Search NASA⌕ Search

SEARCH · Search NASA

Results for “power inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

Rotary Power Transformer and Inverter Circuit

Noise lower than with sliprings. Rotary transformer transfers electric power across rotary joint. No wearing contacts, no contact noise, and no contamination from lubricants or wear debris. Because additional inductor not required, size and complexity of circuit reduced considerably.

Mclyman, C. W. T.↗

Comparative Small-Signal Stability Analysis of Grid-Forming and Grid-Following Inverters in Low-Inertia Power Systems: Preprint

Inverter-based resources (IBRs) are gradually replacing conventional fossil energy in modern power systems, which could make the system susceptible due to insufficient inertia, especially when moving towards a 100% inverter-based power grid. Grid-forming (GFM) and grid-following (GFL) controls are two common inverter control algorithms. However, the corresponding stability issues along with a comparative study on low-inertia power systems should still be investigated. This paper focuses on small-signal stability and conducts a comprehensive analysis of GFM and GFL controls, with emphases on the interactions between synchronous generators and IBRs. The detailed modeling of GFM and GFL inverters, and synchronous generators (SGs) are established. The coupling mechanism of IBRs and SGs is then conducted through participation factor analysis. The impacts of critical parameters on system stability are finally identified. The theoretical analyses are validated through time-domain simulation in MATLAB/Simulink.

grid-following↗

Impact of Increased Inverter Penetration on Power System Small-Signal Stability: Preprint

The transformation of the power system to include more distributed energy resources (DER) implies an increase in the number of inverter-based resources deployed on the grid. Envisioning future scenarios, this paper presents a small-signal stability analysis for a power grid comprising synchronous generators and inverter-based resources. Three types of inverter control are considered: grid following, droop-controlled grid forming, and virtual oscillator control grid forming. Although small-signal stability of power systems is a widely studied topic, systematic analysis of mixed machine-inverter systems with detailed control models at various inverter penetration levels are limited. This paper addresses the gap with numerical simulations tailored to the IEEE 39-bus system. Results show the system may become unstable at high inverter penetration level of grid-following inverters, and grid-forming inverter control can potentially improve system stability, thereby enabling very high level of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of quasi-square wave inverter as a power source for induction motors

The relative merits of quasi-square wave inverter-motor technology versus a sine wave inverter-motor system were investigated. The empirical results of several tests on various sizes of wye-wound induction motors are presented with mathematical analysis to support the conclusions of the study. It was concluded that, within the limitations presented, the quasi-square wave inverter-motor system is superior to the more complex sine wave system for most induction motor applications in space.

Guynes, B. V.↗

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Implementation of Automated Characterization of T-type based Power Module for PV Inverter Reliability Assessment

Reliability of power electronics holds the key for future power and energy systems since it is essential for system integration with renewables and energy storage systems. Variation of power module characteristics over the converter’s operational lifetime is a critical indicator to assess its reliability. Device characterization consists of different steps to collect, process, and visualize results, which is usually time-consuming, especially for power modules based on a non-phase-leg configuration, such as T-type circuits, widely applied for PV inverters. To reduce the time, ensure repeatability, and guarantee consistency, an automated test bench can be helpful. This paper focuses on a T-type-based power module and proposes a unique characterization platform and corresponding automation procedure and implementation. Considering the major characterization difference between T-type power modules over the conventional phase-leg power module, first, the special consideration for static characterization is highlighted. Second, the unique dynamic characterization design associated with the T-type power module is described. Finally, the automation of the power module characterization and the test platform is presented along with results and special considerations.

Siraj, Ahmed↗

Grid-Forming Inverters for Stability Improvements in Bulk Power Systems with High Inverter-Based Resources Penetration

The grid-forming inverter (GFM) has been considered recently as a means to enhance grid stability in areas with Inverter-based Resources (IBRs) concentration. This paper assesses the potential improvements the GFM can bring to Bulk-power Systems (BPS) through two distinct studies. The first study was conducted on West Texas in ERCOT with presence of more than 35GW of IBRs, the Grid-Following (GFL) batteries were replaced with GFM batteries. The results demonstrate that the GFM significantly improved the voltage profile and active power injection during and after a fault. The second study focused on a local area within ERCOT grid. In this case, a battery operating as GFL within the local study area was replaced with a GFM battery. The findings clearly illustrate that GFM can strengthen the area and allow a higher IBRs power generation and a higher power export from the local study area.

