SEARCH · Search NASA
Results for “sample minimization”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Improved sampling technique to collect natural gas from hydrate-bearing pressure cores
High quality gas compositional data are an important factor in interpreting the genetic source of natural gas hosted in hydrate-bearing sediments and other subsurface systems. In order to accurately characterize the composition of gas samples degassed from hydrate-bearing pressure cores, one must use a reproducible sampling technique that minimizes artifacts of the sampling process. Herein, we review sediment core degassing techniques and compare data obtained from a commonly used degassing approach, which we term the standard quantitative degassing (SQD) technique, to our newly developed modified quantitative degassing (MQD) method designed to minimize atmospheric contamination and gas-water interactions. The SQD method allows sample gas to interact with water in a bubbling chamber, which we hypothesize could alter the gas composition following mixing with water or dissolved gases in the bubbling chamber. Whereas, the MQD method allows for the collection of sample gas prior to the bubbling chamber. To compare the SQD and MQD methods, we performed a side-by-side comparison of noble (He, Ne, Ar, Kr, and Xe), major (H 2 , N 2 , O 2 , and CO 2 ), and hydrocarbon (CH 4 , C 2 H 6 , C 3 H 8 , i-C 4 H 10 , C 4 H 10 , i-C 5 H 12 , C 5 H 12 ) gas concentrations and select isotopic compositions obtained using both sample collection techniques. Gas samples were collected from hydrate-bearing pressure cores recovered and maintained under hydrate stable conditions from the northern Gulf of Mexico during the UT-GOM 2 -1 Expedition. The MQD method displayed significantly lower concentrations of atmospheric gases, higher proportions of hydrocarbon gases, lower ratios of C 1 /C 2 + , and heavier stable carbon and hydrogen isotopes of methane than the SQD method. These results demonstrate that the MQD method reduced air contamination and minimized alteration of the hydrocarbon gases. Finally, we conclude this method may be important for future work that seeks to determine the composition of natural gas from pressure cores using quantitative degassing experiments, especially those seeking to measure major (e.g., N 2 ) and noble gases.
Infrared quantum ghost imaging of living and undisturbed plants
Quantum ghost imaging (QGI) is a method that measures absorption at extremely low light intensities. Nondegenerate QGI probes a sample at one wavelength while forming an image with correlated photons at a different wavelength. This spectral separation alleviates the need for imaging detectors with high sensitivity in the near-infrared (NIR) region, thereby reducing the required illumination intensity. Using NCam, a single-photon detector, we demonstrated nondegenerate QGI with unprecedented sensitivity and contrast, obtaining images of living plants with less than 1% light transmission. The plants experienced 3aW/cm 2 of light during imaging, orders of magnitude below starlight. This realization of QGI expands the method to extremely low-light bioimaging and imaging of light-sensitive samples, where minimizing illumination intensity is crucial to prevent phototoxicity or sample degradation.
Molten Salt Sampling Techniques and Analytical Approaches
Recent global interest in pyroprocessing and molten salt reactors has brought salt sampling methods and techniques back to the forefront of nuclear safeguards concerns. Issues with uranium supplies have also encouraged various countries to pursue advanced nuclear fuel cycles. Tracking nuclear material in molten salt has proven to be a challenge and updating molten salt sampling will greatly help in this endeavor. Molten salt is problematic to sample due to salt stratification, lack of homogeneity, solids, and difficulty with hot cell adaptations. Various salt sampling techniques have been used since before the 1960s including surface, spoon/spatula, and bar solidification. Since then, new types of sampling techniques have been developed to improve sampling results. These include rod/dip, pipet, suction, filtered sampling along with devices such as the Valve Core Sampler and the Multi-Level Sampler. These different approaches are being analyzed and improved upon along with developing requirements for an improved salt sampling device. Work continues to develop salt samplers that are more robust, easier to segment, collect at a specific depth, can work with filters, and can collect fines. Sampling parameters are also being narrowed in terms of stirring, settling time, filtration, depth, etc. In the future, we hope to address deficiencies for process control and nuclear material accountancy control by determining the best way to collect samples that minimizes contaminants and is representative. A compilation of salt sampling approaches, analyses techniques, and an evaluation of findings will be presented.
Note: A method for minimizing oxide formation during elevated temperature nanoindentation
A standardized method to protect metallic samples and minimize oxide formation during elevated-temperature nanoindentation was adapted to a commercial instrument. Nanoindentation was performed on Al (100), Cu (100), and W (100) single crystals submerged in vacuum oil at 200 °C, while the surface morphology and oxidation was carefully monitored using atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The results were compared to room temperature and 200 °C nanoindentation tests performed without oil, in order to evaluate the feasibility of using the oil as a protective medium. Extensive surface characterization demonstrated that this methodology is effective for nanoscale testing.
