Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulverized coal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

100 records · Page 6

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

CONVERSION OF COAL WASTES AND MUNICIPAL SOLIDS MIXTURES BY PYROLYSIS TORREFACTION AND ENTRAINED FLOW GASIFICATION

Hundreds of millions of tons of underutilized high-ash, low-energy-density bituminous and anthracite waste coal can be found in the U.S. These stockpiles contribute to water pollution from leaching that is harmful to waterways downstream of the piles. Conventional circulating fluidized combustion power plants use this coal to generate energy but emit toxic trace metals into groundwater (e.g., lead, mercury, arsenic). In addition, refuse-derived fuel (RDF) including municipal solid waste (MSW), biomass, waste plastics, and industrial waste are an enormous and untapped resource that is currently filling landfills or incinerated for low-quality energy with poor emissions. Mainstream Engineering has developed a combined pyrolysis torrefaction entrained flow gasification (PT-EFG) process that utilizes combined waste coal and RDF to create an alternative energy source, increasing energy independence and security and reducing the environmental burden from coal mines and processing facilities. Mainstream’s self-sustaining PT process converts RDF into feedstocks that can be pulverized and handled like conventional coal, enabling combined RDF-waste coal co-feeding into an EFG. The EFG operates at temperatures high enough to slag the ash completely, destroying any residual polycyclic aromatic hydrocarbons (PAHs), converting ash into nonporous vitrified slag or non-leachable ash, and generating high-hydrogen syngas for power generation or liquid fuels. During Phase II, Mainstream successfully demonstrated PT of biomass and MSW into a coal-like feedstock, which was co-gasified with waste coal in an EFG in a combined PT EFG process

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coal Fired Power Plant Configuration and Operation Impact on Plant Effluent Contaminants and Conditions

The primary objective of this project is to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. This project was in response to the U.S. Department of Energy (DOE) Solicitation DE-FOA-0001842. The project duration was between September 01, 2018, and December 31, 2021 (no-cost extension filed, due to the Covid-19 pandemic restrictions, and approved). Field and lab test program was conducted with the main goal to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. In this project, the team of Lehigh University (prime recipient) and Western Kentucky University identified two suitable Thermoelectric Power Plants (TTPs) firing bituminous and sub-bituminous coals respectively, designed test plans, and performed sample collection. Sampling included coal from each TTPs power generation units, Wet Flue Gas Desulfurization (WFGD) slurry material and waste-water samples taken from the outlet of the water treatment tank prior to discharge and other pertinent locations. Coal samples are dried, crushed, and pulverized according to the American Society for Testing and Materials (ASTM) methods. The prepared coal samples are analyzed for normal proximate and ultimate analysis tests in addition to the toxic metals and anions according to ASTM methods. The FGD slurry materials are analyzed for toxic metals and anions according to Electric Power Research Institute (EPRI) or Environmental Protection Agency (EPA) methods, as appropriate. The wastewater samples from the water treatment tank outlet are analyzed for toxic metals and anions according to EPA methods. The effluent species analyzed include mercury, arsenic, selenium, nitrate/nitrite, bromide, and chlorine. This project provided results of effluent conditions as a function of coal type, unit configuration, and unit operation profile, and identified the levels of uncertainty in the effluent results.

01 COAL, LIGNITE, AND PEAT↗

Development of coal-derived carbon-based structural unit as a potential new building material

Coal combustion for energy has not only wasted the hydrogen-rich volatile matters but also results in CO 2 emission causing serious environmental issues. An integrated coal pyrolysis and solvent extraction process under elevated temperatures in an inert atmosphere is implemented to convert as-mined coal from Wyoming Powder River Basin to functional carbon elements such as pyrolysis char (PC). This paper presents the development and fabrication of new carbon-based structural unit (CSU) using pulverized PC and two coal-derived pitches (mesophase pitch and tar pitch) to attain high compressive strength greater than 30 MPa, low thermal conductivity less than 0.30 W/m.K, and low density less than 1.25 g/cm 3 . CSUs have the potential to overcome the current challenges with cement and concrete through pressurized fabrication followed by carbonization. This study aims to develop CSU with nearly 100% coal-derived carbon material for structural application in buildings. The effects of pressing pressures, carbonization temperatures, and binder contents on the density and mechanical and thermal properties of CSU samples are investigated. The study concludes that mesophase pitch produces a better performance of CSU samples, a combination of 100 MPa pressing pressure and carbonization temperature of 900 ⁰C yields the highest compressive strength, and a 25% MP content is recommended for low-cost CSU fabrication. Furthermoer, CSU has a much lower density, lower thermal conductivity, higher compressive strength, and higher strength-to-density ratio than normal concrete.

