Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Portable Electromyograph

A portable electronic apparatus records electromyographic (EMG) signals in as many as 16 channels at a sampling rate of 1,024 Hz in each channel. The apparatus (see figure) includes 16 differential EMG electrodes (each electrode corresponding to one channel) with cables and attachment hardware, reference electrodes, an input/output-and-power-adapter unit, a 16-bit analog-to-digital converter, and a hand-held computer that contains a removable 256-MB flash memory card. When all 16 EMG electrodes are in use, full-bandwidth data can be recorded in each channel for as long as 8 hours. The apparatus is powered by a battery and is small enough that it can be carried in a waist pouch. The computer is equipped with a small screen that can be used to display the incoming signals on each channel. Amplitude and time adjustments of this display can be made easily by use of touch buttons on the screen. The user can also set up a data-acquisition schedule to conform to experimental protocols or to manage battery energy and memory efficiently. Once the EMG data have been recorded, the flash memory card is removed from the EMG apparatus and placed in a flash-memory- card-reading external drive unit connected to a personal computer (PC). The PC can then read the data recorded in the 16 channels. Preferably, before further analysis, the data should be stored in the hard drive of the PC. The data files are opened and viewed on the PC by use of special- purpose software. The software for operation of the apparatus resides in a random-access memory (RAM), with backup power supplied by a small internal lithium cell. A backup copy of this software resides on the flash memory card. In the event of loss of both main and backup battery power and consequent loss of this software, the backup copy can be used to restore the RAM copy after power has been restored. Accessories for this device are also available. These include goniometers, accelerometers, foot switches, and force gauges.

De Luca, Gianluca↗

A portable hypergolic oxidizer vapor sensor for NASA's Space Shuttle program

The design and performance characteristics of an electrochemical NO2 sensor selected by NASA for the space shuttle program is described. The instrument consists of a sample pump, an electrochemical cell, and control and display electronics. The pump pushes the sample through the electrochemical cell where the vapors are analyzed and an output proportional to the NO2 concentration is produced. The output is displayed on a panel meter, and is also available at a recorder jack. The electrochemical cell is made up of a polypropylene chamber covered with teflon membrane faceplates. Plantinum electrodes are bonded to the faceplates, and the sensing and counter electrodes are potentiostatically controlled at -200 mV with respect to the reference electrode. The cell is filled with electrolyte, consisting of 13.5 cc of 23% solution of KOH.

Helms, W. R.↗

Methods—A Practical Approach to the Reversible Hydrogen Electrode Scale

Accurately quantifying applied potential is important to ensuring the comparability, accuracy, and precision of electrochemical studies. Reference electrodes (REs) enable knowledge/determination of the applied potential at electrodes in electrochemical systems. Ultimately, the choice of RE will depend on the particular requirements of a given electrochemical system, however, we note it is imperative to ensure the accuracy of the RE potential and its proper translation to a standardized scale. In this work, we highlight that while there are many commercially available REs, these must be experimentally calibrated to a reliable and practical standard potential scale, for instance the reversible hydrogen electrode (RHE) scale for aqueous systems. With representative data, we provide streamlined instructions on how to calibrate any RE to the RHE scale. We also provide guidance to mitigate and/or avoid possible electrolyte contamination issues arising from REs. Moreover, we offer a step-by-step guide on how to build a practical RHE RE, which may be a suitable and desirable option in certain applications. Our work emphasizes the need for the continuous adoption of standardized reference potential scales and demonstrates the versatility of the RHE scale, particularly in aqueous electrochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study directed at development of an implantable biotelemetry ion detector

A literature search was conducted to currently update known information in the field of ion-selective electrodes. The review attempts to identify present trends in cation and anions selective electrodes pertinent to the area of bioimplantable units. An electronic circuit was designed to provide the high impedance interface between the ion-selective sensors and signal-processing equipment. The resulting design emphasized the need for low power and miniaturization. Many of the circuits were constructed and used to evaluate the ion-selective electrodes. A cuvette capable of holding the ion-selective and the reference electrodes was designed and constructed. This equipment was used to evaluate commercially available ion-selective electrodes and the electrodes designed and constructed in the study. The results of the electrode tests are included.

