Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Imager-to-Radiometer In-flight Cross Calibration: RSP Radiometric Comparison with Airborne and Satellite Sensors

This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

calibrating↗

Lessons Learned from SMAP Radiometer Pre-/Post-launch Calibration

The Soil Moisture Active Passive(SMAP) mission was launched on 31stJanuary 2015 in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude to measure soil moisture and free/thaw globally [1]. The passive instrument of SMAP is a fully polarimetric L-band radiometer (1.4GHz) operating with a bandwidth of 24MHz. The radiometer uses a combination of noise-diodes and Dicke-loads for internal calibration with a design similar to that used by the Aquarius or Jason series radiometers[2,3].Pre-launch calibration activities had been performed since 2012on the engineering model of the radiometer. Post-launch calibration activities have been performed to fine-tune and validate the results from the pre-launch calibration. The major calibration activities and lessons learned in the past 8 years will be described in the following sections.

Jinzheng Peng↗

A test of water vapor radiometer-based troposphere calibration using VLBI observations on a 21-kilometer baseline

Simultaneous very long baseline interferometry (VLBI) and water vapor radiometer (WVR) measurements on a 21 km baseline showed that calibration by WVRs removed a significant fraction of the effect of tropospheric delay fluctuations for these experiments. From comparison of the residual delay variations within scans and between scans, the total tropospheric contribution t the delay residuals for each of the three 5 to 20 hour sessions was estimated as 1, 17, and 10%, with the first value being uncertain. The observed improvement in rms residual delay from WVR calibration during these three sessions was 4, 16, and 2%, respectively. The improvement is consistent with the estimated 2 to 3 mm path delay precision of current WVRs. The VLBI measurements, of natural radio sources, were conducted in April and May 1993 at Goldstone, California. Dual-frequency (2.3 and 8.4 GHz) observations were employed to remove the effects of charged particles from the data. Measurements with co-pointed WVRs, located within 50 m of the axis of each antenna, were performed to test the ability of the WVRs to calibrate line-of-sight path delays. Factors that made WVR performance assessment difficult included (1) the fact that the level of tropospheric fluctuations was smaller than is typical for Goldstone during these experiments and (2) VLBI delay variations on longer time scales (i.e., over multiple scans) contained uncalibrated instrumental effects (probably a result of slow temperature variations in the VLBI hardware) that were larger than the tropospheric effects.

Linfield, R. P.↗

Soil Moisture Active/Passive (SMAP) L-band Microwave Radiometer Post-Launch Calibration Revisit: Approach and Performance

The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM / 6 PM sun-synchronous orbit at 685-km altitude. After the SMAP L1B_TB data product version4was released in 2018, the radiometer has undergonefurther calibration and validation. The goal isto reducethe difference between antenna temperature (TA) ofascending and descending orbits during the eclipse, andto reduce the dips in the calibration drift over the Cold Sky (CS) during the eclipse seasons in 2017 and 2018. The post-launch calibration algorithmhas been revisitedby retrieving all of the calibration parameters simultaneouslywith two different options for thehot calibration source(theglobal ocean, or the radiometer internal reference load). The performance of the two options are compared here. Theoption with the radiometer internal reference load has been chosen by the SMAP science team for data release version 5. In addition, a correction offset is applied to the input signal to account for offsets during the early-mission stages with theSMAP SAR transmitter operating alongside the radiometer.

Jinzheng Peng↗

Calibrating Spaceborne Microwave Radiometers with GPS

Data from terrestrial GPS receivers are being used in growing numbers of applications requiring precise tropospheric sensing. One emerging application is the calibration of water vapor measurements from spaceborne microwave radiometers.

GPS Water Vapor Radiometers↗

An evaluation of water vapor radiometer data for calibration of the wet path delay in very long baseline interferometry experiments

The internal consistency of the baseline-length measurements derived from analysis of several independent VLBI experiments is an estimate of the measurement precision. The paper investigates whether the inclusion of water vapor radiometer (WVR) data as an absolute calibration of the propagation delay due to water vapor improves the precision of VLBI baseline-length measurements. The paper analyzes 28 International Radio Interferometric Surveying runs between June 1988 and January 1989; WVR measurements were made during each session. The addition of WVR data decreased the scatter of the length measurements of the baselines by 5-10 percent. The observed reduction in the scatter of the baseline lengths is less than what is expected from the behavior of the formal errors, which suggest that the baseline-length measurement precision should improve 10-20 percent if WVR data are included in the analysis. The discrepancy between the formal errors and the baseline-length results can be explained as the consequence of systematic errors in the dry-mapping function parameters, instrumental biases in the WVR and the barometer, or both.

