Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Study of the Thermal Physical Properties of Insulating Materials in A Titan Environment

Dragonfly is a planned rotorcraft mission that NASA/APL will be sending to Saturn’s moon Titan to study its chemistry. The Dragonfly Mass Spectrometer (DraMS) is a mass spectrometer that is being developed to identify different kinds of organic material that comprises Titan’s surface. The Cryogenic engineering team on DraMS is developing and interface between the room temperature rotorcraft body and the near-cryogenic temperatures of an onboard sample chamber, while minimizing the thermal leak to the Titan environment. As part of design process, the Cryogenic team has built a conductivity test rig for testing the thermophysical properties of candidate insulators, which includes Rohacell 31HF and hollowed 3D printed PEEK structures, at simulated Titan environmental conditions.

Thermal Conductivity↗

Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent testing of meteorite and Apollo samples on micro-XRF instruments has shown that they can easily detect small zircons and phosphates (approx. 10 m), distinguish different clast lithologies within breccias, and identify different lithologies within small rock fragments (2-4 mm soil Apollo soil fragments).

Zeigler, R. A.↗

Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

Zeigler, Ryan A.↗

Investigation of Flow Conditioners for Compact Jet Engine Simulator Rig Noise Reduction

The design requirements for two new Compact Jet Engine Simulator (CJES) units for upcoming wind tunnel testing lead to the distinct possibility of rig noise contamination. The acoustic and aerodynamic properties of several flow conditioner devices are investigated over a range of operating conditions relevant to the CJES units to mitigate the risk of rig noise. An impinging jet broadband noise source is placed in the upstream plenum of the test facility permitting measurements of not only flow conditioner self-noise, but also noise attenuation characteristics. Several perforated plate and honeycomb samples of high porosity show minimal self-noise but also minimal attenuation capability. Conversely, low porosity perforated plate and sintered wire mesh conditioners exhibit noticeable attenuation but also unacceptable self-noise. One fine wire mesh sample (DP450661) shows minimal selfnoise and reasonable attenuation, particularly when combined in series with a 15.6 percent open area (POA) perforated plate upstream. This configuration is the preferred flow conditioner system for the CJES, providing up to 20 dB of broadband attenuation capability with minimal self-noise.

Doty, Michael J.↗

The Scientific Importance of Returning Airfall Dust as a Part of Mars Sample Return (MSR)

Dust transported in the martian atmosphere is of intrinsic scientific interest and has relevance for the planning of human missions in the future. The MSR Campaign, as currently designed, presents an important opportunity to return serendipitous, airfall dust. The tubes containing samples collected by the Perseverance rover would be placed in cache depots on the martian surface perhaps as early as 2023–24 for recovery by a subsequent mission no earlier than 2028–29, and possibly as late as 2030–31. Thus, the sample tube surfaces could passively collect dust for multiple years. This dust is deemed to be exceptionally valuable as it would inform our knowledge and understanding of Mars' global mineralogy, surface processes, surface-atmosphere interactions, and atmospheric circulation. Preliminary calculations suggest that the total mass of such dust on a full set of tubes could be as much as 100 mg and, therefore, sufficient for many types of laboratory analyses. Two planning steps would optimize our ability to take advantage of this opportunity: (1) the dust-covered sample tubes should be loaded into the Orbiting Sample container (OS) with minimal cleaning and (2) the capability to recover this dust early in the workflow within an MSR Sample Receiving Facility (SRF) would need to be established. A further opportunity to advance dust/atmospheric science using MSR, depending upon the design of the MSR Campaign elements, may lie with direct sampling and the return of airborne dust.