Cholesky-based experimental design for Gaussian process and kernel-based emulation and calibration.
Gaussian processes and other kernel-based methods are used extensively to construct approximations of multivariate data sets. The accuracy of these approximations is dependent on the data used. This paper presents a computationally efficient algorithm to greedily select training samples that minimize the weighted L p error of kernel-based approximations for a given number of data. The method successively generates nested samples, with the goal of minimizing the error in high probability regions of densities specified by users. The algorithm presented is extremely simple and can be implemented using existing pivoted Cholesky factorization methods. Training samples are generated in batches which allows training data to be evaluated (labeled) in parallel. For smooth kernels, the algorithm performs comparably with the greedy integrated variance design but has significantly lower complexity. Numerical experiments demonstrate the efficacy of the approach for bounded, unbounded, multi-modal and non-tensor product densities. We also show how to use the proposed algorithm to efficiently generate surrogates for inferring unknown model parameters from data using Bayesian inference.
A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors
The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.
The use of commercial and industrial waste in energy recovery systems - A UK preliminary study
Highlights: > Commercial and industrial waste samples collected. > Samples analysed for calorific value, moisture, ash and elemental composition. > Values similar to those of municipal solid waste and refuse derived fuel. > Sampled waste could be used in current energy recovery systems with minimal retrofitting. > Sampled waste could account 6.5% towards the UK's 2020 renewable electricity target if all qualifying waste is used. - Abstract: With 2020 energy targets set out by the EU fast approaching, the UK is trying to source a higher proportion of its energy from renewable resources. Coupled with this, a growing population and increasing trends in consumer demand have resulted in national waste loads increasing. A possible solution to both issues is energy-from-waste (EfW) technologies. Many studies have focused on municipal solid waste (MSW) as a potential feedstock, but appear to overlook the potential benefits of commercial and industrial waste (C and IW). In this study, samples of C and IW were collected from three North West waste management companies and Lancaster University campus. The samples were tested for their gross and net calorific value, moisture content, ash content, volatile matter, and also elemental composition to determine their suitability in EfW systems. Intra-sample analysis showed there to be little variation between samples with the exception two samples, from waste management site 3, which showed extensive variation with regards to net calorific value, ash content, and elemental analysis. Comparisons with known fuel types revealed similarities between the sampled C and IW, MSW, and refuse derived fuel (RDF) thereby justifying its potential for use in EfW systems. Mean net calorific value (NCV) was calculated as 9.47 MJ/kg and concentrations of sulphur, nitrogen, and chlorine were found to be below 2%. Potential electrical output was calculated using the NCV of the sampled C and IW coupled with four differing energy generation technologies. Using a conventional incinerator with steam cycle, total electrical output was calculated as 24.9 GWh, based on a plant operating at 100,000 tpa. This value rose to 27.0 GWh when using an integrated gasification combined cycle. A final aspect of this study was to deduce the potential total national electrical output if all suitable C and IW were to be used in EfW systems. Using incineration coupled with a steam turbine, this was determined to be 6 TWh, 1.9% of the national demand thereby contributing 6.5% towards the UK's 2020 renewable electricity target.
Chemometrics and Experimental Design for the Quantification of Nitrate Salts in Nitric Acid: Near-Infrared Spectroscopy Absorption Analysis
Implementing remote, real-time spectroscopic monitoring of radiochemical processing streams in hot cell environments requires efficiency and simplicity. The success of optical spectroscopy for the quantification of species in chemical systems highly depends on representative training sets and suitable validation sets. Selecting a training set (i.e., calibration standards) to build multivariate regression models is both time- and resource-consuming using standard one-factor-at-a-time approaches. This study describes the use of experimental design to generate spectral training sets and a validation set for the quantification of sodium nitrate (0–1 M) and nitric acid (0.1–10 M) using the near-infrared water band centered at 1440 nm. Partial least squares regression models were built from training sets generated by both D- and I-optimal experimental designs and a one-factor-at-a-time approach. The prediction performance of each model was evaluated by comparing the bias and standard error of prediction for statistical significance. D- and I-optimal designs reduced the number of samples required to build regression models compared with one-factor-at-a-time while also improving performance. Models must be confirmed against a validation sample set when minimizing the number of samples in the training set. The D-optimal design performed the best when considering both performance and efficiency by improving predictive capability and reducing number of samples in the training set by 64% compared with the one-factor-at-a-time approach. The experimental design approach objectively selects calibration and validation spectral data sets based on statistical criterion to optimize performance and minimize resources.