Kuehn, C. E.↗

DSN water vapor radiometer: Tropospheric range delay calibration

A discussion is presented of the Deep Space Network water vapor radiometer by means of simultaneous antenna temperature and radiosonde measurements at Edwards Air Force Base. The calibration of radiometer gain and hot load radiometric noise temperature is also described. Calibration equations are given. It is found that with a selected data set, the RMS error is less than 1 cm over a total delay range of 9 to 38 cm. Limitations on the use of the water vapor radiometer are also given.

Slobin, S. D.↗

Calibration of Hurricane Imaging Radiometer C-Band Receivers

The laboratory calibration of airborne Hurricane Imaging Radiometer's C-Band multi-frequency receivers is described here. The method used to obtain the values of receiver frontend loss, internal cold load brightness temperature and injected noise diode temperature is presented along with the expected RMS uncertainty in the final calibration.

HURRICANE IMAGING RADIOMETER↗

Atmospheric simulator and calibration system for remote sensing radiometers

A system for calibrating the MAPS (measurement of air pollution from satellites) instruments was developed. The design of the system provides a capability for simulating a broad range of radiant energy source temperatures and a broad range of atmospheric pressures, temperatures, and pollutant concentrations for a single slab atmosphere. The system design and the system operation are described.

Holland, J. A.↗

Radiant Temperature Nulling Radiometer

A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

Robert Ryan↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Revisit: Approach and Performance

The soil moisture active passive (SMAP) microwave radiometer is a fully-polarimetric L -band radiometer flown on the SMAP satellite in a 6 AM /6 PM sun-synchronous orbit at 685-km altitude. After the SMAP L1B_TB data product version 4 was released in 2018, the radiometer has undergone further calibration and validation. The goal is to reduce the difference between antenna temperature of ascending and descending orbits during the eclipse, and to reduce the dips in the calibration drift over the cold sky (CS) during the eclipse seasons in 2017 and 2018. The postlaunch calibration algorithm has been revisited by retrieving all of the calibration parameters simultaneously with two different options for the hot calibration source (the global ocean, or the radiometer internal reference load). The performance of the two options are compared here. The option with the radiometer internal reference load has been chosen by the SMAP science team for data release version 5. In addition, a correction offset is applied to the input signal to account for offsets during the early-mission stages with the SMAP synthetic aperture radar transmitter operating alongside the radiometer.

calibration↗

Foreword to the Special Issue on the 11th Specialist Meeting on Microwave Radiometry and Remote Sensing Applications (MicroRad 2010)

The Specialist Meeting on Microwave Radiometry and Remote Sensing of the Environment (MicroRad 2010) was held in Washington, DC from March 1 to 4, 2010. The objective of MicroRad 2010 was to provide an open forum to report and discuss recent advances in the field of microwave radiometry, particularly with application to remote sensing of the environment. The meeting was highly successful, with more than 200 registrations representing 48 countries. There were 80 oral presentations and more than 100 posters. MicroRad has become a venue for the microwave radiometry community to present new research results, instrument designs, and applications to an audience that is conversant in these issues. The meeting was divided into 16 sessions (listed in order of presentation): 1) SMOS Mission; 2) Future Passive Microwave Remote Sensing Missions; 3) Theory and Physical Principles of Electromagnetic Models; 4) Field Experiment Results; 5) Soil Moisture and Vegetation; 6) Snow and Cryosphere; 7) Passive/Active Microwave Remote Sensing Synergy; 8) Oceans; 9) Atmospheric Sounding and Assimilation; 10) Clouds and Precipitation; 11) Instruments and Advanced Techniques I; 12) Instruments and Advanced Techniques II; 13) Cross Calibration of Satellite Radiometers; 14) Calibration Theory and Methodology; 15) New Technologies for Microwave Radiometry; 16) Radio Frequency Interference.

