Benefit FOA FY2015 - Solid State Magnetocaloric Air Conditioner (Final Report)

The active magnetic refrigeration (AMR) cycle holds great promise to reduce energy consumption of space cooling and heating. It is estimated that it could achieve up to 25% improvement in energy efficiency over conventional vapor compression systems. Prototypes have been built and demonstrated the working principles and energy benefits of the technology. These prototypes however were of low specific cooling power, defined as cooling power obtainable from unit mass of magnetocaloric materials (MCM). Specific cooling power is inversely proportional to the cost of the system. Therefore, for the magnetocaloric technology to be commercially viable, the specific cooling power must be increased. To increase the specific cooling power, for any MCM, the frequency of operation must increase. However, the maximum frequency that an AMR can operate at is limited by the residence time that is required to transfer heat in and out of the regenerator during the cold and got blows. This time length is dependent on the thermal conductivity of the heat transfer medium. The higher the thermal conductivity of the heat transfer medium, the faster heat can be transferred between the medium and the MCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combined TREAT-LOC & SATS Integral LOCA Experiment Plan

The Transient Reactor Test Facility (TREAT) loss-of-coolant (LOC) and highburnup (HBu) experiment series, along with the Severe Accident Test Station (SATS) HBu experiment series, are integral LOC accident (LOCA) experiments planned under the Department of Energy (DOE) Advanced Fuels Campaign (AFC) program, which aims to support burnup extension needs by addressing identified R&D priorities in order to achieve an improved understanding of fuel fragmentation, relocation, and dispersal (FFRD) of HBu fuel during LOCA events. Priorities have been identified by the Electric Power Research Institute (EPRI)’s Collaborative Research on Advanced Fuel Technologies (CRAFT) Fuel Performance and Testing Technical Experts Group (FPTTEG). The data produced under this plan will be used to further validate and confirm existing models and inform future R&D and model development. The experimental program was specifically developed to address data gaps and opportunities identified via detailed review of the existing public knowledge base on LOCA FFRD, as well as reviewing specific experimental development activities regarding prototypic LOCA conditions for light-water reactor (LWR) systems. The test program relies on a unique combination of in- and out-of-pile experimental approaches to provide a clear tieback to the existing integral and semi-integral LOCA experiment database, using state-of-the-art facilities. More importantly, the program will systematically investigate the impacts of prototypic HBu fuel/cladding thermomechanical behaviors under postulated LWR LOCA conditions not yet fully investigated. These conditions correspond with prototypic decay-energy heatup (DEH) and stored-energy heatup (SEH) conditions. First, TREAT’s unique capability will enable the first evaluation of the impact of SEH conditions on HBu fuels. The test program will emphasize the development of an improved mechanistic understanding of key phenomena through independent experimental systems, development of a database to support fuel performance modeling tools, world-leading advanced materials characterization, and the most advanced approach to in situ diagnostics ever deployed to evaluate FFRD. The results will represent a significant leap forward in evaluating prototypic conditions and novel data to support modeling development and validation, as well as to inform the technical basis for LOCA-induced FFRD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Loss of Coolant High Burnup (LOC-HBu) Program

