Search NASA⌕ Search

SEARCH · Search NASA

Results for “renewable intermittency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparative techno-economic and environmental analysis of using nuclear energy and fossil energy with carbon sequestration in U.S. Gulf Coast petroleum refineries

U.S. Gulf Coast refineries have processing capacity of approximately 9.4 million barrels of crude oil per day—about 50% of U.S. national capacity—while consuming natural gas, electricity, and hydrogen, resulting in approximately 100 million metric tonnes (MMT) of onsite CO₂ emissions in 2022. This study evaluates two alternative refinery energy supply pathways: nuclear energy (NE) and fossil energy-derived hydrogen with carbon capture and sequestration (FE-CCS; autothermal reforming), intermittent renewable sources are not considered as they cannot reliably meet continuous industrial heat and hydrogen demands. Using publicly available data for refineries, we conducted a bottom-up, facility-level assessment to estimate energy use by type, well-to-gate refinery emissions, and associated costs of integration. Compared to current refinery operations using natural gas energy supply and conventional hydrogen production (steam methane reforming without sequestration), NE and FE-CCS could produce, respectively, average emissions reductions of 37% and 42%, total abatement costs of $\$$52–$\$$221 and $\$$211–$\$$612/MT CO₂, and additional costs of about $\$$0.2–$\$$6 and $\$$3–$\$$11 per barrel of crude, respectively. Our analysis indicates that 25 out of 27 refineries have lower total additional cost ($\$$/bbl.) for the NE scenario than the FE-CCS scenario, making a strong case for NE integration with petroleum refineries. This work's main contribution is a detailed bottom-up refinery-level analysis method that can be utilized by the worldwide refining industry and stakeholders as they assess different technological options, along with their costs and environmental impacts for a specific refinery operation.

Carbon capture and sequestration↗

Efficient Synthetic Natural Gas Production from Direct Air Capture Using Titania-Based Dual Function Materials

Converting atmospheric CO2 into methane offers a compelling pathway to store intermittent renewable electricity and enhance energy security using existing natural gas infrastructure. However, current CO2 utilization approaches remain energy- and capital-intensive, largely due to the need for separate capture, purification, and conversion steps. Integrating CO2 capture with catalytic methanation represents a transformative strategy for process intensification on both the unit operation and molecular levels. We report a series of Ru-Na/TiO2 dual function materials (DFMs) for a reactive carbon capture (RCC) process consisting of simulated direct air capture and subsequent CO2 methanation (DACM). Superior methane desorption purity was observed on TiO2-based DFMs (>94 %) relative to state-of-the-art Al2O3-supported DFMs (77 %). Modifying the process to begin CO2 adsorption immediately following the methanation stage, rather than beginning adsorption near ambient temperature, resulted in >97 % methane desorption purity, suitable for injection into the natural gas pipeline without additional CO2 separation steps.

organic↗

Current research in low temperature proton exchange membrane-based electrolysis and a necessary shift in focus

While hydrogen has limited use in energy markets today, significant growth is possible in grid storage and as an energy carrier in other sectors. Along with lower electricity prices, further hydrogen cost reduction can enable electrochemical water splitting, particularly as the use of intermittent, renewable power sources increases and the quantity and duration of storage requirements limit electrical storage options. With the improved viability of large-scale hydrogen production, research in low temperature electrolysis has dramatically increased. The overwhelming majority of research efforts within proton exchange membrane-based systems has focused on catalyst development, although a smaller set have developed transport layers as well. As proton exchange membrane-based electrolysis shifts into higher technology readiness levels, however, there is a growing need for work optimizing materials integration, developing component-specific and device-level accelerated stress tests, and addressing manufacturing considerations. These areas directly impact electrolyzer performance, durability, and cost, and are critical to advancing hydrogen’s value and electrochemical water splitting.

08 HYDROGEN↗

Development of novel dynamic machine learning-based optimization of a coal-fired power plant

The increasing fraction of intermittent renewable energy in the electrical grid is resulting in coal-fired boilers now routinely ramp up and down. The current state-of-the-art operation for such boilers is to apply steady-state, neural network-based optimization to make control decisions in real-time, and this report demonstrates the feasibility of extending this to dynamic, neural network-based optimization using a long short-term memory neural network. A simplified numerical simulation of a t-fired coal boiler and supporting equipment is used to represent a real plant subjected to both steady-state, neural network-based optimization and dynamic, neural network-based optimization. Using the same intervals and a particle swarm optimization algorithm, the dynamic optimization outperforms the steady-state optimization and realizes up to 4.58% improvement in thermal efficiency. Dynamic optimization with a long short-term memory neural network is shown to both be feasible and beneficial for operation of a coal-fired boiler under changing load.

