Search NASA⌕ Search

SEARCH · Search NASA

Results for “receiving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]↗

Incidence and predictors of loss to follow-up among adult patients receiving antiretroviral therapy in Central Ethiopia: a multi-center retrospective cohort study

Background: Globally, loss to follow-up (LTFU) remains a significant public health concern despite the rapid expansion of antiretroviral medication programs. It is a significant cause of treatment failure and threatens the enhancement of HIV treatment outcomes among patients on antiretroviral therapy (ART). However, there is a paucity of evidence on its incidence and predictors in Ethiopia. Thus, this study aimed to examine the incidence and predictors of LTFU among adult HIV patients receiving ART at hospitals in Central Ethiopia. Methods: A multi-centered facility-based retrospective cohort study was conducted among 432 randomly selected adult patients who received antiretroviral therapy. Data were entered into EpiData version 3.1 and exported to Stata version 14 for analysis. The Kaplan–Meier failure function was employed to determine the overall failure estimates, and the log-rank test was used to compare the probability of failure among the different categories of variables. The Cox proportional hazard model was used to identify independent predictors of LTFU. Results: Overall, 172 (39.8%) study participants were lost to follow-up over the 10-year follow-up period with an incidence rate of 8.12 (95% CI: 7.11, 9.09) per 1,000 person-months. Undisclosed HIV status (AHR: 1.96, 95% CI: 1.14, 3.36), not able to work (AHR: 1.84, 95% CI: 1.13, 2.22), opportunistic infections (AHR: 3.13, 95% CI: 2.17, 4.52), CD4 < 200 cell/mL (AHR: 1.95, 95% CI: 1.18, 3.21), not receiving isoniazid preventive therapy (IPT) (AHR: 2.57, 95% CI: 1.62, 4.06), not participating in clubs (AHR: 1.68, 95% CI: 1.10, 2.22), side effects of drugs (AHR: 1.44, 95% CI: 1.02, 2.04), and high viral load (AHR: 3.15, 95% CI: 1.81, 5.47) were identified as significant predictors of loss to follow-up. Conclusion: In this study, the incidence of LTFU was high. The focus should be on creating awareness and prevention programs that aim to reduce loss to follow-up by continuing counseling, especially on the negative effects of loss to follow-up and the benefits of ART care.

60 APPLIED LIFE SCIENCES↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

Particle Receiver Models for Systems Analysis

Particle receivers are gaining importance in the field of Concentrating Solar Power (CSP) due to the high temperature that particles can achieve without degradation. Several researchers are studying the potential of this technology by means of system analyses, which need simple and light models of the system. This study presents two simple models for the particle receiver. The simplest model is a correlation obtained by fitting the results calculated with a more complex receiver model simulated in CFD. The other model is a 1D model, which is benchmarked against the same CFD results. Although both models achieve high coefficient of determination, R2, when compared to CFD results, the 1D model seems to provide more accurate results (especially during sunsets and sunrises). Both models are integrated into a tecno-economic model developed in previous work. The LCOE obtained with the 1D model is between 7% and 10% greater than the one obtained with the correlation.

González-Portillo, Luis F. (ORCID:0000000348643825↗

Communication device, spread-spectrum receiver, and related method using normalized matched filter for improving signal-to-noise ratio in harsh environments

A communication device, a method of operating a communication device, and a spread-spectrum receiver are disclosed. The method includes receiving an incoming RF signal, demodulating the incoming RF signal to generate a baseband signal, filtering the baseband signal with a normalized matched filter having filter characteristics matched to a pulse-shaping filter of the transmitter that generated the incoming RF signal, and extracting a received signal from a normalized output generated by the normalized matched filter. As a result, interferences and noise from harsh environments may be suppressed.

42 ENGINEERING↗

Systems and methods for direct thermal receivers using near blackbody configurations

An aspect of the present disclosure is a receiver for receiving radiation from a heliostat array that includes at least one external panel configured to form an internal cavity and an open face. The open face is positioned substantially perpendicular to a longitudinal axis and forms an entrance to the internal cavity. The receiver also includes at least one internal panel positioned within the cavity and aligned substantially parallel to the longitudinal axis, and the at least one internal panel includes at least one channel configured to distribute a heat transfer medium.

