Search NASA⌕ Search

SEARCH · Search NASA

Results for “returned sample science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

EVALUATION OF LVDTS FOR USE IN ATR IRRADIATION EXPERIMENTS

New materials are being considered for fuel, cladding, and structures in next generation and existing nuclear reactors. Such materials can experience significant dimensional changes during high temperature irradiation. Currently, these changes are determined by repeatedly irradiating a specimen for a defined period of time in the Advanced Test Reactor (ATR) and then removing it from the reactor for evaluation. The time and labor to remove, examine, and return irradiated samples for each measurement makes this approach very expensive. In addition, such techniques provide limited data and may disturb the phenomena of interest. To address these issues, the Idaho National Laboratory (INL) recently initiated efforts to evaluate candidate linear variable differential transducers (LVDTs) for use during high temperature irradiation experiments in typical ATR test locations. Two nuclear grade LVDTs are under consideration – a smaller diameter design qualified for temperatures up to 350 °C and a larger design with capabilities to 500 °C. Calibration and long duration performance evaluations are underway for temperatures up to 600 ºC. This paper presents results from these evaluations, which will ultimately lead to recommendations for an improved design for use in the ATR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of pH on hydrogen pick-up and corrosion in zircaloy-4

Thermal Desorption Spectroscopy (TDS) has been used to investigate the hydrogen pick-up behaviour in different samples of Zircaloy-4. This includes as-received, cold rolled, hydrogen charged, and autoclave-oxidised in pure water and at an elevated pH (with 50% deuterated water) compared to commercial reactors. A characteristic desorption peak for hydrogen has been found at about 650 Celsius degrees, which is theorised to come from hydrides. Cold rolled samples show the same general shape spectrum as the as-received samples, with more hydrogen detected per unit volume of sample. This suggests more hydrogen is in trapping sites or outward diffusion paths are facilitated by dislocations, since no more hydrogen has been added. The peak broadens towards higher temperature, which indicates that additional dislocations could provide trapping sites with a slightly higher energy than the average in the as-received samples. The hydrogen charged samples form a hydride rim, which contains much more hydrogen than the as-received samples. The peak broadens but on average does not shift. The surface oxide, when present, acts as a barrier to the desorption of hydrogen, until the temperature rises enough for the oxygen to migrate into the bulk. The oxide itself only contains a small amount of hydrogen, as is evidenced when the oxide layer is removed, whereupon the desorption peak returns to the characteristic shape seen in as-received samples. Samples oxidised in pure water exhibit a slightly higher oxidation rate, and pass through kinetic transition much earlier than samples exposed to an elevated pH. Before transition pH has little effect on the hydrogen pick-up. After transition the hydrogen pick-up is much higher in pure water, which implies that the H{sup +} concentration in the environment affects hydrogen pickup at this stage. The elevated pH samples showed peaks for D-H and D{sub 2}, which follow the H{sub 2} peaks. The hydrogen content in these samples increases at around 70% of the time to the first transition. This may correlate with development of through-thickness percolation paths, which could lead to the pH inside cracks being modified to a lower value, increasing the availability of H{sup +} ions. (authors)

36 MATERIALS SCIENCE↗

Bayesian inference in band excitation scanning probe microscopy for optimal dynamic model selection in imaging

The universal tendency in scanning probe microscopy (SPM) over the last two decades is to transition from simple 2D imaging to complex detection and spectroscopic imaging modes. The emergence of complex SPM engines brings forth the challenge of reliable data interpretation, i.e., conversion from detected signals to descriptors specific to tip–surface interactions and subsequently to material’s properties. In this work, we implemented a Bayesian inference approach for the analysis of the image formation mechanisms in band excitation SPM. Compared to the point estimates in classical functional fit approaches, Bayesian inference allows for the incorporation of extant knowledge of materials and probe behavior in the form of corresponding prior distribution and return the information on the material functionality in the form of readily interpretable posterior distributions. We explore the nonlinear mechanical behaviors spatially in a classical ferroelectric material, PbTiO 3 . We observe the non-trivial evolution of the Duffing stiffness term and the nonlinearity of the sample surface, determine spatial clustering of the nonlinear response, and perform a Landau analysis on predicting the nonlinear coefficient, which indicates that ferroelectric behavior can be a cause of the observed results. These observations suggest that the spectrum of anomalous behaviors at the ferroelectric domain walls may be broader than previously believed and can extend to non-conventional mechanical properties in addition to static and microwave conductance.

