Search NASA⌕ Search

SEARCH · Search NASA

Results for “pumping test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Development of High Temperature (>700°C) Molten Salt Pump Technology for Generation 3 Solar Power Tower Systems

Bearings are required for long-shafted pumps historically used in concentrating solar thermal power applications. For molten chloride salts, bearings for such service conditions are not commercially available, nor has a design been demonstrated to work. Therefore, a project was sponsored by the Department of Energy’s Solar Energy Technologies Office for the development and demonstration of a submerged bearing for use in chloride salt pumps. This project’s tasks covered the tribological testing of candidate materials and the design, fabrication, testing, and post-test analysis of full-scale salt-compatible bearings. This work expands upon previous work. The effects of potential particulate in the salt were investigated through tribological bench testing. Through 11 tests, the MgO particulate size and concentration in a molten chloride salt were varied, and the effects on friction, wear rate, and wear characteristics were recorded. Novel journal bearings for chloride salt service were designed and fabricated based on these results. The bearings were of a relevant scale (i.e., for a 1.5 in. pump shaft) to demonstrate the technology with respect to further scale-up. The bearings were made of Haynes 244 and Yttria Partially Stabilized Zirconia. A custom bearing test rig, salt tanks, and associated infrastructure (e.g., heaters, tanks, transfer lines, gas flow control) were designed, procured, and installed. A few issues were encountered in the system fabrication process, resulting in delay of the project schedule. The system was successfully fabricated and assembled. Heating, cover gas, and pump motor systems were integrated into the control logic. This progress of the bearing test system represents a significant step forward towards demonstrating this promising technology. Nevertheless, the project ended before testing of the full-scale bearings could be performed.

14 SOLAR ENERGY↗

First operation and validation of simulations for the divertor cryo-vacuum pump in Wendelstein 7-X

Ten cryo-vacuum pumps (CVPs) were installed in the subdivertor region of each island divertor in the stellarator Wendelstein 7-X (W7-X) and operated for the first time during the recently completed plasma campaign OP2.1. A pumping speed of 70 ± 1 $\frac{m^3}{s}$ was measured during dedicated tests with known hydrogen gas injection. Based on a conductance model, the estimated pumping speed ranges from 86-93 $\frac{m^3}{s}$ for different sticking coefficients between 0.6 and 0.8. After completion of the initial tests the CVPs were operated successfully throughout the campaign, with regeneration performed once a week. Neutral gas pressures in the subdivertor in the range of 10 −4 mbar are well within the molecular flow regime and limit the particle exhaust capabilities of the CVPs. Simulations of the neutral gas pressure in the three-dimensional complex geometry of the subdivertor were performed using the DIVGAS code based on the direct simulation Monte Carlo method and a model implemented in the steady-state thermal package in ANSYS, which are in agreement with the measured values during plasma operation.

Cryo-vacuum pumping↗

Flow Sensor Test Article (F-STAr) - Water Testing and Commissioning Report for FY2024

Argonne National Laboratory’s Mechanism Engineering Test Loop (METL) facility is developing new experimental testing capabilities with the Flow Sensor Test Article (F-STAr). F-STAr’s mission is to provide high flowrate, sodium submersible testing capabilities to support the development of sodium cooled nuclear fission reactors. Figure 1 shows a model of F-STAr (left) and a photo of the partially assembled test article (right) with several of the main components labeled. The system currently includes a large pump with desired flowrates of up to 100 GPM; an immersion heater with a maximum power of 5 kW; an immersion cooler with an estimated maximum cooling power of 2 kW; and an experimental test section to support sub-test articles. Initially, F-STAr will be setup for testing flow sensors, specifically Eddy Current Flow Sensors (ECFS). However, the system can be reconfigured to support a wide range of testing needs. For example, F-STAr could be setup to complete testing of hydraulic components, heat exchangers, hydrodynamic bearings, seals, and more. This report will provide an update on the development of F-STAr with a focus on the water testing and commissioning activities during Fiscal Year 2024 (FY24). First, the report will focus on describing the pump development. Specifically, updates will be provided on troubleshooting the pump’s excessive vibrational issues. In addition to updates on the pump, pressure-flowrate performance testing in water will be described. Furthermore, updates will be provided on a pump shaft bushing development as well as rigging procedures. Future work and paths forward for F-STAr will be described. Finally, a short summary on the ECFS development will be described at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update

