Search NASA⌕ Search

SEARCH · Search NASA

Results for “portable sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Loads Produced During the Ingression and Egression of the Portable Foot Restraint on the Hubble Space Telescope

The Hubble Space Telescope (HST) was deployed from the Space Shuttle Discovery on April 25, 1990. It is capable of performing observations in the visible, near-ultraviolet, and near-infrared (1150 A to 1 mm). The HST weighs 12 tons, and collects light with an 8-ft-diameter mirror. The attitude control and maneuvering is performed by four of six gyroscopes, or reaction wheels. The HST contains fine guidance sensors that lock onto guide stars to reduce the spacecraft drift and increase the pointing accuracy. The HST was designed to last 15 years, with crewed service missions approximately every three years. The first service mission, STS-61, took place in 1993. The second service mission took place in 1997. In 1999, the STS-103 crew performed the third service mission to the HST. This mission's purpose was to replace the right sensor units and make improvements on the fine guidance sensors. To perform these tasks on the HST, the STS-103 crewmembers used a portable foot restraint to anchor themselves to the HST in the zero-gravity environment. The solar arrays currently used on the telescope are second-generation, and therefore susceptible to loads placed on the telescope. The crew and Mission Operations Directorate worried about the damage that the crew could possibly cause during ingress and egress of the PFR and by transferring loads to the solar arrays. The purpose of this study is to inform the crewmembers of the loads they are imparting on the HST, and train them to decrease these loads to a safer level. Minimizing these loads will significantly decrease the chance of crewmembers causing damage to the solar arrays while repairing the HST.

Ramsey, Susan↗

Multisensor Instrument for Real-Time Biological Monitoring

The figure schematically depicts an instrumentation system, called a fiber optic-based integration system (FOBIS), that is undergoing development to enable real-time monitoring of fluid cell cultures, bioprocess flows, and the like. The FOBIS design combines a micro flow cytometer (MFC), a microphotometer (MP), and a fluorescence-spectrum- or binding-force-measuring micro-sensor (MS) in a single instrument that is capable of measuring multiple biological parameters simultaneously or sequentially. The fiber-optic-based integration system is so named because the MFC, the MP, and the MS are integrated into a single optical system that is coupled to light sources and photometric equipment via optical fibers. The optical coupling components also include a wavelength-division multiplexer and diffractive optical elements. The FOBIS includes a laserdiode- and fiber-optic-based optical trapping subsystem (optical tweezers ) with microphotometric and micro-sensing capabilities for noninvasive confinement and optical measurement of relevant parameters of a single cell or other particle. Some of the measurement techniques implemented together by the FOBIS have long been used separately to obtain basic understanding of the optical properties of individual cells and other organisms, the optical properties of populations of organisms, and the interrelationships among these properties, physiology of the organisms, and physical processes that govern the media that surround the organisms. For example, flow cytometry yields information on numerical concentrations, cross-sectional areas, and types of cells or other particles. Micro-sensing can be used to measure pH and concentrations of oxygen, carbon dioxide, glucose, metabolites, calcium, and antigens in a cell-culture fluid, thereby providing feedback that can be helpful in improving control over a bioprocess. Microphotometry (including measurements of scattering and fluorescence) can yield further information about optically trapped individual particles. In addition to the multifunctionality not previously available in a single biological monitoring system, the FOBIS offers advantages of low mass, sensitivity, accuracy, portability, low cost, compactness (the overall dimensions of the fully developed FOBIS sensor head are expected to be less than 1 by 1 by 2 cm), and immunity to electromagnetic interference at suboptical frequencies. FOBIS could be useful in a variety of laboratory and field settings in such diverse endeavors as medical, veterinary, and general biological research; medical and veterinary diagnosis monitoring of industrial bioprocesses; and analysis of biological contaminants in air, water, and food.

Zhang, Sean (Zhanxiang)↗

A study for hypergolic vapor sensor development

In summary, the following tasks were completed within the scope of this work: (1) a portable Monomethylhydrazine analyzer was developed, designed, fabricated and tested. (2) A portable NO2 analyzer was developed, designed, fabricated and tested. (3) Sampling probes and accessories were designed and fabricated for this instrumentation. (4) Improvements and modifications were made to the model 7630 Ecolyzer in preparation for field testing. (5) Instrument calibration procedures and hydrazine handling techniques necessary to the successful application of this hardware were developed.

