Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution test pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

30-lens interferometer for high energy x-rays

We report a hard X-ray multilens interferometer consisting of 30 parallel compound refractive lenses. Under coherent illumination each CRL creates a diffraction limited focal spot - secondary source. An overlapping of coherent beams from these sources resulting in the interference pattern which has a rich longitudinal structure in accordance with the Talbot imaging formalism. The proposed interferometer was experimentally tested at ID11 ESRF beamline for the photon energies 32 keV and 65 keV. The fundamental and fractional Talbot images were recorded with the high resolution CCD camera. An effective source size in the order of 15 µm was determined from the first Talbot image proving that the multilens interferometer can be used as a high resolution beam diagnostic tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GENESPACE tracks regions of interest and gene copy number variation across multiple genomes

The development of multiple chromosome-scale reference genome sequences in many taxonomic groups has yielded a high-resolution view of the patterns and processes of molecular evolution. Nonetheless, leveraging information across multiple genomes remains a significant challenge in nearly all eukaryotic systems. These challenges range from studying the evolution of chromosome structure, to finding candidate genes for quantitative trait loci, to testing hypotheses about speciation and adaptation. Here, we present GENESPACE, which addresses these challenges by integrating conserved gene order and orthology to define the expected physical position of all genes across multiple genomes. We demonstrate this utility by dissecting presence–absence, copy-number, and structural variation at three levels of biological organization: spanning 300 million years of vertebrate sex chromosome evolution, across the diversity of the Poaceae (grass) plant family, and among 26 maize cultivars. The methods to build and visualize syntenic orthology in the GENESPACE R package offer a significant addition to existing gene family and synteny programs, especially in polyploid, outbred, and other complex genomes.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal and electrostatic simulations of the diagnostic calorimeter for the Source for Production of Ion of Deuterium Extracted from RF plasma beam

To study and optimise negative ion production for the ITER neutral beam injectors, a test facility is under construction in Padova with the aim of testing beam characteristics and to verify the source proper operation. The instrumented calorimeter STRIKE (short-time retractable instrumented kalorimeter experiment) is being developed to characterise the SPIDER (Source for Production of Ion of Deuterium Extracted from RF plasma) beam during short operations. The paper presents an investigation of the response of STRIKE measurement systems. It results that biasing is necessary to cope with the influence of secondary electrons on current measurements; moreover, despite the discretisation of the recorded thermal patterns introduced by the pixels of thermal cameras, a sufficient spatial resolution is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined mixed approach algorithm for in-line phase-contrast x-ray imaging

Purpose: In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an imaging modality thought to enhance the total contrast of the images through the phase shift introduced by the object (human body part); PRI is a mathematical technique to extract the quantitative phase-shift map from PCI. A new phase-retrieval algorithm for the in-line phase-contrast x-ray imaging is here proposed. Methods: The proposed algorithm is based on a mixed transfer-function and transport-of-intensity approach (MA) and it requires, at most, an initial approximate estimate of the average phase shift introduced by the object as prior knowledge. The accuracy in the initial estimate determines the convergence speed of the algorithm. The proposed algorithm retrieves both the object phase and its complex conjugate in a combined MA (CMA). Results: Although slightly less computationally effective with respect to other mixed-approach algorithms, as two phases have to be retrieved, the results obtained by the CMA on simulated data have shown that the obtained reconstructed phase maps are characterized by particularly low normalized mean square errors. The authors have also tested the CMA on noisy experimental phase-contrast data obtained by a suitable weakly absorbing sample consisting of a grid of submillimetric nylon fibers as well as on a strongly absorbing object made of a 0.03 mm thick lead x-ray resolution star pattern. The CMA has shown a good efficiency in recovering phase information, also in presence of noisy data, characterized by peak-to-peak signal-to-noise ratios down to a few dBs, showing the possibility to enhance with phase radiography the signal-to-noise ratio for features in the submillimetric scale with respect to the attenuation-based imaging. Conclusions: It has been shown that phase-retrieved radiographies can be used both to have quantitative phase information about soft tissues, complementary to the attenuation information, and to enhance the visibility of details inside soft tissues, with higher efficiency with respect to phase radiography.

