Generation of polarisation-nonuniform modes in a high-power CO{sub 2} laser

A method describing radially and azimuthally polarised laser modes is presented, which is devoid of intrinsic contradictions and unjustified restrictions. The solutions of the wave equation found in the paper satisfy Maxwell's equation bigtriangledownE = 0. This allowed the calculation of all the components of the fields of such modes, including the longitudinal one. Expressions for tight focusing of radially and azimuthally polarised modes are obtained in the Debye approximation. The methods of intracavity generation of such modes in a high-power industrial CO{sub 2} laser are experimentally realised and methods of mutual transformation of these modes outside the cavity are developed. The intracavity generation of azimuthally polarised modes was achieved by using as a rear highly reflecting mirror either V-shaped axicons or metal diffraction mirrors with the relief period comparable to the wavelength. Radially polarised radiation was generated by using diffraction mirrors with the relief period of the order of two wavelengths. The polarisation-nonuniform TEM{sub 01*} and TEM{sub 11*} modes of power up to 1.8 kW are generated for the first time. In this case, the degree of polarisation was close to 100% within the entire radiation power range both in the near- and far-field zones. By using two half-wave phase shifters, the azimuthally polarised radiation is transformed to radially polarised radiation and vice versa, the energy efficiency of this transformation being 92%. These results open up the possibility for industrial applications of such radiation. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron density distribution in {alpha}-iron: A {gamma}-ray diffraction study

High-accuracy single-crystal structure factors, complete up to sin {theta}/{lambda}=1.9 A ring {sup -1} have been measured from {alpha}-iron at 295 K using 316.5 keV gamma radiation. A detailed description of the electron density distribution is presented in terms of a multipolar atomic deformation model. The charge asphericity due to preferential occupancy of the t{sub 2g} subshell is much smaller than that reported hitherto from x-ray measurements but is in quantitative agreement with ab initio calculations, laying to rest discussions about failures of theory in reproducing the aspherical charge. The 3d{sup 7} electron distribution in the solid is contracted by 8.9% relative to the free atom. The atomic radial scattering factor deduced from {gamma}-ray diffraction is found to be in contradiction with earlier experimental and theoretical work. Achievement of a reliable Debye-Waller factor is of vital importance in this context. The directed metallic bonds are characterized by topological parameters at the bond critical points. Attention is paid to the 3d-4s occupation problem. A consistent interpretation of the 3d spin and charge form factors favors the occupation d{sup 7} in the metal as against d{sup 6} for the atom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ X-ray spatial profiling reveals uneven compression of electrode assemblies and steep lateral gradients in lithium-ion coin cells

Coin cells are used extensively as test devices in battery research for evaluation of new materials and optimization of cycling protocols. Here, in situ X-ray diffraction profilometry is used to characterize spatial distribution of the active materials, lithiation, and phase distribution in electrodes of NCM523/graphite coin cells. The X-ray data indicate uneven areal compression of the electrode assembly in such cells, which we trace to a specific design feature that leads to elastic deformation of a metal spacer. Steep lithiation gradients observed in the electrodes imply radially-dependent resistivity, for which uneven compression of the separator is a likely cause. Electrochemical model calculations suggest that variable porosity of the polymer separator would account for the salient features of spatial profiles observed in these coin cells.

25 ENERGY STORAGE↗

Through-Thickness Microstructure Characterization in a Centrifugally Cast Austenitic Stainless Steel Nuclear Reactor Primary Loop Pipe Using Time-of-Flight Neutron Diffraction

The US code of Federal Regulations mandates regular inspection of centrifugally cast austenitic stainless steel pipe, commonly used in primary cooling loops in light-water nuclear power plants. These pipes typically have a wall thickness of ~8 cm. Unfortunately, inspection using conventional ultrasonic techniques is not reliable as the microstructure strongly attenuates ultrasonic waves. Work is ongoing to simulate the behavior of acoustic waves in this microstructure and ultimately develop an acoustic inspection method for reactor inspections. In order to account for elastic anisotropy in the material, the texture in the steel was measured as a function of radial distance though the pipe wall. Experiments were conducted on two 10 × 12.7 × 80 mm radial sections of a cast pipe using neutron diffraction scans of 2 mm slices using the HIPPO time-of-flight neutron diffractometer at the Los Alamos Neutron Science Center (LANSCE, Los Alamos, NM, USA). Strong textures dominated by a small number of austenite grains with their (100) direction aligned in the radial direction of the pipe were observed. ODF analysis indicated that up to 70% of the probed volume was occupied by just three single-grain orientations, consistent with grain sizes of almost 1 cm. Texture and phase fraction of both ferrite and austenite phases were measured along the length of the samples. These results will inform the development of a more robust diagnostic tool for regular inspection of this material.