Stetter, J. R.↗

NASA Tech Briefs, January 2007

Topics covered include: Flexible Skins Containing Integrated Sensors and Circuitry; Artificial Hair Cells for Sensing Flows; Video Guidance Sensor and Time-of-Flight Rangefinder; Optical Beam-Shear Sensors; Multiple-Agent Air/Ground Autonomous Exploration Systems; A 640 512-Pixel Portable Long-Wavelength Infrared Camera; An Array of Optical Receivers for Deep-Space Communications; Microstrip Antenna Arrays on Multilayer LCP Substrates; Applications for Subvocal Speech; Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply; The PICWidget; Fusing Symbolic and Numerical Diagnostic Computations; Probabilistic Reasoning for Robustness in Automated Planning; Short-Term Forecasting of Radiation Belt and Ring Current; JMS Proxy and C/C++ Client SDK; XML Flight/Ground Data Dictionary Management; Cross-Compiler for Modeling Space-Flight Systems; Composite Elastic Skins for Shape-Changing Structures; Glass/Ceramic Composites for Sealing Solid Oxide Fuel Cells; Aligning Optical Fibers by Means of Actuated MEMS Wedges; Manufacturing Large Membrane Mirrors at Low Cost; Double-Vacuum-Bag Process for Making Resin- Matrix Composites; Surface Bacterial-Spore Assay Using Tb3+/DPA Luminescence; Simplified Microarray Technique for Identifying mRNA in Rare Samples; High-Resolution, Wide-Field-of-View Scanning Telescope; Multispectral Imager With Improved Filter Wheel and Optics; Integral Radiator and Storage Tank; Compensation for Phase Anisotropy of a Metal Reflector; Optical Characterization of Molecular Contaminant Films; Integrated Hardware and Software for No-Loss Computing; Decision-Tree Formulation With Order-1 Lateral Execution; GIS Methodology for Planning Planetary-Rover Operations; Optimal Calibration of the Spitzer Space Telescope; Automated Detection of Events of Scientific Interest; Representation-Independent Iteration of Sparse Data Arrays; Mission Operations of the Mars Exploration Rovers; and More About Software for No-Loss Computing.

Source record↗

A Portable, High Resolution, Surface Measurement Device

A high resolution, portable, surface measurement device has been demonstrated to provide micron-resolution topographical plots. This device was specifically developed to allow in-situ measurements of defects on the Space Shuttle Orbiter windows, but is versatile enough to be used on a wide variety of surfaces. This paper discusses the choice of an optical sensor and then the decisions required to convert a lab bench optical measurement device into an ergonomic portable system. The necessary trade-offs between performance and portability are presented along with a description of the device developed to measure Orbiter window defects.

Ihlefeld, Curtis M.↗

Techniques for measuring intercepted and absorbed PAR in corn canopies

The quantity of radiation potentially available for photosynthesis that is captured by the crop is best described as absorbed photosynthetically active radiation (PAR). Absorbed PAR (APAR) is the difference between descending and ascending fluxes. The four components of APAR were measured above and within two planting densities of corn (Zea mays L.) and several methods of measuring and estimating APAR were examined. A line quantum sensor that spatially averages the photosynthetic photon flux density provided a rapid and portable method of measuring APAR. PAR reflectance from the soil (Typic Argiaquoll) surface decreased from 10% to less than 1% of the incoming PAR as the canopy cover increased. PAR reflectance from the canopy decreased to less than 3% at maximum vegetative cover. Intercepted PAR (1 - transmitted PAR) generally overestimated absorbed PAR by less than 4% throughout most of the growing season. Thus intercepted PAR appears to be a reasonable estimate of absorbed PAR.

Gallo, K. P.↗

The SeaWiFS Quality Monitor: A Portable Field Calibration Light Source

A portable and stable source, the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Quality Monitor, has been developed for use as a field instrument. The source can be used with either radiance- or irradiance-measuring sensors to transfer the laboratory calibration to the field so that the stability of the sensors can be monitored during the experiment. Temperature-controlled silicon photodiodes with colored glass filters are used to monitor the stability of the SeaWiFS Quality Monitor.

