Using DSCOVR EPIC as an Additional Calibration Reference to Radiometrically Scale the Geo Imagers for the NASA CERES Project

The NASA CERES project provides climate-quality observed TOA and calculated surface fluxes to the climate community. The CERES instruments are mounted on the Aqua, Terra, NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used alongside the VIIRS and MODIS based cloud properties necessary for converting CERES radiance observations into fluxes. The CERES SYN1deg product provides the regional hourly fluxes in between the Terra and Aqua/NOAA-20-CERES observations based on geostationary imager (GEO) radiances. The GEO radiances are radiometrically scaled to the MODIS or VIIRS calibration references. The GEO and MODIS inter-calibration events are limited by the Aqua-MODIS or VIIRS local equator crossing time of 1:30 PM. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth, and the Earth Polychromatic Imaging Camera (EPIC) instrument onboard DSCOVR has a constant view of the sunlit side of the Earth while taking images ranging from the UV to the NIR throughout the day. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that EPIC is radiometrically stable, which allows it to potentially be used as a transfer radiometer between imagers. This study will assess the viability of using EPIC as a consistent and stable calibration source for GEO imagers. EPIC will be inter-calibrated with Himawari-8 that has been radiometrically scaled with Aqua. The Himawari-8 based EPIC calibration gains will be verified by the EPIC calibration gains determined directly from Aqua-MODIS matches. The EPIC calibration gains based on Himawari-8 will be stratified by local time to determine any diurnal dependence of the GEO/EPIC calibration strategy.

C O Haney↗

(abstract) Radiometric Calibration of the Multi-angle Imaging Spectro-Radiometer

The EOS/MISR instrument has completed preflight calibration and characterization of its nine cameras. The radiometric calibration requirements includes absolute radiometric accuracy to 3 percent. To meet this challenging requirement MISR has employed detector based calibration methodology. The source, a 1.65 m integrating sphere, is spatially and spectrally featureless. Thus, when viewing scenes that are likewise homogeneous, the sensor incident radiance is easily retrieved to high accuracy. To enhance the radiance product for arbitrary scene types, however, MISR is planning to incorporate spectral out-of-band, point-spread function deconvolution, and pixel nonuniformity of response corrections. A summary of the preflight calibration is presented in this paper, as well as the error uncertainties for specific scene types with and without these processing corrections.

radiometric calibration EOS MISR↗

Validation of Landsat 7 ETM+ band 6 radiometric performance

Since shortly after launch the radiometric performance of band 6 of the ETM+ instrument on Landsat 7 has been evaluated using vicarious calbiration techniques for both land and water targets. This evaluation indicates the radiometric performance of band 6 has been both highly stable and accurate.

vicarious calibration↗

JPSS-1 VIIRS Radiometric Characterization and Calibration Based on Pre-Launch Testing

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 m. It is a cross-track scanning radiometer capable of providing global measurements twice daily, through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging and moderate bands, respectively. This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the government independent team to generate the at-launch baseline radiometric performance and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response-vs-scan (RVS), and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the VIIRS sensor specification and the SNPP VIIRS pre-launch performance.

VIIRS↗

JPSS-1 VIIRS Pre-Launch Radiometric Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument was designed to provide measurements of the globe twice daily. It is a wide-swath (3,040 kilometers) cross-track scanning radiometer with spatial resolutions of 370 and 740 meters at nadir for imaging and moderate bands, respectively. It covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands [0.412 microns to 12.01 microns]. VIIRS observations are used to generate 22 environmental data products (EDRs). This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the independent government team, to generate the at-launch baseline radiometric performance, and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field and stray light responses. A set of performance metrics generated during the pre-launch testing program will be compared to the SNPP VIIRS pre-launch performance.

RSB↗

Directional Reflectance Studies in Support of the Radiometric Calibration Test Site (RadCaTS) at Railroad Valley

The Radiometric Calibration Test Site (RadCaTS) is a suite of commercial and custom instruments used to make measurements of the surface reflectance and atmosphere throughout the day at Railroad Valley, Nevada. It was developed in response to the need for daily radiometric calibration data for the vast array of Earth-observing sensors on orbit, which is continuously increasing as more nations and private companies launch individual environmental satellites as well as large constellations. The current suite of instruments at RadCaTS includes five ground-viewing radiometers (GVRs), four of which view the surface in a nadir-viewing configuration. Many sensors such as those on Landsat-7 and Landsat-8 view Railroad Valley within 3° of nadir, while others such as those on Sentinel-2A and -2B, RapidEye, Aqua, Suomi NPP, and Terra can view Railroad Valley at off-nadir angles. Past efforts have shown that the surface bidirectional reflectance distribution function (BRDF) has minimal impact on vicarious calibration uncertainties for views <10°, but the desire to use larger view angles has prompted the effort to develop a BRDF correction for data from RadCaTS. The current work investigates the application of Railroad Valley BRDF data derived from a BRF camera developed at the University of Arizona in the 1990s (but is no longer in use) to the current RadCaTS surface reflectance measurements. Also investigated are early results from directional reflectance studies using a mobile spectro-goniometer system during a round-robin field campaign in 2018. This work describes the preliminary results, the effects on current measurements, and the approach for future measurements.

