Search NASA⌕ Search

SEARCH · Search NASA

Results for “power factor correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A simple method for estimating minimum autorotative descent rate of single rotor helicopters

Flight test results of minimum autorotative descent rate are compared with calculations based on the minimum power required for steady level flight. Empirical correction factors are derived that account for differences in energy dissipation between these two flight conditions. A method is also presented for estimating the minimum power coefficient for level flight for any helicopter for use in the empirical estimation procedure of autorotative descent rate.

Talbot, P. D.↗

A subleading operator basis and matching for gg → H

The Soft Collinear Effective Theory (SCET) is a powerful framework for studying factorization of amplitudes and cross sections in QCD. While factorization at leading power has been well studied, much less is known at subleading powers in the λ << 1 expansion. In SCET subleading soft and collinear corrections to a hard scattering process are described by power suppressed operators, which must be fixed case by case, and by well established power suppressed Lagrangians, which correct the leading power dynamics of soft and collinear radiation. Here we present a complete basis of power suppressed operators for gg → H, classifying all operators which contribute to the cross section at O(λ 2 ), and showing how helicity selection rules significantly simplify the construction of the operator basis. We perform matching calculations to determine the tree level Wilson coefficients of our operators. These results are useful for studies of power corrections in both resummed and fixed order perturbation theory, and for understanding the factorization properties of gauge theory amplitudes and cross sections at subleading power. As one example, our basis of operators can be used to analytically compute power corrections for N -jettiness subtractions for gg induced color singlet production at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-73: Experimental Determination of the Effective Point of Measurement in Electron Beams Using a Commercial Scintillation Detector

Purpose: The aim of this work was to determine experimentally the effective point of measurement (EPOM) in clinical electron beams for three cylindrical ionization chambers using a commercial scintillation detector as a reference detector. Methods: Percent depth dose (PDD) curves were measured using an Exradin W1 scintillation detector and were used as a representative PDD to water. Depth dose curves were measured with the Exradin A18, A1SL, and A28 ionization chambers. The raw ionization chamber curve data were corrected by the chamber fluence perturbation correction factor and restricted mass collisional stopping power ratio at each depth to obtain a percent depth dose curve to the gas volume (PDDGV) of the detector. Ratios of the W1 PDD to the ion chamber PDDGV were calculated for each measurement depth. The W1 PDD curve was shifted by small depth increments, Δz, until the ratio of the W1 PDD to the ion chamber PDDGV was depth-independent (optimal Δz). A MATLAB routine was developed to determine the optimal Δz value. Results: The optimal Δz shift was used as an estimate of the EPOM for each chamber. The average calculated EPOM shifts (expressed as a fraction of the chamber cavity radius) for the A18, A1SL, and A28 ionization chambers were 0.21 ± 0.04, 0.10 ± 0.05, and 0.22 ± 0.03, respectively. Conclusion: The experimentally determined EPOM values for the A18 and A1SL in this work agreed with the simulated values of Muir and Rogers (MedPhys 2014). The results also indicate that the Exradin W1 scintillator is water equivalent for electron energies of 6 MeV, 9 MeV, 12 MeV, and 16 MeV. In addition, we confirmed that the AAPM TG51 recommended EPOM shift of 0.5 times the cavity radius is not accurate for the A18 and A1SL chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of ambient temperature and humidity on emissions of an idling gas turbine

The effects of inlet pressure, temperature, and humidity on the oxides of nitrogen produced by an engine operating at takeoff power setting were investigated and numerous correction factors were formulated. The effect of ambient relative humidity on gas turbine idle emissions was ascertained. Experimentally, a nonvitiating combustor rig was employed to simulate changing combustor inlet conditions as generated by changing ambient conditions. Emissions measurements were made at the combustor exit. For carbon monoxide, a reaction kinetic scheme was applied within each zone of the combustor where initial species concentrations reflected not only local combustor characteristics but also changing ambient conditions.