Monica M. Grady↗

Thermophysical Property Measurement and Materials Research in the NASA/MSFC Electrostatic Levitator

Containerless processing is an important tool for thermophysical property measurements and materials research. The freedom from a crucible allows processing of liquid materials in a metastable undercooled state, as well as allowing processing of high temperature and highly reactive melts. Electrostatic levitation (ESL) is a containerless method which provides a number of unique advantages, including the decoupling of positioning force from sample heating, the ability to operate in ultra-high vacuum or at moderate gas pressure (approximately 3 atm), and the ability to process non-conducting materials. ESL also has the potential to reduce internal flow velocities below those possible with electromagnetic, acoustic, or aero-acoustic techniques. The ESL facility at NASA's Marshall Space Flight Center (MSFC) is in use for thermophysical property measurements and materials research by a number of different internal and external investigators. The methods for obtaining access to the facility, as well as a summary of current capabilities and some future directions will be discussed. In electrostatic levitation, the acceleration of gravity (or residual acceleration in reduced gravity) is opposed by the action of an applied electric field on a charged sample. This positioning method is applicable to any material which can be electrically charged, whether solid or liquid, conducting, or insulating. Because the position of the sample is unstable, a 3-dimensional active control loop rapidly adjusts the applied field to maintain levitation and minimize motion of the sample. Heating lasers melt the sample, and may be adjusted to maintain specified thermal profiles. Microgravity allows electrostatic levitation to work even more effectively. With the need to cancel less than 1 milli-g, the applied field required is reduced from approximately 10 MV/m to approximately 10 kV/m. Alternatively, a microgravity ESL can position larger samples than is possible on the ground, or it can position samples which maintain their charge poorly. Microgravity also reduces the effects of buoyant convection and sedimentation. In the MSFC ESL, many different classes of experiments and measurements have been demonstrated in collaboration with many investigators. These capabilities include heat capacity measurement, phase diagram determination, and nucleation and growth experiments including nucleation rate, TTT curves, and phase selection. We have demonstrated the capability of triggering recalescence of an undercooled liquid sample without loss of levitation. Currently under development are techniques for measuring the surface tension, viscosity, and density of levitated samples, as well as other thermophysical properties. Expanded levitation capabilities including various gas environments for sample processing, sample rotation control and management of thermal gradients are under development for the MSFC ESL. Containerless processing allows research on materials which may not be processed any other way. Electrostatic levitation extends the range of containerless processing to include many materials and classes of materials which cannot be processed by conventional electromagnetic, acoustic, or aerodynamic levitation techniques.

Rogers, Jan↗

Dialysis Extraction for Chromatography

Chromatographic-sample pretreatment by dialysis detects traces of organic contaminants in water samples analyzed in field with minimal analysis equipment and minimal quantities of solvent. Technique also of value wherever aqueous sample and solvent must not make direct contact.

Jahnsen, V. J.↗

Non-Contact Conductivity Measurement for Automated Sample Processing Systems

A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

Beegle, Luther W.↗

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗

Relativistic beaming and the nuclei of double-lobed quasars

If the simple relativistic beaming model for extragalactic radio sources is at all correct, Doppler boosting may bias us toward choosing those objects pointing nearly at us in flux-density limited samples. In order to minimize any such effects in statistical tests of physical theories of these objects, an attempt is made to define a complete sample of sources with random orientations. For a sample of 26 double-lobed quasars, the dependence of a number of observable features on the angle to the line of sight and on the superluminal velocity is examined, and the distribution of superluminal velocities for the sources is measured. Two new superluminals are reported, and their apparent velocities and nuclear strengths are discussed.

Hough, David H.↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

Rodriquez, Branelle R.↗

Spectral consequences of photoreceptor sampling in the rhesus retina

Optical transforms were used to compute the power spectra of rhesus cones treated as arrays of image sampling points. Spectra were obtained for the central fovea, parafovea, periphery, and far periphery. All were consistent with a novel spatial sampling principle that introduces minimal noise for spatial frequencies below the Nyquist limits implied by local receptor densities, while frequencies above the nominal Nyquist limits are not converted into conspicuous moiree patterns, but instead are scattered into broadband noise. This sampling scheme allows the visual system to escape aliasing distortion despite a large mismatch between retinal image bandwidth and the Nyquist limits implied by extrafoveal cone densities.