36 MATERIALS SCIENCE↗

Measurement of Diameter Changes during Irradiation Testing

New materials are being considered for fuel, cladding, and structures in advanced and existing nuclear reactors. Such materials can experience significant dimensional and physical changes during irradiation. Currently in the US, such changes are measured by repeatedly irradiating a specimen for a specified period of time and then removing it from the reactor for evaluation. The time and labor to remove, examine, and return irradiated samples for each measurement makes this approach very expensive. In addition, such techniques provide limited data and handling may disturb the phenomena of interest. In-pile detection of changes in geometry is sorely needed to understand real-time behavior during irradiation testing of fuels and materials in high flux US Material and Test Reactors (MTRs). This paper presents development results of an advanced Linear Variable Differential Transformer-based test rig capable of detecting real-time changes in diameter of fuel rods or material samples during irradiation in US MTRs. This test rig is being developed at the Idaho National Laboratory and will provide experimenters with a unique capability to measure diameter changes associated with fuel and cladding swelling, pellet-clad interaction, and crud buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Getting lost tracking the carbon footprint of hydropower

In the transition to low-carbon electricity, well-quantified estimates of carbon dynamics are needed to ensure that emissions reduction targets are achieved. Here we review the state of the science on carbon accounting for hydropower reservoirs and identify limitations and future solutions. Nearly all research on reservoir greenhouse-gas (GHG) emissions has focused on individual reservoirs in isolation without considering their position in a freshwater network draining organic matter from upstream watersheds or the coordinated operation of reservoir cascades. Second, carbon inventories have extrapolated from a small, non-probabilistic sample of highly variable measurements of GHG emissions to unsampled reservoirs. A stronger statistical foundation is needed to estimate a global inventory and its uncertainty. Third, attribution to hydropower is based on ranks assigned to reservoir purpose. Instead, the physical influence of hydropower on carbon dynamics could be directly measured. Fourth, current carbon-accounting practices neglect time. A time-varying approach would quantify variation in emissions for electricity portfolios from changes in the fuel mix at different times and account for ancillary services, i.e., the ability to support the grid when variable renewables are not available without using natural gas. Reservoirs also sequester a significant portion of inflowing carbon in sediments and slow the carbon cycle by delaying the return of carbon to the atmosphere for decades to centuries. Together, these refinements would help to illuminate pathways toward meeting energy demand with the longest-possible delay in returning carbon to the atmosphere and without adding ancient sources to the pool of carbon cycling through aquatic ecosystems.

13 HYDRO ENERGY↗

Combination of imaging mass spectrometry and electron microscopy for quasi nondestructive surface analysis

We report on a combination of imaging mass spectrometry (MS) and scanning electron microscopy (SEM) developed in a custom designed time-of-flight (TOF) MS instrument with laser post-ionization of sputtered atoms. Elemental (by MS) and topographical (by SEM) mapping of surfaces of heavily contaminated Si collectors from the NASA Genesis sample return mission enabled obtaining much more accurate and detailed depth distribution of the Solar Wind Mg and Ca implanted in these collectors. This is because the cleanest areas were identified by the SEM/MS mapping, and high resolution sputter depth profiling at these locations revealed near-surface (0-15 nm) depth distribution of Mg and Ca, that were used for more accurate fluence calculations of these Solar Wind species. MS imaging was virtually nondestructive at primary ion fluence 10(12) cm(-2), causing no effect on accuracy and precision of quantitative depth profiling that followed the imaging. We also demonstrate importance of such an approach by directly comparing high resolution depth profiles measured on clean areas versus arbitrarily selected areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resilience and recovery of Dehalococcoides mccartyi following low pH exposure