60 APPLIED LIFE SCIENCES↗

Bench testing of a heterodyne CO 2 laser dispersion interferometer for high temporal resolution plasma density measurements

Here, a heterodyne detection scheme is combined with a 10.59 μm CO 2 laser dispersion interferometer for the first time to allow large bandwidth measurements in the 10-100 MHz range. The approach employed utilizes a 40 MHz acousto-optic cell operating on the frequency doubled CO 2 beam which is obtained using a high 2nd harmonic conversion efficiency orientation patterned gallium arsenide crystal. The measured standard deviation of the line integrated electron density equivalent phase resolution obtained with digital phase demodulation technique, is 4 × 10 17 m –2 . Air flow was found to significantly affect the baseline of the phase signal, which an optical table cover was able to reduce considerably. The heterodyne dispersion interferometer (DI) approach is found to be robustly insensitive to motion, with measured phase shifts below baseline drifts even in the presence of several centimeters of retroreflector induced path length variations. Plasma induced dispersion was simulated with a wedged ZnSe plate and the measured DI phase shifts are consistent with expectations.

47 OTHER INSTRUMENTATION↗

X-RAY STRIPES IN TYCHO'S SUPERNOVA REMNANT: SYNCHROTRON FOOTPRINTS OF A NONLINEAR COSMIC-RAY-DRIVEN INSTABILITY

High-resolution Chandra observations of Tycho's supernova remnant (SNR) have revealed several sets of quasi-steady, high-emissivity, nearly parallel X-ray stripes in some localized regions of the SNR. These stripes are most likely the result of cosmic-ray (CR) generated magnetic turbulence at the SNR blast wave. However, for the amazingly regular pattern of these stripes to appear, simultaneous action of a number of shock-plasma phenomena is required, which is not predicted by most models of magnetic field amplification. A consistent explanation of these stripes yields information on the complex nonlinear plasma processes connecting efficient CR acceleration and magnetic field fluctuations in strong collisionless shocks. The nonlinear diffusive shock acceleration (NL-DSA) model described here, which includes magnetic field amplification from a CR-current-driven instability, does predict stripes consistent with the synchrotron observations of Tycho's SNR. We argue that the local ambient mean magnetic field geometry determines the orientation of the stripes and therefore it can be reconstructed with the high-resolution X-ray imaging. The estimated maximum energy of the CR protons responsible for the stripes is {approx}10{sup 15} eV. Furthermore, the model predicts that a specific X-ray polarization pattern, with a polarized fraction {approx}50%, accompanies the stripes, which can be tested with future X-ray polarimeter missions.

79 ASTRONOMY AND ASTROPHYSICS↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

SU-F-J-44: Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes

Purpose: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room laser based alignment system, and to verify the feasibility of the RAMS. Methods: The RAMS was composed of a room laser sensing array (RLSA), an analog-todigital converter, and a control PC. In the RLSA, seven photodiodes (each in 1 mm width) are arranged in a pattern that the RAMS provides alignment in 1 mm resolution. It works based on detecting laser light aligned on one of photodiodes. When misaligned, the laser would match with different photodiode(s) giving signal at unexpected location. Thus, how much displaced can be determined. To verify the reproducibility of the system with respect to time as well as repeated set-ups, temporal reproducibility and repeatability test was conducted. The accuracy of the system was tested by obtaining detection signals with varying laser-match positions. Results: The signal of the RAMS was found to be stable with respect to time. The repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. In the accuracy test, signals between when the laser was aligned and notaligned with any of sensors could be distinguished by signal intensity. The signals of not-aligned sensors were always below 75% of the signal of the aligned sensor. It was confirmed that the system could detect 1 mm of movement by monitoring the pattern of signals, and could observe the movement of the system in real-time. Conclusion: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. The system is relatively simple, not expensive, and considered to be easily incorporated into conventional room laser systems for real-time alignment monitoring. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of the intraseasonal variability over the Eastern Pacific ITCZ in climate models