Kauffman, C. W.↗

Exclusive production of a pair of high transverse momentum photons in pion-nucleon collisions for extracting generalized parton distributions

We show that exclusive production of a pair of high transverse momentum photons in pion-nucleon collisions can be systematically studied in QCD factorization approach if the photon’s transverse momentum q T with respect to the colliding pion is much greater than Λ QCD . We demonstrate that the leading power non-perturbative contributions to the scattering amplitudes of this exclusive process are process-independent and can be systematically factorized into universal pion’s distribution amplitudes (DAs) and nucleon’s generalized parton distributions (GPDs), which are convoluted with corresponding infrared safe and perturbatively calculable short-distance hard parts. The correction to this factorized expression is suppressed by powers of 1/q T . We demonstrate quantitatively that this new type of exclusive processes is not only complementary to existing processes for extracting GPDs, but also capable of providing an enhanced sensitivity to the dependence of both DAs and GPDs on the active parton’s momentum fraction x. We also introduce additional, but the same type of exclusive observables to enhance our capability to explore GPDs, in particular, their x-dependence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A subleading power operator basis for the scalar quark current

Factorization theorems play a crucial role in our understanding of the strong interaction. For collider processes they are typically formulated at leading power and much less is known about power corrections in the λ << 1 expansion. Here we present a complete basis of power suppressed operators for a scalar quark current at O(λ 2 ) in the amplitude level power expansion in the Soft Collinear Effective Theory, demonstrating that helicity selection rules significantly simplify the construction. This basis applies for the production of any color singlet scalar in qq¯¯ annihilation (such as bb¯¯→H ). We also classify all operators which contribute to the cross section at O(λ 2 ) and perform matching calculations to determine their tree level Wilson coefficients. Furthermore, these results can be exploited to study power corrections in both resummed and fixed order perturbation theory, and for analyzing the factorization properties of gauge theory amplitudes and cross sections at subleading power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo calculations for reference dosimetry of electron beams with the PTW Roos and NE2571 ion chambers

Purpose: To investigate recommendations for reference dosimetry of electron beams and gradient effects for the NE2571 chamber and to provide beam quality conversion factors using Monte Carlo simulations of the PTW Roos and NE2571 ion chambers. Methods: The EGSnrc code system is used to calculate the absorbed dose-to-water and the dose to the gas in fully modeled ion chambers as a function of depth in water. Electron beams are modeled using realistic accelerator simulations as well as beams modeled as collimated point sources from realistic electron beam spectra or monoenergetic electrons. Beam quality conversion factors are calculated with ratios of the doses to water and to the air in the ion chamber in electron beams and a cobalt-60 reference field. The overall ion chamber correction factor is studied using calculations of water-to-air stopping power ratios. Results: The use of an effective point of measurement shift of 1.55 mm from the front face of the PTW Roos chamber, which places the point of measurement inside the chamber cavity, minimizes the difference betweenR{sub 50}, the beam quality specifier, calculated from chamber simulations compared to that obtained using depth-dose calculations in water. A similar shift minimizes the variation of the overall ion chamber correction factor with depth to the practical range and reduces the root-mean-square deviation of a fit to calculated beam quality conversion factors at the reference depth as a function of R{sub 50}. Similarly, an upstream shift of 0.34 r{sub cav} allows a more accurate determination of R{sub 50} from NE2571 chamber calculations and reduces the variation of the overall ion chamber correction factor with depth. The determination of the gradient correction using a shift of 0.22 r{sub cav} optimizes the root-mean-square deviation of a fit to calculated beam quality conversion factors if all beams investigated are considered. However, if only clinical beams are considered, a good fit to results for beam quality conversion factors is obtained without explicitly correcting for gradient effects. The inadequacy of R{sub 50} to uniquely specify beam quality for the accurate selection of k{sub Q} factors is discussed. Systematic uncertainties in beam quality conversion factors are analyzed for the NE2571 chamber and amount to between 0.4% and 1.2% depending on assumptions used. Conclusions: The calculated beam quality conversion factors for the PTW Roos chamber obtained here are in good agreement with literature data. These results characterize the use of an NE2571 ion chamber for reference dosimetry of electron beams even in low-energy beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilization of independent solar flux measurements to eliminate nongeochemical variation in X-ray fluorescence data

