Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample activation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Managing temporal relations

Various temporal constraints on the execution of activities are described, and their representation in the scheduling system MAESTRO is discussed. Initial examples are presented using a sample activity described. Those examples are expanded to include a second activity, and the types of temporal constraints that can obtain between two activities are explored. Soft constraints, or preferences, in activity placement are discussed. Multiple performances of activities are considered, with respect to both hard and soft constraints. The primary methods used in MAESTRO to handle temporal constraints are described as are certain aspects of contingency handling with respect to temporal constraints. A discussion of the overall approach, with indications of future directions for this research, concludes the study.

Britt, Daniel L.↗

Study of proton and neutron activation of metal samples in low Earth orbit

The analysis of the gamma-ray spectra taken from samples flown in Spacelab 1; the search for and review of neutron and proton activation cross-sections needed to analyze the results of the Long Duration Exposure Facility (LDEF) activation measurements; additional calculations of neutron induced activation for the LDEF samples; the data analysis plan for the LDEF and Spacelab 2 samples; the measurement of relevant cross-sections with activation of samples of V, Co, In, and Ta at the Indiana University Cyclotron Facility; and the preparation of an extended gamma-ray calibration source through the development of a proper technique to accurately deposit equal quantities of radioactive material onto a large number of point on the source are discussed.

Laird, C. E.↗

Determining HPGe Total Detection Efficiency Using γ–γ Coincidence

Abstract Both the peak and total detection efficiencies are generally needed in order to calculate sample activity from a gamma spectroscopic measurement, except in the case of isotope specific calibration. This is particularly true when the sample is in close proximity to the detector and corrections for cascade summing effects are required to avoid significant inaccuracy in the result. These corrections use the total detection efficiency to correct for summing-in and summing-out events, and the extent of the correction depends on both the geometry and the gamma cascade for the isotope in question. Experimentally determining the total efficiency is a labor intensive endeavor requiring multiple measurements with a set of single-gamma-emitting standards. Modeling the total efficiency vs. energy may be less time consuming, but is also likely to produce less confidence in the final result. Pacific Northwest National Laboratory's Radiation Detection and Nuclear Sciences group has constructed a low background 14-crystal HPGe array for sample measurement; in all measurements, samples will be in close proximity to the germanium crystals. This close geometry and the sheer number efficiency calibrations required for the system have led us to investigate methods to simplify the efficiency calibration procedure. One method we are developing uses the Y-Y coincidence plane to isolate Compton scattering event populations, allowing experimental determination of total detection efficiency values from the measurement of a single mixed isotope standard. A description of the analysis and experimental results of this method are presented.

low background HPGe High Purity Germanium detector↗

Mixed Waste Landfill Annual Long-Term Monitoring & Maintenance Report April 2017-March 2018

Sampling activities for this reporting period included two semiannual monitoring events each for groundwater and soil-vapor, and four quarterly monitoring events for radon. Annual soilmoisture monitoring was conducted in April 2017, and annual tritium surface soil sampling and annual biota sampling (metals and radionuclides) were conducted in August 2017. All monitoring activities were conducted in accordance with LTMMP requirements and no monitoring results exceeded LTMMP trigger levels. All monitoring results were consistent with historical MWL monitoring data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revisiting heat treatment and surface activation of GaAs photocathodes: In situ studies using scanning tunneling microscopy and photoelectron spectroscopy

The lifetime of GaAs photocathodes in polarized electron guns is limited due to the delicate activation layer. An atomically clean and smooth GaAs surface is needed to deposit a robust activation layer, such as Cs 2 Te, with longer lifetime compared to traditional (Cs,O) activation. A previous experiment with Cs 2 Te activation on GaAs used heat cleaning temperatures around 400°C to avoid an increase in surface roughness [Bae et al., Appl. Phys. Lett. 112, 154101 (2018)]. Furthermore, high-temperature heat cleaning around 580°C, which results in a relatively contamination-free surface, could be one possible way to improve quantum efficiency. However, one should be cautious about surface roughness degradation during high-temperature heat cleaning. In this paper, we report results of surface roughness measurements on native, heat cleaned, and (Cs,O) activated GaAs photocathodes under vacuum. The results, measured by ultrahigh vacuum scanning tunneling microscopy, show that the surface roughness improves as the heat cleaning temperature is increased, by at least a factor of three for 580°C heat cleaning, compared to the native sample. Activation with (Cs,O) is shown to increase surface roughness by a factor of four compared to a 580°C heat cleaned sample. This confirms that high-temperature heat cleaning can be useful for depositing good quality robust activation layers on GaAs. Additionally, we also report chemical analysis for each step of preparation for p-doped GaAs photocathodes using X-ray photoelectron spectroscopy (XPS), angle-resolved XPS, and ultraviolet photoelectron spectroscopy. Our results indicate that the (Cs,O) activation layer forms a sandwich structure consists of Cs and oxygen. We found no formation of any specific compound such as Cs 2 O or Cs 11 O 3 .

