Search NASA⌕ Search

SEARCH · Search NASA

Results for “radio receivers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

92 records · Page 6

Relic neutrino decay solution to the excess radio background

Abstract The excess radio background detected by ARCADE 2 represents a puzzle within the standard cosmological model. There is no clear viable astrophysical solution, and therefore, it might indicate the presence of new physics. Radiative decays of a relic neutrino ν_i (either i=1, or i=2, or i=3) into a sterile neutrino ν_ s, assumed to be quasi-degenerate, provide a solution that currently evades all constraints posed by different cosmological observations and reproduces very well the ARCADE 2 data. We find a very good fit to the ARCADE 2 data with best fit values τ_i = 1.46 × 10^21 s and Δ m_i = 4.0 × 10^-5 eV, where τ_i is the lifetime and Δ m_i is the mass difference between the decaying active neutrino and the sterile neutrino. On the other hand, if relic neutrino decays do not explain ARCADE 2 data, then these place a stringent constraint Δ m_i^3/2τ_i ≳ 2 × 10^14 eV^3/2 s in the range 1.4 × 10^-5 eV<Δ m_i < 2.5 × 10^-4 eV. The solution also predicts a stronger 21 cm absorption global signal than the predicted one from the ΛCDM model, with a contrast brightness temperature T_21 = -238^+21_-20 mK (99% C.L.) at redshift z≃ 17. This is in mild tension with the even stronger signal found by the EDGES collaboration, T_21 = - 500^+200_-500 mK, suggesting that this might have been overestimated, possibly receiving a contribution from some unidentified foreground source.

Astronomy & Astrophysics↗

The Quantum Nature and Mass of the Neutrino. FY20 Annual Laboratory Continuation Progress Report

Over the last 100 years we have learned a much about the neutrino, but there remain interesting questions about this weakly interacting particle. In particular, at LLNL we are developing experiments to measure the mass and the quantum nature of the neutrino. The 2015 long range plan recommended tonne-scale neutrinoless double beta decay experiments as the top new project priority and this experiment will target the quantum nature of the neutrino. The LLNL team is motivated and focused on developing the best technology for this experiment which is a liquid xenon time project chamber called nEXO. On a longer time scale, LLNL is also developing technology to measure the neutrino mass with tritium decay experiments. Work on nEXO at LLNL started in 2015 with an LDRD and program development funds to develop the nEXO concept, publish sensitivity predictions, explore alternatives and risks, and to build a credible project team and this effort is on going. In addition, we received research funding from DOE-SC NP and LLNL manages pre-conceptual R&D for the nEXO collaboration a portion of which is executed at LLNL. The Project 8 effort is solely funded by LLNL LDRD, and ends this year. A second LDRD effort is focused on repurposing cyclotron radiation emission spectroscopy for eV-scale X-ray detection. This second effort, while separated from Project 8, still has scientific and technical commonalities with Project 8. The funding for this X-ray detection effort will continue for one more year. LLNL has a long history of building large projects, science projects and time projection chambers, but nEXO is in fact the first project of this scale that LLNL is prepared to lead for DOE-SC NP.We have the tools, skills, people and motivation to make nEXO a reality. The current program development dollars are used to prepare the nEXO concept for down select and CD1. These internal LLNL dollars pay for a number of things including project staff to organize the nEXO collaboration for the various reviews that lie ahead, to develop the draft plans and structure to manage the project as well as setting up an external advisory committee. The current LDRD is exploring alternatives that effect the risk profile as well as possible performance improvements. The DOE-SC NP base funding is targeted at simulation and analysis of the nEXO concept in preparation for the down select and refinement of the understanding of the detector as well as scientific effort on the large xenon test stand (LXTS) that will burn down one of the largest risks to the nEXO project. Lastly, LLNL is leading the pre-conceptual R&D effort and managing the funds for the nEXO collaboration. The results of this effort are reported elsewhere, but the scope of this executed at LLNL will be reported here and is primarily the engineering and construction of the LXTS experiment. The primary technical contribution of LLNL to the Project 8 concept is the formation and study of atomic tritium. Atomic tritium is necessary for Project 8 to reach the ultimate sensitivity. LLNL has considerable experience with tritium and is well suited for this crucial work. Although the focus of this work is strictly fundamental science, there has already been one significant spinoff to develop a new means to measure radio xenon in the air

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