14 SOLAR ENERGY↗

Power supply including a nonlinear transmission line that receives a single input pulse and outputs a plurality of pulses

Technologies pertaining to a power supply that includes a nonlinear transmission line are described herein. In an embodiment, a DC power supply comprises a pulsing circuit that receives a DC input and outputs a first plurality of pulses having a first frequency to a nonlinear transmission line. The nonlinear transmission line receives the first plurality of pulses and outputs a second plurality of pulses having a second frequency that is greater than the first frequency. The second plurality of pulses is then received at an amplifier/rectifier circuit that amplifies the second pulses to increase a voltage amplitude of the pulses, and rectifies the pulses to provide a substantially constant DC output.

42 ENGINEERING↗

Multi-stage falling particle receivers

The present disclosure is directed to multi-stage falling particle receivers and methods of falling particle heating. As the particles fall through the receiver, the particles are periodically collected and released by flow retarding devices. The periodic catch-and-release of the particles falling through the receiver reduces particle flow dispersion, increases particle opacity and solar absorption, and reduces erosion and damage to surfaces caused by direct particle impingement.

Ho, Clifford K.↗

Solar thermal receivers with multi-scale light trapping geometry and features

Solar receivers including a plurality of multi-scale solar absorbing surfaces arranged such that light or heat reflected from or emitted from one or more of the plurality of solar absorbing surfaces impinges one or more other solar absorbing surfaces of the solar receiver. The disclosed receivers increase the amount of absorbed energy from a concentrated light source, such as a heliostat field, and reduce radiative and convective heat losses.

Ho, Clifford K.↗

Bladed solar thermal receivers for concentrating solar power

A bladed solar thermal receiver for absorbing concentrated sunlight is disclosed. The receiver includes a plurality of panels arranged in a bladed configuration for absorbing sunlight. The bladed configurations can be radial or planar. The receiver design increases the effective solar absorptance and efficiency by providing a light trap for the incident solar radiation while reducing heat losses from radiation and convection.

Ho, Clifford K.↗

Wavelength control and monitor for dense wavelength division multiplexing (DWDM) silicon photonic receiver

Techniques and circuitry for wavelength monitor and control are disclosed herein. The disclosed wavelength monitor and control circuitry and techniques are designed to realize a multi-channel DWDM optical link by using a photonic receiver that dynamically adjusts resonant wavelengths of the microring drop filter (MDF), as needed. The wavelength monitor and control circuitry can monitor and control the resonant wavelengths of multiple MDFs for a DWDM silicon photonics receiver with minimum power and area overhead. In an embodiment, circuitry for an optical receiver comprises an MDF having resonant wavelength for multiple DWDM channels, and circuitry to control and monitor the resonant wavelength of the MDF in real-time and in manner that compensates for deviation between actual resonant wavelength of the MDF and the incident optical wavelength of the MDF.

Huang, Tsung Ching↗

Concentrated solar power generation using solar receivers

Inventive concentrated solar power systems using solar receivers, and related devices and methods, are generally described. Low pressure solar receivers are provided that function to convert solar radiation energy to thermal energy of a working fluid, e.g., a working fluid of a power generation or thermal storage system. In some embodiments, low pressure solar receivers are provided herein that are useful in conjunction with gas turbine based power generation systems.

Anderson, Bruce N.↗

The design and test results of A Giga-Bit Cable Receiver (GBCR) for the ATLAS Inner Tracker Pixel Detector

This paper presents the design and test results of a Gigabit Cable Receiver ASIC called GBCR for the HL-LHC upgrade of the ATLAS Inner Tracker (ITk) pixel detector. Three prototypes (GBCR1, GBCR2, and GBCR3) have been designed in the CERN-identified 65 nm CMOS technology. GBCR receives seven (GBCR2) or six (GBCR3) channels (RX) each at 1.28 Gbps from the front-end readout chip RD53B via flex cables up to 1 meter and Twinax cables up to 5 meters and sends the equalized and retimed signals to lpGBT. Both GBCR2 and GBCR3 ASICs have two transmitting channels (TX) that pre-emphasize the signals from lpGBT before sending them to RD53B through the same cables. No Single-Event Upset (SEU) is observed in any tested channels of GBCR2 in a 400 MeV proton beam. The extrapolated bit error rate for the future HL-LHC application is below 8*10^(-16), significantly below the specified BER criterion. GBCR3 is designed to improve the immunity to single-event-upset by applying the Triple Modular Redundancy (TMR) technology to all RX channels. The retimed signals from GBCR3 have less total jitter than those from GBCR2 (35 ps versus 79 ps). Each receiver channel of GBCR3 consumes 75% more power than that of GBCR2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-stage falling particle receivers