Shaw, Ping-Shine↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

UAS Payload Design for In-Situ Smoke Plume Sensing

To aid in the detection of harmful aerosols and trace gases emitted in wildfires and prescribed burns, we are designing a smoke-specific payload which can be flown on the Black Swift S2™ Uncrewed Aerial System (UAS) platform. The payload will be custom and mounted within the nosecone, equipped with a trace gas sensor suite and particle spectrometer for characterization of wildfire and prescribed burn emissions. This data will aid in the improvement of HYSPLIT3 modeling to make more informed decisions regarding prescribed burns, particularly for mountain valleys in the Pacific Northwest. The trace gas suite will be composed of 8 low-cost trace gas sensors (CH4, CO2, CO, HCN, NO2, NO, O3, and Volatile Organic Compounds (VOCs)). Portable Optical Particle Spectrometer (POPS) measures particle size range between 0.14 to 3 µm, which is crucial for assessing public health impact, air quality, and visibility.

Henry Miller↗

Optical Breath Gas Sensor for Extravehicular Activity Application

The function of the infrared gas transducer used during extravehicular activity in the current space suit is to measure and report the concentration of carbon dioxide (CO2) in the ventilation loop. The next generation portable life support system (PLSS) requires next generation CO2 sensing technology with performance beyond that presently in use on the Space Shuttle/International Space Station extravehicular mobility unit (EMU). Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. A laser diode spectrometer based on wavelength modulation spectroscopy is being developed for this purpose by Vista Photonics, Inc. Two prototype devices were delivered to NASA Johnson Space Center (JSC) in September 2011. The sensors incorporate a laser diode-based CO2 channel that also includes an incidental water vapor (humidity) measurement and a separate oxygen channel using a vertical cavity surface emitting laser. Both prototypes are controlled digitally with a field-programmable gate array/microcontroller architecture. The present development extends and upgrades the earlier hardware to the Advanced PLSS 2.0 test article being constructed and tested at JSC. Various improvements to the electronics and gas sampling are being advanced by this project. The combination of low power electronics with the performance of a long wavelength laser spectrometer enables multi-gas sensors with significantly increased performance over that presently offered in the EMU.

Wood, William R.↗

Optical Breath Gas Sensor for Extravehicular Activity Application

The function of the infrared gas transducer used during extravehicular activity (EVA) in the current space suit is to measure and report the concentration of carbon dioxide (CO2) in the ventilation loop. The next generation Portable Life Support System (PLSS) requires next generation CO2 sensing technology with performance beyond that presently in use on the Shuttle/International Space Station extravehicular mobility unit (EMU). Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. A laser diode (LD) spectrometer based on wavelength modulation spectroscopy (WMS) is being developed for this purpose by Vista Photonics, Inc. Two prototype devices were delivered to NASA Johnson Space Center (JSC) in September 2011. The sensors incorporate a laser diode based CO2 channel that also includes an incidental water vapor (humidity) measurement and a separate oxygen (O2) channel using a vertical cavity surface emitting laser (VCSEL). Both prototypes are controlled digitally with a field-programmable gate array (FPGA)/microcontroller architecture. Based on the results of the initial instrument development, further prototype development and testing of instruments leveraging the lessons learned were desired. The present development extends and upgrades the earlier hardware to the Advanced PLSS 2.0 test article being constructed and tested at JSC. Various improvements to the electronics and gas sampling are being advanced by this project. The combination of low power electronics with the performance of a long wavelength laser spectrometer enables multi-gas sensors with significantly increased performance over that presently offered in the EMU. .

Wood, William R.↗

The Joint Airport Weather Studies Project - Current analysis highlights in the aviation safety context

The principal objective of the Joint Airport Weather Studies Project was to obtain high-resolution velocity, turbulence, and thermodynamic data on a convective outflow called a microburst, an intense downdraft and resulting horizontal outflow near the surface. Data collection occurred during the summer of 1982 near Denver, CO. Data sensors included three pulsed-microwave Doppler and two pulsed CO2 lidar radars, along with 27 Portable Automated Mesonet surface weather stations, the FAA's low-level-wind-shear alert system (LLWSAS), and five instrumented research aircraft. Convective storms occurred on 75 of 91 operational days, with Doppler data being collected on at least 70 microbursts. Analyses reported included a thorough examination of microburst-climatology statistics, the capability of the LLWSAS to detect adequately and accurately the presence of low-altitude wind shear danger to aircraft, the capability of a terminal Doppler radar system development to provide improved wind-shear detection and warning, and progress toward improved wind-shear training for pilots.