During boreal summer, convective activity over the eastern Pacific (EPAC) inter-tropical convergence zone (ITCZ) exhibits vigorous intraseasonal variability (ISV). Previous observational studies identified two dominant ISV modes over the EPAC, i.e., a 40-day mode and a quasi-biweekly mode (QBM). The 40-day ISV mode is generally considered a local expression of the Madden-Julian Oscillation. However, in addition to the eastward propagation, northward propagation of the 40-day mode is also evident. The QBM mode bears a smaller spatial scale than the 40-day mode, and is largely characterized by northward propagation. While the ISV over the EPAC exerts significant influences on regional climate/weather systems, investigation of contemporary model capabilities in representing these ISV modes over the EPAC is limited. In this study, the model fidelity in representing these two dominant ISV modes over the EPAC is assessed by analyzing six atmospheric and three coupled general circulation models (GCMs), including one super-parameterized GCM (SPCAM) and one recently developed high-resolution GCM (GFDL HIRAM) with horizontal resolution of about 50 km. While it remains challenging for GCMs to faithfully represent these two ISV modes including their amplitude, evolution patterns, and periodicities, encouraging simulations are also noted. In general, SPCAM and HIRAM exhibit relatively superior skill in representing the two ISV modes over the EPAC. While the advantage of SPCAM is achieved through explicit representation of the cumulus process by the embedded 2-D cloud resolving models, the improved representation in HIRAM could be ascribed to the employment of a strongly entraining plume cumulus scheme, which inhibits the deep convection, and thus effectively enhances the stratiform rainfall. The sensitivity tests based on HIRAM also suggest that fine horizontal resolution could also be conducive to realistically capture the ISV over the EPAC, particularly for the QBM mode. Further analysis illustrates that the observed 40-day ISV mode over the EPAC is closely linked to the eastward propagating ISV signals from the Indian Ocean/Western Pacific, which is in agreement with the general impression that the 40-day ISV mode over the EPAC could be a local expression of the global Madden-Julian Oscillation (MJO). In contrast, the convective signals associated with the 40-day mode over the EPAC in most of the GCM simulations tend to originate between 150°E and 150°W, suggesting the 40-day ISV mode over the EPAC might be sustained without the forcing by the eastward propagating MJO. Further investigation is warranted towards improved understanding of the origin of the ISV over the EPAC

58 GEOSCIENCES↗

Commissioning of the Mu2e tracker DAQ, planning for the Vertical Slice Test and pre-pattern recognition studies

