Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation source detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Radiant Temperature Nulling Radiometer

A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

Robert Ryan↗

Development of Gamma Background Radiation Digital Twin with Machine Learning Algorithms: Application of Unsupervised Machine Learning to Detection of Anomalies and Nuisances in Gamma Background Radiation Environmental Screening Data

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for development of a digital twin of gamma radiation background, and for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. In one segment of work, we developed a gamma background estimation model using a Longshort term memory (LSTM) network for one-step CPS time series prediction. The LSTM model was validated with two data sets of measurements from two independent NaI detectors positioned on a mobile platform. The data sets contained background radiation only and no orphan isotope sources. The LSTM model was constructed and tested using data from one of the detectors. Performance of the LSTM model was validate through one-step prediction of CPS time series of another NaI detector without re-training. This approach allows to create a digital twin for nuclear background estimation. Using LSTM, it could be possible to detect a source through subtraction of the estimated counts from the measured background. In another segment of work, we investigated detection of gamma emitting sources in the presence of complex background using unsupervised machine learning. Spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

54 ENVIRONMENTAL SCIENCES↗

The first energetic gamma-ray experiment telescope (EGRET) source catalog

In this catalog the results related to high-energy gamma-ray sources obtained from the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory are summarized for the period from 1991 April 22 to 1992 November 17, called phase 1. This phase of the Compton Observatory mission was devoted to an all-sky survey. Tables are included for the following EGRET results: solar flares with detected gamma radiation; pulsars; sources with absolute value of b is less than 10 deg, gamma-ray bursts; normal galaxies; clusters of galaxies; positive detections of radio-loud quasars and BL Lac objects; marginal detections of radio-loud quasars and BL Lac objects; upper limits for radio-loud quasars and BL Lac objects; upper limits for Seyfert galaxies and selected radio-quiet quasars, and other sources with absolute value of b is greater than or equal to 10 deg the Galactic plane. There is also a table relating the dates of the observations to the Compton Observatory viewing period numbers to assist in referencing the observations.

Fichtel, C. E.↗

Device for Detection of Explosives, Nuclear and Other Hazardous Materials in Luggage and Cargo Containers

Device for detection of explosives, radioactive and heavily shielded nuclear materials in luggage and cargo containers based on Nanosecond Neutron Analysis/Associated Particles Technique (NNA/APT) is under construction. Detection module consists of a small neutron generator with built-in position-sensitive detector of associated alpha-particles, and several scintillator-based gamma-ray detectors. Explosives and other hazardous chemicals are detected by analyzing secondary high-energy gamma-rays from reactions of fast neutrons with materials inside a container. The same gamma-ray detectors are used to detect unshielded radioactive and nuclear materials. An array of several neutron detectors is used to detect fast neutrons from induced fission of nuclear materials. Coincidence and timing analysis allows one to discriminate between fission neutrons and scattered probing neutrons. Mathematical modeling by MCNP5 and MCNP-PoliMi codes was used to estimate the sensitivity of the device and its optimal configuration. Comparison of the features of three gamma detector types--based on BGO, NaI and LaBr{sub 3} crystals is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waste Characterization Methods Based on Gamma-ray Imaging Spectrometers - 19454

Characterization of LLW, ILW, U, NORM and TENORM is critical to the nuclear industry's bottom line. Accurate measurements enable the disposal of waste at the lowest possible cost. In the past the most accurate technology available involved using HPGe detectors and extensive system modeling to estimate the total source term given what the user knows about the geometry of the source and any shielding between the source and the detectors. Now there are a variety of imaging detectors that are available commercially, including CZT and HPGe detectors that achieve energy resolution ≤1% FWHM at 662 keV. These devices couple the traditional high resolution spectroscopic analysis with next generation gamma-ray imaging information to more accurately characterize the radiation source term. Uncertainties in the source location will result in significant error in the characterization of an object's radioactivity. It is helpful if the object can be spun, such as a barrel, so that any asymmetry in the source distribution is averaged out from the detector's point of view. Even in the case of a spinning barrel it is important to determine if the radiation is concentrated near the center of the barrel or distributed near the edge. The closer one measures to a barrel, which usually dictates the time required to acquire data, the more these spatial variations in the source distribution will affect the calculated activity of each isotope. This paper will focus on showing the use of CZT imaging spectrometers to characterize complicated radiation source terms. The radiation images are used to determine where the source term should be defined in a radiation transport model that calculates the expected number of photopeak counts for each isotope detected. This is used to calculate the activity of the source. The transport model is used to determine the attenuation of the radiation source term through distance and shielding material, but the detection efficiency is based solely on radiation measurement data. These measurements are taken with a robotic source positioning device that allows for detailed directional efficiency calibration. It is a fully automated system where a detector is loaded into the device and all of the efficiency curves are captured as a function of direction by creating new measurements for each location the robot positions the source. These measurements are tagged with the true source location and the efficiency curve is calculated for each measurement. This is used to create a response function matrix as a function of energy and incident direction which is used to convert the direction dependent flux on the detector head determined from the simulation model to the expected number of counts per unit activity of each isotope of interest. The results of these source term reconstructions in both the spatial and spectral domain will be shown. The impact of improper specification of the source term will be shown for a few standard waste characterization scenarios to demonstrate the importance of proper source location determination. Finally, the underlying calibration method and some sample efficiency curves as a function of direction will be shown to demonstrate the importance of calibrating out directional response functions in imaging devices (which often have a strong forward sensitivity bias). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time Simultaneous 3D Volumetric Imaging and Mapping of Gamma-ray and Neutron Sources