42 ENGINEERING↗

Machine learning-based interatomic potential development and phase transition analysis of ferroelectric hafnium dioxide

The ferroelectric phase (𝑃⁢𝑐⁢𝑎⁢2 1 , which is in orthorhombic symmetry) of hafnium dioxide (HfO 2 ) has gained much attention due to its potential applications in nanoelectronics and advanced memory devices. However, its complex phase behavior under external stimuli, such as pressure and temperature, remains a subject of intense investigation. This study focuses on developing a machine learning-based interatomic potential (MLIP) that is trained with data from density-functional theory (DFT) calculations to simulate phase transitions and mechanical properties of HfO 2 . The developed MLIP predicts lattice parameters, equations of state, bulk and shear moduli, and elastic constants that closely align with DFT predictions for several phases and at various pressures. Once validated, the MLIP is used to investigate the phase transitions of ferroelectric HfO 2 (𝑃⁢𝑐⁢𝑎⁢2 1 ) under both isobaric and constant stress conditions at elevated temperatures ranging from 200 to 2500 K. We used several complementary methods, including local symmetry identification, radial distribution function, and x-ray diffraction characterization, to identify interesting phase transitions among several competitive hafnia phases predicted from our simulations. The suggested methods uniformly reveal that under pure deviatoric condition, the system favors a transition from the orthorhombic 𝑃⁢𝑐⁢𝑎⁢2 1 phase to a tetragonal (𝑃⁢4 2 /𝑛⁢𝑚⁢𝑐) phase, whereas a zero stress condition drives the system from the 𝑃⁢𝑐⁢𝑎⁢2 1 phase to another orthorhombic (𝑃⁢𝑏⁢𝑐⁢𝑛) phase. These findings provide crucial insights into stress and temperature-induced phase behavior of hafnia, guiding future experimental and theoretical studies for optimizing hafnia-based ferroelectric devices.

Ferroelectric HfO2↗

Radiation forces of a highly focused radially polarized beam on spherical particles

A radially polarized beam focused by a high-numerical-aperture (NA) objective has a strong longitudinal and nonpropagating electric field in the focal region, which implies that it is suitable for axial optical trapping. In this paper, we use the vectorial diffraction integral to represent the field distribution of the radially polarized beam focused by a high-NA objective and then employ the T-matrix method to compute the radiation forces on spherical particles. Effects of different parameters, such as the size of the sphere, the inner radius of the radially polarized beam, and the NA of the objective, on the radiation forces are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabricating Radial Groove Gratings Using Projection Photolithography

Projection photolithography has been used as a fabrication method for radial grove gratings. Use of photolithographic method for diffraction grating fabrication represents the most significant breakthrough in grating technology in the last 60 years, since the introduction of holographic written gratings. Unlike traditional methods utilized for grating fabrication, this method has the advantage of producing complex diffractive groove contours that can be designed at pixel-by-pixel level, with pixel size currently at the level of 45 45 nm. Typical placement accuracy of the grating pixels is 10 nm over 30 nm. It is far superior to holographic, mechanically ruled or direct e-beam written gratings and results in high spatial coherence and low spectral cross-talk. Due to the smooth surface produced by reactive ion etch, such gratings have a low level of randomly scattered light. Also, due to high fidelity and good surface roughness, this method is ideally suited for fabrication of radial groove gratings. The projection mask is created using a laser writer. A single crystal silicon wafer is coated with photoresist, and then the projection mask, with its layer of photoresist, is exposed for patterning in a stepper or scanner. To develop the photoresist, the fabricator either removes the exposed areas (positive resist) of the unexposed areas (negative resist). Next, the patterned and developed photoresist silicon substrate is subjected to reactive ion etching. After this step, the substrate is cleaned. The projection mask is fabricated according to electronic design files that may be generated in GDS file format using any suitable CAD (computer-aided design) or other software program. Radial groove gratings in off-axis grazing angle of incidence mount are of special interest for x-ray spectroscopy, as they allow achieving higher spectral resolution for the same grating area and have lower alignment tolerances than traditional in-plane grating scheme. This is especially critical for NASA Constellation- X project that will utilize hundreds of gratings all of which need to be precisely aligned for x-ray observation of space.