Yellott, J. I., Jr.↗

SEM/XPS analysis of fractured adhesively bonded graphite fibre-reinforced polyimide composites

The surfaces of the graphite fiber-reinforced polyimide composites presently pretreated prior to bonding with polyimide adhesive contained variable amounts of a fluoropolymer, as determined by X-ray photoelectron spectroscopy. Lap shear strengths were determined for unaged samples and for those aged over 500- and 1000-hour periods at 177 and 232 C. Unaged sample lap strengths, which were the highest obtained, exhibited no variation with surface pretreatment, but a significant decrease is noted with increasing aging temperature. These thermally aged samples, however, had increased surface fluorine concentration, while a minimal concentration was found in unaged samples. SEM demonstrated a progressive shift from cohesive to adhesive failure for elevated temperature-aged composites.

Devilbiss, T. A.↗

Effect of Pressure on Trace Element Activity Coefficients in Metal-Silicate Systems

The partitioning of trace elements between metal and silicate melts serves as the foundation for understanding the differentiation of a planetary body into a metallic core and silicate mantle. Element activity influences metal-silicate partitioning behavior. Activity coefficients are directly dependent on composition and temperature, and can be indirectly dependent on oxygen fugacity and pressure. Distinguishing the effect of pressure from other variables on the activity coefficients and partitioning is important for understanding the chemical evolution of different planetary bodies during differentiation. In this study, we investigated the influence of pressure on the activity coefficients of Cu, Mo, Pd, Pt, As, Sb, and Bi in Fe-Si metallic liquids. All of these elements exhibit moderate to high activity coefficients in Fe-Si liquids at low pressure, which significantly controls their metal-silicate partitioning behavior. Identifying whether this strong dependence persists at higher pressures is critical to modeling and understanding the chemical consequences of core formation. New experiments at 10 GPa were used to derive activity coefficients for these metals which can be compared to activity coefficients determined at 1 GPa. Experiments were conducted at 10 GPa and 2373K using a 10/5 assembly in the 880-ton multi-anvil press at NASA Johnson Space Center. The standard 10/5 COMPRES assembly was slightly modified to accommodate a sample capsule machined from single-crystal MgO that minimizes melt percolation out of the sample volume during the experiment. Experiment starting materials were comprised of 70 wt.% Knippa basalt and 30 wt.% metal. The metal mixture (~85 wt.% Fe) was created by adding the elements of interest (Cu, Mo, Pd, Pt, As, Sb, Bi) to Fe metal powder. Varied amounts of Si metal (0-10 wt.% Si) were added to the metal-silicate mixtures to generate a systematic series of starting materials. For each element, an epsilon interaction parameter in Fe-Si liquid was derived from the results of our 0-10 wt.% Si metal series. To investigate whether pressure influences the trace element activity coefficients in the 1-10 GPa pressure range, we compared our results at 10 GPa to those at 1-4 GPa [1-3]. Our results can also be directly compared to interaction parameters for Au, P, V, Mn, Ga, Zn, Cd, Sn, W, Pb, and Nb previously determined at 10 GPa and 2373K following the same methods [4]. Combined, this suite of interaction parameters will directly inform metal-silicate partitioning between 1 and 10 GPa, and assess whether these values can be extrapolated to modeling differentiation processes at pressures >10 GPa.