Bioremediation treatment (e.g. biostimulation) can decrease groundwater pH with consequences for Dehalococcoides mccartyi (Dhc) reductive dechlorination activity. To explore the pH resilience of Dhc, the Dhc-containing consortium BDI was exposed to pH 5.5 for up to 40 days. Following 8- and 16-day exposure periods to pH 5.5, dechlorination activity and growth recovered when returned to pH 7.2; however, the ability of the culture to dechlorinate vinyl chloride (VC) to ethene was impaired (i.e. decreased rate of VC transformation). Dhc cells exposed to pH 5.5 for 40 days did not recover the ethene-producing phenotype upon transfer to pH 7.2 even after 200 days of incubation. When returned to pH 7.2 conditions after an 8-, a 16- and a 40-day low pH exposure, tceA and vcrA genes showed distinct fold increases, suggesting Dhc strain-specific responses to low pH exposure. Furthermore, a survey of Dhc biomarker genes in groundwater samples revealed the average abundances of Dhc 16S rRNA, tceA and vcrA genes in pH 4.5–6 groundwater were significantly lower (P-value < 0.05) than in pH 6–8.3 groundwater. Overall, the results of the laboratory study and the assessment of field data demonstrate that sustained Dhc activity should not be expected in low pH groundwater, and the duration of low pH exposure affects the ability of Dhc to recover activity at circumneutral pH.

59 BASIC BIOLOGICAL SCIENCES↗

PM2.5 Active Aerosol Collection Field Campaign Report

The long-range transport of aerosols can affect local air quality as well as contribute elements and constituents to mountain watersheds that have potentially positive (e.g., nitrate) and negative (e.g., heavy metals) effects to the local ecosystem. Isotopic analysis of aerosols can be a powerful tool for deconvolving the relative contributions of far-distant and local sources to the composition of collected aerosols. Our field campaign involved the week-long collection of PM2.5 (i.e., particulate matter with an aerodynamic diameter of about 2.5 microns) aerosols on filters, which were returned to the laboratories at Lawrence Berkeley National Laboratory (LBNL) for analysis. The sampling sites were located at the Gothic, Colorado Surface Atmosphere Integrated Field Laboratory (SAIL) Atmospheric Radiation Measurement (ARM) and the Mt. Crested Butte, Colorado SAIL ARM sites. The original intention was to measure the lead (Pb) and strontium (Sr) isotopic compositions of the collected aerosols at high precision to provide constraints on source portioning and attribution, as well as analyze the chemical compositions and nitrogen and carbon isotopic compositions. However, severe blank issues arose that prevented the planned isotopic analyses of Sr, Pb, C, and N and severely affected the analyses of the bulk chemical compositions of the collected aerosols, resulting in the failure of the study. The issue is described in Section 2.0.

54 ENVIRONMENTAL SCIENCES↗

Distribution and migration mechanism of fluoride in groundwater in the Manas River Basin, Northwest China

Elevated fluoride (F) concentration in groundwater is posing a public health risk in the Manas River Basin (MRB), Northwest China. Based on the characterization of regional groundwater flow, 90 groundwater samples from aquifers were analyzed, along with top-soil leachate and pore-water samples from aquitards. Stable oxygen (δ{sup 18}O) and hydrogen isotopes, radiocarbon and hydrochemical analyses of the groundwater and pore-water samples were conducted to trace groundwater hydrological and hydrochemical processes and thereby understand the distribution and migration mechanism of F. The groundwater is recharged by meteoric precipitation through vapor condensation processes in the Tianshan Mountains. The F concentration in groundwater samples from this basin ranged from 0.11 to 48.15 mg/L (mean 2.56 mg/L). In 37 of the 90 groundwater samples, the F concentrations were above the safe level for drinking water. The F concentrations progressively increased with the residence time and well depths in the northwest of the alluvial-fluvial plain, where groundwater is overexploited for agricultural and domestic use. Positive correlations between F and sodium (Na)/calcium (Ca) indicate that the enrichment and migration of F are influenced by cation exchange processes under high-Na and alkaline pH conditions. The relationships between δ{sup 18}O and F and chloride (Cl) concentrations were nonlinear due to leaching and mixing processes. This shows that vertical leaching by irrigation return flow and mixing with pore water are the dominant processes driving the migration of F in the groundwater flow system of MRB, in addition to geochemical processes.

