Search NASA⌕ Search

SEARCH · Search NASA

Results for “power distribution faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

This presentation starts with the details of IEEE 2800-2022 requirements of IBR for balanced and unbalanced faults. Then, it shows how to design a droop based GFM control to be IEEE 2800-2022 compliant. An performance evaluation is carried out to see if three OEM GFM inverters 2800-2022 compliant or not. And finally we show how IEEE 2800-2022 complaint and non-compliant GFM inverter will impact the transmission line protection elements, such as directional element and FID. Finally, recommendations are made if the GFM is not IEEE 2800-2022 compliant to disable the protection elements that rely on reliable and regulated negative sequence current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A PSCAD Library Component Featuring a Reduced-Order IBR Model for EMT-Based Fault Studies

This paper presents a fully implemented inverter reduce-order-model (ROM) in an EMT simulation (PSCAD) library component for direct user utilization in protection studies. The developed inverter ROM has the following features: Equivalent to a full IBR inverter model with positive- and negative-sequence current formulation and representation A python script is developed to fully automate this process, including training data generation, ROM parameter training, updating parameters, and model verification and validation. With this PSCAD ROM library component, protection engineers can utilize a trustworthy, accurate ROM for protection studies in an easy-to-use and streamlined manner.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing a decentralized fault-tolerant software framework for smart grids and its applications

The vision of the ‘Smart Grid’ anticipates a distributed real-time embedded system that implements various monitoring and control functions. As the reliability of the power grid is critical to modern society, the software supporting the grid must support fault tolerance and resilience of the resulting cyber-physical system. This paper describes the fault-tolerance features of a software framework called Resilient Information Architecture Platform for Smart Grid (RIAPS). The framework supports various mechanisms for fault detection and mitigation and works in concert with the applications that implement the grid-specific functions. The paper discusses the design philosophy for and the implementation of the fault tolerance features and presents an application example to show how it can be used to build highly resilient systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Graph-Learning-Assisted State and Event Tracking for Solar-Penetrated Power Grids with Heterogeneous Data Sources

Unlike transmission systems, distribution systems do not typically contain sufficient metering to enable real-time state estimation. The lack of sufficient real-time measurements prohibits accurate and timely monitoring of the state of distribution systems. As a result, control and optimal operation of distribution systems, especially those containing large numbers of renewable generation units are not possible without proper data and information about the current state of the system. The main motivation of this project is to address this shortcoming by developing an approach which provides “predicted” real-time measurements so that they can be used to execute a distribution system state estimator. Thus, the objective of the project is to make the distribution systems fully observable, such that the hosting capacity for solar generation can be accurately estimated, and unnecessary solar curtailments can be avoided. In order to accomplish this goal, the project investigated the use of a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams obtained from AMI meters, SCADA as well as PMU measurements and created synchronous measurement snapshots for the state estimator (SE); and developed a hybrid robust SE which provides not only accurate state estimates but also real-time feedback for the ML model refinement.

14 SOLAR ENERGY↗

Parameter Reduction of Composite Load Model Using Active Subspace Method

Over the past decades, the increasing penetration of distributed energy resources (DERs) has dramatically changed the power load composition in the distribution networks. The traditional static and dynamic load models can hardly capture the dynamic behavior of modern loads especially for fault-induced delayed voltage recovery (FIDVR) events. Thus, a more comprehensive composite load model with combination of static load, different types of induction motors, single-phase A/C motor, electronic load and DERs has been proposed by Western Electricity Coordinating Council (WECC). However, due to the large number of parameters and model complexity, the WECC composite load model (WECC CMLD) raises new challenges to power system studies. To overcome these challenges, in this paper, a cutting-edge parameter reduction (PR) approach for WECC CMLD based on active subspace method (ASM) is proposed. Firstly, the WECC CMLD is parameterized in a discrete-time manner for the application of the proposed method. Then, parameter sensitivities are calculated by discovering the active subspace, which is a lower-dimensional linear subspace of the parameter space of WECC CMLD in which the dynamic response is most sensitive. The interdependency among parameters can be taken into consideration by our approach. Finally, the numerical experiments validate the effectiveness and advantages of the proposed approach for WECC CMLD model.

active subspace↗

Ensemble models for circuit topology estimation, fault detection and classification in distribution systems