Importance sampling variance reduction for the Fokker–Planck rarefied gas particle method
The Fokker–Planck approximation to the Boltzmann equation, solved numerically by stochastic particle schemes, is used to provide estimates for rarefied gas flows. This paper presents a variance reduction technique for a stochastic particle method that is able to greatly reduce the uncertainty of the estimated flow fields when the characteristic speed of the flow is small in comparison to the thermal velocity of the gas. The method relies on importance sampling, requiring minimal changes to the basic stochastic particle scheme. We test the importance sampling scheme on a homogeneous relaxation, planar Couette flow and a lid-driven-cavity flow, and find that our method is able to greatly reduce the noise of estimated quantities. Significantly, we find that as the characteristic speed of the flow decreases, the variance of the noisy estimators becomes independent of the characteristic speed.
Quantitative Encapsulation and Homogeneity Assessment of Sol–Gel Based Nuclear Explosive Debris Simulants
Nuclear explosive debris simulants are an important material in training and validating aspects of post-detonation nuclear forensic processes. Realistic simulants should replicate several aspects of nuclear explosive debris such as the size, shape, color, density, and chemical and radiological properties. Silica particles produced via sol-gel synthesis have recently been found to successfully reproduce many of these parameters including the controllable incorporation of radionuclide content. However, to be useful as a benchmarking material for validation and verification of laboratory methodologies, radionuclide content from batch-to-batch must be reproducible. Here, in this work, we explore the variance in radionuclide distribution incorporated into sol-gel benchmarking materials with respect to sample subdivision. Results will help inform the sample sizes required to minimize variance between samples.
Trapping ultracold gases near cryogenic materials with rapid reconfigurability
We demonstrate an atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any ≲100 μm-thin, UHV-compatible material, while also allowing sample exchange with minimal experimental downtime. The sample is not connected to the atom chip, allowing rapid exchange without perturbing the atom chip or laser cooling apparatus. Exchange of the sample and retrapping of atoms has been performed within a week turnaround, limited only by chamber baking. Moreover, the decoupling of sample and atom chip provides the ability to independently tune the sample temperature and its position with respect to the trapped ultracold gas, which itself may remain in the focus of a high-resolution imaging system. As a first demonstration of this system, we have confined a 700-nK cloud of 8 × 10{sup 4} {sup 87}Rb atoms within 100 μm of a gold-mirrored 100-μm-thick silicon substrate. The substrate was cooled to 35 K without use of a heat shield, while the atom chip, 120 μm away, remained at room temperature. Atoms may be imaged and retrapped every 16 s, allowing rapid data collection.
SISGR: Atom chip microscopy: A novel probe for strongly correlated materials
Microscopy techniques co-opted from nonlinear optics and high energy physics have complemented solid-state probes in elucidating the order manifest in condensed matter materials. Up until now, however, no attempts have been made to use modern techniques of ultracold atomic physics to directly explore properties of strongly correlated or topologically protected materials. Our current program is focused on introducing a novel magnetic field microscopy technique into the toolbox of imaging probes. Our prior DOE ESPM program funded the development of a novel instrument using a dilute gas Bose-Einstein condensate (BEC) as a scanning probe capable of measuring tiny magnetic (and electric) DC and AC fields above materials. We successfully built the world's first “scanning cryogenic atom chip microscope”, and we now are in the process of characterizing its performance before using the instrument to take the first wide-area images of transport flow within unconventional superconductors, pnictides and oxide interfaces (LAO/STO), topological insulators, and colossal magnetoresistive manganites. We will do so at temperatures outside the capability of scanning SQUIDs, with ~10x better resolution and without 1/f-noise. A notable goal will be to measure the surface-to-bulk conductivity ratio in topological insulators in a relatively model-independent fashion. We have completed the construction of this magnetic microscope. The instrument uses atom chips—substrates supporting micron-sized current-carrying wires that create magnetic microtraps near surfaces for ultracold thermal gases and BECs—to enable single-shot and raster-scanned large-field-of-view detection of magnetic fields. The fields emanating from electronic transport may be detected at the 10 -7 flux quantum (Φ0) level and below; that is, few to sub-micron resolution of sub-nanotesla fields over single-shot, millimeter-long detection lengths. By harnessing the extreme sensitivity of atomic clocks and BECs to external perturbations, we are now in a position to use atom chips for imaging transport in new regimes. Scanning quantum gas atom chip microscopy introduces three very important features to the toolbox of high-resolution scanning microscopy of strongly correlated or topological materials: simultaneous detection of magnetic and electric fields (down to the sub-single electron charge level; no invasive large magnetic fields or gradients; simultaneous micro- and macroscopic spatial resolution; DC to MHz detection bandwidth; freedom from 1/ƒ flicker noise at low frequencies; and, perhaps most importantly, the complete decoupling of probe and sample temperatures. The atom chip microscope can operate at maximum