54 ENVIRONMENTAL SCIENCES↗

Optimizing disk registration algorithms for nanobeam electron diffraction strain mapping

Scanning nanobeam electron diffraction strain mapping is a technique by which the positions of diffracted disks sampled at the nanoscale over a crystalline sample can be used to reconstruct a strain map over a large area. However, it is important that the disk positions are measured accurately, as their positions relative to a reference are directly used to calculate strain. Here in this study, we compare several correlation methods using both simulated and experimental data in order to directly probe susceptibility to measurement error due to non-uniform diffracted disk illumination structure. We found that prefiltering the diffraction patterns with a Sobel filter before performing cross correlation or performing a square-root magnitude weighted phase correlation returned the best results when inner disk structure was present. Lastly, we have tested these methods both on simulated datasets, and experimental data from unstrained silicon as well as a twin grain boundary in 304 stainless steel.

36 MATERIALS SCIENCE↗

Sensing and Sampling of Trace Contaminations by a Dexterous Hexrotor UAV at Nuclear Facilities - 18600

Safe and efficient cleanups are a priority for decontamination and decommissioning of nuclear facilities. The contaminations of byproducts and wastes in such nuclear facilities pose a serious problems while decommissioning, to both the operators and public. Sensing these contaminations and cleaning them is an essential part of the safety procedures. The contaminations might range from low-energy to high-energy byproducts. Sensing these byproducts would require contact based or non-contact based sensing, based on its energy levels. Byproducts such as americium, are low-energy which makes it difficult to sense and sample without contact. Therefore, the workers need to physically swab the surfaces to collect the samples of these contaminations. These tasks pose a great danger for the safety of the human workers which includes the risk to reach greater heights, exposure to the radiation and sampling the entire building. A robotic solution is much more desirable in these cases, where the worker can safely handle the contaminations from a safe area. Use of robotic technologies inside these hazardous environments ensures the safety and enhances the performance. The more suitable robotic solution for reaching great heights and covering large areas of nuclear facilities, are aerial vehicles. Multi-rotor unmanned aerial vehicle (UAV) are chosen for their ability to hover at a position and also fly around in confined spaces. Quadrotors are a common choice of multi-rotor UAVs both research and industry because of its ease to fly and commercial availability. For the applications during the cleanups we need the UAV to not only hover and fly in confined spaces, but also interact with the physical world. Despite of quadrotor's advantages, they are not a best suit as they can't interact with the physical world. The tasks involving physical interactions would require the UAV to apply arbitrary forces and torques in all six degrees of freedom (DOF). As quadrotors are under-actuated and non-holonomic in motion, they cannot exert all the required forces. At Collaborative Robotics Lab, Purdue University, we developed a novel multi-rotor UAV solution, Dexterous Hexrotor, which can exert arbitrary forces and torques in all six DOF, independently and instantaneously. This enables the UAV platform to quickly respond to the external disturbances and precisely hold its position during the mission. The Dexterous Hexrotor serves as a robotic tool for the workers to perform sensing and sampling during the cleanups. Workers can operate Dexterous Hexrotor manually and/or semi-autonomously with human intervention. Manual control requires the worker to fly the Dexterous Hexrotor using a remote control. So the workers should possess knowledge on flying the UAV and to perform physical interaction. A semiautonomous Dexterous Hexrotor requires human input to some extent and requires very less knowledge of flying. The autonomy is designed to operate in flight mode and sampling mode. In flight mode, Dexterous Hexrotor takes off from a 'safe' area, reaches the desired altitude, and fly autonomously towards a sampling point. This sampling point is the target position specified on the 2D reference map. This mode also includes navigation towards the sampling point, avoiding the obstacles in the constrained environment. After reaching a stopping point, Dexterous Hexrotor waits for the human input for a target location to swab and collect samples. The Dexterous Hexrotor is now in sampling mode and waits for the human input. The human operator selects the swabbing location through the live streaming video from onboard camera. Through visual servoing, aided by the map, the UAV will move closer towards the target position. It then transitions to the impact control scheme to perform physical interaction with the wall and collects samples. Once the sample is collected, it autonomously returns back to the takeoff position in 'safe' area for the analysis by mass spectrometry. In this paper, we majorly focus on the physical interaction strategy and the required components which enables the autonomy. Decommissioning of nuclear facilities requires decontamination inside the entire buildings. Decontamination of nuclear facilities involves sensing and sampling the huge buildings, long shafts, etc. Sampling the entire facility is not possible due to the limitation in Dexterous Hexrotor's flight time. But this can be achieved by using a swarm of Dexterous Hexrotors to cover larger areas. The onboard robotic arm can be designed based on the applications such as cleaning, applying sealants, etc. The modularity of the design allows us to switch components as per the requirements of the task. These kind of robotic solutions functioning as tools for the workers, aims to make the work environment safer and playful. (authors)

