ultra-high vacuum (⁠~ 10 -11 Torr or lower) to operate reliably, resulting in substantial operational difficulties. A short exposure to a mediocre vacuum results in an instantaneous loss of cathode quantum efficiency (QE) due to the chemical reaction of the active layer with residual gas molecules or back-bombardment ions during operation. Covering the GaAs cathode with a 2D material, such as monolayer graphene, could provide protection against such damage due to the inhibition of chemical reactions with residual gas molecules. In this paper, we have incorporated a method known as intercalation to pass the active material underneath the graphene and activate the superlattice GaAs/GaAsP (SL-GaAs) photocathode. X-ray photoelectron spectroscopy, low-energy electron microscopy, and Mott scattering measurements were performed to evaluate the formation of the photocathode under graphene, as well as its spectral response and electron spin polarization. Our results demonstrate that the successful activation of the SL-GaAs photocathode with a graphene protection layer is achieved with a moderate QE. Furthermore, we found that the electron spin polarization of the cathode with a surface protection layer is higher than the conventional cathode without a protection layer.

2D materials↗

Four-year Cosmology Large Angular Scale Surveyor (CLASS) Observations: On-sky Receiver Performance at 40, 90, 150, and 220 GHz Frequency Bands

The Cosmology Large Angular Scale Surveyor (CLASS) observes the polarized cosmic microwave background (CMB) over the angular scales of 1° ≲ θ ≤ 90° with the aim of characterizing primordial gravitational waves and cosmic reionization. We report on the on-sky performance of the CLASS Q-band (40 GHz), W-band (90 GHz), and dichroic G-band (150/220 GHz) receivers that have been operational at the CLASS site in the Atacama desert since 2016 June, 2018 May, and 2019 September, respectively. We show that the noise-equivalent power measured by the detectors matches the expected noise model based on on-sky optical loading and lab-measured detector parameters. Using Moon, Venus, and Jupiter observations, we obtain power to antenna temperature calibrations and optical efficiencies for the telescopes. From the CMB survey data, we compute instantaneous array noise-equivalent-temperature sensitivities of 22, 19, 23, and 71 $\mu {{\rm{K}}}_{\mathrm{cmb}}\sqrt{{\rm{s}}}$ for the 40, 90, 150, and 220 GHz frequency bands, respectively. These noise temperatures refer to white noise amplitudes, which contribute to sky maps at all angular scales. Future papers will assess additional noise sources impacting larger angular scales.

Observational cosmology↗

A Measurement of the Largest-scale CMB E -mode Polarization with CLASS

We present measurements of large-scale cosmic microwave background E-mode polarization from the Cosmology Large Angular Scale Surveyor 90 GHz data. Using 115 det-yr of observations collected through 2024 with a variable-delay polarization modulator, we achieved a polarization sensitivity of 82 μK arcimin, comparable to Planck at similar frequencies (100 and 143 GHz ). The analysis demonstrates effective mitigation of systematic errors and addresses challenges to large-angular-scale power recovery posed by time-domain filtering in maximum-likelihood map-making. A novel implementation of the pixel-space transfer matrix is introduced, which enables efficient filtering simulations and bias correction in the power spectrum using the quadratic cross-spectrum estimator. Overall, we achieved an unbiased time-domain filtering correction to recover the largest angular scale polarization, with the only power deficit, arising from map-making nonlinearity, being characterized as <3%. Through cross-correlation with Planck, we detected the cosmic reionization at 99.4% significance and measured the reionization optical depth τ = $0.053^{+0.018}_{-0.019}$, marking the first ground-based attempt at such a measurement. At intermediate angular scales (ℓ > 30), our results, both independently and in cross-correlation with Planck, remain fully consistent with Planck’s measurements.

79 ASTRONOMY AND ASTROPHYSICS↗