This report documents the quantitative results of the current industry-average performance for components and initiating events (IEs) at U.S. commercial nuclear power plants (NPPs). It represents the third update of the original analysis in NUREG/CR-6928 with data through 2020. Continuous characterization and updating of current industry-average performance with the latest industry data available are important steps in maintaining up-to-date risk models. Typically, data from 1998–2002 were used in NUREG/CR-6928, data from 1998–2010 in the first update, data from 1998–2015 in the second update, and data from 2006–2020 in this update, although many IEs required longer periods for adequate characterization of frequencies in all these analyses. As with NUREG/CR-6928 and previous updates, four types of events are covered in this report: component unreliability (e.g., a pump that fails to start or fails to run), component or train unavailability resulting from test or maintenance outages, special event probabilities covering operational issues (e.g., pump restarts and injection valve re-openings during unplanned demands), and IE frequencies. Results (in the form of beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models covering U.S. commercial NPPs.

99 GENERAL AND MISCELLANEOUS↗

“Max-tech FHR”: What is the maximum technically achievable water delivery capacity from a single 120 V plug?

Electrifying water heating will require affordable, direct drop-in replacements for existing gas water heaters that meet consumer expectations for hot water delivery. For many replacement scenarios, affordability requires a replacement option with like-for-like physical product dimensions, and existing consumer expectations presume a large delivery capacity from a small water heater. This work explores the technical potential for hot water delivery capacity for a heat pump water heater (HPWH) powered from a common 120 V plug. Delivery capability in this work is quantified by two metrics: the First Hour Rating (FHR) defined in the Code of Federal Regulations, and a real-world draw profile that resulted in hot water runout during field studies of 120 V HPWHs. The work focuses on the common “tall-and-slim” gas water heater product category, with external product dimensions of 20 inch diameter and 60 inch height. Using a simulation model in DOE/ORNL Heat Pump Design Model, validated by experimental baseline testing of a commercially available 120 V HPWH model, several measures were evaluated to maximize the delivery capacity of a 120 V HPWH. The 120 V HPWH was constrained by 1) external product dimensions of 20 in diameter and 60 inch height, 2) electrical power of 1.5 kW (85% of the available power from a dedicated 120 V, 15 A circuit), and 3) commercially-available components. The measures implemented included a large compressor, a pumped loop with plate heat exchanger to maximize tank stratification, enlarged heat exchangers, and relatively thin insulation to maximize the water storage volume.

Gluesenkamp, Kyle↗

High Temperature Ternary Chloride Molten Salt Pump

A ternary chloride (MgCl2-NaCl-KCl) molten salt pump has been developed to operate up to 720°C. The design is the result of a thermal, structural and material study of critical components. The vertical overhung pump incorporates first of a kind salt-wetted hydrodynamic bearings. Several bearing material pairings were tested which include: colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Oxygen Fuel (HVOF) coating. The coating withstands the corrosion effects of the molten salt, and is also used to protect a 316L stainless steel pump reservoir. The pump bowl assembly components are made of Inconel 625. A Nitrogen flushed carbon ring seal is used to keep salt vapors from interacting with external ambient air. Preliminary testing shows a promising pump design for use in the Concentrating Solar Power Gen 3 systems and sets the ground for further development of the HybrimetTM NiWC3b as a competitive alternative to available superalloys.

