Vibration and noise measuring instruments built in the RSR

The demands placed upon vibration and noise measuring instruments are discussed. The instruments that are now being manufactured in the RSR are described, as well as those that are being made ready for manufacture, namely: the VP-3 portable vibrometer, the N2103 precision electronic vibrometer, the N2103 B sonometric preamplifier, as well as vibration transducers of the electrodynamic and piezoelectric types.

Georgescu, I.↗

A tracking polarimeter for measuring solar and ionospheric Faraday rotation of signals from deep space probes

A tracking polarimeter implemented on the 64-m NASA/JPL paraboloid antenna at Goldstone, Calif., is described. Its performance is analyzed and compared with measurements. The system was developed to measure Faraday rotation in the solar corona of the telemetry carrier from the Pioneer VI spacecraft as it was occulted by the sun. It also measures rotation in the earth's ionosphere and is an accurate method of determining spacecraft orientation. The new feature of this system is its use of a pair of quarter-wave plates to allow the synthesis of a rotating feed system, while requiring the rotation of only a single section of waveguide. Since the polarization sensing is done at RF and the receiver operates essentially as a null detector, the system's accuracy is superior to other polarization tracking schemes. In addition, the antenna size and maser preamplifier provide unsurpassed sensitivity. The associated instrumentation used in the Pioneer VI experiment is also described.

Ohlson, J. E.↗

An autoranging scanning system and compatible methods of noise reduction

The autoranging scanning system discussed combines in a unique way four different methods for removing noise. The system employs a narrow-band amplifier. Other noise reduction methods make use of digital summation, convolution numbers, and the coaddition of scans. The system was designed to digitize the output of an infrared spectrometer and to record it on magnetic tape. Light passes through a mechanical light chopper and the spectrometer optics, and falls on the PbS cell to produce a signal which is amplified by the first preamplifier.

Saufley, D. C.↗

Airoscope telemetry system

The AIROscope (Ames Infrared Observatory telescope) telemetry system is described from signal conditioning on the gondola to display and storage at the ground station. All analog and digital data from the systems and experiments on the gondola go to a PCM encoder which formats the data into 10-bit words. Therefore, 0.1-percent resolution is inherently available for experimental data. The coded bit stream directly modulates the carrier of the FM transmitter. To insure reliable transmission over a 650-km range an 11-watt FM transmitter operating at 1483.5 MHz is used on the gondola. Modulation is narrow band FM with a maximum deviation of plus or minus 500 kHz. The maximum modulation frequency is determined by the data bit rate which could be as high as 500 kbps. Presently, a rate of 20.48 kbps is used. The ground station receiving system includes a steerable antenna (19-db gain), preamplifier (21-db gain) and receiver. All data are recorded on a tape recorder. The recorded signal then can be played back through the PCM decommutator unit at a later time for detailed data analysis by the experimenter.

Pitts, K. J.↗

Wideband infrared heterodyne receiver front-end

A 10.6 micron infrared heterodyne receiver front end was developed for use in a wideband CO2 laser communications link. The infrared receiver employs an 850 MHz response PV HgCdTe photomixer which is mounted in a space quality housing, a low-noise 5 to 1500 MHz IF preamplifier, and a remote control panel. The receiver was designed to handle + or - 750 MHz of Doppler shift while providing an instantaneous information bandwidth of 400 MHz. The measured receiver sensitivity NEP was 1.0 x 10 to the 19th power W/Hz for a photomixer temperature of T sub m = 77 K and an IF beat frequency of 20 MHz and degraded to 1.75 x 10 to the 19th power W/Hz for T sub m = 130 K.

Peyton, B. J.↗

LK39F1 S/N U-1 infrared detector

A multilayered (Hg,Cd)Te detector is described with three infrared bands. Nominal cut-off wavelengths for each band are as follows: (1) Channel 1 - 3 microns, (2) Channel 2 - 6 microns, and (3) Channel 3 - 11 microns. The multilayered detector is mounted in a Honeywell LK39 glass dewar. Accompanying the detector/dewar assembly is a three-channel preamplifier package capable of switching each detector to the single channel input of the HRB Singer Reconfax 4 Mark 4 Infrared Scanner.

Source record↗

Recent developments in CID imaging

Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.

Michon, G. J.↗

Lithium drifted germanium system

General characteristics of the lithium-drifted germanium photodiode-Dewar-preamplifier system and particular operating instructions for the device are given. Information is included on solving operational problems.

Fjarlie, E. J.↗

S192 multispectral scanner channel 13 electromechanical noise investigation ECP-166

A review is presented of all data on the multispectral scanner having to do with low frequency noise. The noise is component-induced, either mechanical or electrical or a combination of both. To assist in understanding the source of the noise, several dynamic analyses both structural and electrical were made and are reported. A review is presented of structural resonance test data obtained with the use of an accelerometer and strain gage sensors. Results of an analysis of the natural frequencies of the Dewar leads is included along with an analysis of the S192 cooler and its supporting structure. Other topics discussed include electronic stability of the forward signal, automatic gain control, and the offset control feedback loops as well as the preamplifier which utilized on integrator feedback circuit.

