A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

Vibrational sum frequency generation using shaped near infrared light

A vibrational sum frequency generation spectroscopy system with pulse shaping is provided. The pulse shaping provides tunable NIR-Shaped light pulses based on user input parameters which may be specified to customize the system for different experimental and testing conditions or needs.

42 ENGINEERING↗

Robust control of the minima of high-order harmonics by fine-tuning the alignment of CO 2 molecules for shaping attosecond pulses and probing molecular alignment

In a recent paper, we reported that the position and depth of the minima in the harmonic spectra of CO 2 molecules can be dramatically manipulated by a slight change of the degree of alignment, thus providing a convenient method of shaping attosecond pulses which could lead to the splitting of a typical single attosecond burst into two. Here, we demonstrate that harmonic minima can also be dramatically controlled by changing the pump-probe angles to shape attosecond pulses. In the meanwhile, since the pump-probe angle-dependent harmonic spectra are very sensitive to the degree of alignment, harmonic spectra can also be used to calibrate the alignment distribution of molecules. In this work we identify such robust control of harmonic generation is due to the optical property of CO 2 and the coherent harmonic emission from the oriented molecules. The photoionization transition dipoles (PITDs) of CO 2 exhibit deep minima that change rapidly with molecular orientations accompanied by large phase changes of π in PITDs, thus leading to strong interference when the dipoles are added up coherently.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectral shaping of an ultrafast ytterbium fiber laser via a passive intracavity optical filter: a simple and reliable route to sub-45 fs pulses

We investigate the use of passive intracavity optical filters for controlling the laser output spectrum of a polarization-mode-locked, ultrafast ytterbium fiber laser. The overall lasing bandwidth is increased or extended by strategic choice of the filter cutoff frequency. Overall laser performance, including pulse compression and intensity noise, is investigated for both shortpass and longpass filters with a range of cutoff frequencies. The intracavity filter not only shapes the output spectra, but also provides a route for overall broader bandwidths and shorter pulses in ytterbium fiber lasers. These results demonstrate that spectral shaping with a passive filter is a useful tool to routinely achieve sub-45 fs pulse durations in ytterbium fiber lasers.

Cooper, Nicholas D.↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision control of laser energy for laser–matter interaction studies

Precise, highly reproducible control of the laser energy is required for high confidence laser–matter interaction research such as in dynamic compression science and high energy density physics. The energy must be adjustable without affecting the pulse shape (time varying intensity) or beam smoothness. We have developed a convenient two-stage energy tuning method for a nominal 100 J, 351 nm (UV) laser. The energy is adjusted in 10 J (10%) increments by operating the laser at full energy and inserting a beam splitter in the laser output. As the splitter is located after the final frequency tripling optics, the UV pulse shape is unchanged. The energy is varied by substituting a splitter of different reflectivity. For finer 3 J (3%) increments, the infrared pulse is attenuated inside the laser before the final amplifier. This requires modest tuning to preserve the pulse shape. The demonstrated variation in shot-to-shot reproducibility is less than +/–2.5 J (5% of the full energy), irrespective of the laser output energy. These approaches can be adapted to most ~100 J class lasers. We describe these techniques and show two examples where they have elucidated the underlying physics in laser shock compression experiments. One used only the beam splitters to establish the pressure for melting in iron. The other combined both techniques to finely increment the peak stress (~2 GPa steps) in germanium to precisely determine the onset and completion of melting—including the melting kinetics. Furthermore, these unambiguous results would not be possible without the developments described here.

47 OTHER INSTRUMENTATION↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Nonperturbative Field-Driven Vibronic Dynamics: Selective State Preparation and Nonlinear Spectroscopy

The partially linearized density matrix formalism for nonadiabatic dynamics is adapted to incorporate a classical external electromagentic field into the system Hamiltonian. This advancement encompasses the possibility of describing field-driven dynamics and computing a variety of linear and nonlinear spectroscopic signals beyond the perturbative limit. Here, the capabilities of the developed approach are demonstrated on a simple two-state vibronic model coupled to a bath, for which we (a) perform an exhaustive search in the field parameter space for optimal state preparation and (b) compute time-resolved transient absorption spectroscopy to monitor the effect of different pulse shapes on measurable experimental signals. While no restrictions on the form of the field have to be assumed, we focus here on Gaussian shaped (linearly) chirped pulses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Higher-order dispersion compensating pulse shaper via amplitude spectral filtering and nonlinear phase accumulation

A method of pulse shaping using spectral filtering, positive chirp, and self-phase modulation to control the accumulated higher-order phase terms of the spectral phase. This pulse shaping method has particular advantage in fiber chirped pulse amplification (FCPA) systems, where there are two effects: (1) an offsetting of the fourth order phase via nonlinear phase accumulation, allowing for a higher Strehl ratio (i.e., a cleaner pulse), higher peak power pulse and (2) enabling power scaling to higher pulse energies without the increased nonlinear phase accumulation leading to pulse breakup. This technique can be used both in a passive system with no amplification to clean up an existing pulse, and in an amplifier system to enable higher performance operation (shorter pulses, cleaner pulses, higher energy pulses).