36 MATERIALS SCIENCE↗

Coal Feed-Dependent Variation in Fly Ash Chemistry in a Single Pulverized-Combustion Unit

Four suites of fly ash, all generated at the same power plant, were selected for the study of the distribution of rare earth elements (REE). The fly ashes represented two runs of single-seam/single-mine coals and two runs of run-of-mine coals representing several coal seams from several mines. Plots of the upper continental crust-normalized REE, other parameters derived from the normalization, and the principal components analysis of the derived REE parameters (including the sum of the lanthanides plus yttrium and the ratio of the light to heavy REE) all demonstrated that the relatively rare earth-rich Fire Clay coal-derived fly ashes have a different REE distribution, with a greater concentration of REE with a relative dominance of the heavy REE, than the other fly ashes. Particularly with the Fire Clay coal-derived fly ashes, there is a systematic partitioning of the overall amount and distribution of the REE in the passage from the mechanical fly ash collection through to the last row of the electrostatic precipitator hoppers.

58 GEOSCIENCES↗

Removal of Iron from Pyrite-Rich Coal Refuse by Calcination and Magnetic Separation for Hydrometallurgical Extraction of Rare Earth Elements

In the metallurgical extraction of rare earth elements (REEs), the ratio of contaminant ions to REEs in the leachate dictates the cost and operational efficiency of the downstream processes. The current study investigated the potential iron contamination removal from the feed to the hydrometallurgical process by calcination followed by magnetic separation. The 2.20 specific gravity sink fraction of Baker coal seam coarse refuse was pulverized to finer than 180 μm, calcined at various temperatures, and separated into magnetic and non-magnetic fractions using a wet high-intensity magnetic separator at different field strengths. The untreated feed, calcined products, and their subsequent magnetic and non-magnetic fractions were subjected to acid leaching tests with 1.2 M sulfuric acid at 75 °C and 1% w/v solids concentration. The recovery of light and heavy rare earth elements (LREEs and HREEs, respectively) along with the concentration of common contaminant ions (Al, Ca, and Fe) were measured as output variables. The weight percent of magnetic material was maximized at approximately 29% by calcination at a temperature of 400 °C. Magnetic removal of this fraction using a field strength of 1.15 Tesla resulted in the rejection of 81% of the iron. Leaching of the magnetic fraction provided significantly higher Fe recovery relative to untreated feed material and the non-magnetic fraction. The non-magnetic fraction was subsequently calcined at 600 °C to dehydroxylate the clays and released the REE minerals in the same manner as the treatment of the original coarse refuse material. A comparison of the leachate elemental concentrations resulting from the leaching of both the calcined non-magnetic and original coarse refuse showed only a slight reduction in the iron content from the non-magnetic material. This finding combined with the REE loss in the magnetic fraction resulted in the conclusion that the magnetic removal step was unfavorable.

58 GEOSCIENCES↗

Plasma Ignition and Combustion Stabilization Technology to Improve Flexible Operation, Reliability and Economics of an Existing Coal-Fired Boiler

GE Steam Power, Inc. (GE) proposed to improve reliability, flexibility, and economics of an existing coal-fired power plant by applying a new advanced technology developed by GE, a plasma-assisted pulverized fuel firing system. The objective of this program is to demonstrate the achievement of lower load by improved flame stabilization and therefore lower operating costs in a full-scale field installation at coal-fired electric utility. GE’s Plasma Ignition and Combustion Stabilization System is designed to operate continuously to support low load operation. With the plasma on, the flame will be attached and stable, removing the firing system as a limitation to low load operation. In addition, GE’s exclusively from ABENZ company licensed AC based technology has a 90+% system efficiency compared to all other systems at which are DC and operate with ~75% efficiency. Plant operating costs are lowered by eliminating use of expensive support fuel as well as the ability to operate at lower loads. The utilities’ ability to better match the demand curve will result in significant savings. Maintenance is lower for an AC system than a DC system as it operates at lower current. This eliminates the need for a demineralized cooling water system and provides longer electrode life which translates into both material and labor savings. It is the objective of GE to not only demonstrate the additional low load achievable with a plasma system after best achievable tuning, sensor and software approach has been exhausted, but also the increased stability of the flame at all loads with plasma assistance as well as cost savings at all low loads using plasma instead of oil. Upon successful completion of this project, GE will have sufficient field experience to rapidly deploy the Plasma Technology. The project objectives were achieved through the implementation of plasma ignitor technology at PacifiCorp Hunter Station Unit 3. A plasma ignitor system was retrofitted on ten wall-fired burners, Mill 3-4 combustion system. The Plasma Ignitors installed at Hunter proved that this GE technology is a direct and complete replacement for the original oil ignitors. The Hunter Unit 3 burner management system allows the plasma system to be used in all applications that originally required oil to be burned. This includes any time the Mill 3-4 is started or stopped for any reason including boiler starts, load changes, and low load support.