The invention combines radiation detection instrumentation, data processing algorithms, and visualization software to enable, for the first time ever, simultaneous, real-time imaging of both gamma ray and neutron sources (fast and slow). Radiation detectors sensitive to gamma rays and neutrons are integrated with readout electronics that allow discriminated particles to be incorporated into real-time 3D volumetric reconstructions as two separate data streams. Using the Scene Data Fusion (SDF) conceptual framework and contextual sensors from the Localization and Mapping Platform (LAMP) developed at LBNL, gamma-ray and neutron data are fused onto contextual information from the environment around the detection system. The invention is compatible with radiation detection media capable of detecting and discriminating between gamma rays and neutrons or the pairing of multiple detectors separately capable of detecting gamma rays and/or neutrons. It can be integrated into a compact, lightweight imaging platform for operation as a hand-carry device, on unmanned aerial systems, and with unmanned vehicles. The ability to measure neutron enables the detection and 3D localization of shielded nuclear materials such as Pu-239 which is not possible with means of gamma-ray detection and spectroscopy overcoming of major limitation in the detection of such materials to-date.

Cates, Joshua↗

Nuclear-Reaction-Based Radiation Source For Explosives-And SNM-Detection In Massive Cargo

An automatic, nuclear-reaction-based, few-view transmission radiography method and system concept is presented, that will simultaneously detect small, operationally-relevant quantities of chemical explosives and special nuclear materials (SNM) in objects up to the size of LD-3 aviation containers. Detection of all threat materials is performed via the {sup 11}B(d,n+{gamma}) reaction on thick, isotopically-enriched targets; SNM are primarily detected via Dual Discrete-Energy Radiography (DDER), using 15.11 MeV and 4.43 MeV {sup 12}C{gamma}-rays, whereas explosives are primarily detected via Fast Neutron Resonance Radiography (FNRR), employing the broad-energy neutron spectra produced in a thick {sup 11}B-target. To achieve a reasonable throughput of {approx}20 containers per hour, ns-pulsed deuteron beam of the order of 0.5 mA intensity at energies of 5-7 MeV is required. As a first step towards optimizing parameters and sensitivities of an operational system, the 0 deg. spectra and yields of both {gamma}-rays and neutrons in this reaction have been measured up to E{sub d} = 6.65 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data acquisition and control software for XRD beamline at Indus-2

X-ray diffraction (XRD) beamline is under commissioning on Indus-2 synchrotron radiation facility. The experimental setup of XRD beamline consists of a six-circle diffractometer and various detector systems such as scintillation detector, ionization chamber and image plate. The diffractometer can be controlled via EIA232 serial interface or Ethernet. Standard data acquisition software with a graphical user interface has been developed using LabVIEW. A firm safety and error handling scheme is implemented for failsafe operation of the experimental station. This paper describes in detail the data acquisition and control software for the experimental station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Monte Carlo/Deterministic Methods for Accelerating Active Interrogation Modeling

The potential for smuggling special nuclear material (SNM) into the United States is a major concern to homeland security, so federal agencies are investigating a variety of preventive measures, including detection and interdiction of SNM during transport. One approach for SNM detection, called active interrogation, uses a radiation source, such as a beam of neutrons or photons, to scan cargo containers and detect the products of induced fissions. In realistic cargo transport scenarios, the process of inducing and detecting fissions in SNM is difficult due to the presence of various and potentially thick materials between the radiation source and the SNM, and the practical limitations on radiation source strength and detection capabilities. Therefore, computer simulations are being used, along with experimental measurements, in efforts to design effective active interrogation detection systems. The computer simulations mostly consist of simulating radiation transport from the source to the detector region(s). Although the Monte Carlo method is predominantly used for these simulations, difficulties persist related to calculating statistically meaningful detector responses in practical computing times, thereby limiting their usefulness for design and evaluation of practical active interrogation systems. In previous work, the benefits of hybrid methods that use the results of approximate deterministic transport calculations to accelerate high-fidelity Monte Carlo simulations have been demonstrated for source-detector type problems. In this work, the hybrid methods are applied and evaluated for three example active interrogation problems. Additionally, a new approach is presented that uses multiple goal-based importance functions depending on a particle s relevance to the ultimate goal of the simulation. Results from the examples demonstrate that the application of hybrid methods to active interrogation problems dramatically increases their calculational efficiency.

active interrogation↗

Virtual Gamma Ray Radiation Sources through Neutron Radiative Capture

The countrate response of a gamma spectrometry system from a neutron radiation source behind a plane of moderating material doped with a nuclide of a large radiative neutron capture cross-section exhibits a countrate response analogous to a gamma radiation source at the same position from the detector. Using a planar, surface area of the neutron moderating material exposed to the neutron radiation produces a larger area under the prompt gamma ray peak in the detector than a smaller area of dimensions relative to the active volume of the gamma detection system.

