Vacuum Ultraviolet Radiation Desorption of Molecular Contaminants Deposited on Quartz Crystal Microbalances

Recent quartz crystal microbalance measurements made in the Marshall Space Flight Center, Photo-Deposition Facility, for several materials, recorded a significant loss of deposited contaminants when the deposition surface of the microbalance was illuminated by a deuterium lamp. These measurements differ from observations made by other investigators in which the rate of deposition increased significantly when the deposition surface was illuminated with vacuum ultraviolet radiation. These observations suggest that the accelerated deposition of molecular contaminants on optically sensitive surfaces is dependant upon the contaminant being deposited and must be addressed during the materials selection process by common material screening techniques.

Albyn, Keith↗

Development of a Space Irradiance Simulator for Advanced Studies and Materials Research

A lab-scale experimental apparatus that mimics the solar-thermal environment of space has recently been developed and tested at NASA Kennedy Space Center in support of novel materials research for future space science and exploration applications. The Space Irradiance Simulator (SIRS) apparatus exposes specimens up to roughly 61 mm in diameter to a similar thermal environment that exists at distances as close as 0.4 AU from the Sun. This includes a high vacuum environment, access to a deep cryogenic background temperature with optical properties that closely imitate a blackbody, and irradiance from a broadband solar “point” source at fluxes as high as 9300 W/m2. Cooling is provided by a Gifford-McMahon cryocooler capable of 25 W of cooling power at 20 K, with a base temperature of 14 K. A commercially available Xeon lamp acts as the solar source, creating broadband electromagnetic radiation with a spectrum similar to that of the Sun. Light is beamed through the vacuum chamber and onto a sample suspended within the cold-mass via a flexible quartz fiber bundle in conjunction with a custom vacuum feedthrough. The system design, fabrication, and operation are discussed; and results from the initial checkout testing of the system are presented.

A. M. Swanger↗

Visible and near-ultraviolet spectra of low-pressure rare-gas microwave discharges

The spectral emission characteristics of three commercial low pressure rare gas discharge lamps wire obtained in the near ultraviolet and visible wavelength range. All three lamps show a definite continuum over the entire wavelength range from 0.185 to 0.6 micrometers. Considerable line emission is superimposed on much of the continuum for wavelengths greater than 0.35 micrometers. These sources were used to make transmittance measurements on quartz samples in the near ultraviolet wavelength range.

Campbell, J. P.↗

Compact Microwave Mercury Ion Clock for Space Applications

We review progress in developing a small Hg ion clock for space operation based on breadboard ion-clock physics package where Hg ions are shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10(exp -13) at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required or holding 1-2x10(exp -13) at 1 second. We have completed an ion clock physics package designed to withstand vibration of launch and are currently building a approx. 1 kg engineering model for test. We also discuss frequency steering software algorithms that simultaneously measure ion signal size and lamp light output, useful for long term operation and self-optimization of microwave power and return engineering data.

navigation↗

Ice in space: An experimental and theoretical investigation

The thermodynamics of water ice formation was experimentally investigated under a wide variety of conditions, including those of outer space. This information, and in particular, the lifetime of ice particles as a function of solar distance is an absolute requirement for proper interpretation of photometric profiles of comets. The sublimation of ice particles in a nonequilibrium situation was studied. An oscillating fiber microbalance was used to measure the sublimation rate of water droplets (which were suspended on a long quartz fiber which was oscillating in a vacuum chamber). The influence of particle size, surface temperature, and the index refraction from simulated solar radiation were studied in relation to ice formation. Also examined was the influence of impurities (clathrates) on ice formation. Windows in the vacuum chamber allowed the ice particles to be exposed to a 1 kilowatt xenon arc lamp which was used to simulate solar radiation. Ice is proposed as a possible energy source for comets, as amorphous water ice and ammonia in low temperature and pressure environments demonstrated a clear energy release upon warming. Motion pictures of ice formation were taken and photographs are shown.

Patashnick, H.↗

Outgassing Measurements for Three Materials, Combined with Vacuum Ultraviolet Radiation Illumination of the Volatile Condensable Materials

The photolysis of three organic materials, by vacuum ultraviolet (VUV) radiation, has been quantified using 15-MHz temperature-controlled quartz microbalances (TQCM's). The rate at which molecular species, released from the individual samples, condensed on two TQCM s was measured for periods of up to 139.9-hours. The individual samples were heated in an effusion cell and the emitted molecular species collected on a pair of TQCM's which were maintained at -40 degrees Celsius. At several points during the deposition measurement, the deposition surface of one TQCM was illuminated by a 30 Watt deuterium lamp, and the loss of material from that surface was observed. V W illumination of the TQCM, concurrent with condensation, reduced the rate that material was lost from the deposition surface. These measurements present a contrasting picture of molecular deposition, in the presence of VUV, to that presented by other investigators who observed an enhanced rate of molecular deposition, when the deposition surface was illuminated by VUV.

Albyn, Keith↗