This paper presents a methodology for simultaneous fault detection, classification, and topology estimation for adaptive protection of distribution systems. The methodology estimates the probability of the occurrence of each one of these events by using a hybrid structure that combines three sub-systems, a convolutional neural network for topology estimation, a fault detection based on predictive residual analysis, and a standard support vector machine with probabilistic output for fault classification. The input to all these sub-systems is the local voltage and current measurements. A convolutional neural network uses these local measurements in the form of sequential data to extract features and estimate the topology conditions. The fault detector is constructed with a Bayesian stage (a multitask Gaussian process) that computes a predictive distribution (assumed to be Gaussian) of the residuals using the input. Since the distribution is known, these residuals can be transformed into a Standard distribution, whose values are then introduced into a one-class support vector machine. The structure allows using a one-class support vector machine without parameter cross-validation, so the fault detector is fully unsupervised. Finally, a support vector machine uses the input to perform the classification of the fault types. All three sub-systems can work in a parallel setup for both performance and computation efficiency. In conclusion, we test all three sub-systems included in the structure on a modified IEEE123 bus system, and we compare and evaluate the results with standard approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Validating Protection System Behavior with Machine Learning in a Master State Overseer

As power system protection devices continue the widespread transition from analog to digital, they become increasingly intricate. The internal functions and communication between critical grid components must now be significantly more complex to keep up with the demands of the modern smart grid. This brings increased difficulty in maintenance and monitoring, making it harder to identify potential misoperation, power anomalies, and cyber threats. Such issues are often only pinpointed after an exhaustive and costly post-mortem analysis, when a major outage or damage has already occurred. A solution is needed for validating protection systems as they operate, independently evaluating grid state and confirming whether the protection system is behaving accordingly. As opposed to incident response, this acts as a constant verification mechanism that raises a flag when subtler issues are noticed, catching them earlier and preventing larger incidents. This work presents the implementation of such a system, expanding on the prototype developed by the authors in a previous paper. This is accomplished with a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. Additionally, this system is contextualized within a larger, modular Master State awareness Overseer (MSO) framework, responsible for monitoring, analyzing, and managing an electric grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Adaptive Fault Detection Based on Neural Networks and Multiple Sampling Points for Distribution Networks and Microgrids

Smart networks such as microgrid (MG) and active distribution networks (ADN) have been recently playing an important role in power system operation. The design and implementation of appropriate protection systems for such networks must be addressed, which imposes new technical challenges. This paper presents the implementation and validation aspects of an adaptive fault detection strategy based on neural networks (NNs) and multiple sampling points for ADN and MG. The solution is implemented on an edge device. Artificial NNs are used to derive a data-driven model that uses only local measurements to detect fault states of the network without the need for communication infrastructure. Multiple sampling points are used to derive a data-driven model, which allows the generalization considering the implementation in physical systems. The adaptive fault detector model is implemented on a Jetson Nano system, which is a single-board computer (SBC) with a small Graphic Processing Unit (GPU) intended to run machine learning loads at the edge. The proposed method is tested in a physical, real-life, low-voltage network located at Universidad del Norte, Colombia. This testing network is based on the IEEE-13 Node Test Feeder scaled down to 220 V. The validation in a simulation environment shows the accuracy and dependability above 99.6%, while the real-time tests show the accuracy and dependability of 95.5% and 100%, respectively. Without hard-to-derive parameters, the easy-to-implement embedded model highlights the potential for real-life applications.

42 ENGINEERING↗

De-Energized Line Testing Interface (DELTI) Report

To guarantee the safety of power system operations, it is crucial to understand a de-energized power line’s status before restoring power. It is hypothesized that the Grid Resonance Probe (GRP) and De-Energized Line Testing Interface (DELTI) can be utilized to identify a faulted distribution line. Therefore, the project team is targeting development of a methodology to identify faulted distribution lines by using the DELTI system. In this R&D task, two field tests on Plum Island have been conducted, including DELTI tests with multiple configurations and fault scenarios. This report provides the analysis results of distribution line fault identification from the two field tests. In the remainder of this report, Section 1 is the introduction of the DELTI system, Section 2 provides the analyses of the two field tests in June and October of 2021, respectively, Section 3 discusses the existing line fault detection devices on market and how they compare to DELTI and Section 4 includes the lessons learned and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability Barriers to Enhanced Solar PV Deployment: Selected Research Findings - State Outreach Technical Sessions