Iazikov, Dmitri↗

Exclusive production of vector mesons in pp and pp-bar collisions

Protons and antiprotons at collider energies are a source of high energy Weizsaecker-Williams photons. This opens up a possibility to study at the LHC exclusive photoproduction of heavy vector mesons at energies much larger than possible at the HERA accelerator.We present selected results on the production of vector mesons {rho}, {omega}, {phi}, J/{Psi} and {Upsilon}. We show distributions in rapidity, transverse momentum of mesons and azimuthal angle between outgoing protons for RHIC, Tevatron and LHC energies. The absorption effects are discussed.The amplitude for {gamma}p{yields}Vp is calculated in a pQCD k{sub T}-factorization approach with an unintegrated gluon distribution constrained by inclusive deep-inelastic structure function. The total cross section for diffractive meson (virtual) photo-production as a function of energy and photon virtuality is calculated and compared to HERA data. We also discuss the ratio of the first radial excitation state (2S) to the ground state (1S) in diffractive J/{Psi} and {Upsilon} production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Innovative Compact Coronagraph Approach for Balloon-Borne Investigation of Temperature and Speed of Electrons in the Corona (BITSE)

We are developing an innovative compact coronagraph for studying the physical conditions in the solar wind acceleration region. This paper presents the new development of the compact coronagraph for the investigation of temperature and speed of electrons in the solar corona. The proposed compact coronagraph is a one stage externally occulted coronagraph without internal occulter or Lyot stop mask. The key of the new idea is to set the inner field cutoff at the External Occulter (EO) much smaller than the specified inner field cutoff. A second occulter on the surface of the detector array removes the remaining diffraction. The occulter on the detector surface functions similar to an internal occulter with the Inner Field of View Cutoff (IFoVC) exactly the same as specified. For BITSE, the desired inner field cutoff is 3 R, but the cutoff at EO is only 1.5 R☉. The diffraction analysis shows that in the sensor plane, the diffraction intensity at the 3 R☉ is not sensitive to the EO cutoff, either at 1.5 R☉ or close to 3 R☉. The advantage of having a smaller EO cutoff is that the vignetting decreased for the Field of View (FoV) near 3 R☉, therefore, the signal increases. Meanwhile, the diffraction of Point Spread Function is much less in the radial direction, which not only increases the image quality around 3 R☉, but also increases the encircled energy and signal to noise ratio. In other words, the data is useful right at 3 R☉! The BITSE optical design and diffraction analysis will be presented in detail. The simulation shows the signal to noise ratio obtained from the diffraction and vignetting data enables corona temperature and speed measurement.

Gong, Qian↗

Innovative Compact Coronagraph Approach for Balloon-Borne Investigation of Temperature and Speed of Electrons in the Corona (BITSE)

We are developing an innovative compact coronagraph for studying the physical conditions in the solar wind acceleration region. This paper presents the new development of the compact coronagraph for the investigation of temperature and speed of electrons in the solar corona. The proposed compact coronagraph is a one stage externally occulted coronagraph without internal occulter or Lyot stop mask. The key of the new idea is to set the inner field cutoff at the External Occulter (EO) much smaller than the specified inner field cutoff. A second occulter on the surface of the detector array removes the remaining diffraction. The occulter on the detector surface functions similar to an internal occulter with the Inner Field of View Cutoff (IFoVC) exactly the same as specified. For BITSE, the desired inner field cutoff is 3 R, but the cutoff at EO is only 1.5 R☉. The diffraction analysis shows that in the sensor plane, the diffraction intensity at the 3 R☉ is not sensitive to the EO cutoff, either at 1.5 R☉ or close to 3 R☉. The advantage of having a smaller EO cutoff is that the vignetting decreased for the Field of View (FoV) near 3 R☉, therefore, the signal increases. Meanwhile, the diffraction of Point Spread Function is much less in the radial direction, which not only increases the image quality around 3 R☉, but also increases the encircled energy and signal to noise ratio. In other words, the data is useful right at 3 R☉! The BITSE optical design and diffraction analysis will be presented in detail. The simulation shows the signal to noise ratio obtained from the diffraction and vignetting data enables corona temperature and speed measurement.