Le Vine, David M↗

Passive millimeter wave radiometer system for calibration of infrared cameras

An apparatus for accurate measurement of surface and sub-surface temperatures of an object from a distance without contacting the object is provided. Illustrative embodiments provide for simultaneous measurement of thermal emission and emissivity in the mm-wave regime thereby enabling real-time non-contact measurement of emissivity. Corrected temperatures for the object which may be used for calibration of infrared thermographic cameras are determined from the measurement of emissivity.

Murphy, Ryan D.↗

Aquarius's Instrument Science Data System (ISDS) Automated to Acquire, Process, Trend Data and Produce Radiometric System Assessment Reports

The Aquarius Radiometer, a subsystem of the Aquarius Instrument required a data acquisition ground system to support calibration and radiometer performance assessment. To support calibration and compose performance assessments, we developed an automated system which uploaded raw data to a ftp server and saved raw and processed data to a database. This paper details the overall functionalities of the Aquarius Instrument Science Data System (ISDS) and the individual electrical ground support equipment (EGSE) which produced data files that were infused into the ISDS. Real time EGSEs include an ICDS Simulator, Calibration GSE, Labview controlled power supply, and a chamber data acquisition system. ICDS Simulator serves as a test conductor primary workstation, collecting radiometer housekeeping (HK) and science data and passing commands and HK telemetry collection request to the radiometer. Calibration GSE (Radiometer Active Test Source) provides source choice from multiple targets for the radiometer external calibration. Power Supply GSE, controlled by labview, provides real time voltage and current monitoring of the radiometer. And finally the chamber data acquisition system produces data reflecting chamber vacuum pressure, thermistor temperatures, AVG and watts. Each GSE system produce text based data files every two to six minutes and automatically copies the data files to the Central Archiver PC. The Archiver PC stores the data files, schedules automated uploads of these files to an external FTP server, and accepts request to copy all data files to the ISDS for offline data processing and analysis. Aquarius Radiometer ISDS contains PHP and MATLab programs to parse, process and save all data to a MySQL database. Analysis tools (MATLab programs) in the ISDS system are capable of displaying radiometer science, telemetry and auxiliary data in near real time as well as performing data analysis and producing automated performance assessment reports of the Aquarius Radiometer.

Source record↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Upgrade

Current performance and existing problems in SMAP radiometer L1B_TB version 3 data product are described. The post-launch calibration algorithm has been updated by calibrating the three calibration parameters (the equivalent noise temperature of the noise diode, the offset of the reference load, and the antenna gain) jointly by using the global ocean and CS with both 110o and 180o pitch maneuvers after the reflector emissivity is calibrated. The results show that both calibration drift during eclipse season and bias over CS are removed. The RMSDs of the calibration drift over both the global ocean and CS are less than 0.1 K, and the goals of the calibration algorithm upgrade are achieved for coming L1B_TB version 4 data release.

Validation↗

Radiant Temperature Nulling Radiometer

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied. The underlying principle of nulling and self-calibration is the same as that of a typical microwave radiometer, but because of differences between the characteristics of signals in the infrared and microwave spectral regions, the principle must be implemented in a different way. A detailed description of the instrument including an infrared photodetector equipped with focusing input optics [e.g., lens(es) and/or mirrors] and an input LWIR band-pass filter is presented.

Source record↗

Towards Integrating Data Quality Assessments and Radiometer Uncertainty for Determining the Expanded Uncertainty of Three-Component Solar Radiation Measurements

Accurate solar irradiance data are fundamental for determining the design and performance characteristics of photovoltaic systems. The uncertainty of solar irradiance measurements depends on many factors including radiometer design, calibration, installation, maintenance, and operational environment. The key contributors to this uncertainty can be classified as the measurement uncertainty of a particular radiometer and the operational uncertainty determined for the time of measurement. Radiometer measurement uncertainty estimates (U R ) can be based on well-established methods used as part of the radiometer calibration process. Estimates of operational uncertainties (U o ) require consideration of additional site-specific factors that affect data quality. A method is needed for establishing the accuracy of solar irradiance data by integrating an existing data quality process and measurement uncertainty estimates for specific radiometers. An algorithm has been developed to integrate data quality analyses and measurement uncertainty estimates for three-component solar irradiance data: global horizontal (total hemispheric) irradiance, direct normal (beam) irradiance, and diffuse horizontal (sky) irradiance collected at one- to 60-minute intervals. The algorithm has been tested using one-minute irradiance measurements. The goal of the project is to distribute a user-friendly software package based on the new algorithm.

data integrity↗