RadCalNet↗

Radiometric Degradation Curves for the ASTER VNIR Processing Using Vicarious and Lunar Calibrations

The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) onboard Terra platform, which was launched in 1999, has three separate subsystems: a visible and near-infrared (VNIR) radiometer, a shortwave-infrared radiometer, and a thermal-infrared radiometer. The ASTER VNIR bands have been radiometrically corrected for approximately 14 years by the sensor degradation curves estimated from the onboard calibrator according to the original calibration plan. However, this calibration by the onboard calibrator encountered a problem; specifically, it is inconsistent with the results of vicarious calibration and cross calibration. Therefore, the ASTER VNIR processing was applied by the radiometric degradation curves calculated from the results of three calibration approaches, i.e., the onboard calibrator, the vicarious calibration, and the cross calibration since February 2014. Even though the current degradation curves were revised, the inter-band and lunar calibrations show some inconsistencies owing to the different traceability in the bands by different calibration approaches. In this study, the current degradation curves and their problems are explained, and the new curves that are derived from the vicarious calibration with lunar calibration are discussed. The new degradation curves that have the same traceability in the bands will be used for future ASTER VNIR processing.

ASTER; Vicarious calibration; Lunar calibration; R↗

An Inter-Comparison Exercise of Sentinel-2 Radiometric Validations Assessed by Independent Expert Groups

Copernicus is the European Union's Earth Observation and Monitoring programme, delivering free access to operational and historical environmental data to support applications in a wide range of societal benefit areas. To allow meaningful long-term environmental monitoring and robust decision-making, it is essential to ensure that satellite-retrieved products are of high quality and consistency. This paper describes the outputs of an international workshop on the radiometric calibration validation of the Copernicus Sentinel-2A and Sentinel-2B Multi-Spectral Instrument. A wide range of vicarious methodologies have been applied independently and then compared per type of target. All methods agree on the good radiometric performance of both Sentinel-2A and Sentinel-2B with respect to the mission requirements as well as on evidence of a slight bias between the two instruments. Comparisons of all these results are discussed to highlight the benefits and advantages of the methods as well as to propose potential improvements either for the methods themselves and/or for the comparison exercise.

Sentinel-2↗

Digital correction of geometric and radiometric errors in ERTS data.

The sensor systems of the ERTS-A satellite are discussed and sources of geometric and radiometric errors in the received images are identified. Digital algorithms are presented for detection of reseau and ground control points, for rapid implementation of geometric corrections, and for radiometric correction of errors caused by shading, image motion, modulation transfer function, and quantum and systematic noise.

Bakis, R.↗

Effect of radiometric errors on accuracy of temperature-profile measurement by the spectral-scanning method.

The spectral-scanning method may be used to determine the temperature profile of a jet- or rocket-engine exhaust stream by measurements of gas radiation and transmittance at two or more wavelengths. A single, fixed line of sight is used, using immobile radiators and radiometers outside of the gas stream, and there is no interference with the flow. A given radiometric error causes an error in computed temperatures. The ratio between temperature error and radiometric error depends on profile shape, path length, temperature level, the strength of line absorption, and the absorption coefficient and its temperature coefficient. These influence the choice of wavelengths for any given gas. Conditions for minimum temperature error are derived. Numerical results are presented for a two wavelength measurement on a family of profiles that may be expected in a practical case of H2 - O2 combustion. Under favorable conditions, the fractional error in temperature approximates the fractional error in radiant-flux measurement.

Buchele, D. R.↗

Microwave radiometric systems.

Microwave radiometers measure thermal electromagnetic radiation at frequencies ranging over the entire radio spectrum, from audio to infrared. The temperatures of black-body radiators can be measured with sensitivities better than 0.01 K, and with absolute accuracies better than 0.5 K. Radiometric systems have been built with as many as 400 independent spectral channels. Frequency resolutions range from hertz to gigahertz; and integration times range from microseconds to hours. Radiometric systems have operated reliably on the ground, and in balloons, aircraft, and spacecraft, including the 1962 Mariner 2 planetary probe to Venus.