Kelsey Prissel↗

Effect of Pressure and Oxidation State on Pnictogen Metal-Silicate Partitioning

The partitioning of trace elements between metal and silicate melts serves as the foundation for understanding the differentiation of a planetary body into a metallic core and silicate mantle. Element activity influences metal-silicate partitioning behavior. Activity coefficients are directly dependent on composition and temperature, and can be indirectly dependent on oxygen fugacity and pressure. Distinguishing the effect of pressure from other variables on the activity coefficients and partitioning is important for understanding the chemical evolution of different planetary bodies during differentiation. In this study, we investigated the influence of pressure on the activity coefficients of Cu, Mo, Pd, Pt, As, Sb, and Bi in Fe-Si metallic liquids. All of these elements exhibit moderate to high activity coefficients in Fe-Si liquids at low pressure, which significantly controls their metal-silicate partitioning behavior. Identifying whether this strong dependence persists at higher pressures is critical to modeling and understanding the chemical consequences of core formation. New experiments at 10 GPa were used to derive activity coefficients for these metals which can be compared to activity coefficients determined at 1 GPa. Experiments were conducted at 10 GPa and 2373K using a 10/5 assembly in the 880-ton multi anvil press at NASA Johnson Space Center. The standard 10/5 COMPRES assembly was slightly modified to accommodate a sample capsule machined from single-crystal MgO that minimizes melt percolation out of the sample volume during the experiment. Experiment starting materials were comprised of 70 wt.% Knippa basalt and 30 wt.% metal. The metal mixture (~85 wt.% Fe) was created by adding the elements of interest (Cu, Mo, Pd, Pt, As, Sb, Bi) to Fe metal powder. Varied amounts of Si metal (0-10 wt.% Si) were added to the metal-silicate mixtures to generate a systematic series of starting materials. For each element, an epsilon interaction parameter in Fe-Si liquid was derived from the results of our 0-10 wt.% Si metal series. To investigate whether pressure influences the trace element activity coefficients in the 1-10 GPa pressure range, we compared our results at 10 GPa to those at 1-4 GPa [1-3]. Our results can also be directly compared to interaction parameters for Au, P, V, Mn, Ga, Zn, Cd, Sn, W, Pb, and Nb previously determined at 10 GPa and 2373K following the same methods [4]. Combined, this suite of interaction parameters will directly inform metal- silicate partitioning between 1 and 10 GPa, and assess whether these values can be extrapolated to modeling differentiation processes at pressures >10 GPa. [1] Righter et al. (2018) GCA 232, 101-123 [2] Righter et al. (2019) MaPS 54, 1379-1394 [3] Steenstra et al. (2020) Icarus, 335, 113391 [4] Righter et al. (2020) Geochem. Persp. Let. 15, 44-49

Kelsey Prissel↗

Assessment of measurement error due to sampling perspective in the space-based Doppler lidar wind profiler

A Multipair Algorithm (MPA) has been developed to minimize the contribution of the sampling error in the simulated Doppler lidar wind profiler measurements (due to angular and spatial separation between shots in a shot pair) to the total measurement uncertainty. Idealized wind fields are used as input to the profiling model, and radial wind estimates are passed through the MPA to yield a wind measurement for 300 x 300 sq km areas. The derived divergence fields illustrate the gradient patterns that are particular to the Doppler lidar sampling strategy and perspective.

Houston, S. H.↗

Binomial Test Method for Determining Probability of Detection Capability for Fracture Critical Applications

The capability of an inspection system is established by applications of various methodologies to determine the probability of detection (POD). One accepted metric of an adequate inspection system is that for a minimum flaw size and all greater flaw sizes, there is 0.90 probability of detection with 95% confidence (90/95 POD). Directed design of experiments for probability of detection (DOEPOD) has been developed to provide an efficient and accurate methodology that yields estimates of POD and confidence bounds for both Hit-Miss or signal amplitude testing, where signal amplitudes are reduced to Hit-Miss by using a signal threshold Directed DOEPOD uses a nonparametric approach for the analysis or inspection data that does require any assumptions about the particular functional form of a POD function. The DOEPOD procedure identifies, for a given sample set whether or not the minimum requirement of 0.90 probability of detection with 95% confidence is demonstrated for a minimum flaw size and for all greater flaw sizes (90/95 POD). The DOEPOD procedures are sequentially executed in order to minimize the number of samples needed to demonstrate that there is a 90/95 POD lower confidence bound at a given flaw size and that the POD is monotonic for flaw sizes exceeding that 90/95 POD flaw size. The conservativeness of the DOEPOD methodology results is discussed. Validated guidelines for binomial estimation of POD for fracture critical inspection are established.

Generazio, Edward R.↗