42 ENGINEERING↗

Metagenomic insights into diazotrophic communities across Arctic glacier forefields

Microbial nitrogen fixation is crucial for building labile nitrogen stocks and facilitating higher plant colonisation in oligotrophic glacier forefield soils. Here, the diazotrophic bacterial community structure across four Arctic glacier forefields was investigated using metagenomic analysis. In total, 70 soil metagenomes were used for taxonomic interpretation based on 185 nitrogenase (nif) sequences, extracted from assembled contigs. The low number of recovered genes highlights the need for deeper sequencing in some diverse samples, to uncover the complete microbial populations. A key group of forefield diazotrophs, found throughout the forefields, was identified using a nifH phylogeny, associated with nifH Cluster I and III. Sequences related most closely to groups including Alphaproteobacteria, Betaproteobacteria, Cyanobacteria and Firmicutes. Using multiple nif genes in a Last Common Ancestor analysis revealed a diverse range of diazotrophs across the forefields. Key organisms identified across the forefields included Nostoc, Geobacter, Polaromonas and Frankia . Nitrogen fixers that are symbiotic with plants were also identified, through the presence of root associated diazotrophs, which fix nitrogen in return for reduced carbon. Additional nitrogen fixers identified in forefield soils were metabolically diverse, including fermentative and sulphur cycling bacteria, halophiles and anaerobes.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical and Structural Study of the Layered, 'Li-Excess' Lithium-Ion Battery Electrode Material Li[Li[subscript 1/9]Ni[subscript 1/3]Mn[subscript 5/9]]O[subscript 2]

The overcapacity mechanism and high voltage process of the Li-excess electrode material Li[Li{sub 1/9}Ni{sub 1/3}Mn{sub 5/9}]O{sub 2} are studied by solid-state NMR, X-ray diffraction, X-ray absorption spectroscopy, transmission electron microscopy, combined with galvanostatic and potentiostatic intermittent titration electrochemical measurements. The cycling performance is improved noticeably when the material is cycled between potential windows of 5.3-2.5 V compared to 4.6-2.5 V. Diffraction data show that structural changes occur at high voltages, the solid-state NMR data of the same samples indicating that the high voltage processes above 4.4 V are associated with Li removal from the structure, in addition to electrolyte decomposition. The NMR spectra of the discharged samples show that cation rearrangements in the transition metal layers have occurred. The XAS spectra confirm that the Mn oxidation state remains unchanged at 4+, whereas Ni{sup 2+} is oxidized to Ni{sup 4+} on charging to 4.4 V, returning to Ni{sup 2+} on discharge, independent of the final charge voltage. A significant change of the shape of the Ni edge is observed in the 4.6-5.3 V potential range on charge, which is ascribed to a change in the Ni local environment. No O{sub 2} evolution was detected based on ex situ analysis of the gases evolved in the batteries, the TEM data showing that thick passivating films form on the electrodes. The results suggest that at least some of the oxygen loss from these lithium-excess materials occurs via a mechanism involving electrolyte decomposition.

36 MATERIALS SCIENCE↗

Detection of small drizzle droplets in a large cloud chamber using ultrahigh-resolution radar

Abstract. A large convection–cloud chamber has the potential to produce drizzle-sized droplets, thus offering a new opportunity to investigate aerosol–cloud–drizzle interactions at a fundamental level under controlled environmental conditions. One key measurement requirement is the development of methods to detect the low-concentration drizzle drops in such a large cloud chamber. In particular, remote sensing methods may overcome some limitations of in situ methods. Here, the potential of an ultrahigh-resolution radar to detect the radar return signal of a small drizzle droplet against the cloud droplet background signal is investigated. It is found that using a small sampling volume is critical to drizzle detection in a cloud chamber to allow a drizzle drop in the radar sampling volume to dominate over the background cloud droplet signal. For instance, a radar volume of 1 cubic centimeter (cm3) would enable the detection of drizzle embryos with diameter larger than 40 µm. However, the probability of drizzle sampling also decreases as the sample volume reduces, leading to a longer observation time. Thus, the selection of radar volume should consider both the signal power and the drizzle occurrence probability. Finally, observations from the Pi Convection–Cloud Chamber are used to demonstrate the single-drizzle-particle detection concept using small radar volume. The results presented in this study also suggest new applications of ultrahigh-resolution cloud radar for atmospheric sensing.