Koumjian, H.↗

The mini-O, a digital superhet, or a truly low-cost Omega navigation receiver

A quartz tuning fork filter circuit and some unique CMOS clock logic methods provide a very simple OMEGA-VLF receiver with true hyperbolic station pair phase difference outputs. An experimental system was implemented on a single battery-operated circuit board requiring only an external antenna preamplifier, and LOP output recorder. A bench evaluation and preliminary navigation tests indicate the technique is viable and can provide very low-cost OMEGA measurement systems. The method is promising for marine use with small boats in the present form, but might be implemented in conjunction with digital microprocessors for airborne navigation aids.

Burhans, R. W.↗

Mini-O, simple Omega receiver hardware for user education

A problem with the Omega system is a lack of suitable low cost hardware for the small user community. A collection of do it yourself circuit modules are under development intended for use by educational institutions, small boat owners, aviation enthusiasts, and others who have some skills in fabricating their own electronic equipment. Applications of the hardware to time frequency standards measurements, signal propagation monitoring, and navigation experiments are presented. A family of Mini-O systems have been constructed varying from the simplest RF preamplifiers and narrowband filters front-ends, to sophisticated microcomputer interface adapters.

Burhans, R. W.↗

Fabrication of a focusing soft X-ray collector payload

A large area X-ray focusing collector with arc minute resolution and a position sensitive detector capable of operating in the soft X-ray region was developed for use on sounding rockets in studying stellar X-ray sources. The focusing payload consists of the following components, which are described: (1) a crossed paraboloid mirror assembly; (2) an aspect camera and star tracker; (3) a focal plane assembly containing an imaging proportional counter and its preamplifiers, high voltage power supplies and gas system; (4) a fiducial system; and (5) housekeeping, data handling, instrumentation and telemetry electronics. The design, tests, and operation are described.

Davis, J. M.↗

The radio astronomy experiment on Helios A and B /E 5c/

The NASA Goddard Space Flight Center radio astronomy experiment on Helios, identified as Experiment 5c, has sixteen observing frequencies over the range of 26.5 to 3000 kHz. The antenna consists of two extendible 15-m booms, forming an electric dipole, two high-impedance preamplifiers located at the root of the booms, and the 16-channel radiometer. Important information about propagation conditions, such as absorption, scattering and refraction, are expected from observations of radio emission regions at distances between 1 and 0,3 AU.

Weber, R. R.↗

A multichannel EEG telemetry system utilizing a PCM subcarrier

A multichannel personal-type telemetry system is described that utilizes PCM encoding for the most effective range with minimum RF bandwidth and noise interference. Recent IC developments (COS MOS) make it possible to implement a sophisticated encoding system (PCM) within the low power and size constraints necessary for a personal biotelemetry system. This system includes low-level high-impedance preamplifiers to make the system suitable for EEG recording.

Fryer, T. B.↗

Characterization of IRAS doped silicon detectors

Data are presented from a range of operating conditions which include background photo flux, operating temperature, and frequency. Each detector is equipped with a load resistor, a cryogenic field effect transistor preamplifier, and a temperature sensor. Data are also presented of detector signal, noise spectra, noise equivalent power, and spectral response.

Source record↗

Low-noise video amplifiers for imaging CCD's

Various techniques were developed which enable the CCD (charge coupled device) imaging array user to obtain optimum performance from the device. A CCD video channel was described, and detector-preamplifier interface requirements were examined. A noise model for the system was discussed at length and laboratory data presented and compared to predicted results.

Scinicariello, F.↗

A CCD scanned (Hg, Cd)Te array for earth viewing applications

A 9 channel demonstration of 10 micrometer photoconductive mercury cadmium telluride detector array, bipolar preamplifiers, and a Si CCD multiplexer, integrated into a focal plane assembly and operating at 105 K and at 17 Hz is reported. The result of a direct coupling experiment between a 5-micrometer photovoltaic mercury cadmium telluride photodiode and a CCD is revealed. No appreciable degradation in the signal-to-noise ratio was experienced.

Iwasa, S.↗

Thematic mapper critical elements breadboard program

A 40.6 cm bidirectional scan mirror assembly, a scan line corrector and a silicon photodiode array with integral preamplifier input stages were designed, fabricated, and tested to demonstrate performance consistent with requirements of the Hughes thematic mapper system. The measured performance met or exceeded the original design goals in all cases with the qualification that well defined and well understood deficiencies in the design of the photodiode array package will require the prescribed corrections before flight use.