Hanley, L. D.↗

Alternate cathodes for sodium-metal chloride batteries

Various metal chlorides were tested as possible cathode materials for sodium-metal batteries (in addition to Fe and Ni chlorides, which have been already developed to a stage of commercialization), using an electrochemical cell consisting of a pyrex tube, heated to 250 C, with the metal wire as working electrode, concentric Ni foil as counterelectrode, and high-purity Al as reference electrode. In particular, the aim of this study was to identify metal chlorides insoluble even in neutral melts, possible at the interface during overcharge, in order to eliminate the failure mode of the cell through a cationic exchange of the dissolved metal ions with sodium beta-double-prime alumina solid electrolyte. Results indicate that Mo and Co are likely alternatives to FeCl2 and NiCl2 cathodes in sodium batteries. The open circuit voltages of Na/CoCl(x) and Na/MoCl(x) cells at 250 C would be 2.55 V and 2.64 V, respectively.

Ratnakumar, B. V.↗

Sensing and arresting metal corrosion in molten chloride salts at 800 degrees Celsius

Originally this was planned as a 5 task, 3 year project, starting in May 2019. Task 1 Detecting oxidants and metal corrosion in molten chloride salt at 800°C. Task 2 Effectiveness of Zr getter using head gas sensors of inlet and outlet gases. Task 3 Cathodic protection of metal in molten salt at reducing potential. Task 4 Find reduction potential of metals in molten chloride salts & quantum modeling. Task 5 Develop corrosion test sections integrated into molten salt flow loop. After Q4, the project was scaled back and the reorganized SOPO was reduced to 3 tasks to be completed at the end of Q7 on 01/05/2021. The 3 SOPO tasks are: Task 1 Sense oxidants and the metal corrosion in molten Na-K-Mg-Cl salt at 800°C. Task 3 Cathodically protect H230 alloy in molten Na-K-Mg-Cl salt at 800C by making H230 alloy the cathode of a power supply with a chromium-rich-metal as the anode. Task 4 Find the reduction potential of Cr metal in molten Na-K-Mg-Cl salt at 800°C. The total timeline was reduced from 12 to 7 quarters with the end date being, January 5, 2021. This amounted to task 1,3 and 4 being done in Q5,6 and 7 of an extended year 1, ending on January 5, 2021. Task 1, 3 and 4 were completed. For task1) the increase of oxidants in molten salt is detected by two things: i) a positive shift of the electrode potential for a Haynes 230 alloy (H230) metal coupon versus a silver/silver-chloride reference electrode (SSE) and ii) an increase in the corrosion rate of a H230 electrode at 800C. For task 3) applying a cathodic potential (negative overpotential) to a H230 electrode versus SSE arrested the corrosion of the cathodically protected H230 compared to an unprotected “spectator H230 electrode” in the same molten chloride salt. Lastly, for task 4) the reduction potential of chrome and chrome rich, and nickel metal electrodes were measured. The most valuable outcome of this work is that a power supply can arrest metal corrosion for metal in molten chloride salt when the power supply applies a cathodic potential to bare metal, like H230, in molten chloride salts, like ternary Mg-K-Na-chloride salt. H230 is a high strength metal for containing molten chloride salt and ternary Mg-K-Na-chloride salt is used as heat transfer fluids in concentrating solar power plants. When to use cathodic protection for protecting metal in molten chloride salts? Two scenarios are envisioned: 1) for protecting high-valued components, like solar collectors and heat exchangers and 2) for protecting the bare surface in holidays (point defects) of corrosion inhibitors that are to intended to cover the entire surface of metal.

14 SOLAR ENERGY↗

The Effect of Electrolyte Composition on Lithium Plating During Low Temperature Charging of Li-Ion Cells

In the present work, a number of additives have been investigated for their effect on the charge characteristics of cells containing low temperature, high ester content electrolytes (1.0 M LiPF6 in ethylene carbonate (EC) + ethyl methyl carbonate (EMC) + methyl propionate (MP) 20:20:60 vol % + X additive). These experimental three-electrode cells are composed of graphite anodes, LiNiCoAlO2 cathodes, and a lithium metal reference electrode. Cells were first subjected to electrochemical characterization at various temperatures, consisting of performing Electrochemical Impedance Spectroscopy (EIS), linear micropolarization and Tafel polarization measurement to determine the kinetic parameters for both the anodes and cathodes. Following electrochemical characterization, the cells were subjected to charging at decreasing temperatures using C/5 rates to 4.10V, with a constant potential C/50 current taper. Analysis of the C/20 discharge following the charge at low temperature revealed either the presence or absence of a high voltage plateau during the initial stages of the discharge. This plateau has been linked to the presence of lithium metal on the anode previously and was used as a measure for the extent of lithium plating in the cell. Differential analysis (dV/dQ) was applied as well to more clearly visualize the position of the high voltage plateau and use the peak position (x-axis) in the dV/dQ plot as a gauge for the amount of plating which took place in the cell on the prior charge. Most additives investigated increased the resistance of the anode and decreased the resistance of the cathode, thereby leading to an overall increase in plating observed at low temperature. One additive, LiFSI, was found to be beneficial during low temperature charging, however studies of electrode kinetics from the cell containing LiFSI did not reveal significant improvements compared to the baseline.