Mccarthy, J.↗

Medical and surgical applications of space biosensor technology

Researchers in space life sciences are rapidly approaching a technology impasse. Many of the critical questions on the impact of spaceflight on living systems simply cannot be answered with the limited available technologies. Research subjects, particularly small animal models like the rat, must be allowed to function relatively untended and unrestrained for long periods to fully reflect the impact of microgravity and spaceflight on their behavior and physiology. These requirements preclude the use of present hard-wired instrumentation techniques and limited data acquisition systems. Implantable sensors and miniaturized biotelemetry are the only means of capturing the fundamental and critical data. This same biosensor and biotelemetry technology has direct application to Earth-based medicine and surgery. Continuous, on-line data acquisition and improved measurement capabilities combined with the ease and flexibility offered by automated, wireless, and portable instruments and data systems, should provide a boon to the health care industry. Playing a key role in this technology revolution is the Sensors 2000! (S2K!) Program at NASA Ames Research Center. S2K!, in collaboration with space life sciences researchers and managers, provides an integrated capability for sensor technology development and applications, including advanced biosensor technology development, spaceflight hardware development, and technology transfer and commercialization. S2K! is presently collaborating on several spaceflight projects with dual-use medical applications. One prime example is a collaboration with the Fetal Treatment Center (FTC) at the University of California at San Francisco. The goal is to develop and apply implantable chemical sensor and biotelemetry technology to continuously monitor fetal patients during extra-uterine surgery, replacement into the womb, through birth and beyond. Once validated for ground use, the method will be transitioned to spaceflight applications to remotely monitor key biochemical parameters in flight animals. Successful application of NASA implantable biosensor and biotelemetry technologies should accelerate the advancement of this and other modern medical procedures while furthering the exploration of life in space.

NASA Discipline General Space Life Sciences↗

A Portable Electronic Nose For Hydrazine and Monomethyl Hydrazine Detection

The Space Program and military use large quantities Hydrazine (Hz) and monomethyl hydrazine (MMI-I) as rocket propellant. These substances are very toxic and are suspected human carcinogens. The American Conference of Governmental Industrial Hygienist set the threshold limit value to be 10 parts per billion (ppb). Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect 10 ppb concentration. This shortcofriing is not acceptable for many operations. A new prototype instrument using a gas sensor array and pattern recognition software technology (i.e., an electronic nose) has demonstrated the ability to identify either Hz or MM}{ and quantify their concentrations at 10 parts per billion in 90 seconds. This paper describes the design of the portable electronic nose (e-nose) instrument, test equipment setup, test protocol, pattern recognition algorithm, concentration estimation method, and laboratory test results.

Young, Rebecca C.↗

The effect of sensor sheltering and averaging techniques on wind measurements at the Shuttle Landing Facility

This document presents results of a field study of the effect of sheltering of wind sensors by nearby foliage on the validity of wind measurements at the Space Shuttle Landing Facility (SLF). Standard measurements are made at one second intervals from 30-feet (9.1-m) towers located 500 feet (152 m) from the SLF centerline. The centerline winds are not exactly the same as those measured by the towers. A companion study, Merceret (1995), quantifies the differences as a function of statistics of the observed winds and distance between the measurements and points of interest. This work examines the effect of nearby foliage on the accuracy of the measurements made by any one sensor, and the effects of averaging on interpretation of the measurements. The field program used logarithmically spaced portable wind towers to measure wind speed and direction over a range of conditions as a function of distance from the obstructing foliage. Appropriate statistics were computed. The results suggest that accurate measurements require foliage be cut back to OFCM standards. Analysis of averaging techniques showed that there is no significant difference between vector and scalar averages. Longer averaging periods reduce measurement error but do not otherwise change the measurement in reasonably steady flow regimes. In rapidly changing conditions, shorter averaging periods may be required to capture trends.

Merceret, Francis J.↗