It is shown that the direct method of solar activity correction for lunar XRF data produces XRF data with better statistics than uncorrected data. Direct measurements of the solar flux made by Solrad 10 are converted to emissions of the sun from two assumed temperature regions. These emissions are ratioed to produce emission measure ratios, sensitive indicators of shifts in solar activity. The Tucker-Koren model (1971) of the solar flux is used in the calculation of EMRs and in the calculation of theoretical lunar Si, Al, and Mg fluorescence of maria and highland soils. Al/Si(Mg/Si) ratios calculated at a 'normal' EMR of 0.030 are divided by Al/Si(Mg/Si) ratios at particular EMRs. The relationship between EMR and the quotients of this division, called 'correction factors', is well explained by empirically derived power law functions.

Clark, P. E.↗

Ab initio electroweak corrections to superallowed β decays and their impact on V ud

Radiative corrections are essential for an accurate determination of V ud from superallowed β decays. In view of recent progress in the single-nucleon sector, the uncertainty is dominated by the theoretical description of nucleus-dependent effects, limiting the precision that can currently be achieved for V ud . In this work, we provide a detailed account of the electroweak corrections to superallowed β decays in effective field theory (EFT), including the power counting, potential and ultrasoft contributions, and factorization in the decay rate. Here, we present a first numerical evaluation of the dominant corrections in light nuclei based on quantum Monte Carlo methods, confirming the expectations from the EFT power counting. Finally, we discuss strategies how to extract from data the low-energy constants that parametrize short-distance contributions and whose values are not predicted by the EFT. Combined with advances in ab initio nuclear-structure calculations, this EFT framework allows one to systematically address the dominant uncertainty in V ud , as illustrated in detail for the 14 O → 14 N transition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NuSTAR unveils a Compton-thick type 2 quasar in MrK 34

We present Nuclear Spectroscopic Telescope Array (NuSTAR) 3-40 keV observations of the optically selected Type 2 quasar (QSO2) SDSS J1034+6001 or Mrk 34. The high-quality hard X-ray spectrum and archival XMM-Newton data can be fitted self-consistently with a reflection-dominated continuum and a strong Fe Kα fluorescence line with equivalent width >1 keV. Prior X-ray spectral fitting below 10 keV showed the source to be consistent with being obscured by Compton-thin column densities of gas along the line of sight, despite evidence for much higher columns from multiwavelength data. NuSTAR now enables a direct measurement of this column and shows that N {sub H} lies in the Compton-thick (CT) regime. The new data also show a high intrinsic 2-10 keV luminosity of L {sub 2-10} ∼ 10{sup 44} erg s{sup –1}, in contrast to previous low-energy X-ray measurements where L {sub 2-10} ≲ 10{sup 43} erg s{sup –1} (i.e., X-ray selection below 10 keV does not pick up this source as an intrinsically luminous obscured quasar). Both the obscuring column and the intrinsic power are about an order of magnitude (or more) larger than inferred from pre-NuSTAR X-ray spectral fitting. Mrk 34 is thus a 'gold standard' CT QSO2 and is the nearest non-merging system in this class, in contrast to the other local CT quasar NGC 6240, which is currently undergoing a major merger coupled with strong star formation. For typical X-ray bolometric correction factors, the accretion luminosity of Mrk 34 is high enough to potentially power the total infrared luminosity. X-ray spectral fitting also shows that thermal emission related to star formation is unlikely to drive the observed bright soft component below ∼3 keV, favoring photoionization instead.