The primary objective of the Mu2e experiment at Fermilab is to search for the neutrino-less coherent $\mu \rightarrow e$ conversion in the field of an aluminum nucleus ($\mu^- \text{Al} \rightarrow e^- \text{Al}$). The signature of this process is a monochromatic Conversion Electron (CE) with an energy of approximately 104.97 MeV \cite{bartoszek2015mu2e}. Within the Standard Model (SM), the branching ratio for this process, including neutrino masses and oscillation, is expected to be less than $\mathcal{O}(10^{-50})$. This value is far beyond current experimental capabilities. However, models of physics beyond the SM predict much higher relative rates, approaching an observable level. The SINDRUM II experiment set an upper limit on muon conversion at $7 \times 10^{-13}$ (90\% CL) on Au target \cite{SINDRUMII:2006dvw}, and the Mu2e collaboration aims to improve this limit by four orders of magnitude. Observing this process would provide a clear evidence of physics beyond the Standard Model. A brief discussion of the theoretical and experimental aspects is provided in Chapter \ref{intr}. Mu2e adopts a sophisticated experimental setup to achieve its goals, further described in Chapter \ref{mu2echapter}. The central part of the Mu2e detector is the tracker, that consists of 18 tracking stations. The tracker must provide excellent momentum resolution, approximately 1 MeV/c, to distinguish the monochromatic CE signal from the background. To minimize the energy losses, a straw tube tracker will be used \cite{bobbb}. Chapter \ref{chaptertrk} provides an overview of the straw tracker design and its working principles. This Thesis presents a comprehensive study of the Mu2e tracker, covering complementary aspects from initial commissioning to optimization and first steps of the calibration processes. My work at Fermilab has been focused on the complete Data Acquisition (DAQ) testing from both hardware and software perspectives. I was involved in the commissioning of the Mu2e DAQ system and the Vertical Slice Test (VST) of the tracker. The VST encompasses the entire testing chain, from the straws to the readout, and to processed data on disk. I was also focused on the offline analysis, especially on pre-pattern recognition studies, to explore the best methods for identifying $\delta$-electrons during the data taking. Chapter \ref{commissioning} details the commissioning of the tracker DAQ system, emphasizing the importance of understanding of the readout process before the data acquisition. This includes validating the readout logic and firmware through Monte Carlo simulations to confirm functionality and buffering, monitoring the quality of the data from the tracker preamplifiers and front-end electronics, and assessing overall DAQ performance to ensure reliability during future calibration and data-taking. Chapter \ref{planning} discusses the initial steps towards the tracker calibration. The ultimate goal is to perform a time calibration of the first assembled station of the tracker using cosmic muons, aiming for a longitudinal hit position resolution better than 4 cm. This involves determining the signal propagation times and channel-to-channel delays. I performed a Monte Carlo study to determine the impact of the station orientation on the quality of the calibration, in particular on the cosmic track reconstruction, focusing on potential biases that could arise. These studies provide essential insights into the operation, optimization, and calibration of the Mu2e tracker system. Given the high data volume expected during Mu2e operations, estimated at approximately 7 PBytes per year, optimizing memory usage and minimizing CPU consumption are critical. A significant challenge lies in effectively flagging $\delta$-electron hits, which are the primary source of hits in the tracker, without compromising the efficiency of CE hit detection and track reconstruction. A detailed study of pre-pattern recognition and a thorough comparison of two $\delta$-electron flagging algorithms is provided in Chapter \ref{delta}. In Chapter \ref{conclusions}, the findings are concisely summarized, offering a comprehensive synthesis of the research and emphasizing the key insights derived from this study.

43 PARTICLE ACCELERATORS↗

PSSP, a Computer Program for the Crystal Structure Solution of Molecular Materials from X-ray Powder Diffraction Data

This work describes the computer program PSSP (powder structure solution program) for the crystal structure solution of molecular solids from X-ray powder diffraction data. This direct-space structure solution program uses the simulated annealing global optimization algorithm to minimize the difference between integrated intensities calculated from trial models and those extracted in a Le Bail fit of the experimental pattern, using a cost function for dealing with peak overlap through defined intensity correlation coefficients, computationally faster to calculate than R{sub wp}. The methodology outlined is applicable to organic solids composed of moderately complex rigid and flexible molecules, using diffraction data up to relatively low resolution. PSSP performance tests using 11 molecular solids with six to 20 degrees of freedom are analyzed.

99 GENERAL AND MISCELLANEOUS↗

Large area direct-write focused ion-beam lithography with dual-beam microscope.

The authors have investigated the performance of focused ion-beam (FIB) direct-write lithography for large area (multiple write-field) patterning in an FEI Nova Nanolab 600 dual-beam microscope. Their system is configured with a 100 nm resolution X-Y stage and a RAITH ELPHY LITHOGRAPHY control interface, with its own integrated 16 bit DAC pattern generator and software. Key issues with regard to configuration, process parameters, and procedures have been addressed. Characterization of stitching errors, pattern repeatability, and drift were performed. Offset lithography (multiple exposures with offset write fields) and in-field registration marks were evaluated for correcting stitching errors, and a test microfluidic device covering an area of 1 x 1.4 mm{sup 2} was successfully fabricated. The authors found that by using a combination of offset lithography and in-field registration mark correction methods, the stitching errors can be kept well below 100 nm. They also found that due to higher beam deflection speed provided by the electrostatic scanning in FIB systems versus the wide-spread electron-beam systems with electromagnetic scanning, FIB lithography can be just as fast as electron-beam lithography for typical mill depths down to about 200-500 nm (material dependent). This opens the door for a large suite of applications for materials where pattern transfer is difficult or impossible by reactive methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Inverse Modeling of Hydrologic Parameters Using Surface Flux and Runoff Observations in the Community Land Model