01 COAL, LIGNITE, AND PEAT↗

Facile Synthesis of Micrometer-sized Hierarchical Porous Si@C Anodes for High-Performance Lithium-Ion Batteries

Extensive studies have been conducted to determine if replacing graphite anodes with silicon is feasible since silicon possesses a high capacity and is an abundant resource; however, Si anodes suffer significant volume changes during cycling, which pulverizes its structure and subsequently causes rapid capacity fading. We used SiO2 nanoparticles (nSiO2) and low-cost coal-derived humic acid as a feedstock to synthesize high performance Si-C anodes for Li-ion Batteries through spray drying, calcination, and magnesiothermic reductions. Our Si-C anodes features micrometer-sized porous Si coated with a graphitized carbon shell (mpSi@C). The hierarchical graphitized carbon shell and porous silicon structure relieve the mechanical stress of the Si phase upon cycling, which stabilizes the structure. This mpSi@C composite design allows for a high initial discharge capacity of 2199.9 mAh g-1 at 0.1 A g-1 and a cycling performance of 68% capacity retention after 100 cycles at 1.0 A g-1. The multipoint contact between the Si anode and C structure allows for a remarkable performance rate of 566.3 mAh g-1 at 5.0 A g-1.

01 COAL, LIGNITE, AND PEAT↗

Synthesis of hierarchical graphene coated porous Si anode for lithium-ion batteries

The ultra-high capacity and widespread availability of Si materials have resulted in them being the focus of extensive studies to replace the graphite anode. However, the main barriers preventing the Si anodes from large-scale applications are their huge volume change and severe interface reactions in the lithiation/delithiation process, which pulverizes its structure and subsequently deteriorates its cycle life. Here, micrometer-scale porous Si coated with graphene coating (mpSi@G) has been synthesized by using SiO 2 nanoparticles and novel coal-derived humic acid as feedstocks through a magnesiothermic reduction, followed by spray drying and calcination techniques. SEM, Raman, and X-ray absorption analysis demonstrate that the hierarchical graphene shell and micrometer-sized porous Si structure effectively release the Si anode's mechanical stress upon lithiation to achieve good structural stability. Here, the synthesized mpSi@G anode delivers a high initial lithiation capacity of 2974.9 mAh g –1 at 0.1 A g –1 with an initial coulombic efficiency of 70.2 %. Furthermore, the conductive hierarchical graphene network, along with the tight contacts of porous-Si and the graphene shell, contribute to a high capacity of 1109.5 mAh g –1 at a high current density of 5.0 A g –1 , showing excellent rate capability.

25 ENERGY STORAGE↗

Trace Element Sampling and Partitioning Modeling to Estimate Wastewater Composition and Treatment Performance at Coal Generators

The coal combusted at coal-fired power plants (CFPPs) contains several trace elements that impact human heath if released to the environment. Effective combinations of air pollution control devices (APCDs) and water pollution control devices (WPCDs) are critical to reducing these impacts. This work sampled pulverized CFPPs owned and operated by Louisville Gas & Electricity – Kentucky Utilities (LGE-KU) during baseload and cycling conditions. Next, an open-source and easy-to-implement trace element partitioning model was developed using publicly available datasets, literature studies of trace element partitioning, and sampling data to estimate trace element partitioning in APCDs to the gas, liquid, and solid phases exiting CFPPs. These estimates of the liquid phase trace element concentration in FGD wastewater were then used to estimate trace element behavior in WPCDs and evaluate treated wastewater effluent concentrations for compliance with the Effluent Limitation Guidelines (ELG) for the Steam Electric Generating Sector. Finally, cost estimates were developed for established and emerging wastewater treatment trains to identify the most cost-effective approaches for ELG compliance.

01 COAL, LIGNITE, AND PEAT↗