79 ASTRONOMY AND ASTROPHYSICS↗

Sources of error in detonation calorimeters and error analysis for neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB)

Here, a calorimeter for measuring heats of detonation at Lawrence Livermore National Laboratory is described. A calibration precision of 0.2 % at the 95 % confidence interval (CI) is reported. Sources of uncertainty are discussed, including nonequivalent sources, which are those arising from differences between calibration and experimental tests. The systematic error due to nonequivalent sources is bounded to 0.19–0.22 % of the measured heat for a standard detonation test where the confinement material is gold. The recommendation is to correct for the systematic error by adding 0.19 % to the reported value and adding 0.03 % to the uncertainty. It is demonstrated that the precision of a detonation test is variable with testing duration because a source of uncertainty resides in the thermodynamic correction factor k6, which accounts for the contribution to heat by stirring; the generated power is additive and therefore highly impacted by total test time. The relative proportion also varies with the magnitude of heat release and sample size, adding variance to the weight of the error arising from the correction factor. A full error analysis based on the described sources of uncertainty is developed. The methodology is applied to a test series on neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB), demonstrating an ultimate precision of 0.7 % (single test) for materials testing and a relative standard deviation of 1.8 %.

47 OTHER INSTRUMENTATION↗

Thermal and Nonthermal Electron-ion Bremsstrahlung Spectrum from High-Temperature Plasmas

Electron-ion bremsstrahlung radiation from high-temperature plasmas is investigated. The first- and second-order Coulomb corrections in the nonrelativistic bremsstrahlung radiation power are obtained by the Elwert-Sommerfeld factor. In this paper, two cases of the electron distributions, the thermal and nonthermal power-law distributions, are considered. The inclusion of Coulomb corrections is necessary in deducing correctly the electron distribution function from radiation data. These results provide the correct information of electron distributions in high-temperature plasmas, such as in inertial confinement fusion plasmas and in the astrophysical hot thermal and nonthermal x-ray sources.

Jung, Young-Dae↗

SU-F-T-67: Correction Factors for Monitor Unit Verification of Clinical Electron Beams

Purpose: Monitor units calculated by electron Monte Carlo treatment planning systems are often higher than TG-71 hand calculations for a majority of patients. Here I’ve calculated tables of geometry and heterogeneity correction factors for correcting electron hand calculations. Method: A flat water phantom with spherical volumes having radii ranging from 3 to 15 cm was created. The spheres were centered with respect to the flat water phantom, and all shapes shared a surface at 100 cm SSD. D{sub max} dose at 100 cm SSD was calculated for each cone and energy on the flat phantom and for the spherical volumes in the absence of the flat phantom. The ratio of dose in the sphere to dose in the flat phantom defined the geometrical correction factor. The heterogeneity factors were then calculated from the unrestricted collisional stopping power for tissues encountered in electron beam treatments. These factors were then used in patient second check calculations. Patient curvature was estimated by the largest sphere that aligns to the patient contour, and appropriate tissue density was read from the physical properties provided by the CT. The resulting MU were compared to those calculated by the treatment planning system and TG-71 hand calculations. Results: The geometry and heterogeneity correction factors range from ∼(0.8–1.0) and ∼(0.9–1.01) respectively for the energies and cones presented. Percent differences for TG-71 hand calculations drop from ∼(3–14)% to ∼(0–2)%. Conclusion: Monitor units calculated with the correction factors typically decrease the percent difference to under actionable levels, < 5%. While these correction factors work for a majority of patients, there are some patient anatomies that do not fit the assumptions made. Using these factors in hand calculations is a first step in bringing the verification monitor units into agreement with the treatment planning system MU.

60 APPLIED LIFE SCIENCES↗

Absorptive corrections to the forward elastic proton-proton analyzing power A N

In the RHIC Polarized Atomic Hydrogen Gas Jet Target (HJET) measurements of the protonproton analyzing power A N (t), absorptive corrections to the electromagnetic form factor were not considered in the data analysis. Recently, these corrections were evaluated theoretically. However, the results were presented in form of integral expressions which were calculated numerically. In this note, the expressions are simplified to make them more suitable for the HJET data analysis. Possible effect of the absorptive corrections in the A N (t) measurement is discussed.