This study demonstrates the possibility of inverting hydrologic parameters using surface flux and runoff observations in version 4 of the Community Land Model (CLM4). Previous studies showed that surface flux and runoff calculations are sensitive to major hydrologic parameters in CLM4 over different watersheds, and illustrated the necessity and possibility of parameter calibration. Two inversion strategies, the deterministic least-square fitting and stochastic Markov-Chain Monte-Carlo (MCMC) - Bayesian inversion approaches, are evaluated by applying them to CLM4 at selected sites. The unknowns to be estimated include surface and subsurface runoff generation parameters and vadose zone soil water parameters. We find that using model parameters calibrated by the least-square fitting provides little improvements in the model simulations but the sampling-based stochastic inversion approaches are consistent - as more information comes in, the predictive intervals of the calibrated parameters become narrower and the misfits between the calculated and observed responses decrease. In general, parameters that are identified to be significant through sensitivity analyses and statistical tests are better calibrated than those with weak or nonlinear impacts on flux or runoff observations. Temporal resolution of observations has larger impacts on the results of inverse modeling using heat flux data than runoff data. Soil and vegetation cover have important impacts on parameter sensitivities, leading to the different patterns of posterior distributions of parameters at different sites. Overall, the MCMC-Bayesian inversion approach effectively and reliably improves the simulation of CLM under different climates and environmental conditions. Bayesian model averaging of the posterior estimates with different reference acceptance probabilities can smooth the posterior distribution and provide more reliable parameter estimates, but at the expense of wider uncertainty bounds.

inverse, modeling, hydrologic, parameters, flux, r↗

Tracer-Guided Characterization of Dominant Pore Networks and Implications for Permeability and Wettability in Shale

Pore network characterization is an important aspect in unconventional reservoir evaluation. While application of the technique of scanning electron microscope (SEM) brings substantial advances in pore characterization in shale, understanding the connected pore network that dominates flow in shale samples is limited by using SEM alone because of small fields of view and lack of views of connectivity in 3D. In this research, a technique integrating tracer imbibition, micro-computed tomography (CT) imaging, and SEM imaging was developed to provide a solution for multiscale imaging in shale. Tracer imbibition indicates pore connectivity; micro-CT imaging after tracer imbibition thus provides an overview of the connected pore network at the millimeter scale. With guidance from micro-CT images after tracer imbibition, a more accurate and detailed characterization of pore systems and related mineralogy can be conducted using higher-resolution SEM. The method was applied to five samples from Wolfcamp and Eagle Ford Formations. Results reveal the effectiveness of the integrated method by showing different patterns of distribution of the dominant pore network and different controlling mineralogy. Dominant porosity, estimated from grayscale analyses, displays a good correlation with permeability. This result indicates that dominant porosity is more relevant to permeability than is total porosity. Results from imbibition tests are also compared with that from contact angle measurement, and important implications on wettability can be obtained. The integrated method thus has the capacity to link the dominant pore network and wettability with microscale to submicroscale mineralogy, which can help better understand the pore systems and fluid flow in shale. Plain Language Summary Pore network characterization and wettability are two important aspects in unconventional reservoir evaluation and are crucial to understanding the nature of shale oil or gas storage and production. Here, a new technique integrating tracer imbibition, micro-computed tomography imaging, and scanning electron microscope imaging was developed for a more representative and effective pore characterization in shale. This integrated technique can provide a direct visualization of the dominant pore network in a millimeter-scale sample and, at the same time, can provide a guided pore network characterization under nanoscale resolution. This method thus can generate results that are more representative and more accurate in a more efficient way compared with the traditional scanning electron microscope method. The new technique can also reveal the local wettability in microscale. High-resolution analysis on the tracer imbibition or fluid displacement and mineralogy can shed light on the local wettability and the controlling mineralogy in shale.

