Real-time air quality monitoring in human habitat: the JPL electronic nose
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A light source directs ultraviolet light onto a test surface and a detector detects a current of photoelectrons generated by the light. The detector includes a collector which is positively biased with respect to the test surface. Quality is indicated based on the photoelectron current. The collector is then negatively biased to replace charges removed by the measurement of a nonconducting substrate to permit subsequent measurements. Also, the intensity of the ultraviolet light at a particular wavelength is monitored and the voltage of the light source varied to maintain the light a constant desired intensity. The light source is also cooled via a gas circulation system. If the test surface is an insulator, the surface is bombarded with ultraviolet light in the presence of an electron field to remove the majority of negative charges from the surface. The test surface is then exposed to an ion field until it possesses no net charge. The technique described above is then performed to assess quality.
Air pollution poses significant environmental, public health, and societal concerns in the Hindu Kush Himalaya (HKH) region of south-central Asia, notably during the dry monsoon months (~November to May). Key contributors to poor air quality include dust from the Middle East and western India, persistent nocturnal fog/smog, and biomass burning. To address this issue, we established a robust air quality and chemistry observation and modeling product suite utilizing multi-spectral red-green-blue (RGB) composite satellite products from Korea’s GEO-KOMPSAT-2A satellite, the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model for dust transport forecasts, and the Weather Research and Forecasting coupled with Chemistry (WRF-Chem) model to predict aerosols and chemical species concentrations. Our team employed similar RGB recipes transitioned by the NASA Short-term Prediction Research and Transition (SPoRT) Center for the GOES-R era products over the Western Hemisphere, with significant success in depicting dust and nocturnal fog / low clouds, and to a lesser extent smoke and fire hot spots. We will extend these capabilities for the HKH region by applying an artificial intelligence (AI) model that objectively identifies dust from multi-spectral satellite data over the Southwestern United States. The AI model will be calibrated for automated dust detection over HKH from GEO-KOMPSAT-2A satellite data, with a goal of developing a similar AI model for objectively identifying smoke as well. The ultimate goal of this effort is to enhance dust and smoke predictions in the region by establishing improved emission initializations in HYSPLIT and/or WRF-Chem through the automated AI detection of dust and smoke.
Scientists use satellite data for studying Earth's systems, and the remote sensing data that these satellites collect are typically separated into files of a size small enough for efficient network transfer and storage. However, researchers usually prefer to analyze the data based on real-world dimensions like time, space, or elevation. To help with this, NASA's Atmospheric Science Data Center (ASDC) developed a new cloud-based tool that combines these smaller data chunks into larger, more useful datasets. The tool works on Network Common Data Form (netCDF4) and some HDF5 formatted files, and it is available as a service in NASA's Earthdata Cloud. In this presentation, we showcase this service using data from the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument. By combining TEMPO's continuous observations over time, we create longer and more informative analysis-ready time series to facilitate the study of air quality patterns. Insights gained will provide a more comprehensive understanding of pollution sources, transport patterns, and their effects on the environment and human health.