LOC-HBu is a joint experimental program (JEEP) operating within the Nuclear Energy Agency’s (NEA’s) framework for irradiation experiments II (FIDES-II). LOC-HBu is dedicated to the understanding of light water reactor (LWR) fuel performance at high burnup under loss of coolant accident (LOCA) conditions. LOC-HBu aims to support burnup extension needs by addressing identified R&D priorities to achieve an improved understanding of fuel fragmentation, relocation, and dispersal (FFRD) of HBu fuel during LOCA events. The need for such experiments was identified in the United States by the Fuel Performance Testing Technical Expert Group (FPTTEG) under the Electric Power Research Institute (EPRI)’s Collaborative Research on Advanced Fuel Technologies (CRAFT) framework. A combined in-pile and furnace testing program plan was developed by researchers at Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) which was reviewed and approved by the FPTTEG Combined TREAT-LOC and SATS LOCA Experiment Plan. The first 4 tests identified in this plan are being put forward by the U.S. Department of Energy (U.S. DOE) and INL for inclusion in the FIDES-II second triannual work period. The data produced under this plan will be used to further validate and confirm existing models and inform future R&D and model development. The experimental program was specifically developed to address data gaps and opportunities identified via detailed review of the existing public knowledge base on LOCA FFRD, as well as reviewing specific experimental development activities regarding prototypic LOCA conditions for light-water reactor (LWR) systems. The program will systematically investigate the impacts of prototypic HBu fuel/cladding thermomechanical behaviors under postulated LWR LOCA conditions not yet fully investigated. These conditions correspond with prototypic decay-energy heatup (DEH) and stored-energy heatup (SEH) conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Post-irradiation examination of UN-Mo-W fuels for space nuclear propulsion

The National Aeronautics and Space Administration's return to space nuclear propulsion stems from the need for a more efficient method of space travel. Nuclear thermal propulsion systems have been shown to be two times more efficient than chemical propulsion. NASA's Sirius program was created to fabricate and test fuels for space nuclear propulsion, specifically to determine their performance under prototypical startup conditions. The Sirius project featured 4 test capsules, Sirius-1 featured uranium nitride fuel dispersed in a matrix of tungsten and rhenium, while Sirius-2A, -2B, and -3 featured uranium nitride-molybdenum-tungsten fuel (UN-Mo-W). This study discusses the Sirius-2A and -2B irradiation experiments at the Idaho National Laboratory, specifically their performance under irradiation at the Transient Reactor Test Facility. It was found that the fuel samples overall did not exhibit significant cracking, though the Sirius-2A fuel did have one large crack on the surface of the fuel. There was minimal hydrogen absorption in the samples, though it is unknown if the absorption occurred during irradiation or during fabrication. Mechanical testing indicated that the UN fuel demonstrated ceramic behavior as expected, and the Mo/W matrix demonstrated linear elastic behavior to failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrodynamic and Structural Response Modeling of a Prototype Floating Membrane Reservoir System for Pumped Storage Hydropower

Hydrodynamic, computational fluid dynamics, and finite-element modeling were performed for a novel floating membrane reservoir system design for closed-loop pumped storage hydropower application. The conceptual design, which is now protected under an invention disclosure with a patent pending, offers a potential low-cost, low-impact solution to address the high costs, long investment return periods, and environmental disruptions encountered with traditional pumped storage development while offering modularity to enable replication at many locations. Prior to physical tests on a prototype, this paper documents the response analysis and modeling completed to simulate hydraulic and structural performance under different reservoir deployment and alignment arrangements, evaluate system stability, and refine the conceptual design. The results indicate that the excitation frequency from vortex shedding is at least an order of magnitude lower than the water sloshing frequencies in the reservoir, the structural natural frequency of the entire reservoir, and the vibrational frequencies of the side membranes, although excitation frequencies from other sources could cause mechanical resonance under certain conditions. To control destabilizing effects and prevent rocking motion and vibration, the authors conclude that the design could be improved by including a support structure around the floating reservoir, which could also provide floating-membrane containment, improve safety, and facilitate vertical reservoir movement. These conclusions, based on hydrodynamic and structural response modeling, help define specifications for upcoming full-scale prototype construction, deployment, and testing. This study demonstrates standard modeling technique application to an innovative design for which similar applications have not been previously evaluated. As a result, the refined design is capable of improving the scalability and feasibility of pumped storage hydropower in the United States and will be considered for commercialization following prototype testing.