54 ENVIRONMENTAL SCIENCES↗

Contribution To Degradation Study, Behavior Of Unsaturated Polyester Resin Under Neutron Irradiation

Applications of unsaturated polyester thermosetting resins are numerous in construction sector, in transport, electric spare parts manufactures, consumer goods, and anticorrosive materials. This survey reports the effect of thermosetting polymer degradation (unsaturated polyester): degradation by neutrons irradiation. In order to evaluate the deterioration of our material, some comparative characterizations have been done between standard samples and damaged ones. Scanning electron microscopy (SEM), ultrasonic scanning, hardness test (Shore D) are the techniques which have been used. The exposure to a neutrons flux is carried out in the column of the nuclear research reactor of Draria (Algiers-Algeria). The energetic profile of the incidental fluxes is constituted of fast neutrons (PHI{sub R} = 3.10{sup 12} n.cm{sup -2}.s{sup -1}, E = 2 Mev) of thermal neutrons (PHI{sub TH} = 10{sup 13} n.cm{sup -2}.s{sup -1}; E = 0.025 ev) and epithermal neutrons (PHI{sub epi} = 7.10{sup 11} n.cm{sup -2}.s{sup -1}; E>4,9 ev). The received dose flow is 0,4 Kgy. We notice only a few scientific investigations can be found in this field. In comparison with the standard sample (no exposed) it is shown that the damage degree is an increasing process with the exposure. Concerning the description of irradiation effects on polymers, we can advance that several reactions are in competition: reticulation, chain break, and oxidation by radical mechanism. In our case the incidental particle of high energy fast neutrons whose energy is greater or equal to 2 Mev, is braked by the target with a nuclear shock during which the incidental particle transmits a part of its energy to an atom. If the energy transfer is sufficient, the nuclear shock permits to drive out an atom of its site the latter will return positioning interstitially, the energy that we used oversteps probably the energy threshold (displacement energy). This fast neutrons collision with target cores proceeds to an indirect ionization by the preliminary creation of excited secondary species that will generate ionization. Scanning electron microscopy (SEM) performed with an acceleration tension of 0,7 kV shows clearly the caused damage. This observation seems to indicate the presence of major chain breaks for the sample bombarded during 90 minutes. Let us note that the presence of benzenic cores improves behavior toward radiations indeed the chemical function recognized as the most stable to radiations is the aromatic ring. In order to value the rigidity of our material we have determined the Young's modulus . The values are 7.17, 7.60, 8.39 and 8.96 Gpa respectively for blank samples, 30, 60 and 90 minutes exposure ones. Thus, we remark an increase of Young's modulus that can be interpreted in terms of reticulation, provided to use the level of irradiation dose.

36 MATERIALS SCIENCE↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Imaging of Vanadium in Microfossils: A New Potential Biosignature

Being able to distinguish unambiguously the biogenicity of microfossil-like structures in the ancient rock record is a fundamental predicament facing Archean paleobiologists and astrobiologists. Therefore, novel methods for discriminating biological from non-biological chemistries of microfossil-like structures are of the utmost importance in the search for evidence of early life on Earth. This too, is important for the search for life on Mars; either by in situ analyses via rovers, or sample return missions for future analysis here on Earth. Here, we report the application of synchrotron X-ray fluorescence imaging of vanadium, within thermally altered organic-walled microfossils of bona fide biological origin. From our data, we demonstrate that vanadium is present within microfossils of undisputable biological origin. It is well known in the organic geochemistry literature, that elements such as vanadium are enriched and contained within crude oils, asphalts, and black shales that have been formed by diagensis of biological organic material. It has been demonstrated that the origin of vanadium is due to the diagenetic alteration of precursor chlorophyll and heme porphyrin pigment compounds from living organisms. Here, we propose that taken together, microfossil-like morphology, carbonaceous composition, and the presence of vanadium could be used in tandem as a biosignature to ascertain the biogenecity of putative microfossil-like structures.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation hardness characterization of LKH-5 scintillating glass

Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