07 ISOTOPE AND RADIATION SOURCES↗

Wellbore detector with azimuthal and spectral energy resolution

A wellbore inspection device includes a radiation generation source operable to emit neutrons, and a radiation detector fixed relative to the radiation generation source and operable to detect backscattered neutron radiation from a surrounding environment. The radiation detector includes a plurality of individually addressable detector elements arranged in one or more concentric rings. Respective amounts of backscattered neutron radiation detected by the individually addressable detector elements within a ring is indicative of the azimuthal direction of the detected backscattered neutron radiation, and the respective amount of backscattered neutron radiation detected by the individually addressable detector elements of two or more concentric rings is indicative of an energy level of the backscattered neutron radiation. The inspection device determines whether a potential anomaly is present in or around the wellbore, based at least in part on the respective amounts of backscattered radiation detected by the individually addressable detector elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Detection in Gamma Spectra Using Hopfield Neural Network with B-SAT and Grover’s Algorithm on a Quantum Computing Simulator

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. In principle, gamma radiation sources can be detected and identified by their unique spectral lines. However, detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. In recent prior work, we have developed a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm to detect a weak signal anomaly hidden among the highly fluctuating background spectra. The objective of this work is to explore quantum computing methods to increase the speed of HNN. The approach is based on the Grover’s search algorithm in conjunction with a 3-SAT problem formalism. The Grover’s algorithm is implemented on a quantum computing simulator using Qiskit software. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign, where the anomaly is a subset of measurements containing a 137 Cs source. Results indicate that using Grover’s algorithm on a quantum simulator reduces runtime of HNN by two orders of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sensitivity enhancement of the gravitational detector OGRAN

The gravitational wave antenna OGRAN is installed in the underground laboratory of the Baksan Neutrino Observatory. At the present time, it has a limited sensitivity sufficient only to detect gravitational radiation from sources situated at a distance of about 100 kpc. The calculations presented in this paper demonstrate the increase in the sensitivity by two orders of magnitude with cooling of the acoustical resonator of the antenna to the liquid-nitrogen temperature. The possibility of using the same optical detection scheme as the one under room temperature is discussed. The revised construction of the cryogenic version of the OGRAN antenna is considered. The results of experiments carried out with the pilot model of cryogenic antenna are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Modeling and Design Optimization for a Next-Generation Unattended Sensor

We are developing a next-generation unattendedsensor that can detect and identify radiation sources while operating on battery power for several weeks. The system achieves smaller size and weight over systems that use NaI:Tl and 3He detectors by using a relatively new scintillator, Cs2LiYCl6:Ce:Ce (CLYC). This material can detect both gamma rays and thermal neutrons, has energy resolution of ~4% full width at half maximum at 662 keV, and allows for particle discrimination by pulse amplitude as well as pulse shape. The overall design features an array of sixteen CLYC detectors, each read out by a photomultiplier tube and custom pulse processing electronics. A field-programmable gate array analyzes the energy spectra using computationally efficient algorithms for anomaly detection.

McDonald, Benjamin S.↗

Use of information on the motion of spacecraft around the center of bodies in the undertaking of detecting sources of X-ray and gamma radiation

The problem of localizing sources of X-ray and gamma surges can be solved vis the installation of suitable monitors on several dispersed spacecraft. In this manner, determination of the coordinates of the source is possible only with the use of four spacecraft. In the case of the use of 3 or 2 spacecraft, it is necessary to use supplementary information. Data on the motion of a spacecraft around the center of a mass was used in the capacity of such information.

Eysmont, N. A.↗

Development of Hopfield Artificial Neural Network for Anomaly Detection in Environmental Gamma Radiation Background: Consortium on Nuclear Security Technologies (CONNECT) (Q2 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore supervised machine learning (ML) algorithms for development of a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm for detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of the Crab Pulsar and Nebula with the Fermi Large Area Telescope

The Crab Pulsar and Nebula are the remnants of the explosion of the supernova SN1054, which was observed by Chinese astronomers. Previously detected by EGRET, the Crab Pulsar and Nebula have been extensively observed in the gamma-ray energy band by the Large Area Telescope (LAT) onboard the Fermi satellite. The data collected by the LAT during its early operation stage have allowed a detailed measurement of the fluxes and of the energy spectra of both sources. The pulsar spectrum is consistent with the EGRET measurement in the region below 1 GeV and is well described by a power law with exponential cutoff at a few GeV. The nebula spectrum is well modeled by a sum of two power laws, identified respectively as the falling edge of the synchrotron and the rising edge of the inverse Compton components, and is in agreement with the observations from Earth-based telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Anomalies in Gamma Background Radiation Data with K-Means and Self-Organizing Map Clustering Algorithms (Consortium on Nuclear Security Technologies (CONNECT) Q1 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. The challenge is that spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

61 RADIATION PROTECTION AND DOSIMETRY↗