13 HYDRO ENERGY↗

Assessing the Impact of Cybersecurity Attacks on Energy Systems

This paper investigates the cyber resiliency of future power systems with high penetration of distributed energy resources using advanced distributed and (or) hierarchical control architectures. Specifically, we simulate cyberattacks on three prototypical use cases, and we identify attack scenarios that are the most damaging to the overall system performance. We show that these attacks can have a significant impact on grid operation. Results provide additional insights into the robustness of the system to the most common cyberattacks.

buildings↗

A compact linear accelerator based on a scalable microelectromechanical-system RF-structure

Here, a new approach for a compact radio-frequency (RF) accelerator structure is presented. The new accelerator architecture is based on the Multiple Electrostatic Quadrupole Array Linear Accelerator (MEQALAC) structure that was first developed in the 1980s. The MEQALAC utilized RF resonators producing the accelerating fields and providing for higher beam currents through parallel beamlets focused using arrays of electrostatic quadrupoles (ESQs). While the early work obtained ESQs with lateral dimensions on the order of a few centimeters, using a printed circuit board (PCB), we reduce the characteristic dimension to the millimeter regime, while massively scaling up the potential number of parallel beamlets. Using Microelectromechanical systems scalable fabrication approaches, we are working on further red ucing the characteristic dimension to the sub-millimeter regime. The technology is based on RF-acceleration components and ESQs implemented in the PCB or silicon wafers where each beamlet passes through beam apertures in the wafer. The complete accelerator is then assembled by stacking these wafers. This approach has the potential for fast and inexpensive batch fabrication of the components and flexibility in system design for application specific beam energies and currents. For prototyping the accelerator architecture, the components have been fabricated using the PCB. In this paper, we present proof of concept results of the principal components using the PCB: RF acceleration and ESQ focusing. Finally, ongoing developments on implementing components in silicon and scaling of the accelerator technology to high currents and beam energies are discussed.

43 PARTICLE ACCELERATORS↗

Prototype Data Models and Data Dictionaries for Hanford Sediment Physical and Hydraulic Properties

The Remediation Decision Support (RDS) project, managed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) and the CH2M HILL Plateau Remediation Company (CHPRC), has been compiling physical and hydraulic property data and parameters to support risk analyses and waste management decisions at Hanford. In FY09 the RDS project developed a strategic plan for a physical and hydraulic property database. This report documents prototype data models and dictionaries for these properties and associated parameters. Physical properties and hydraulic parameters and their distributions are required for any type of quantitative assessment of risk and uncertainty associated with predictions of contaminant transport and fate in the subsurface. The central plateau of the Hanford Site in southeastern Washington State contains most of the contamination at the Site and has up to {approx}100 m of unsaturated and unconsolidated or semi-consolidated sediments overlying the unconfined aquifer. These sediments contain a wide variety of contaminants ranging from organic compounds, such as carbon tetrachloride, to numerous radionuclides including technetium, plutonium, and uranium. Knowledge of the physical and hydraulic properties of the sediments and their distributions is critical for quantitative assessment of the transport of these contaminants in the subsurface, for evaluation of long-term risks and uncertainty associated with model predictions of contaminant transport and fate, and for evaluating, designing, and operating remediation alternatives. One of the goals of PNNL's RDS project is to work with the Hanford Environmental Data Manager (currently with CHPRC) to develop a protocol and schedule for incorporation of physical property and hydraulic parameter datasets currently maintained by PNNL into HEIS. This requires that the data first be reviewed to ensure quality and consistency. New data models must then be developed for HEIS that are approved by the HTAG that oversees HEIS development. After approval, these new data models then need to be implemented in HEIS by the EDM before there is an actual repository for the data. This document summarizes modifications to previously developed data models, and new data models and data dictionaries for physical and hydraulic property data and parameters to be transferred to HEIS. A prototype dataset that conforms to the specifications of these recommended data models has been identified and processed, and is ready for transfer to CHPRC for inclusion in HEIS. Additional datasets are planned for transfer from PNNL to CHPRC in FY11.

