Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototype buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Utility-scale Building Type Assignment Using Smart Meter Data

United States building energy use accounted for 40% of total energy use, 74% of peak demand, and $412 billion in 2019. Building energy modeling allows researchers to simulate building physics, gain insights into possible energy/demand saving opportunities, and assess cost-effective resilience amidst climate change. Many building features needed to create building energy models are readily available such as 2D footprints and LiDAR (height). A critical feature that is not generally obtainable is the building type. In partnership with a utility, a years worth of real-world, 15-minute electrical use data has been examined. The smart meter data is compared to 97 different prototype building energy models to assign building type. Real-world considerations including data preparation, quality assurance, and handling of missing values for advanced metering infrastructure data are addressed. Euclidean distance for pattern-matching of energy use, dynamic time warping, and time-window statistics with machine learning are compared for determining building type from measured electricity use.

Bass, Brett↗

Multizonal modeling of SARS-CoV-2 aerosol dispersion in a virtual office building

The dispersion of indoor airborne contaminants across different zones within a mechanically ventilated building is a complex phenomenon driven by multiple factors. In this study, we modeled the indoor dispersion of airborne SARS-CoV-2 aerosols within a US Department of Energy detailed medium office prototype building using CONTAM software. The aim of this study is to improve our understanding about how different parts of a building can experience varying concentrations of the airborne viruses under different circumstances of release and mitigation strategies. Results indicate that unventilated stairwells can have significantly higher concentrations of airborne viruses. The mitigation strategies of morning and evening flushing of conditioned zones were not found to be very effective. Instead, a constant high percentage of outdoor air in the supply mix, and the use of masks, portable HEPA air cleaners, MERV 13 or higher HVAC air filters, and ultraviolet germicidal irradiation disinfection were effective strategies to prevent airborne viral contamination in the majority of the simulated office building.

60 APPLIED LIFE SCIENCES↗

Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

code compliance↗

Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

code compliance, commercial energy code, energy co↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a web-based screening tool for ground source heat pump applications

Ground source heat pump (GSHP) technology has great potential to help the nation meet its energy and decarbonization goals, but several barriers hinder the wide application of GSHP. Important barriers include the lack of a coherent toolset for analyzing the technical feasibility and economic viability of the GSHP application. The current design and analysis methods are ineffective and require significant expertise to apply. Although building energy modeling is increasingly important in designing buildings, the tools for GSHP modeling and simulation are lacking. A web-based free-to-use tool is being developed for quick techno-economic analysis of GSHP applications in nearly any building in the United States. This tool is enabled by improvements in the calculation methodology to allow rapid sizing of borehole configurations that provide significant cost savings. The screening tool currently uses US Department of Energy (DOE) prototype building models and an extended g-function library to size ground heat exchangers and simulate the performance of GSHP systems. The team is integrating with DOE's Oak Ridge National Laboratory's AutoBEM program to automatically create a building model based on user inputs. This paper introduces the structure, components, features, and results of the web-based screening tool for GSHP applications. Future directions for further developing the tool are also discussed.

Liu, Xiaobing↗

Retrofitting Buildings with Solar-Reflective Roofs and Walls and its Impact on Peak Power Demand

Buildings are a major consumer of electricity in the United States and a significant portion of the consumption comes from heating, ventilation, and air-conditioning (HVAC) applications. Passive cooling strategies in the building envelope help to reduce the energy consumption for HVAC as well as peak electricity demand. Although being one of the most cost-effective passive cooling strategies, modern reflective roofing and reflective exterior wall technology is not well documented for its impact on peak demand. This study utilized whole building energy simulations on residential and commercial building prototype models to quantify the impact of cool roofs and cool exterior walls. The analysis was performed in three climate zones with varying insulation levels and solar reflectances for roofs and exterior walls. For both the residential and commercial buildings, the baseline building had a roof solar reflectance value of 0.10 and an exterior wall solar reflectance value of 0.25. The results from the simulations show that roofs and exterior walls with higher reflectance values increase cooling energy savings but can also increase heating energy consumption. The impact of changes in solar reflectances was greater in buildings with low roof/wall insulation levels compared to roofs/walls with higher insulation levels. A baseline for the simulations was set with the roof and exterior wall solar reflectances set at 0.1 and 0.25, respectively and simulations having varying roof and exterior wall thermal resistances were compared to the baselines.

14 SOLAR ENERGY↗

ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Quantitative Analysis

This report provides a final quantitative analysis to assess whether buildings constructed according to the requirements of ANSI/ASHRAE/IES Standard 90.1-2013 would result in improved energy efficiency in commercial buildings. The final analysis considered each of the 110 addenda to Standard 90.1-2010 that were included in Standard 90.1-2013. PNNL reviewed all addenda included by ASHRAE in creating Standard 90.1-2013 from Standard 90.1-2010, and considered their combined impact on a suite of prototype building models across all U.S. climate zones. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 110 total addenda, 30 were identified as having a measureable and quantifiable impact.