Handy-Cardenas, Lewis (ORCID:0009000744006972)↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Design, Construction, and Installation of In-Glovebox Pumped Actinide Molten Salt Loops

This report summarizes the work conducted in FY25 to construct and install pumped actinide-bearing molten salt loopsin a radiological glovebox. The establishment of such a capability will provide a platform in which technologies developed for Gen. IV molten salt reactors may be tested under relevant operating conditions. A review of convective molten salt systems is provided to frame Argonne’s pumped actinide loop relative to contemporary and historical systems. Moreover, the infrastructure needed to operate the system is detailed to provide additional context as to design metrics of the loops and supporting equipment. The pumps’ performance in water testing is outlined and used to inform operational activities planned in FY26. Finally, electrochemical experiments investigating fundamental reaction mechanisms governing reactive oxygen species that promote corrosion of molten salt media is also reported. In total, these combined loop installation and sensor development tasks will serve to aid in the future commercial deployment of molten salt reactors in the U.S.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial steady-state core simulation capability or thermal and pool-type molten salt reactors, coupling reactor physics, thermal-hydraulics, and evolving chemistry

This report presents the development and validation of an initial steady-state multiphysics capability for molten salt reactors (MSRs) under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in Fiscal Year 2025. The framework integrates neutronics, thermal-hydraulics, species transport, and thermochemistry to capture the coupled dynamics of liquid-fueled systems. Implementation and testing were performed on two representative designs: the Molten Salt Reactor Experiment (MSRE), a thermal-spectrum, channeled-flow reactor, and the Lotus Molten Salt Reactor (L-MSR), a fast-spectrum, pool-type reactor. The modeling suite employs Griffin for reactor physics and depletion, Pronghorn and SAM for thermal-hydraulics, Thermochimica for chemistry, and Saline for thermophysical properties, with benchmarking and validation carried out against historical MSRE data, experimental flow-loop measurements, and reference depletion calculations from Monte Carlo codes. The framework demonstrated the ability to reproduce key reactor behaviors including temperature feedback, reactivity losses, delayed neutron precursor transport, xenon poisoning, and redox potential evolution. The results confirm the feasibility and accuracy of the coupled models in predicting steady-state and selected transient MSR behaviors. This latter ones are used in this report as a proxy indicating that the steady-state models from which the transient starts are accurate. For MSRE, validation showed good agreement with pump start-up and natural circulation tests, while for the L-MSR, benchmarking confirmed hydraulic calibration and consistency of neutronics–thermal coupling. The tools also provided new insights into species transport, noble metal deposition, and salt solidification dynamics. On the Xenon transport front, the code is validated against the steady state Xenon poisoining measurement and showed good agreement with the experimental value. Identified areas for future work include advanced void transport modeling, three-dimensional simulations, improved alloy corrosion models, and tighter integration with high-fidelity Monte Carlo codes. These developments provide a foundation for high-fidelity MSR simulations that can support reactor design optimization, safety assessments, and long-term operational strategies.

42 - ENGINEERING↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and mate-rial selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Ox-ygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the salt, and is additionally used to protect a 316L stainless steel pump reservoir. The pump wetted components are made of Inconel 625, and it features a carbon ring seal developed by Flows-erve flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. This research showcases a promising design for use in the CSP Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys. Further work will further characterize the pump by performance & cycle testing in molten salt at higher temperatures.

14 SOLAR ENERGY↗

Stirring and peristaltic pumping alter flow electrode particle size and morphology

Flowable carbon-based electrodes are widely studied in electrochemical systems for energy storage and water treatment. Most laboratory- and pilot-scale studies employ active mixing for slurry preparation and handling and use peristaltic pumps for slurry circulation. Magnetic stirring is the most prevalent mixing method at the laboratory scale, and the combination of magnetic mixing and peristaltic pumping is favored for convenience and compatibility with particulate suspensions. However, these methods can strongly affect particle size and morphology (and therefore cell performance). In this study, we evaluate how mixing and pumping influence particle degradation in two commonly used carbon materials: spherical carbon black (CB) beads and powdered activated carbon (AC). We performed 24 h stirring-only experiments using magnetic, orbital, and overhead stirring. Separately, we conducted 32 h circulation experiments using a commercial peristaltic pump. Particle morphology and size were analyzed using optical microscopy and laser diffraction. The initially spherical CB beads (~580 μm, 1.5 wt%) exhibit rapid and extensive breakdown under both peristaltic pumping and magnetic stirring. By comparison, AC particles (initially ~31 μm) tested at 1.5 and 15 wt% showed measurable size reductions of up to ~25 % under either stirring or pumping. In conclusion, these findings highlight the need to account for and quantify morphological changes caused by both stirring and pumping in the design and associated evaluation of flowable electrode systems.