99 GENERAL AND MISCELLANEOUS↗

High Energy High Power Battery Exceeding PHEV40 Requirements

TIAX has developed long-life lithium-ion cells that can meet and exceed the energy and power targets (200Wh/kg and 800W/kg pulse power) set out by DOE for PHEV40 batteries. To achieve these targets, we selected and scaled-up a high capacity version of our proprietary high energy and high power CAM-7® cathode material. We paired the cathode with a blended anode containing Si-based anode material capable of delivering high capacity and long life. Furthermore, we optimized the anode blend composition, cathode and anode electrode design, and selected binder and electrolyte compositions to achieve not only the best performance, but also long life. By implementing CAM-7 with a Si-based blended anode, we built and tested prototype 18650 cells that delivered measured specific energy of 198Wh/kg total energy and 845W/kg at 10% SOC (projected to 220Wh/kg in state-of-the-art 18650 cell hardware and 250Wh/kg in 15Ah pouch cells). These program demonstration cells achieved 90% capacity retention after 500 cycles in on-going cycle life testing. Moreover, we also tested the baseline CAM-7/graphite system in 18650 cells showing that 70% capacity retention can be achieved after ~4000 cycles (20 months of on-going testing). Ultimately, by simultaneously meeting the PHEV40 power and energy targets and providing long life, we have developed a Li-ion battery system that is smaller, lighter, and less expensive than current state-of-the-art Li-ion batteries.

25 ENERGY STORAGE↗

Searching for Low-Mass Dark Matter with SuperCDMS Soudan Detectors

SuperCDMS is a direct-detection dark matter (DM) experiment that uses cryogenically cooled germanium and silicon detectors to search for interac- tions between DM particles and detector nuclei, and in this thesis I describe my contributions to the experiment. I start with a brief review of DM and motivate the possibility of its de- tection in underground laboratories with sensitive detectors, and I review the SuperCDMS detector fundamentals. Then I focus on detector develop- ment for the future generation of the experiment, which will deploy an array of detectors at SNOLAB in Sudbury, Canada. Specifically I describe char- acterization of prototype detectors from surface facility testing, and discuss measurements of critical values that determine the detectors’ sensitivity to DM particles, such as the baseline resolution and the phonon collection ef- ficiency. I also describe analysis techniques developed to measure intrinsic detector noise in a high radiation environment such as a surface test facility. In the final chapters I describe a DM search analysis using four months of data from operation of SuperCDMS detectors in the Soudan Mine in northern Minnesota. I discuss how a particular detector operating mode, called CDMSlite, lowers the energy threshold of the detectors in order to improve the sensitivity to low-mass DM particles. I also present new analysis techniques that optimize the sensitivity to low-mass DM particles, including noise discrimination with multivariate classifiers, instrumental background modeling, and a profile likelihood signal and background fitting approach. In this analysis we set an upper limit on the DM-nucleon scattering cross section in germanium that is a factor of 2.5 improvement over the previous CDMSlite result for a DM mass that is five times the proton rest mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel materials irradiation and pre-characterization plans for high-power targetry applications

The multi-megawatt proton beams that will be employed at future accelerator complexes introduce many new challenges for next-generation targetry systems, primarily due to the increased levels of beam-induced radiation damage combined with thermal shock effects during a beam pulse. Novel material classes, such as high-entropy alloys and electro-spun nanofibers are currently being investigated as materials that will be more tolerant of these effects in high beam power applications. Low-energy ion irradiation will be used for pre-screening and down selecting candidate novel materials prior to prototypic high-energy irradiation studies. Specific nano and micro-scale characterization techniques will be used to evaluate the radiation damage and thermal shock resistance of the new materials. Irradiation induced lattice spacing alteration and defect concentrations, as well as mechanical and thermal properties of the novel materials will be measured and compared to those of conventional targetry materials. This poster will detail plans for initial low-energy ion irradiation tests, and the post-irradiation examination techniques that will be used to develop and screen these novel target materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Prototype Software to Demonstrate a Data Catalog for Hanford Environmental Datasets