43 PARTICLE ACCELERATORS↗

Influence of native oxide film on corrosion behavior of additively manufactured stainless steel 316L

The influence of the native oxide film on passive film properties and localized corrosion of additively manufactured SS 316L was studied in 1 wt% HCl by XPS characterization, electrochemical polarization curves, and post-test morphology analysis by SEM. Increased Cr oxidation kinetics was observed in the as-polished sample with the native oxide film resulting in formation of an overall more protective and compact film compared to the cathodically-activated sample. Electrochemical analysis showed that corrosive attack varied between dislocation cell boundaries to cell interiors depending on the initial surface state and polarization conditions. In conclusion, a corrosion mechanism is proposed to explain this variation.

36 MATERIALS SCIENCE↗

Stellar Ar 36 , 38 ( n , γ ) Ar 37 , 39 Reactions and Their Effect on Light Neutron-Rich Nuclide Synthesis

Here, the 36 Ar(n,γ) 37 Ar (t 1/2 = 35 d) and 38 Ar(n,γ) 39 Ar (269 yr) reactions were studied for the first time with a quasi-Maxwellian (kT ~ 47 keV) neutron flux for Maxwellian average cross section (MACS) measurements at stellar energies. Gas samples were irradiated at the high-intensity Soreq applied research accelerator facility-liquid-lithium target neutron source and the 37 Ar/ 36 Ar and 39 Ar/ 38 Ar ratios in the activated samples were determined by accelerator mass spectrometry at the ATLAS facility (Argonne National Laboratory). The 37 Ar activity was also measured by low-level counting at the University of Bern. Experimental MACS of 36 Ar and 38 Ar, corrected to the standard 30 keV thermal energy, are 1.9(3) and 1.3(2) mb, respectively, differing from the theoretical and evaluated values published to date by up to an order of magnitude. The neutron-capture cross sections of 36,38 Ar are relevant to the stellar nucleosynthesis of light neutron-rich nuclides; the two experimental values are shown to affect the calculated mass fraction of nuclides in the region A = 36 – 48 during the weak s process. Finally, the new production cross sections have implications also for the use of 37 Ar and 39 Ar as environmental tracers in the atmosphere and hydrosphere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved lifetime of a high spin polarization superlattice photocathode

Negative Electron Affinity (NEA) activated surfaces are required to extract highly spin-polarized electron beams from GaAs-based photocathodes, but they suffer extreme sensitivity to poor vacuum conditions that results in rapid degradation of quantum efficiency. We report on a series of unconventional NEA activations on surfaces of bulk GaAs with Cs, Sb, and O 2 using different methods of oxygen exposure for optimizing photocathode performance. Additionally, one order of magnitude improvement in lifetime with respect to the standard Cs–O 2 activation is achieved without significant loss of electron spin polarization and quantum efficiency by codepositing Cs, Sb, and O 2 . A strained GaAs/GaAsP superlattice sample activated with the codeposition method demonstrated similar enhancement in lifetime near the photoemission threshold while maintaining 90% spin polarization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SP-1 results for UOC Database Project, 2018

Project personnel at Los Alamos National Laboratory provided analysis support for an IAEA SP-1 task proposal aimed at analysis of materials sampled at various points during the Uranium ore refinement. This effort was proposed as a part of FY18 Uranium Ore Concentrate Sourcing Database project activities. Samples related to this effort are categorized as a set of solid samples and a set of liquid samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of proton and neutron activation of metal samples in low Earth orbit

Progress in the following activities has been made: the analysis of the gamma ray spectra taken from samples flown in Spacelab 2; the search for and review of neutron and proton activation cross sections needed to analyze the results of the Long Duration Exposure Facility (LDEF) activation measurements; the consideration given to data analysis of the LDEF and Spacelab 2 samples; the plan to measure relevant cross sections with nuclear accelerator measurements; and the preparation of an extended gamma ray calibration sources continues through planning and direct measurement of gamma ray efficiency for a Ge(Li) as a function of position along the surface of the detector housing.