Gong, Qian↗

Static High Pressure X-Ray Diffraction of TI-6AL-4V

Ti-6Al-4V was examined under static-high pressure conditions using a diamond anvil cell. The angle-dispersive x-ray diffraction experiments were performed at the Advanced Photon Source, Argonne National Laboratory. Radial and axial geometry were used to examine multiple samples. The purpose of the experiment was to generate pressure-volume data at room temperature (which is non-existent in literature) and to examine deviatoric stress effects on such a hard alloy.

43 PARTICLE ACCELERATORS↗

The Radial Distribution Function (RDF) of Amorphous Selenium Obtained through the Vacuum Evaporator

After the amorphous selenium obtained through the vacuum evaporator, the relevant diffraction intensity is taken and its processing is made. Further on the interferential function is calculated and the radial density function is defined. For determining these functions are used two methods, which were compared with each other and finally are received results for amorphous selenium RDF.

36 MATERIALS SCIENCE↗

Laser beam induced nanoscale spot through nonlinear “thick” samples: A multi-layer thin lens self-focusing model

Self-focusing is a well-researched phenomenon. Nanoscale spots can be achieved through self-focusing, which is an alternative method for achieving high-density data storage, high-resolution light imaging, and maskless nanolithography. Several research groups have observed that self-focusing spots can be reduced to nanoscale levels via incident laser power manipulation. Self-focusing spots can be analyzed by solving the nonlinear Schrödinger equation and the finite difference time domain method. However, both procedures are complex and time-consuming. In the present work, a multi-layer thin-lens self-focusing model that considers diffraction effects and changes of refractive index along the radial and film thickness directions is proposed to analyze the self-focusing behavior and traveling process of light beams intuitively. The self-focusing behaviors of As{sub 2}S{sub 3} are simulated, and results show that a nanoscale self-focusing spot with a radius of about 0.12 μm can be formed at the bottom of nonlinear sample when the incident laser power exceeds 4.25 mW. Our findings are basically consistent with experimental reports and provide a good method for analyzing and understanding the self-focusing process. An appropriate application schematic design is also provided.

36 MATERIALS SCIENCE↗

Non-destructive testing of satellite nozzles made of carbon fibre ceramic matrix composite, C/SiC

Carbon fibre ceramic matrix composite materials, C/SiC, are excellent candidates as lightweight structural materials for high performance hot structures such as in aerospace applications. Satellite nozzles are manufactured from C/SiC, using, for instance, the Liquid Polymer Infiltration (LPI) process. In this article the applicability of different non-destructive analysis methods for the characterisation of C/SiC components will be discussed. By using synchrotron and neutron tomography it is possible to characterise the C/SiC material in each desired location or orientation. Synchrotron radiation using tomography on small samples with a resolution of 1.4 {mu}m, i.e. the fibre scale, was used to characterise three dimensionally fibre orientation and integrity, matrix homogeneity and dimensions and distributions of micro pores. Neutron radiation tomography with a resolution of about 300 {mu}m was used to analyse the over-all C/SiC satellite nozzle component with respect to the fibre content. The special solder connection of a C/SiC satellite nozzle to a metallic ring was also successfully analysed by neutron tomography. In addition, the residual stress state of a temperature tested satellite nozzle was analysed non-destructively in depth by neutron diffraction. The results revealed almost zero stress for the principal directions, radial, axial and tangential, which can be considered to be the principal directions.

36 MATERIALS SCIENCE↗

A novel nondestructive diagnostic method for mega-electron-volt ultrafast electron diffraction

Abstract A real-time, nondestructive, Bragg-diffracted electron beam energy, energy-spread and spatial-pointing jitter monitor is experimentally verified by encoding the electron beam energy and spatial-pointing jitter information into the mega-electron-volt ultrafast electron diffraction pattern. The shot-to-shot fluctuation of the diffraction pattern is then decomposed to two basic modes, i.e., the distance between the Bragg peaks as well as its variation (radial mode) and the overall lateral shift of the whole pattern (drift mode). Since these two modes are completely decoupled, the Bragg-diffraction method can simultaneously measure the shot-to-shot energy fluctuation from the radial mode with 2·10 −4 precision and spatial-pointing jitter from the drift mode having wide measurement span covering energy jitter range from 10 −4 to 10 −1 . The key advantage of this method is that it allows us to extract the electron beam energy spread concurrently with the ongoing experiment and enables online optimization of the electron beam especially for future high charge single-shot ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) experiments. Furthermore, real-time energy measurement enables the filtering process to remove off-energy shots, improving the resolution of time-resolved UED. As a result, this method can be applied to the entire UED user community, beyond the traditional electron beam diagnostics of accelerators used by accelerator physicists.