Domingue, Scott R.↗

Direct density modulation of photo-assisted field emission from an RF cold cathode

This paper explores direct density modulation of high-current electron beam emission from an RF cold cathode using optical excitation. We theoretically study the photo-assisted field emission of periodically bunched electron beams of various pulse shapes under the combined excitation of an RF field and an optical field, using an exact quantum model. Both continuous-wave (CW) and pulsed optical fields are considered. The emission current pulse amplitude, pulse width, electron number density per pulse, as well as pulse shape and its harmonic contents are investigated in detail. For CW photon sources in the UV to NIR range (i.e., 200–1200 nm), increasing the optical intensity under an RF bias tends to change the current pulse from a Gaussian to sinusoidal-like shape, thus offering strong flexibility to control the frequency components in beam current emission. Pulsed photon sources combined with an RF field can produce sharp, high-current electron bunches with pulse duration comparable with or even less than that of the optical pulse. A contour map of the density modulation depth is constructed for different combinations of RF and laser fields. The results provide insight into unlocking new opportunities to achieve direct density modulation during electron current emission by optical means.

Physics↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra

Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate and detector-electronics-formed pulse shape then occur. Here, we focus on weak high energy tails in X-ray spectra, important for measurements on partially ionized, warm (50–500 eV average electron energy), pure hydrogen plasma. A first-principles two-photon pulse-pile-up model is derived specific to trapezoidal-shaped pulses; quantitative agreement is found between the measurements and the model’s predictions. The model is then used to diagnose pulse-pile-up tail artifacts and mitigate them in relatively low count-rate spectra.

2-photon↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Symmetric Rydberg controlled- Z gates with adiabatic pulses

We analyze neutral atom Rydberg C Z gates based on adiabatic pulses applied symmetrically to both atoms. Analysis with smooth pulse shapes and Cs atom parameters predicts the gates can create Bell states with fidelity F > 0.999 using adiabatic rapid passage (ARP) pulses. With globally optimized adiabatic pulse shapes, in a two-photon excitation process, we generate Bell states with fidelity F = 0.997. The analysis fully accounts for spontaneous emission from intermediate and Rydberg states, including the Rydberg lifetime in a room temperature environment, but does not include errors arising from laser noise. In conclusion, the gate protocols do not require individual addressing and are shown to be robust against Doppler shifts due to atomic motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

Low power on-chip data transmission for wafer-scale monolithic active pixel sensors

Here, this paper details the implementation of the digital pulse shaping subsystem within the Backbone Transmission Line Encoding (BTLE) driver, a low-power, long-distance on-chip data transmission solution designed in a 65 nm CMOS process. Digital pulse shaping is critical for minimizing inter-symbol interference (ISI) caused by bandwidth limitations of on-chip interconnects, especially in wafer-scale monolithic active pixel sensors (MAPS). A duobinary encoder coupled with a parallelized polyphase finite impulse response (FIR) filter is used for efficient shaping of the transmitted signal spectrum. This reconfigurable architecture achieves reliable 160 Mb/s data transfer over a 10 cm on-chip link, as validated by simulations demonstrating low power consumption (FoM 37.3 fJ/bit/mm of transmission line length) and effective ISI mitigation.

47 OTHER INSTRUMENTATION↗

Sample glue layer investigation and mitigation for laser induced prompt impulse experiments

Understanding longer timescale material reactions under dynamic stress loading is critical for applications in materials engineering, shock physics, and planetary science. Prompt impulse experiments generate lower pressures since the ablator—the material first removed by the laser—is thicker and farther from the diagnostic plane, capturing aggregate material responses from the initial shock wave, rarefaction waves, and later time effects. This complexity demands thorough material characterization and simulation support. Since traditional sample construction is specific to supported shock experiments, designing prompt impulse experiments requires reconsideration around target design and sample engineering. Here, we present sample preparation techniques, experimental investigations, and theoretical simulations to investigate glue layer impacts, aiming to standardize samples for consistent data at lower laser fluences. We find that glue layers <30 μm have a minimal impact on peak velocity and pulse shape. The peak velocity scales linearly with glue layer thickness until a glue layer of 75 μm. For glue layers >75 μm, the peak velocity no longer scales with thickness; however, the pulse shape continues to degrade as described by simulations.