43 PARTICLE ACCELERATORS↗

Effective velocity power laws for electron-neutral collision frequencies

Calculations of electron transport coefficients in the ionosphere are simplified if the electron-neutral collision frequency can be expressed as a power law in velocity. A new method for determining the effective power law representation for electron-neutral collision frequencies of arbitrary velocity dependence is presented. This method is applied to ionospheric gases in a model calculation. Comparison with similar results of Schunk and Walker and with exact calculations of transport coefficient correction factors demonstrates this technique to be more accurate than the other. Effective power law indexes are computed for both Banks' and Itikawa's collision frequencies. Relative differences between these indexes are found to be considerably larger than the differences between the collision frequencies themselves; however, the effects on transport calculations are shown to be smaller.

Comfort, R. H.↗

MCNP AND CFD MODELING OF A SODIUM FAST REACTOR SUB-ASSEMBLY CHANNEL TO CAPTURE LOCALIZED TEMPERATURE PEAKING

Typical evaluation tools for sodium-cooled fast reactors (SFR) use simplified neutronic/thermal models to efficiently compute the power and temperature distributions within the core. However, their modeling capability can be limited in extreme cases such as when sharp inter-assembly power gradients occur, or for non-standard SFR assembly geometries. Higher fidelity tools that rely on Monte Carlo methods for neutron transport, and Computational Fluid Dynamics (CFD) for thermal analysis, are better suited in these instances. The higher accuracy comes at the cost of higher computational expense. MCNP and STAR CCM+ were selected for this analysis. While MCNP is capable of generating pin-level power distributions for a whole-core SFR model, it is prohibitively expensive to then conduct CFD analysis for every single assembly. A semi-empirical model was therefore developed to rapidly estimate pin temperature distributions throughout the whole core. It relies on a geometric correction factor for turbulent flow-mixing. The correction factor is obtained from a CFD simulation of a single fuel assembly with a uniform power distribution and an adiabatic boundary condition. Without using CFD, each sub-channel outlet temperature is calculated separately using 1-D heat-balance and Nusselt number correlations and the MCNP calculated pin-powers. The rudimentary 1-D model is then corrected for the flow-mixing effect based on the CFD data. The temperature calculation is performed by a code written in the Python language called CFD Monte-Carlo Developed Reconstruction of Sub-channel at a Quasi-Representative Level (CMDR-SQRL). CMDR-SQRL was shown to adequately predict CFD evaluated temperature distribution for a wide range of SFR configurations, including an extreme case with fuel assemblies nearby containing moderating material. The agreement demonstrates how geometric and power-driven effects can be decoupled within an SFR assembly. CMDR-SQRL is intended to be mainly used for scoping studies to provide core-wide evaluations efficiently.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Capabilities of TROPOMI NO2: Estimating NOX from North American Cities and Power Plants

The TROPOspheric Monitoring Instrument (TROPOMI) is used to derive top-down NOXemissions for twolarge power plants and three megacities in North America. Wefirst re-process the vertical column NO2with an improved airmass factor to correct for a known systematic low bias in the operational retrieval near urban centers. For the two power plants,top-down NOXemissions agree to within 10% of the emissions reported by the power plants. We then derive top-down NOXemissions rates for New York City, Chicago, and Toronto, and compare them to projected bottom-up emissions inventories. Inthis analysis of 2018 NOXemissions, wefind a +22% overestimate for New York City, a−21% underestimate in Toronto, andgood agreement in Chicago in the projected bottom-up inventories when compared to the top-down emissions. Top-downNOXemissions also capture intraseasonal variability, such as the weekday versus weekend effect (emissions are +45% larger onweekdays versus weekends in Chicago). Finally, we demonstrate the enhanced capabilities of TROPOMI, which allow us toderive a NOXemissions rate for Chicago using a single overpass on July 7, 2018. The large signal-to-noise ratio of TROPOMI iswell-suited for estimating NOXemissions from relatively small sources and for sub-seasonal timeframes.

TROPOspheric Monitoring Instrument (TROPOMI)↗