Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Natural Gas Geothermal Combined Cycle Power Plant Analysis

Low temperature geothermal resources, including those associated with oil and gas production, are an underutilized source of low carbon energy. The present work investigates coupling of low-temperature geothermal resources with concentrating solar and/or natural gas energy sources to increase the number of locations at which power generation from low temperature geothermal resources would be technically and economically viable. Stand-alone and hybrid geothermal power cycles are simulated using SimTech IPSEpro process modeling software. Design point strategies for a hybrid power cycle that may operate with either a single heat source or two simultaneous heat input sources are considered. Additionally, off-design power plant operation is investigated to consider the impacts of the heat source availability and ambient temperature variations. The off-design analysis utilizes a modeling tool that predicts power plant performance at each time step as a function of topping cycle heat input (from gas or solar), bottoming cycle heat input (from geothermal), and ambient temperature. Addition of a steam topping cycle to an organic Rankine cycle geothermal power plant provides opportunities to increase the efficiency and power output relative to a stand-alone geothermal power plant. Additionally, use of the waste heat from gas turbine power generation in a geothermal bottoming cycle provides opportunities to increase the amount of power generation associated with each unit of carbon dioxide emitted. This paper will describe the hybrid plant configuration evaluated, discuss the predicted power cycle performance, and compare with stand-alone natural gas and geothermal power generation cases. The power cycle investigated is expected to be applicable for use with conventional hydrothermal resources as well as with geologic thermal energy storage applications and/or enhanced geothermal systems. The steam topping cycle could use a concentrated solar heat source for fully renewable hybrid plant configuration. A plant initially constructed with a natural gas topping cycle heat source could be converted to a solar heat source part way though the power cycle operational life to achieve life cycle carbon emission reductions.

concentrating solar power↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

Electrification of residential and commercial buildings integrated with hybrid renewable energy systems: A techno-economic analysis

Here, this study assesses the techno-economic viability of city-scale building electrification, comparing a base case scenario with conventional HVAC systems to an electrified scenario with heat pump systems. EnergyPlus simulations reveal a 28% increase in annual electricity consumption in the electrified scenario, shifting the peak consumption from summer to winter with a 49% surge. Hybrid renewable energy systems (HRESs) are then evaluated using HOMER Pro, considering renewable penetration from 0% to 100%. The net present cost (NPC) of the base case and electrified scenarios range from $\$10.34$ to $\$24.38$ billion and $\$8.79$ to $\$50.31$ billion, respectively. Sensitivity analysis explores the impact of carbon tax, fuel price, and renewable subsidies on HRESs in the electrified scenario. Results indicate that applying a carbon tax up to $\$120$/tonne of CO 2 increases the optimum renewable fraction from 5% to 26%, while higher fuel prices and renewable subsidies further enhance the feasibility by shifting the optimum renewable fraction to 60% and 54%, respectively, demonstrating the interplay between economic factors and renewable integration in electrified urban contexts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100°C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

14 SOLAR ENERGY↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

25 ENERGY STORAGE↗

Hot Weather Impacts on Electric School Buses

School bus fleets considering electric school buses can use this resource to learn how hot weather impacts them, and learn how to optimize bus performance when temperatures rise.

ADVANCED PROPULSION SYSTEMS↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban Combined Heat and Power with Integrated Renewables and Energy Storage

This project demonstrated how incorporating a diverse generation and storage portfolio allows an urban district energy system to improve its efficiency by at least 50% and increase its backup power by at least 40% with a return on investment of at least ten years. The improvement was evaluated against the baseline operations for two urban district energy systems (DESs): a synthetic DES and a George Washington University DES. The DES techno-economic framework we developed yields reliability, resilience, and vulnerability indices for urban DESs (including generation and storage) with designation of which technologies improve the security and resiliency metrics by at least 20% compared to the status quo. The indices are benchmarked against baseline scenarios, and cost projections (capital cost and return on investment) to achieve the 20% improvement are reported. The energy management system we developed to conduct these analyses was incorporated into a user-friendly interface that can be used for decision-making by a user with no technical or programming background.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonizing Building Thermal Systems: A How-to Guide for Heat Pump Systems and Beyond

Buildings account for a substantial portion of carbon emissions, primarily due to the widespread use of fossil fuels in heating systems. Decarbonization of heating is essential to meet climate targets and reduce the environmental impact of buildings. Heat pumps are capable of leveraging renewable energy sources and can provide heating and cooling in an energy-efficient manner. By leveraging heat pump technology, buildings can significantly reduce their carbon footprint, minimize energy consumption, and decrease their reliance on fossil fuels. The design and construction community plays a pivotal role in facilitating the transition to heat pump systems for heating and cooling. However, this transition requires specialized knowledge and expertise. This resource was developed for architects, engineers, and contractors in response to an industry need for a comprehensive technical resource that guides them through the intricacies of heat pump system design, installation, and maintenance. This resource provides detailed information on system sizing, selection of appropriate heat systems, heat sources, and integration with existing building systems. Moreover, it emphasizes best practices for ensuring operational efficiency, system longevity, and reliability. The development of this recourse was a collaborative effort between NREL/DOE Better Buildings Design and Construction Allies and ASHRAE Task Force for Building Decarbonization. This resource is composed of two complimentary portions that will be completed and released on separate time frames. The first portion will be completed and released in 2023, while the second portion will be released in 2024.

building thermal systems↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗

Merging flux-variance with surface renewal methods in the roughness sublayer and the atmospheric surface layer

In this article, Two micrometeorological methods utilizing high-frequency sampled air temperature were tested against eddy covariance (EC) sensible heat flux (𝐻) measurements at three sites representing agricultural, agro-forestry, and forestry systems. The two methods cover conventional and newly proposed forms of the flux-variance (FV) and surface renewal (SR) schemes of differing complexities. The sites represent measurements in surface, roughness, and roughness to surface transitional layers. Regression analyzes against EC show that the most reliable FV and SR forms estimate 𝐻 with slopes within ±10% from unity and coefficient of determination 𝑅2 > 0.9 across all the three sites. The best performance of both FV and SR was found at the agricultural site with measurements well within the surface layer, while the worst was found for the tall forest with measurements within the roughness sublayer where its thickness needed to be additionally estimated. The main variable driving 𝐻 in FV is the temperature variance, whereas in SR, it is the geometry of ramp-like structures. Since these structures are also responsible for most of the temperature variance, a novel FV-SR approach emerging from combining the methods is proposed and evaluated against EC measurements and conventional FV and SR schemes. The proposed FV-SR approach requiring only a single fast response thermocouple is potentially independent of calibration and ameliorates some of the theoretical objections that arise when combining ramp statistics with similarity arguments. The combination of methods also provides new insights into the contribution of coherent structures to the temperature variance and its dependence on atmospheric stratification. Other potential utility of the new method is to include it in multi-tool assessments of surface energy fluxes, since a convergence or divergence of the results has a high diagnostic value.