Jones, John-Paul↗

Precious metal oxygen-evolving anodes for electrolytic reduction of metal oxides in molten LiCl-Li 2 O electrolyte

Understanding the electrochemical stability of oxygen-evolving anode materials in molten salt electrolytes is essential to enable decarbonized electrolytic reduction of metal oxides (e.g., used nuclear oxide fuels). Here, this work investigated three precious metals (Ir, Ru, and Pt) as oxygen-evolving anodes in molten LiCl-Li 2 O (99.0-1.0 wt%) at 650 °C. For consistent measurements, this work employed a three-electrode cell comprised of a two-phase Li-Bi (65-35 at%) reference electrode and a NiO counter electrode. Anodic polarization behavior of each anode was investigated via cyclic voltammetry (CV) and chronoamperometry. The onset potential for oxygen evolution was observed at E > 2.9 V (vs. Li/Li + ) for the Ir and Ru anodes and anodic current density was as high as 1.0 A cm -2 at 3.23 V. The dimensional stability of each anode was evaluated from long-term electrolysis experiments (10.0-32.1 h) at 3.23 V. Rapid consumption of the Pt anode was observed after the application of 26,453 C cm -2 with a reduction in diameter of about 15.8% due to the formation of a non-protective Li 2 PtO 3 compound. The formation of this compound was also observed during CV measurements as additional anodic waves at potentials more negative than that of oxygen evolution. In contrast, both the Ir and Ru anodes exhibited excellent dimensional stability with a reduction in diameter or thickness of less than 1.5% even after applying greater charge density of ~41,100 C cm -2 , demonstrating superior stability during oxygen evolution in the LiCl-Li 2 O electrolyte.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Guide to Nonaqueous Electrochemistry of f-Element Complexes

Electrochemistry is a powerful tool for assessing and understanding the redox chemistry of molecular complexes. Cyclic voltammetry enables the f-element community to study molecules in unusually high or low oxidation states, which potentially pose important broad-scope questions of electronic structure. In the pursuit of boundary-pushing compounds, reactive air- and moisture-sensitive species are often encountered, which can be challenging to characterize, especially when they are chemically incompatible with certain solvents, electrolytes, or electrodes or when their potentials lie outside of common electrochemical windows. Nonaqueous solvents and pseudo reference electrodes complicate many of the standard practices in acquiring high-quality and reproducible electrochemical data. This guide presents a detailed discussion of selecting appropriate cell conditions and referencing and addresses metrics for evaluating electrochemical and chemical reversibility. These methodological approaches have been extended to best practices for the electrochemical analysis of radioactive transuranic complexes.

Electrodes↗

Electrochemical Reactivity of Hydrogen Storage Materials: Exploring Borohydride and Hydrazinium Salt Mixtures

Electrochemical characterization of hydrogen storage materials was conducted in a non-aqueous environment to investigate the direct electrochemical release and consumption of hydrogen and the potential for regeneration. We first address the challenge of minimal solubility of the synthetic precursors, sodium borohydride (NaBH 4 ) and hydrazinium bromide (N 2 H 5 Br), in both organic and inorganic solvents. We next determine and calibrate a reference electrode formulation compatible with our non-aqueous media and analytes that demonstrates a stable reference potential. We employ cyclic voltammetry (CV) to characterize the precursors and mixtures thereof. Each CV peak is assigned to a corresponding electrochemical reaction. Using the rate-dependent CV method and Randles–Ševčík equation, we calculate the diffusion coefficient of each chemical (NaBH 4 and N 2 H 5 Br). Analysis of the CVs, coupled with 11B NMR analysis, reveals a room temperature chemical transformation of NaBH 4 and N 2 H 5 Br mixtures into hydrazine borane (N 2 H 4 BH 3 ). These results are particularly significant, considering the limited information available on the electrochemical characterization of metal borohydride and hydrazinium salt in non-aqueous media. This work establishes a foundation for adapting a non-aqueous electrochemical system to further study the borohydride family of chemistries and to design and develop electrochemical devices for direct electrical and chemical energy interconversion with hydrogen storage materials.