Halverson, Mark A.↗

ANSI/ASHRAE/IES Standard 90.1-2013 Preliminary Determination: Quantitative Analysis

This report provides a preliminary quantitative analysis to assess whether buildings constructed according to the requirements of ANSI/ASHRAE/IES Standard 90.1-2013 would result in improved energy efficiency in commercial buildings. The preliminary analysis considered each of the 110 addenda to Standard 90.1-2010 that were included in Standard 90.1-2013. PNNL reviewed all addenda included by ASHRAE in creating Standard 90.1-2013 from Standard 90.1-2010, and considered their combined impact on a suite of prototype building models across all U.S. climate zones. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s preliminary determination. However, out of the 110 total addenda, 30 were identified as having a measurable and quantifiable impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Food Service Building Asset Rating Methodology and Analysis

Food Service buildings are extremely energy intensive, using about 5 to 7 times more energy per square foot than conventional commercial buildings. Energy intensive commercial kitchen appliances are the primary drivers, often necessitating high exhaust air requirements. Currently, no standardized method exists to directly compare energy efficiency between different Food Service buildings. Different restaurant types have various types of appliances and cooked food throughput requirements and thus it is challenging to make direct comparisons. Past attempts to categorize Food Service use types into “Quick-Service” and “Full-Service” led to the development of the Standard 90.1 prototype building models. However, these models do not address the highly diverse Food Service use types. This paper proposes a methodology to compare Food Service buildings through an asset rating system. By identifying all unique systems in a kitchen and creating a common baseline, this methodology identifies approaches for normalizing variations in kitchen requirements and to compare all Food Service buildings against one another.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Food Service Building Asset Rating Methodology and Analysis

Food Service buildings are extremely energy intensive, using about 5 to 7 times more energy per square foot than conventional commercial buildings. Energy intensive commercial kitchen appliances are the primary drivers, often necessitating high exhaust air requirements. Currently, no standardized method exists to directly compare energy efficiency between different Food Service buildings. Different restaurant types have various types of appliances and cooked food throughput requirements and thus it is challenging to make direct comparisons. Past attempts to categorize Food Service use types into “Quick-Service” and “Full-Service” led to the development of the Standard 90.1 prototype building models. However, these models do not address the highly diverse Food Service use types. This paper proposes a methodology to compare Food Service buildings through an asset rating system. By identifying all unique systems in a kitchen and creating a common baseline, this methodology identifies approaches for normalizing variations in kitchen requirements and to compare all Food Service buildings against one another.

Asset Rating, commercial kitchens, building rating↗

Random Vibration Simulation and Testing of a Compact, Magnetic Bearing Supported Blower for Space Applications

NASA is developing a next-generation CO2 removal system, the Four Bed Carbon Dioxide Scrubber (4BCO2), which will use the International Space Station (ISS) as a testbed. A key component of both the existing and the new system is the blower that provides the airflow through the CO2 sorbent beds. To improve performance and reliability, magnetic bearings will be used in lieu of more conventional bearings (e.g. ball bearings or hydrodynamicbearings) to improve resistance to contaminants and enable extensibility with regards to blower speed, pressure rise and mass flow rate. The new blower features a high-efficiency permanent magnet motor, a five-axis, active magnetic bearing system, and a compact controller containing both a variable speed drive and magnetic bearing controller. The blower uses a centrifugal impeller to pull air from the inlet port and drive it through an annular space around the motor and magnetic bearing components to the exhaust port. Technical challenges of the blower and controller development include survival of the blower system under launch random vibration loads, operation in microgravity, packaging under strict size and weight requirements, and successful operation during 4BCO2 operational changeovers. Each serial build of the blower must pass a severe random vibration test to prove it will survive launch conditions. This paper discusses the vibration test requirements and provides details of a simulation performed to estimate the peak backup bearing displacements and loads. Results from the successful random vibration testing of the prototype build are discussed and compared to the simulation.

bearings↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

NATIONAL IMPACT OF ANSI/ASHRAE/IES STANDARD 90.1-2016

ANSI/ASHRAE/IES Standard 90.1 is the U.S. national commercial building model energy code and it has a significant impact on many programs and policies that impact energy savings across the United States and the world. Determining the energy savings from the latest edition of Standard 90.1 relative to previous editions is critical for beyond code programs and for others setting energy performance targets. Pacific Northwest National Laboratory developed prototype building models to determine the energy savings from 90.1-2016 standard. This paper presents the rigorous modeling and development process that PNNL has established and its applications. In addition, the energy savings results of Standard 90.1-2016 are described.

Standard 90.1-2016, energy efficency, energy codes↗

National Impact of ANSI/ASHRAE/IES Standard 90.1-2016

ANSI/ASHRAE/IES Standard 90.1 is the U.S. national commercial building model energy code and it has a significant impact on many programs and policies that impact energy savings across the United States and the world. Determining the energy savings from the latest edition of Standard 90.1 relative to previous editions is critical for beyond code programs and for others setting energy performance targets. Pacific Northwest National Laboratory developed prototype building models to determine the energy savings from 90.1-2016 standard. This paper presents the rigorous modeling and development process that PNNL has established and its applications. In addition, the energy savings results of Standard 90.1-2016 are described.