Ensuring that data on long-term environmental remediation at the Hanford Site is high-quality, traceable, and easily accessible is an ongoing challenge, complicated by decades of data collection, multiple contractors maintaining data sources, and the wide range of data types. A centralized data catalog, known as the Hanford Environmental Information and Data Index (HEIDI), has been under development as part of the Hanford Environmental Data Management (HEDM) program to address these challenges. HEIDI fulfills a critical need to bring together a wide range of data types and sizes from multiple authoritative data sources, while documenting the data pedigree and quality information (i.e., traceable to the data source/originator). This document describes additional development and maturation of the HEIDI prototype. Key accomplishments included deploying the catalog software, Esri Geoportal Server, on a server accessible to Hanford Local Area Network users, conducting cybersecurity evaluations, investigating integrated authentication solutions, and conducting functional testing of the catalog prototype. The server-based deployment enabled targeted feedback, leading to enhancements including improved accessibility features and an expanded metadata schema. Specifications for the server-based deployment of the prototype catalog and the HEIDI metadata schema are provided in this document to support subsequent HEIDI deployment by the U.S. Department of Energy Richland Operations Office.

54 ENVIRONMENTAL SCIENCES↗

Prototype Courthouse Building Energy Model: Building Characteristics and Energy Simulation Results

To coordinate commercial building energy research activities, the US Department of Energy uses a suite of commercial prototype building models, which includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types, including a courthouse. Informed by building design guides, databases, documented projects, and personal communication with courthouse design experts, a 3-story, 4-courtroom, 69,324 ft 2 building was considered as the prototype courthouse to represent an average-sized courthouse in the United States. This report documents the building and system characteristics of the prototype courthouse model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. To verify the energy simulation results, energy use statistics of existing courthouses from different building database are also presented. Based on the simulated energy use, the site energy use intensity of the prototype courthouse ranged from 45 to 159 kBtu/ft 2 compared with the average energy use intensity of 94.7 kBtu/ft 2 for the courthouse building type in the 2012 Commercial Building Energy Consumption Survey (CBECS) Data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Risk Analysis and Decision Making Framework

Commercialization of new carbon capture simulation initiative (CCSI) technology will include two key elements of risk management, namely, technical risk (will process and plant performance be effective, safe, and reliable) and enterprise risk (can project losses and costs be controlled within the constraints of market demand to maintain profitability and investor confidence). Both of these elements of risk are incorporated into the risk analysis subtask of Task 7. Thus far, this subtask has developed a prototype demonstration tool that quantifies risk based on the expected profitability of expenditures when retrofitting carbon capture technology on a stylized 650 MW pulverized coal electric power generator. The prototype is based on the selection of specific technical and financial factors believed to be important determinants of the expected profitability of carbon capture, subject to uncertainty. The uncertainty surrounding the technical performance and financial variables selected thus far is propagated in a model that calculates the expected profitability of investments in carbon capture and measures risk in terms of variability in expected net returns from these investments. Given the preliminary nature of the results of this prototype, additional work is required to expand the scope of the model to include additional risk factors, additional information on extant and proposed risk factors, the results of a qualitative risk factor elicitation process, and feedback from utilities and other interested parties involved in the carbon capture project. Additional information on proposed distributions of these risk factors will be integrated into a commercial implementation framework for the purpose of a comparative technology investment analysis.