42 ENGINEERING↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗

Nuclear—thermal energy storage configurations for industrial combined heat and power supply—conceptual and thermodynamic study with high temperature gas-cooled reactor

Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.

combined heat and power (CHP)↗

Advanced modeling of $\mathrm{DER}$s and $\mathrm{UPFC}$ devices with Sparse Tableau Formulation for $\mathrm{ACOPF}$

Distributed energy resources (DERs) are projected to be significant contributors in electric power grid modernization efforts. Yet many distribution and transmission system operators are concerned about potential reliability and security impacts of high penetration of DERs, and cite the need of greater visibility and controllability of decision variables associated with these DERs. Tractable modeling of DERs in AC optimal power flow (ACOPF) is one of the barriers to their integration into the existing operation, planning and market paradigm. Similarly, as more intermittent renewable resources are deployed, power flow control becomes more valuable, and accurate representation of Flexible AC Transmission System (FACTS) devices in ACOPF will likely grow in importance. Here this paper focuses on the detailed representation of substations with the high penetration of DERs, and on the Unified Power Flow Controller (UPFC) FACTS devices, in OPF. To this end, a novel Sparse Tableau Formulation (STF) for ACOPF is used to accurately model such features as substation reconfiguration to accommodate DERs, and to represent decision variables appropriate to the voltage source converters within UPFCs. Numerical studies are provided to demonstrate the impacts of detailed DER and UPFC representations on optimal operation, and the computational efficiency.

42 ENGINEERING↗

Utilization of an Advanced Sensor network to determine fuel heating value and Real-Time net unit heat rate during transient operation

Coal-fired utility boilers are being increasingly used as variable electricity generation to resolve the imbalance in the energy market from the expansion of intermittent renewable energy. The frequent transient operation required to meet residual energy demand has created a challenge for coal-fired units to operate efficiently. This work utilizes an advanced sensor network (ASN) to calculate net unit heat rate (NUHR) of a coal-fired boiler in real time through combustion calculations and statistical correlations to provide the tools for optimizing dynamic operation. Real-time heating values that were necessary to determine fuel input energy to calculate accurate NUHR were found using both fundamental and data-driven methods. Real-time NUHR shows distinct shifts that reflect changes in process conditions that will improve the ability to optimize transient operation. Data-driven heating value correlations had 24% lower root mean square error (RMSE) than the fundamental combustion calculation approach when compared to daily retrospective proximate analysis. Furthermore, the data-driven method RMSE improved by 7% with the inclusion of ASN data. Future work is to validate by comparing unit performance with and without the inclusion of NUHR as a control parameter for the dynamic neural network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of curtailment at The Geysers geothermal Field, California

Geothermal energy has traditionally been viewed as a baseload energy source, but the rapid growth of intermittent renewable energy has led to a need for more flexibility in power generation to avoid mandatory curtailment imposed by grid operators. This study of curtailment at The Geysers provides insights into the magnitude, duration, frequency, temporal and spatial distribution, and potential causes of curtailment events between 2013 and 2018. Annual levels of curtailment range during this period from 9 to 47 GW h, representing 0.15 to 0.81 % of the net generation. Most curtailments occurred at the power plants connected to a lower capacity transmission line and may result from transmission constriction. There is a clear link between negative pricing and economic curtailment, especially when solar production is higher. Economic curtailment events tend to be only a few hours and vary in magnitude up to almost 300 MW, whereas transmission-related curtailment events can be up to several weeks in duration. It is likely that curtailment of geothermal power will be an increasing concern, and could be mitigated by flexible generation strategies and increases in energy storage. It is critical to know the nature of curtailment events so that flexible generation options can be assessed properly.