Liu, Bing↗

Scout: An Impact Analysis Tool for Building Energy-Efficiency Technologies

Evaluating the national impacts of candidate U.S. building energy-efficiency technologies has historically been difficult for organizations with large energy efficiency portfolios. In particular, normalizing results from technology-specific impact studies is time-consuming when those studies do not use comparable assumptions about the underlying building stock. To equitably evaluate its technology research, development, and deployment portfolio, the U.S. Department of Energy's Building Technologies Office has developed Scout, a software tool that quantitatively assesses the energy and CO2 impacts of building energy-efficiency measures on the national building stock. Scout efficiency measures improve upon the unit performance and/or lifetime operational costs of an equipment stock baseline that is determined from the U.S. Energy Information Administration Annual Energy Outlook (AEO). Scout measures are characterized by a market entry and exit year, unit performance level, cost, and lifetime. To evaluate measures on a consistent basis, Scout uses EnergyPlus simulation on prototype building models to translate measure performance specifications to whole-building energy savings; these savings impacts are then extended to a national scale using floor area weighting factors. Scout represents evolution in the building stock over time using AEO projections for new construction, retrofit, and equipment replacements, and competes technologies within market segments under multiple adoption scenarios. Scout and its efficiency measures are open-source, as is the EnergyPlus whole building simulation framework that is used to evaluate measure performance. The program is currently under active development and will be formally released once an initial set of measures has been analyzed and reviewed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reflector Technology Development and System Design for Concentrating Solar Power Technologies

Alcoa began this program in March of 2008 with the goal of developing and validating an advanced CSP trough design to lower the levelized cost of energy (LCOE) as compared to existing glass based, space-frame trough technology. In addition to showing a pathway to a significant LCOE reduction, Alcoa also desired to create US jobs to support the emerging CSP industry. Alcoa's objective during Phase I: Concept Feasibility was to provide the DOE with a design approach that demonstrates significant overall system cost savings without sacrificing performance. Phase I consisted of two major tasks; reflector surface development and system concept development. Two specific reflective surface technologies were investigated, silver metallized lamination, and thin film deposition both applied on an aluminum substrate. Alcoa prepared samples; performed test validation internally; and provided samples to the NREL for full-spectrum reflectivity measurements. The final objective was to report reflectivity at t = 0 and the latest durability results as of the completion of Phase 1. The target criteria for reflectance and durability were as follows: (1) initial (t = 0), hemispherical reflectance >93%, (2) initial spectral reflectance >90% for 25-mrad reading and >87% for 7-mrad reading, and (3) predicted 20 year durability of less than 5% optical performance drop. While the results of the reflective development activities were promising, Alcoa was unable to down-select on a reflective technology that met the target criteria. Given the progress and potential of both silver film and thin film technologies, Alcoa continued reflector surface development activities in Phase II. The Phase I concept development activities began with acquiring baseline CSP system information from both CSP Services and the DOE. This information was used as the basis to develop conceptual designs through ideation sessions. The concepts were evaluated based on estimated cost and high-level structural performance. The target criteria for the concept development was to achieve a solar field cost savings of 25%-50% thereby meeting or exceeding the DOE solar field cost savings target of $\$$350/m 2 . After evaluating various structural design approaches, Alcoa down-selected to a monocoque, dubbed Wing Box, design that utilizes the reflective surface as a structural, load carrying member. The cost and performance potential of the Wing Box concept was developed via initial finite element analysis (FEA) and cost modeling. The structural members were sized through material utilization modeling when subjected to representative loading conditions including wind loading. Cost modeling was utilized to refine potential manufacturing techniques that could be employed to manufacture the structural members. Alcoa concluded that an aluminum intensive collector design can achieve significant cost savings without sacrificing performance. Based on the cost saving potential of this Concept Feasibility study, Alcoa recommended further validation of this CSP approach through the execution of Phase II: Design and Prototype Development. Alcoa Phase II objective was to provide the DOE with a validated CSP trough design that demonstrates significant overall system cost savings without sacrificing performance. Phase II consisted of three major tasks; Detail System Design, Prototype Build, and System Validation. Additionally, the reflector surface development that began in Phase I was continued in Phase II. After further development work, Alcoa was unable to develop a reflective technology that demonstrated significant performance or cost benefits compared to commercially available CSP reflective products. After considering other commercially available reflective surfaces, Alcoa selected Alano's MIRO-SUN product for use on the full scale prototype. Although MIRO-SUN has a lower specular reflectivity compared to other options, its durability in terms of handling, cleaning, and long-term reflectivity was deemed the most important attribute to successfully validate Alcoa's advanced trough architecture. To validate the performance of the Wing Box trough, a 6 meter aperture by 14 meter long prototype trough was built. For ease of shipping to and assembly at NREL's test facility, the prototype was fabricated in two half modules and joined along the centerline to create the Wing Box trough. The trough components were designed to achieve high precision of the reflective surface while leveraging high volume manufacturing and assembly techniques.

14 SOLAR ENERGY↗