08 HYDROGEN↗

Challenges in selecting appropriate electrodes for high-temperature molten salt systems

Based on a specific molten salt (e.g., chloride, fluoride, iodide) investigated, different working and reference electrode materials can be selected considering the chemical and thermal stability of the electrochemical cell components. In this talk, the electrode materials and challenges encountered with a spectro-electrochemical setup installed inside a glovebox, and the solutions implemented to address these challenges, specifically for the chloride and iodide molten salts will be presented. For molten chlorides, the fundamental interactions between neodymium chloride (NdCl3) and Nd metal in lithium chloride-potassium chloride eutectic salt were investigated at 773 K. The electrochemical transitions Nd2+,3+/Nd(s) were analyzed using an inert W electrode with cyclic voltammetry and chronoamperometry techniques, coupled with in-situ UV-Vis spectroscopy to elucidate the kinetic pathways of this disproportionation reaction (eq. 1). Nd(s) + NdCl3 = NdCl2 (1) For molten iodides, the challenges related to working electrode selectivity and present spectro-electrochemical results obtained from cyclic voltammetry measurements conducted at 673 K will be discussed.

36 - MATERIALS SCIENCE↗

Impedances of electrochemically impregnated nickel electrodes as functions of potential, KOH concentration, and impregnation method

Impedances of fifteen electrodes form each of the four U.S. manufactures were measured at 0.200 V vs. the Hg/HgO reference electrode. This corresponds to a voltage of 1.145 for a Ni/H2 cell. Measurements were also made of a representative sample of these at 0.44 V. At the higher voltage, the impedances were small and very similar, but at the lower voltage there were major differences between manufacturers. Electrodes from the same manufacturers showed only small differences. The impedances of electrodes from two manufacturers were considerably different in 26 percent KOH from those in 31 percent KOH. These preliminary results seen to correlate with the limited data from earlier life testing of cells from these manufacturers. The impedances of cells being tested for Space Station Freedom are being followed, and more impendance measurements of electrodes are being performed as functions of manufacturer, voltage, electrolyte concentration, and cycle history in hopes of finding better correlations of impedance with life.

Reid, Margaret A.↗

Platinum electrodes for electrochemical detection of bacteria

Bacteria is detected electro-chemically by measuring evolution of hydrogen in test system with platinum and reference electrode. Using system, electrodes of platinum are used to detect and enumerate varieties of gram-positive and gram-negative organisms compared in different media.

Wilkins, J. R.↗

Exploring Electrode-Level State-of-Charge and State-of-Health Dynamics in Lithium-Ion Battery Cells: Modeling and Experimental Identification

A computationally efficient model serves as a critical prerequisite for battery performance analysis and advanced battery management algorithm design. Although battery models that capture cell-level behavior have been widely explored in existing literature, electrode-level battery models have received much lesser attention till to date. However, such electrode-level models can significantly increase battery performance and life by enabling electrode-level health-conscious control. Such electrode-level control can effectively expand usable energy and power limits of the battery cells by utilizing the knowledge of individual electrodes' charge and health. In this context, this paper presents a comprehensive battery model developed with a reference electrode insertion that captures (i) electrode-level charge/discharge dynamics, (ii) stoichiometric and temporal dependencies of electrode-level resistances, (iii) solid electrolyte interface (SEI) layer growth as key degradation phenomenon, and (iv) capacity fade and resistance rise in each electrode due to nominal battery aging. The proposed model is identified, and a preliminary validation is performed utilizing terminal voltage and negative electrode potential data collected from a pouch cell under one continuous cycling and accelerated aging conditions where the cell experienced 14% capacity loss.