The present disclosure is directed to multi-stage falling particle receivers and methods of falling particle heating. As the particles fall through the receiver, the particles are periodically collected and released by flow retarding devices. The periodic catch-and-release of the particles falling through the receiver reduces particle flow dispersion, increases particle opacity and solar absorption, and reduces erosion and damage to surfaces caused by direct particle impingement.

Ho, Clifford K.↗

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, M. R. [Fermilab; Chicago U., KICP]↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for Concentrating Solar Receiver Applications

Supported by an award from the Solar Technology Office, US Department of Energy, GE Aerospace Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR). We report the results of our study of the effective heat transfer characteristic of several candidate structure motifs, or feature geometries, made of SiC via additive manufacturing in a simulative laboratory test. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. The solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply radiative heating power on one face of 2”-diameter cylindrical feature specimens representing the structure motifs of interest for receiver element design. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions.

14 SOLAR ENERGY↗

A Proof for the Unbiased Nature of Range-Doppler Measurements in Coarse-Resolution Dechirp-on-Receive Feedback Synthetic Aperture Radar Navigation

In feedback synthetic aperture radar (SAR) navigation, observables extracted from SAR range-Doppler images correct position and velocity errors accumulated within an associated navigation system. Unlike most other sensors, which produce measurements without input from a navigation system, SARs require a prior estimate of the radar’s position and velocity to adjust the radar’s matched filter during range-Doppler image formation. Consequently, it is possible for position and velocity errors within a navigation system to manifest as additional errors (biases) in the range-Doppler measurement observables. Prior work has not tackled this possibility in the context of feedback SAR navigation with a dechirp-on-receive radar. This paper offers a proof demonstrating that range-Doppler observables extracted from coarse-resolution vertical SAR images formed with a dechirp-on-receive radar may be safely modeled as unbiased measurements of the radar’s true position and velocity despite the presence of moderate navigation errors.

dechirp-on-receive↗

Qualitative and quantitative profiles of jejunal oligosaccharides and cecal short–chain fatty acids in broiler chickens receiving different dietary levels of fiber, protein and exogenous enzymes

Dietary supplemental carbohydrases are able to degrade non-starch polysaccharides and generate oligosaccharides in the gastrointestinal tract. This study was conducted to investigate the influence of dietary fiber and protein levels on growth performance, nutrient utilization, digesta oligosaccharides profile and cecal short-chain fatty acid (SCFA) profile in broilers receiving diets supplemented with xylanase or protease individually or in combination. Enzyme supplementation had no effect on growth performance. There was significant (P < 0.05) fiber × protein × xylanase interaction for ileal nitrogen digestibility and significant (P < 0.01) protein × xylanase × protease interaction for nitrogen-corrected apparent metabolizable energy. Birds fed high-fiber diets had higher (P < 0.05) jejunal oligosaccharides and cecal SCFA concentrations. Xylanase and protease combination produced the greatest pentose (Pent) levels in low fiber–adequate protein diets but lowest levels in highfiber–low protein diets. There was significant (P < 0.05) fiber × xylanase × protease interaction explained by the digesta concentrations of (Pent) 3 , (Pent) 4 and (Pent) 5 being greatest (P < 0.5) in protease-only supplemented high-fiber diets but lowest in protease-only supplemented low-fiber diets. Furthermore, these results suggest that, of all the factors investigated, dietary fiber level had the greatest effect on modulating digesta concentration of oligosaccharides and cecal SCFA. Evidence points to the fact that there is considerable capacity for generating pentose oligosaccharides in the digestive tract of broilers receiving diets rich in fibrous feedstuffs, and that this may have a beneficial effect on microbial profile in the digestive tract.

59 BASIC BIOLOGICAL SCIENCES↗