Quedan, Amro↗

Direct Envelope Modeling of Load-Resonant Inverter for Wireless Power Transfer Applications

This paper presents the application of direct envelope modeling technique to primary side LCC tuned resonant wireless power transfer system. The method adapted here decomposes the HF resonant inverter output to a fundamental component and two dominant sidebands. The small-signal dutycycle-to-primary-coil-current-envelope transfer function of a primary side LCC tuned WPT system is then derived as the summation of the responses to the fundamental and the sideband components. The theoretical and simulation results are in good agreement indicating the validity of the approach to be applied to WPT systems.

Galigekere, Veda Prakash↗

Development of a rotary power transformer and inverter drive for spacecraft

Many future satellites and spacecraft with spun and despun configurations will require the transfer of power across rotating interfaces in lieu of slip-rings and/or flexures. This is particularly true of spacecraft that have to demonstrate a long life expectancy. The rotary transformer has the desirable characteristics of high reliability and low noise, which qualify it as a potential replacement for slip rings. Development of a rotary power transformer follows the successful completion of a task to develop rotary signal-level transformers for the Galileo Spacecraft Project. The physical configuration of a rotary power transformer has a significant effect on its magnetic and electrical characteristics and therefore impacts the design of the dc/ac inverter driver. Important characteristics addressed during this development effort include: operating frequency, efficiency, transformer gap size, leakage inductance, and leakage flux. A breadboard inverter and rotary transformer were designed, fabricated and tested.

Mclyman, W. T.↗

Grid-Tied PV Inverter with Oversized Power Module to Increase its Low-Voltage Ride Through (LVRT) Capabilities and VAR Support

This paper proposes a novel design for grid-tied 3-ph Photovoltaic (PV) inverter to improve its low-voltage ride through (LVRT) response while significantly increasing its voltampere reactive (VAR) support during voltage sags. The literature available on LVRT for PV inverters can be grouped in solutions that dissipate the excess energy and those that temporary stores this energy. This paper proposes a third solution; oversizing inverter hardware components to safely transferring all the energy excess back to while maintaining the semiconductor under the maximum temperature limits. The advantages of the proposed approach are: 1) Improved LVRT capabilities and stable dc-link voltage control at MPP during sags. 2) Increased VAR support during voltage sags. 3) Increased use of renewable energy as all active power is injected back to the grid during voltage sags. Finally, the proposed solution is more cost effective compared with solutions that incorporate energy storage because only a few inverter components are required to be oversized. This paper also presents a detailed power loss analysis, which determined that that oversizing the power semiconductors has minimal impact in the inverter losses while significatively reducing the diode and IGBT conduction losses during both normal operation and grid fault conditions.

Ferrari Maglia, Max↗

Direct Phase-Angle Detection for Three-Phase Inverters in Asymmetrical Power Grids

This paper introduces a signal reformation based direct phase-angle detection (DPD-SR) technique for three-phase inverters supporting asymmetrical grids. Asymmetries in three-phase systems may happen because of unbalanced three-phase loads, which can lead to the voltage asymmetry at the terminals of grid-tied inverters. The proposed DPD-SR technique can detect the voltage phase-angle under asymmetrical conditions. The DPD-SR technique also offers precise and rapid phase-angle detection via signal reformation and trigonometric functions. In essence, the phase-angle detection is directly derived from the trigonometric properties of the line-line voltages, while signal reformation is implemented to handle asymmetrical voltages. The proposed method measures two line-line voltages and detects the phase-angle of a three-phase system under both symmetrical and asymmetrical conditions. Unlike classical phase-locked loop (PLL) techniques, DPD-SR does not need any closed-loop PI controller, which significantly reduces the complexity and the delay in detecting the phase-angle. In this paper, the efficacy of the proposed technique is examined in comparison with the state-of-the-art PLLs under asymmetrical conditions via a set of laboratory experiments. Here, the performance of the phase-angle detection is also tested as part of an inverter feeding an asymmetrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Guide to Current Limiting and Stability with Grid-Forming Inverters