15 GEOTHERMAL ENERGY↗

Dynamic operation of metal-supported solid oxide electrolysis cells

Symmetric-structure metal-supported solid oxide fuel cells and electrolysis cells (MS-SOFCs, MS-SOECs) offer several advantages over conventional solid oxide cells, including the use of inexpensive materials, high mechanical strength, and rapid ramp-up ability. Aggressive operation of MS-SOCs in fuel cell mode is well-established, including extremely fast start-up, redox tolerance, and imbalanced pressure. Here, we extend dynamic operation to MS-SOCs in SOEC mode with high steam content for both small button cells and a large rectangular cell, including: steam cycling, thermal cycling, redox cycling and power cycling. Steam cycling entailed switching between 3:97 and 50:50 steam:hydrogen ratio. For thermal cycling, the temperature was rapidly varied between 150°C and 700°C for 50 cycles. Redox cycling involved switching the steam side gas between 50 % humidified H 2 and 50 % humidified N 2 for 5 cycles. Power cycling was performed by operating the cell under variable current density, resulting in cell voltage between 1.3V and 2.8V. Degradation rates for each testing strategy were compared to a baseline cell, and found to be similar. In conclusion, the excellent tolerance to dynamic operation increases confidence that MS-SOECs will be compatible with dynamic or intermittent renewable resources.

08 HYDROGEN↗

Agricultural demand response for decarbonizing the electricity grid

Historically, the focus of the agricultural industry has been increasing profit through maximizing crop yield. Costs for energy and water are small compared to equipment and personnel, and are thus often overlooked. However, energy costs for irrigation are increasing and could be exacerbated with declining water levels in many Western states. This trend has motivated many farmers to explore sustainable irrigation water and energy management practices. Additionally, much of this new focus has been directed towards the adoption of new agricultural technologies with a misplaced assumption that technology alone will inherently bring all the benefits. On one hand, farms are going through a paradigm shift, and are turning into net electricity generators, and on the other, higher penetration of intermittent renewable sources into the electricity grid, require dynamic loads to help the grid balance its intra-hour variability and short duration ramps. The agricultural industry could be restructured to utilize larger amounts of renewable energy such as wind and solar and provide a great deal of flexibility to the grid. As emerging producers of clean energy, farmers are required to learn and speak the complex language of the electricity grid in order to monetize their energy generation while making the renewable electricity grid more resilient and reliable. In this paper, we develop a foundational approach for understanding and connecting three important concepts that can help the agricultural industry during this critical transition period. Those three concepts are: (a) current and future needs of the electricity grid, (b) available electricity market mechanisms through which farms can provide services to the grid, and (c) understanding electricity consuming/generating equipment on farms. Finally, defining these concepts and condensing them into a standardized framework, can remove a significant barrier for enabling farms to provide services to the electricity grid while improving their bottom line.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A scalable DG solver for the electroneutral Nernst-Planck equations

The robust, scalable simulation of flowing electrochemical systems is increasingly important due to the synergy between intermittent renewable energy and electrochemical technologies such as energy storage and chemical manufacturing. The high Péclet regime of many such applications prevents the use of off-the-shelf discretization methods. In this work, we present a high-order Discontinuous Galerkin scheme for the electroneutral Nernst-Planck equations. The chosen charge conservation formulation allows for the specific treatment of the different physics: upwinding for advection and migration, and interior penalty for diffusion of ionic species as well the electric potential. Similarly, the formulation enables different treatments in the preconditioner: AMG for the potential blocks and ILU-based methods for the advection-dominated concentration blocks. Here we evaluate the convergence rate of the discretization scheme through numerical tests. Strong scaling results for two preconditioning approaches are shown for a large 3D flow-plate reactor example.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fundamental benchmarking of the discharge properties of negative electrodes in lead acid batteries

The unprecedented scale of energy storage deployment needed to allow high penetration of intermittent renewable energy sources into the electrical grid places significant economic cost and performance targets on battery technologies. Lead batteries, owing to their highly abundant and inexpensive raw materials, can be considered an important solution to grid storage as long as they achieve high material utilization, fast recharge rates, and long cycle life. To address the limitations in material utilization, we need to revisit the electrochemical processes during the discharge step and answer the following question: what are the fundamental limits of the discharge reaction? In this work we discuss how well-defined lead metal surfaces with nanometer scale roughness allow us to resolve the accessible discharge capacity for both faradaic and non-faradaic processes as a function of electrolyte concentration and in the presence of traditional additives. The direct connection between PbSO 4 layer morphology and discharge rates gives us important insights on the mechanism of discharge as related to the dissolution and passivation events. In conclusion, this work sets the stage for reimagining the design of lead batteries with implications to grid storage applications.