58 GEOSCIENCES↗

Sensor-Equipped Unmanned Surface Vehicle for High-Resolution Mapping of Water Quality in Low- to Mid-Order Streams

Longitudinal profiling of water quality via the deployment of sensors from watercraft has advanced the understanding of spatial patterns in large rivers and lakes; however, a similar approach in low- to mid-order streams is lacking. To fill this gap, we developed an unmanned surface vehicle (USV)-water quality measurement platform (the “AquaBOT”). The components of the AquaBOT included a nitrate sensor, multiparameter sonde (temperature, conductivity, turbidity, dissolved oxygen, chlorophyll), quantum sensor, and global positioning system (GPS) mounted to a small pontoon-style USV. The AquaBOT was tested in four streams and rivers in Iowa and Tennessee. All measured water quality parameters varied longitudinally, and greater ranges were generally observed along the low-order, agriculturally influenced streams in Iowa. Nitrate, in particular, was spatially heterogeneous. For example, during one run in early June, concentrations ranged from 10.5 to 12.5 mg N L –1 along a 2.3 km reach and hotspots were observed directly downstream of some tile drains. The spatial resolution of AquaBOT data collected in June was 10× higher than grab sampling data, and measurements were collected in less time and at a comparable cost. Here, the AquaBOT can complement existing measurement approaches and will lead to advancements in understanding the processes driving water quality along the stream-to-river continuum.

47 OTHER INSTRUMENTATION↗

Challenges in studying water fluxes within the soil-plant-atmosphere continuum: A tracer-based perspective on pathways to progress

Tracing and quantifying water fluxes in the hydrological cycle is crucial for understanding the current state of ecohydrological systems and their vulnerability to environmental change. Especially the interface between ecosystems and the atmosphere that is strongly mediated by plants is important to meaningfully describe ecohydrological system functioning. Many of the dynamic interactions generated by water fluxes between soil, plant and the atmosphere are not well understood, which is partly due to a lack of interdisciplinary research. This opinion paper reflects the outcome of a discussion among hydrologists, plant ecophysiologists and soil scientists on open questions and new opportunities for collaborative research on the topic "water fluxes in the soil-plant-atmosphere continuum" especially focusing on environmental and artificial tracers. We emphasize the need for a multi-scale experimental approach, where a hypothesis is tested at multiple spatial scales and under diverse environmental conditions to better describe the small-scale processes (i.e., causes) that lead to large-scale patterns of ecosystem functioning (i.e., consequences). Novel in-situ, high-frequency measurement techniques offer the opportunity to sample data at a high spatial and temporal resolution needed to understand the underlying processes. Here we advocate for a combination of long-term natural abundance measurements and event-based approaches. Multiple environmental and artificial tracers, such as stable isotopes, and a suite of experimental and analytical approaches should be combined to complement information gained by different methods. Virtual experiments using process-based models should be used to inform sampling campaigns and field experiments, e.g., to improve experimental designs and to simulate experimental outcomes. On the other hand, experimental data are a pre-requisite to improve our currently incomplete models. Interdisciplinary collaboration will help to overcome research gaps that overlap across different earth system science fields and help to generate a more holistic view of water fluxes between soil, plant and atmosphere in diverse ecosystems.

54 ENVIRONMENTAL SCIENCES↗

OPTIMIZING A PORTABLE MICROWAVE INTERFERENCE SCANNING SYSTEM FOR NONDESTRUCTIVE TESTING OF MULTI-LAYERED DIELECTRIC MATERIALS

The projected microwave energy pattern, wave guide geometry, positioning methods and process variables have been optimized for use of a portable, non-contact, lap-top computer-controlled microwave interference scanning system on multi-layered dielectric materials. The system can be used in situ with one-sided access and has demonstrated capability of damage detection on composite ceramic armor. Specimens used for validation included specially fabricated surrogates, and ballistic impact-damaged specimens. Microwave data results were corroborated with high resolution direct-digital x-ray imaging. Microwave interference scanning detects cracks, laminar features and material properties variations. This paper presents the details of the system, the optimization steps and discusses results obtained.

36 MATERIALS SCIENCE↗