aging↗

Ocular Vestibular Evoked Myogenic Potentials Using Head Striker Stimulation

Introduction: Over the last two decades, several studies have been published on the impact of long-duration (i.e., 22 days or longer) spaceflight on the central nervous system (CNS). In consideration of the health and performance of crewmembers in flight and post-flight, we are conducting a controlled prospective longitudinal study to investigate the effects of spaceflight on the extent, longevity and neural bases of sensorimotor, cognitive, and neural changes. Multiple studies have demonstrated the effects of spaceflight on the vestibular system. One of the supporting tests conducted in this protocol is the Vestibular Evoked Myogenic Potential (VEMP) test that provides a unilateral measure of otolith (saccule and utricle) function. A different approach was taken for ocular VEMP (oVEMP) testing using a head striker system (Wackym et al. 2012). The oVEMP is generally considered to be a measure of utricle function. The the otolithic input to the inferior oblique muscle is predominately from the utricular macula. Thus, quantitatively, oVEMP tests utricular function. Another practical extension of these relationships is that the oVEMP reflects the superior vestibular nerve function. Methods: Ground testing was administered on 16 control subjects and for 8 subjects over four repeated sessions spanning 70 days. The oVEMP was elicitied via a hand held striker by a vibrotactile pulse presented at the rate of 1 Hz for 24 seconds on the side of the head as subjects lay supine on a gurney. Subjects were directed to gaze approximately 25 degrees above straight ahead in semi-darkness. For the oVEMP electromyograms will be recorded with active bipolar electrodes (Delsys Inc., Boston, MA) on the infra-orbital ridge 1 cm below the eyelid with a reference electrode on the below the knee cap. The EMG potentials were amplified; band-pass filtered using a BagnoliTM Desktop EMG System (Delsys Inc., Boston, MA, USA). This EMG signal is sampled at 10 kHz and the data stimulus onset to 100 MS was averaged over 24 trial repetitions for the vibrotactile VEMP. The typical oVEMP EMG response is an excitatory potential with first peak occurring at 11-12 ms and second peak at 18 ms. This requires a total recording time of approximately 29 seconds per trial which includes 5 seconds of no vibrotactile stimulation at the beginning of the protocol. The primary dependent measures consist of the latency and peak-to-peak amplitude from the EMG signals, which will be normalized to EMG levels at the beginning of the protocol. Data were collected for 3 repeated trials with striker stimulation on both the left and right side of the head Results: The oVEMP p1 range was observed at 3-14 ms and n1 at 7-19 ms. The striker system provided a consistent and rapid method for oVEMP testing. Discussion: Crew testing is in progress to determine changes in results between pre and post flight.

De Dios, Y. E.↗

Evaluation testing of a portable vapor detector for Part-Per-Billion (PPB) level UDMH and N2H4

Trace level detection of hydrazine (N2H4), monomethyl hydrazine (MMH) and unsymmetrical dimethylhydrazine (UDMH) has been receiving increased attention over the past several years. In May 1995 the American Conference of Government Industrial Hygienists (ACGIH) lowered their acceptable threshold limit value (TLV) from 100 parts-per-billion (ppb) to 10 ppb. Several types of ppb-level detectors are being developed by the United States Air Force (USAF) Space and Missile Systems Center (SMSC). A breadboard version of a portable, lightweight hydrazine detection sensor was developed and produced by Giner Corp. for the USAF. This sensor was designed for ppb level UDMH and N2H4 vapor detection in near real-time. This instrument employs electrochemical sensing, utilizing a three electrode cell with an anion-exchange polymer electrolyte membrane as the only electrolyte in the system. The sensing, counter and reference electrodes are bonded to the membrane forming a single component. The only liquid required to maintain the sensor is deionized water which hydrates the membrane. At the request of the USAF SMSC, independent testing and evaluation of the breadboard instrument was performed at NASA's Toxic Vapor Detection Laboratory (TVDL) for response to ppb-level N2H4 and UDMH and MMH. The TVDL, located at Kennedy Space Center (KSC) has the unique ability to generate calibrated sample vapor streams of N2H4, UDMH, and MMH over a range from less than 10 ppb to thousands of parts per million (ppm) with full environmental control of relative humidity (0-90%) and temperature (0-50 C). The TVDL routinely performs these types of tests. Referenced sensors were subjected to extensive testing, including precision, linearity, response/recovery times, zero and span drift, humidity and temperature effects as well as ammonia interference. Results of these tests and general operation characteristics are reported.

Curran, Dan↗

Numerical Simulation and Modeling of Hydrogen Gas Evolution on Planar and Microwire Array Electrodes

The impact of gas evolution on the electrochemical characteristics of planar electrodes and microwire array electrodes has been analyzed using modeling and simulation. The impacts can mainly be broken into three phenomena: a) a shift in the local reversible hydrogen electrode potential; b) hyperpolarization; and c) an increase in the solution resistance of the electrolyte. The local reversible hydrogen electrode potential shift was found to play the most important role, constituting >40% of the total potential drop between the cathode and reference electrode, following correction for cell resistance. Compared to planar electrodes, a microwire array structure reduces the impact of bubbles on the solution conductance, but the shift in the local reversible hydrogen electrode potential varies with distance from the actual electrode surface.

25 ENERGY STORAGE↗