Laird, C. E.↗

Automation of particulate characterization

Foreign particles residing on the field carrying surface of accelerator cavities are a known mechanism for field emission. Developing the methods and tools for collecting and characterizing particles found in an accelerator enables process development towards field emission free SRF cavities. Methods are presented for sampling assemblies, components, processes, and environmental conditions utilizing forensic techniques with specialized tooling. Sampling activities to date have produced an inventory of over 850 GSR spindles. Traditional SEM + EDS analysis of this volume of spindles is challenged by labor investment, spindle sampling methods, and the subsequent data pipeline which ultimately results in a statically inadequate dataset for any particulate distribution characterization. A complete systematic analysis of the spindles is enabled by third party software controlling SEM automation for EDS data acquisition. Details of spindle creation, collection equipment, component sampling, automating particle assessment, and data analysis used to characterize samples from beamline elements in CEBAF are presented.

Spradlin, Josh↗

Investigation and Recovery Following the Drum Event at INL's ARP-V Facility - 19517

Contractors working under the Department of Energy's (DoE's) Idaho Field Office have been exhuming and processing buried legacy waste from early weapons development and productions operations since 1984. Since operations began, nearly 400,000 drums have passed through this process. On April 11, 2018, repackaged drums were staged in an airlock (radiological buffer area) awaiting transfer to another facility for characterization. Late in the evening after operations had ended, four of the drums over pressurized causing an energetic displacement of their lids. A significant fraction of drum contents was ejected and dispersed throughout the airlock. The event activated the fire detection system in the facility initiating an emergency response from the site fire department, radiological protection, and operations. Initial intervention by fire department personnel was unsuccessful at quenching the reaction, so the responders egressed to a safe distance and monitored the situation. After determining the event had terminated and it was safe to enter, the facility was assessed revealing significant contamination in the airlock from the ejected waste. The area surrounding the facility was surveyed and it was determined that no contamination was released outside the facility. The Fluor Idaho, LLC (Fluor Idaho) Program Manager commissioned an investigation and recovery effort, which focused on three aspects: (1) technical investigation, (2) event and causal analysis, and (3) facility recovery. A team of highly qualified individuals from around the DOE Complex was assembled to support the technical investigation. The team included representatives from several Fluor Idaho, Fluor Corporate, Battelle Energy Alliance, LLC (INL), LANL, SRNL, South West Research Institute, DOE Carlsbad Field Office, and Defense Nuclear Facility Safety Board, and DOE-Headquarters. This team addressed the reaction mechanism of the event by guiding the sampling activities and coordinating analysis and testing by the analytical laboratories. Independent and experienced investigators were brought in to conduct a rigorous event and cause analysis. The Causal Analysis Team pursued direct, root, and contributing causes. Interviews were conducted, and documents were reviewed to develop an event and causal analysis. The Accelerated Retrieval Project V Operations team mobilized to decontaminate and recover the facility. Significant progress has been made in this effort, area and airborne contamination levels have been significantly reduced allowing limited activities to resume. In addition, this group supported sample collection efforts as directed by the Technical Investigation Team. This paper reviews key findings and milestones from the technical investigation, the event and causal analysis, and facility recovery operations. From these elements of the investigation, lessons learned are identified that would benefit other organizations involved with legacy waste management and disposition. Waste management is common to all sites in the DOE Complex and the events and recovery efforts described in this paper may provide beneficial insights to these operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COSMIC EVOLUTION OF BLACK HOLES AND SPHEROIDS. V. THE RELATION BETWEEN BLACK HOLE MASS AND HOST GALAXY LUMINOSITY FOR A SAMPLE OF 79 ACTIVE GALAXIES

We investigate the cosmic evolution of the black hole (BH) mass-bulge luminosity relation using a sample of 52 active galaxies at z ∼ 0.36 and z ∼ 0.57 in the BH mass range of 10{sup 7.4}-10{sup 9.1} M {sub ☉}. By consistently applying multicomponent spectral and structural decomposition to high-quality Keck spectra and high-resolution Hubble Space Telescope images, BH masses (M {sub BH}) are estimated using the Hβ broad emission line combined with the 5100 Å nuclear luminosity, and bulge luminosities (L {sub bul}) are derived from surface photometry. Comparing the resulting M {sub BH} – L {sub bul} relation to local active galaxies and taking into account selection effects, we find evolution of the form M {sub BH}/L {sub bul}∝(1 + z){sup γ} with γ = 1.8 ± 0.7, consistent with BH growth preceding that of the host galaxies. Including an additional sample of 27 active galaxies with 0.5 < z < 1.9 taken from the literature and measured in a consistent way, we obtain γ = 0.9 ± 0.7 for the M {sub BH} – L {sub bul} relation and γ = 0.4 ± 0.5 for the M {sub BH}-total host galaxy luminosity (L {sub host}) relation. The results strengthen the findings from our previous studies and provide additional evidence for host galaxy bulge growth being dominated by disk-to-bulge transformation via minor mergers and/or disk instabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