Barath, F. T.↗

The 90 GHz radiometric imaging

A 90-GHz (3 mm wavelength) radiometer with a noise output fluctuation of 0.22 K (RMS), with a scanning antenna beam mirror, and the data processing system are described. Real-time radiometric imaging of terrain and man-made objects are shown. Flying at an altitude of 1500 ft a radiometer antenna with a 2 degrees halfpower beamwidth can distinguish landforms, waterways, roads, runways, bridges, ships at sea and their wakes, aircraft on runways, and athletic fields. A flight taken at an altitude of 3000 ft with approximately 2000 ft of clouds below the radiometer demonstrates the ability to distinguish bridges, rivers, marshland and other landforms even though the clouds are optically opaque. The radiometric images of a few representative scenes along with photographs of the corresponding scenes are presented to demonstrate the resolution of the imager system.

King, H. E.↗

Microwave radiometric determination of wind speed at the surface of the ocean during BESEX

Microwave radiometric measurements were made at wavelengths ranging from 0.8 to 2.8 cm at altitudes from 0.16 to 11 km under well documented meteorological conditions over the Bering Sea. It is shown that determinations of wind speed at the ocean surface and liquid water content of the clouds may be made from such data. Determinations were made from two simultaneous but independent sets of radiometric measurements. The wind speeds and liquid water contents made from these two sets showed remarkable agreement. Independent estimates of these parameters made from in situ measurements showed reasonable agreement as well.

Wilheit, T. T., Jr.↗

An explication of the radiometric method for size and albedo determination

A radiometric model for determination of diameters, albedos, and temperatures of asteroids and other airless planets is presented. Integrated photometry of planets is reviewed, and attention is given to problems of stellar calibration, monochromatic corrections, and corrections for the temperature variations across the planetary sphere. A previous model, which assumes that an asteroid emits infrared radiation as a smooth sphere, is modified to account for observed sunward beaming of infrared emissions, apparently due to craters. In contrast to some studies of the lunar emission, the observable flux ratio between a cratered sphere and a smooth sphere is calculated for large ranges of wavelength, temperature, and phase angle. Revised diameters based on the crater model are given for 84 asteroids. The systematic discrepancy between radiometrically- and polarimetrically-obtained albedos is accounted for; further areas of disagreement between radiometry and polarimetry are discussed, and research to resolve them is suggested.

Hansen, O. L.↗

Investigation of thematic mapper spatial, radiometric, and spectral resolution

Low-altitude aircraft scanner data were employed in simulating the spatial resolution, radiometric sensitivity and spectral bandwidth parameters of the proposed Landsat Thematic Mapper (TM). The 30 to 40 m resolution of the TM was found to provide significant improvement over current Landsat resolution (50 to 60 m) in crop mensuration, especially for Western Europe and India where field sizes average from one to four hectares. In terms of radiometric sensitivity, a noise equivalent reflectance value of 0.5% was held to be necessary for discrimination of spectrally similar data; in addition, all of the six proposed TM spectral bands were shown to be necessary for monitoring at some point during the growing season.

Morgenstern, J. P.↗

Estimation of solar gravitational harmonics with Starprobe radiometric tracking data

The potential gravitational science return of a proposed spacecraft mission, called Starprobe, is investigated. The current mission plan is to place a spacecraft in a highly eccentric, highly inclined solar orbit with a perihelion distance of four solar radii. A covariance analysis based on Kalman filtering theory is performed to predict the accuracies with which gravitational parameters associated with the nonsphericity of the sun and relativistic effects can be estimated with radiometric tracking data. The accuracies are computed as functions of the quality and quantity of the radiometric data, the orbital parameters, the magnitude and character of the nongravitational accelerations acting on the spacecraft, and the errors in the tracking station locations and the ephemeris of the earth relative to the sun.

Mease, K. D.↗

A multi-frequency radiometric measurement of soil moisture content over bare and vegetated fields

A USDA Beltsville Agricultural Research Center site was used for an experiment in which soil moisture remote sensing over bare, grass, and alfalfa fields was conducted over a three-month period using 0.6 GHz, 1.4 GHz, and 10.6 GHz Dicke-type microwave radiometers mounted on mobile towers. Ground truth soil moisture content and ambient air and sil temperatures were obtained concurrently with the radiometric measurements. Biomass of the vegetation cover was sampled about once a week. Soil density for each of the three fields was measured several times during the course of the experiment. Results of the radiometric masurements confirm the frequency dependence of moisture sensing sensitivity reduction reported earlier. Observations over the bare, wet field show that the measured brightness temperature is lowest at 5.0 GHz and highest of 0.6 GHz frequency, a result contrary to expectation based on the estimated dielectric permittivity of soil water mixtures and current radiative transfer model in that frequency range.

Wang, J. R.↗