43 PARTICLE ACCELERATORS↗

Crystal Growth and Elemental Homogeneity of the Multicomponent Rare-Earth Garnet (Lu 1/6 Y 1/6 Ho 1/6 Dy 1/6 Tb 1/6 Gd 1/6 ) 3 Al 5 O 12

We report high-entropy aluminum garnets were grown as bulk single crystals using the micro-pulling-down method, taking the synthesis of complex ceramics a step further from the conventional preparation of polycrystalline materials. We studied the effects of growth parameters on the elemental distribution in high optical quality crystals of (Lu 1/6 Y 1/6 Ho 1/6 Dy 1/6 Tb 1/6 Gd 1/6 ) 3 Al 5 O 12 containing six cations (yttrium and rare-earths) taken in equimolar amounts. A single garnet structure was confirmed by powder X-ray diffraction. Electron microprobe measurements were obtained to correlate the radial distribution of rare-earth elements with pulling rates and molten zone height. The nature of the elemental distribution in the radial direction was associated with ionic radius: smaller rare-earths concentrated in the center of the crystal, while larger rare-earths segregated toward the outer edge of the cylindrical crystal. Faster pulling rates led to a flattening of the concentration profiles toward the nominal concentration, promoting a more homogeneous radial elemental distribution, while varying the molten zone height did not have a significant effect. The demonstrated success with crystal growth enables the practical availability of single crystals of multicomponent aluminum garnets for further discovery of new phenomena and applications.

36 MATERIALS SCIENCE↗

Coordination changes in liquid tin under shock compression determined using in situ femtosecond x-ray diffraction

Little is known regarding the liquid structure of materials compressed to extreme conditions, and even less is known about liquid structures undergoing rapid compression on nanosecond timescales. Here, we report on liquid structure factor and radial distribution function measurements of tin shock compressed to 84(19) GPa. High-quality, femtosecond x-ray diffraction measurements at the Linac Coherent Light Source were used to extract the liquid diffuse scattering signal. From the radial distribution function, we find that the structural evolution of the liquid with increasing pressure mimics the evolution of the solid phase. With increasing pressure, we find that the liquid structure evolves from a complex structure, with a low coordination number, to a simple liquid structure with a coordination number of ~12. We provide a pathway for future experiments to study liquids at elevated pressures using high-energy lasers to shock compress materials beyond the reach of static diamond anvil cell techniques.

X-ray diffraction↗

Effect of Collimation on Diffraction Signal-to-Background Ratios at a Neutron Diffractometer

High diffraction signal-to-background ratios (SBRs), the ratios of diffraction peak integrated intensity over its background intensity, are desired for a neutron diffractometer to acquire good statistics for diffraction pattern measurements and subsequent data analysis. For a given detector, while the diffraction peak signals primarily depend on the characteristics of neutron beam and sample coherent scattering, the background largely originates from the sample incoherent scattering and the scattering from the instrument space. In this work, we investigated the effect of collimation on neutron diffraction SBRs of Si powder measurements using one high-angle area detector bank coupled with six different collimation configurations in a large and complex instrument space at the engineering materials diffractometer VULCAN, SNS, ORNL. The results revealed that the diffraction SBRs can be significantly improved by a proper coarse collimator that leaves no gap between the detector and the collimator, and the improvement of SBRs by a fine radial collimator was remarkable with a proper coarse collimator in place but not distinguishable without one. It was also found that the diffraction SBRs were not effectively improved by adding neutron absorbing element boron to the fine radial collimator body, which indicates that either the absorption of secondary scattered neutrons by the added boron is insignificant or the collimator base material (resin and ABS) alone attenuates background scattering sufficiently. These findings could serve as a useful reference for diffractometer developers and/or operators to optimize their collimation to achieve higher diffraction SBRs.

Yu, Dunji↗