This presentation provides summaries of three reports selected from a body of work that examines potential reliability challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations in the western United States. The three topics covered are 1) Power system flexibility requirements and supply; 2) Resource adequacy and the capacity credit of solar; 3) Simulating distributed energy resource responses to transmission system-level faults considering IEEE 1547 performance categories on three major WECC transmission paths. The full reports and related resources are available at the project website, https://www.westernenergyboard.org/western-interstate-energy-board/barrier-mitigation-to-enhanced-distributed-solar-photovoltaic/. This presentation is targeted toward a technical audience. A companion policy presentation provides higher-level summaries of the same material.

distributed energy resource↗

Reliability Barriers to Enhanced Solar PV Deployment: Selected Research Findings - State Outreach Policy Sessions

This presentation provides high-level summaries of three reports selected from a body of work that examines potential reliability challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations in the western United States. The three topics covered are 1) Power system flexibility requirements and supply; 2) Resource adequacy and the capacity credit of solar; 3) Simulating distributed energy resource responses to transmission system-level faults considering IEEE 1547 performance categories on three major WECC transmission paths. The full reports and related resources are available at the project website, https://www.westernenergyboard.org/western-interstate-energy-board/barrier-mitigation-to-enhanced-distributed-solar-photovoltaic/. This presentation is targeted toward policy decision makers. A companion technical presentation provides more in-depth summaries of the same material.

distributed energy resource↗

1-D Convolutional Graph Convolutional Networks for Fault Detection in Distributed Energy Systems

This paper presents a 1-D convolutional and graph convolutional networks for fault detection in microgrids. The combination of 1-D convolutional neural networks (1D-CNN) and graph convolutional networks (GCN) helps extract both spatial-temporal correlations from the voltage measurements in microgrids. The fault detection scheme includes fault event detection, fault type and phase classification, and fault location. There are five neural network model training to handle these tasks. Transfer learning and fine-tuning are applied to reduce training efforts. The combined 1-D convolutional and graph convolutional networks (1D-CGCN) is compared with the traditional ANN structure on the Potsdam 13-bus microgrid dataset. The accuracy of 99.5%, 98.4%, 99.2%, and 95.5% are achieved in fault event detection, fault type classification, fault phase identification, and fault location respectively. The detailed confusion matrices of fault type and fault phase classification are provided for validation.

deep neural network↗

Performance and power modeling and prediction using MuMMI and 10 machine learning methods

Energy-efficient scientific applications require insight into how high performance computing system features impact the applications' power and performance. This insight can result from the development of performance and power models. Here, in this article, we use the modeling and prediction tool MuMMI (Multiple Metrics Modeling Infrastructure) and 10 machine learning methods to model and predict performance and power consumption and compare their prediction error rates. We use an algorithm-based fault-tolerant linear algebra code and a multilevel checkpointing fault-tolerant heat distribution code to conduct our modeling and prediction study on the Cray XC40 Theta and IBM BG/Q Mira at Argonne National Laboratory and the Intel Haswell cluster Shepard at Sandia National Laboratories. Our experimental results show that the prediction error rates in performance and power using MuMMI are less than 10% for most cases. By utilizing the models for runtime, node power, CPU power, and memory power, we identify the most significant performance counters for potential application optimizations, and we predict theoretical outcomes of the optimizations. Based on two collected datasets, we analyze and compare the prediction accuracy in performance and power consumption using MuMMI and 10 machine learning methods.

97 MATHEMATICS AND COMPUTING↗

A Power-Hardware-in-the-Loop (PHIL) Evaluation of Service Restoration With Networked Microgrids

This paper describes the power-hardware-in-the- loop (PHIL) evaluation of the feasibility of service restoration solutions determined by the PowerModelsONM.jl tool. This tool incorporates microgrids and the networking of microgrids into its determination of an optimal service restoration solution. The paper presents PHIL simulation results for a case study based on a real distribution feeder with multiple microgrids, showcas- ing the effectiveness of networked microgrids in aiding system restoration after an outage. The study leverages high-fidelity, real- time electromagnetic transient models to ensure accuracy in the simulation results. This work is the final output from the Resilient Operation of Networked Microgrids (RONM) project funded by the U.S. Department of Energy Office of Electricity Microgrid Program and led by Los Alamos National Laboratory. RONM focused on the application of PowerModelsONM.jl to enhance the resilience of distribution systems.

fault location isolation and service restoration (↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults: Preprint

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable bulk integration of renewable sources into the future power grid. However, the performance of GFM inverters during unbalanced faults remains under-explored. In this paper, a novel current-limiting method is proposed for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built-up in the stationary reference frame to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