01 COAL, LIGNITE, AND PEAT↗

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

20 Channel Quench Detector

A multi-channel quench detector is useful for troubleshooting of prototype HTC superconducting magnets with current lead connections and imbedded splices. There are commercially available quench detectors, but not with as many channels, or with the particular functionality of this unit. This unit was designed specifically for cold testing of a superconducting sextupole prototype, which is wound with many turns of HTC ribbon. Associated with the current lead connections and the imbedded splices are 18 voltage taps, thus 17 quench detection channels are required to monitor the condition of the magnet. Of the 20 differential input channels in this quench detection unit, 19 are configured in a ladder network. The 20th channel is isolated and can be connected across any pair of voltage taps. This quench detector is designed to be used to monitor the condition of a series-connected superconducting magnet powered by a unipolar supply, and therefore the polarity and sequence of the voltage taps must be observed. There are 20 toggle switches and 20 red LEDs on the front panel of the unit which are associated with the 20 quench detection channels. There are also 2 green LEDs to indicate the state of the +5 V and +25 V internal supplies. Channel input impedance is ~10 kΩ. The input lines are diode protected against negative voltage transients and can tolerate up to +25 V, which is greater than the compliance of supplies typically used to power superconducting magnets. The front panel switches are used to enable or disable individual channels. If a channel is not used it is disabled. There are 20 pots on the quench detector PCB. They provide adjustment for the sensitivity of each of the 20 channels. There is an onboard reference to facilitate channel sensitivity calibration. The detection sensitivity range is from ~27 mV to ~700 mV. Typically all channels are set for the same sensitivity. The response time is ~20 μs, but the time constant can be increased if desired by adding a single capacitor to each channel. When the magnet under test is cooled to the superconducting state and the supply current to the windings is slowly ramped up to the set point, if there is a voltage rise across a pair of voltage taps which exceeds the quench detection limit of a given channel, then the front panel LED for that channel illuminates and all other channels are disabled within ~25 ns. Thus only the first quench is detected for the channels which are enabled. A pushbutton switch on the front panel is used to reset a quench detection. A 25 pin D-subminiature connector on the back of the unit is used for the channel inputs. TTL level ‘quench’ and ‘quench-not’ signals, and DPDT relay contacts, are provided through a 9 pin D-subminiature connector on the back to indicate a detected quench condition, which could be used to disable the power supply and engage an energy absorber.

47 OTHER INSTRUMENTATION↗

Towards Vendor and Operating System Independence of USB-based portable multi-channel analyzers

The nuclear measurements group is called on to develop portable, user friendly systems that performs at, or near, laboratory standards. These systems typically consist of a detector and a USB-based multi-channel analyzer. An ORTEC digi-Base is an example of a USB-based portable multi-channel analyzer with 14-pin photomultiplier tube base for gamma-ray spectroscopy applications with NaI(Tl) and other scintillation detectors. Operating system independence - we want to be able to develop applications that are 'future-proof' and can run on the best hardware for the job: desktop, laptop, tablet, phone, or embedded device. To do that we need our software to be operating system independent. Hardware vendor independence - to use the most appropriate equipment for the job, while still maintaining our rapid method development, we would like our software that uses this equipment to be independent of the specific vendor or model of the hardware. To do that we need a common interface to each vendor's equipment (high voltage, gain, start, stop, clear, etc.) In prior work, we were able to use an existing library to communicate with an ORTEC digi-base via Linux and Android. However the application developed did not have a user friendly front-end. Part of this work was to develop a simple user interface to control the settings of the hardware from Android. While OS independence is the final goal, another goal is standardized software for user-application development. For current purposes those standard systems are Windows 7, Windows 10, and Python 3. Our next step was to develop a common software interface between a front-end user interface and back-end hardware communication software. This was done using Python's Ctypes library. Ctypes is a foreign function library for Python. It provides C compatible data types, and allows calling functions in DLLs or shared libraries. It can be used to wrap these libraries in pure Python. Ctypes exports the cdll, and Windows windll and oledll objects, for loading dynamic link libraries. You load libraries by accessing them as attributes of these objects. cdll loads libraries which export functions using the standard cdecl calling convention. The first steps of developing the common software interface have been done. Once the software interface has been developed the next goal will be to develop hardware specific back-end software that way rapid user facing software can be developed using equipment that is 'on-hand' and once finished prototyping, the 'best' hardware can be chosen for the specific implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