25 ENERGY STORAGE↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

PHEVs are More about the grid than the vehicles

Plug-in hybrid electric vehicles (PHEVs) could be used as an effective storage medium to absorb intermittent renewable energy when it is available. Charged vehicles can run on the stored energy when needed. A recent study by the Pacific Northwest National Laboratory concluded that some 73 percent of U.S. light vehicles can be supplied with the existing utility infrastructure in place, provided the charging was restricted to off-peak periods. That would reduce U.S. oil imports by 6.2 million barrels per day, roughly 52 percent of U.S. oil imports. The limiting factors increasingly appear to be on the utility side, for example, making sure that the vehicles are charged during off-peak hours at discounted prices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anion-Exchange-Membrane Electrolysis with Alkali-Free Water Feed

Hydrogen is a green and sustainable energy vector that can facilitate the large-scale integration of intermittent renewable energy, renewable fuels for heavy transport, and deep decarbonization of hard-to-abate industries. Anion-exchange-membrane water electrolyzers (AEM-WEs) have several achieved or expected competitive advantages over other electrolysis technologies, including the use of precious metal-free electrocatalysts at both electrodes, fluorine-free hydrocarbon-based ionomeric membranes and bipolar plates based on inexpensive materials. Contrasting the analogous proton-exchange-membrane system (PEM-WE), where pure water is circulated (no support electrolyte), the current generation of AEM-WEs necessitates the circulation of a dilute aqueous alkaline electrolyte for reaching high energy efficiency and durability. For several reasons, including but not limited to lower cost of balance-of-plant, lower operating cost and improved device's lifetime, achieving high cell efficiency and performance using an alkali-free water feed is highly desirable. In this review, we develop and build a foundational understanding of AEM-WEs operating with pure water, as well as discuss the effects of operating with natural water feeds like seawater. After a discussion of the possible advantages of pure-water-fed AEM-WEs, we cover the thermodynamic and kinetic processes involved in AEM-WE, followed by a detailed review of materials and components and their integration in the device. We highlight the influence of electrolyte composition and alkali/electrolyte-free feed on the membrane-electrode assembly, ionomers, electrocatalysts, porous transport layer, bipolar plates and operating configuration. We provide evidence for how the pure water feed engenders several issues related to the degradation of device components and propose mitigation strategies.

Electrodes↗

Multiobjective Dynamic Optimization for Optimal Load-Following of Natural Gas Combined Cycle Power Plants under Stress Constraints

With the increasing penetration of intermittent renewable energy sources into the electric grid, there is an associated need for conventional thermal power plants that are designed to operate at base-load conditions to cycle their load rapidly and frequently and operate under low-load conditions. Fast load-following operations lead to plant efficiency loss and the reduction of equipment life. A high-fidelity dynamic model of a natural gas combined cycle power plant, with rigorous equipment level submodels, is developed to capture the plant transient performance and the thermomechanical stress evolution at the high-pressure drum is computed to assess the drum life consumption. Stress evolution is modeled for the location of the edge at the drum/downcomer junction that experiences high circumferential stress amplitude during the fast load-following operation, leading to higher fatigue damage than locations considered under existing design standards. A dynamic optimization problem is solved for optimal load-following operation. Depending on the value of the stress constraint and the desired ramp rate, satisfying the desired stress constraint may be infeasible without relaxing the ramp rate. A multiobjective dynamic optimization problem is solved using a lexicographic approach that minimizes ramp rate relaxation and maximizes efficiency while satisfying stress constraints, avoiding spraying to saturation, and maintaining main steam and reheat steam temperature within bounds. It was observed that the optimal ramp rate can be highly nonlinear as opposed to the industry-standard linear ramp rate. Nonlinear optimal ramp-rate profiles not only help to avoid stress constraints that may be unavoidable by using the linear profile but also result in higher efficiency than the linear profile. Furthermore, the study shows that there is a strong tradeoff between the relaxation in the plant ramp rate and the time-average thermal efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