The electric power grid is changing. For many decades, the synchronous generator - an electromechanical device invented in 1887 - has been the workhorse and backbone of power grids across the globe. Our entire infrastructure is built around it. But times change, and so does the power grid. Since the early 21st century, we have seen a gradual shift in modern power grids away from synchronous generators to ones dominated by power electronic inverter-based resources (IBRs). Sources such as photovoltaics, wind turbines, battery storage, fuel cells, and other technologies like high-voltage DC transmission interconnections all rely on an inverter to connect and interface with the grid. They are increasingly being installed on the grid to augment, or even replace, traditional energy sources. This change is a fundamental shift that brings tremendous technical challenges and questions: Can a power grid remain stable with many more inverter-based resources? How do we avoid more blackouts on the grid? How do we keep the grid secure and resilient during disturbances? After all, power electronic inverters are nothing like the big, rotating, iron-and-copper machines that the grid heavily relies on. Many of these questions can be answered by using grid-forming (GFM) inverters, yet many research challenges remain. This document explores GFM inverters and how they can help stabilize the future grid, especially during disturbances and contingencies. It summarizes a two-year research and development fellowship program at NREL. We point interested readers to more detailed works developed during the project along the way. Let's dive in

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stabilizing Inverter-Based Transmission Systems: Power Hardware-in-the-Loop Experiments with a Megawatt-Scale Grid-Forming Inverter

This article presents what the authors believe to be the first experimental verification of the ability of grid-forming (GFM) inverters to stabilize a transmission electric power system that is otherwise unstable. The experiments described here were performed using power hardware-in-the-loop (PHIL) simulation to connect a megawatt-scale battery inverter to a real-time electromagnetic transient (EMT) simulation of the near-future Maui power system. This allows the dynamic interactions between the inverter and the power system to be observed without putting the real power system at risk. The ability to use the actual inverter hardware removes the need to rely on a computer model approximation of the inverter's behavior.

electromagnetic transient simulations↗

Electric Power Industry Challenges Due to Increasing Shares of Inverter-Based Resources in Power Systems

The large-scale integration of variable renewable energy technologies around the world is forcing electric power systems into an unprecedented transition. This paper reports on power grid modernization and reliability issues related to the planning and operation of power systems with high levels of variable renewable energy. The contents of this paper stem from recent qualitative research in the form of a summary of an industry survey. The technical feedback from the interviewed 37 industry experts helped us identify 12 key areas of potential concern, which are discussed throughout this paper.

power system operation↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

Small-Signal Stability Analysis of Low-Inertia Power Grids with Inverter-Based Resources and Synchronous Condensers: Preprint

With the potential environmental impacts of conventional fossil fuels and the technology advances of grid interactive power electronics, inverter-based resources (IBRs) are playing a crucial role in modern power grids. However, due to the lack of physical inertia, IBRs are vulnerable to system disturbances. Further, conventional grid-following (GFL) inverters cannot actively establish the frequency and voltage, which could not be a appropriate solution for 100% inverter-based power grids. Grid-forming (GFM) control, as an emerging inverter control function, has drawn great attention in recent years, while it is still under development and pre-mature for large-scale field deployment. A potential solution for gradually transitioning into a 100% inverter-based power grid is to combine both IBRs and synchronous machines into a mixed generation portfolio. More importantly, synchronous machines can be operated as synchronous condensers (SCs) until they are retired. It is also worth mentioning that the stability analysis is of great importance to ensure the smooth transition from existing power grids to 100% inverter-based system, which is the main focus of this work with detailed modeling and modal analysis.

100% renewable↗