NNSA Funded 03-0016, Ion Beam Facility Characterization Compilation (Characterization Funded and Completed FY2021)

This document is the compilation of the sampling activities associated with the FY2021 NNSA funded characterization of the 03-0016, Ion Beam facility at Los Alamos National Laboratory. Included within this document are the radiological and non-radiological sampling plans, results from the executed sampling plans, areas not sampled, summary of findings for each area sampled, and anticipated waste streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗

Contractor Support Building #7 Per- and Polyfluoroalkyl Substances (PFAS) Site Assessment Work Plan

This Work Plan documents the proposed field sampling activities for a per- and polyfluoroalkyl substances (PFAS) Site Assessment at the Contractor Support Building (CSB) #7 at Kennedy Space Center (KSC). The Work Plan provides a background of the historical activities that occurred at CSB #7, and the limited environmental investigations performed at CSB #7. The proposed Site Assessment activities at CSB #7 include the advancement of a soil lithologic boring to 60 feet below ground surface, the installation of a staff gauge in site surface water, perform direct push groundwater sampling at eight locations, and collect four surface water samples. Sampling details, depths, and locations are presented in the Work Plan. The Work Plan was presented to the KSC Remediation Team in the form of an Advance Data Package in February 2023. Following STRIVES approval, the CSB #7 PFAS Site Assessment Work Plan will be formally submitted to the Florida Department of Environmental Protection.

Howard Franklin Fowler↗

Evaluation of PM-3 Chemistry Data and Possible Interpretations of 3H Observations, Revision 0

This report summarizes the analyses of the groundwater results from sampling of PM-3-1 (deep) and PM-3-2 (shallow), with a particular focus of evaluating the groundwater geochemistry data in comparison to the geochemistry observed in other wells in the Thirsty Canyon area as well as to evaluate the potential source of 3H observed in these piezometers from previous sampling activities, which employed depth-discrete bailers or a Bennett submersible piston pump.

54 ENVIRONMENTAL SCIENCES↗

Feasibility of Metal Oxide Glasses and Polymer Membranes as Sorbents for Gaseous Oxidized Mercury

Mass spectrometry methods are currently under development by the atmospheric mercury (Hg) research community to elucidate the identity of atmospheric oxidized mercury (Hg II ) compounds. Due to high instrument detection limits, materials that can quantitatively preconcentrate atmospheric Hg II without facilitating compound-altering chemical reactions are needed to support these methods. Cation exchange membranes (CEM) and nylon membranes are currently used to preconcentrate ambient Hg II for concentration measurements and Hg II compound estimation, respectively. However, CEM and nylon membranes are poor candidates for observations by mass spectrometry methods due to release of interfering compounds upon heating; glasses do not have this problem. Here, three metal oxide glasses were explored as potential alternatives for Hg II preconcentration for future use with mass spectrometry methods: calcium phosphate (CaP), iron phosphate (FeP), and calcium aluminate (CaAl). The glasses demonstrated quantitative selective capture of HgBr 2 without capture of Hg 0 . Under ambient conditions, the CaP, FeP, and CaAl sorbed 36.4 ± 12.6% of the total HgII as the CEM. However, when Hg concentrations were normalized to surface area, CaP, FeP, and CaAl sorbed more HgBr 2 in the laboratory and ambient HgII compared to CEM. The CEM and CaP retained similar concentrations of HgBr 2 when preloaded samples were deployed in the field. Additionally, a permeation tube-based calibrator was used to load sorbents with HgBr 2 for investigation of HgII retention on CEM and thermal desorption profile changes on nylon membranes during active sampling. Nylon membranes were purchased from three vendors and used to compare HgBr 2 retention; a different HgBr 2 thermal desorption profile was achieved for each vendor’s nylon membrane.

Amides↗