The Nitrogen system is a vital utility supporting the curation office within NASA's Astromaterials Re-search and Exploration Science (ARES) Division at the Johnson Space center (JSC). Since the Apollo samples were returned in 1969. It has played an essential role in preserving NASA’s astromaterial collections (now nine collections) by maintaining contamination-free, controlled environments required for long term curation and advanced scientific research. To meet the stringent purity requirements for contamination control, high purity modified Grade C Liquid Nitrogen (LN2) is delivered weekly by an industrial gas vendor to a 15,000-gallon tank located outside at NASA JSC near the ARES facility. This nitrogen is vital for creating an inert atmosphere to store the collection in, ensuring they are continuously shielded from contaminants and alterations through a constant N2purge. For most of the past 65 years deliveries of LN2 have required a CoA (Certificate of Analysis) prior to delivery. If those were not available, then LN2 deliver were sent to third-party laboratories for verification, creating an operational bottleneck and quality gap. To address this challenge and maintain rigorous quality control, NASA JSC Infrastructure and Astromaterials Acquisition & Curation Office initiated the development of an on-site Analytical Gas Sampling (AGS) Laboratory. Designed to streamline quality verification if a CoA unavailable, the AGS lab was constructed by a subcontractor in Newton, NJ. After a successful factory acceptance test conducted by the NASA ARES Infrastructure team, the lab was trans-ported to NASA JSC, where it was anchored and integrated into the site’s nitrogen pressure system using stainless steel, oxygen-cleaned tubing. The ARES nitrogen system was modified to provide parallel flows to the AGS lab for quality control and to the astromaterials collection labs for maintaining an inert environment. The AGS lab features two operational modes: (1)Primary: Gaseous Nitrogen (GN2) Quality Monitoring –The AGS system continuously samples the site’s GN2 supply every 15 minutes to ensure compliance with required purity levels. (2) Secondary: LN2 Quality Verification when a comprehensive CoA is not available, a cryogenic vaporizer converts LN2 to GN2, which is then analyzed for impurities: H₂, Ar, O₂, CO, CO₂, H₂O, and total hydrocarbons (THC). By significantly enhancing on-site analytical capabilities, the AGS lab eliminates reliance on external testing, ensures uninterrupted quality monitoring of the nitrogen pressure system, and reinforces NASA’s commitment to preserving pristine astromaterials under the highest standards of curation and research integrity.
The Willwood Dam, an irrigation diversion dam located on the Shoshone River (Wyoming, USA), has faced ongoing issues with sediment accumulation and needs frequent sediment flushing to remain operable. However, high suspended sediment levels during flushing events have negatively impacted downstream aquatic ecology and recreational opportunities. To address these problems, DEVELOP partnered with the Wyoming Department of Environmental Quality, Shoshone River Partners, and United States Geologic Survey. During term one, the team developed a workflow to map turbidity using PlanetScope imagery, analyze time series precipitation data, and create landcover maps. For this term, we focused on three methods to gain a better understanding of sediment sources: 1) improving remote sensing of turbidity, 2) modeling sediment transport within the watershed using the Soil and Water Assessment Tool (SWAT), and 3) conducting a snow cover time series analysis using Suomi NPP VIIRS imagery. Through remote sensing, we found Dry Creek/Homesteader Creek and Penney Gulch/Rough Gulch had the highest concentration sediment plumes. The SWAT+ model created a high-resolution grid model of the watershed, identifying high sedimentation in the western and southern subbasins but displayed low-correlated calibration and validation results due to limited observed data. We analyzed the snow cover extent alongside other hydrologic variables and found that snow melt events correlated with increases in suspended sediment concentration and turbidity values. Coupling remote sensing with hydrological modeling will give watershed managers a new perspective on high-priority regions for implementation of remediation to reduce the sediment build-up at the Willwood Dam.
Measurements from the Earth Observing System (EOS) AURA mission will provide a unique perspective on air quality monitoring. Ozone, nitrogen dioxide, formaldehyde and aerosols from the Ozone Monitoring Instrument (OMI) and carbon monoxide from the Tropospheric Emission Spectrometer (TES) will be simultaneously measured with the spatial resolution and coverage needed for improving our understanding of air quality. AURA data products useful for air quality monitoring will be given.
Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.
Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.
Not Available
Not provided.
The emergence of Artificial Intelligence (AI) and Machine Learning (ML) methods may provide an alternative pathway to elicit the desired process-structure-property relationship. To achieve such relationship at an accelerated pace the use of data driven machine learning techniques are employed. This CRADA investigates the use and effectiveness of applying AI/ML techniques to a large dataset with the intention of creating a data-driven model that will predict processing parameters required to join lightweight materials at optimal performance.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
There are no author-identified significant results in this report.
There are no author-identified significant results in this report.
There are no author-identified significant results in this report.
Automated chemiluminescence and bioluminescence sensors were developed for the continuous monitoring of microbial levels in water supplies. The optimal chemical procedures were determined for the chemiluminescence system to achieve maximum sensitivity. By using hydrogen peroxide, reaction rate differentiation, ethylene diamine tetraacetic acid (EDTA), and carbon monoxide pretreatments, factors which cause interference were eliminated and specificity of the reaction for living and dead bacteria was greatly increased. By employing existing technology with some modifications, a sensitive and specific bioluminescent system was developed.