Chemistry↗

RENEWABLE MARINE-SOURCE INTEGRATED HEAT PUMP FOR SPACE CONDITIONING, WATER HEATING, AND FRESH WATER HARVESTING IN REMOTE COASTAL AND ISLAND COMMUNITIES

US coastal and island communities have vulnerable energy infrastructure and high energy costs, which are exacerbated by climate change. A unique opportunity exists to use thermal energy from year-round mild temperature variations to satisfy the broad energy needs of these communities. The US Department of Energy’s Oak Ridge National Laboratory designed a small-scale marine-source integrated heat pump (MS-IHP) that, as a single appliance, combines space conditioning, dehumidification (including fresh water harvesting from humid air), and water heating for home and commercial building applications in remote coastal and island communities. The unique, innovative features of the MS-IHP offer improved efficiency and substantially reduced costs for space conditioning, dehumidification, and water heating by seamlessly integrating a heat pump, heat pump water heater, and dehumidifier by using a single compressor; optimal year-round space cooling and heating, dehumidification, water harvesting, and water heating; and improved thermal comfort and reliable operation without frosting and defrosting because of the ocean’s warm temperatures and high heat capacity. Preliminary testing was conducted by retrofitting a commercial heat pump, demonstrating an outperformed performance compared with traditional air-source heat pumps. The MS-IHP technology can help decarbonize energy systems in remote coastal and island communities.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Smart Monitoring and Diagnostic System (SMDS) for Packaged Air Conditioners and Heat Pumps for Small/Medium Commercial Buildings: Preparation for Commercialization: CRADA 478 [Abstract only]

This project will enable Pacific Northwest National Laboratory (PNNL) and industry partner, mCloud Technologies, to work collaboratively to ready the Smart Monitoring and Diagnostic System (SMDS) for commercial deployment and validate its performance under real-world conditions at field sites. This project will specifically focus on 1) implementing the SMDS algorithms in a scalable cloud-based software architecture, 2) designing new, innovative, complimentary commercial services based on the SMDS, 3) enhancing the SMDS energy and cost impact algorithms to reduce uncertainty in estimates, 4) determining the lower limits on SMDS performance degradation detection, 5) validating algorithm performance and default values of adjustable thresholds with existing data from controlled physical testing and from customer packaged air conditioners and heat pumps (commonly referred to as rooftop units or RTUs), 6) field testing to validate the system on multiple customer buildings in diverse environments, and 7) expanding field deployment to a larger set of mCloud’s customer buildings. Project results by validating, enhancing, and quantifying the performance of the SMDS will position mCloud, and potential future licensees, to implement the SMDS in commercial offerings that encourage and enable use of condition-based and predictive maintenance, leading to significant reductions in energy use and greenhouse gas emissions associated with space conditioning by RTUs. Furthermore, these enhancements will increase the value of the SMDS for users and increase the potential market for its use and impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Root cause analysis of a molten salt pump in FLUSTFA

The primary salt pump installed in the high-temperature FLUoride Salt Test Facility (FLUSTFA) was successfully operated for some time, but later ceased operation. To understand what occurred, a Root Cause Analysis (RCA) was performed. Steps taken to try to get the pump operational include adjusting the shaft position, increasing the heating power of the tape heaters on the pump volute, and manually rotating the pump shaft. While removing the insulation, corrosion was noted on the outside of the pump volute, and decolorization of the insulation and tape heaters was observed. Significant corrosion products were also observed in the pump itself and the piping connected to the pump. The nitrogen cover gas was maintained from before salt was introduced into the loop until the pump was dismounted and continues to be maintained even after the pump was removed. After considering probable scenarios, causes were assigned and corrective actions were developed to prevent those causes. Then, the RCA was presented to an advisory committee for review, the “Review Committee,” consisting of experts in large molten salt systems: Brandon Haugh, David Holcomb, Kevin Robb, and Vicente Rojas. As a result, the advisory committee provided comprehensive feedback, which have been incorporated into a revised RCA. Findings have then been summarized and reported in this publication.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