sensitivity and resolution without regard to the substrate temperature. While the BEC is among the coldest objects realizable (100 nK temperatures are typical), the atom chip substrate can be positioned 1 μm away from the BEC and be as hot as 400 K or as cold as the cryostat can cool. This is because unlike superconducting probes, whose temperature is closely coupled to nearby materials, quantum gases are immune to radiative heating. The energy gap between a Rb atom’s ground state and first excited state far exceeds the typical energy of room-temperature blackbody radiation; such atoms are therefore transparent to radiation heating by materials at room temperature or below. We experimentally demonstrated a new atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any ≤100 μm-thin, UHV-compatible material, while also allowing sample exchange with minimal experimental downtime. The sample is not connected to the atom chip, allowing rapid exchange without perturbing the atom chip or laser cooling apparatus. Exchange of the sample and retrapping of atoms has been performed within a week turnaround, limited only by chamber baking. Moreover, the decoupling of sample and atom chip provides the ability to independently tune the sample temperature and its position with respect to the trapped ultracold gas, which itself may remain in the focus of a high-resolution imaging system. We confine 100-nK BECs of 104 87Rb atoms near a gold-mirrored 100-μm-thick silicon substrate. The substrate can be cooled to 35 K without use of a heat shield, while the atom chip, 120-μm away, remains at room temperature. Atoms may be imaged with 1-μm resolution and retrapped every 16 s, allowing rapid data collection. Straightforward improvements will allow us to push sample temperatures close to 4 K, and improve imaging resolution from 1 μm down to a few-100 nm, thereby providing 10 -9 Φ0 detection sensitivity. We will test the utility of this technique by imaging the magnetic fields emanating from electronic transport and domain percolation in several interesting examples of strongly correlated or topologically protected materials. STM, transport, and x-ray scattering experiments have, among others, revealed the existence of a quantum liquid crystal state in iron (pnictide) and cuprate superconductors. This strongly correlated state of matter could also be detected by imaging the fluctuating transport (spatially and in time) of electrons as the phase/regime boundary is crossed between the pnictide non-Fermi liquid (cuprate strange metal) and the pnictide magnetic phase (cuprate pseudogap regime). Our ability to image wide-area inhomogeneous current flow from room-temperature to <10 K will allow us to study the developing domain structure and transport near twin boundary interfaces through the T N ≈50–150 K nematic transition recently identified in bulk transport experiments by Ian Fisher's group in underdoped Fe-arsinide superconductors. Again, this highlights a main feature of our cryogenic atom chip microscope: the ability to image transport regardless of the sample temperature since the BEC, at nK temperatures, is transparent to blackbody radiation, even when held a microns from the surface.
Slow Magic Angle Sample Spinning: A Non- or Minimally Invasive Method for High- Resolution 1H Nuclear Magnetic Resonance (NMR) Metabolic Profiling
High resolution 1H magic angle spinning nuclear magnetic resonance (NMR), using a sample spinning rate of several kHz or more (i.e., high resolution-magic angle spinning (hr-MAS)), is a well established method for metabolic profiling in intact tissues without the need for sample extraction. The only shortcoming with hr-MAS is that it is invasive and is thus unusable for non-destructive detections. Recently, a method called slow-MAS, using the concept of two dimensional NMR spectroscopy, has emerged as an alternative method for non- or minimal invasive metabolomics in intact tissues, including live animals, due to the slow or ultra-slow-sample spinning used. Although slow-MAS is a powerful method, its applications are hindered by experimental challenges. Correctly designing the experiment and choosing the appropriate slow-MAS method both require a fundamental understanding of the operation principles, in particular the details of line narrowing due to the presence of molecular diffusion. However, these fundamental principles have not yet been fully disclosed in previous publications. The goal of this chapter is to provide an in depth evaluation of the principles associated with slow-MAS techniques by emphasizing the challenges associated with a phantom sample consisting of glass beads and H2O, where an unusually large magnetic susceptibility field gradient is obtained.
Ultrathin aluminum sample cans for single crystal inelastic neutron scattering
Single crystal inelastic neutron scattering measurements are often performed using a sample environment for controlling sample temperature. One difficulty associated with this is establishing appropriate thermal coupling from the sample to the temperature controlled portion of the sample environment. This is usually accomplished via a sample can which thermally couples the sample environment to the sample can and the sample can to the sample via an exchange gas. Unfortunately, this can will contribute additional background signal to ones measurement. We present here the design of an ultrathin aluminum sample can based upon established technology for producing aluminum beverage cans. This design minimizes parasitic sample can scattering. Neutron scattering measurements comparing a machined sample can to our beverage can design clearly indicate a large reduction in scattering intensity and texture when using the ultrathin sample can design. We also examine the possibility of using standard commercial beverage cans as sample cans.
In-situ study of the crystallization of amorphous CuInSe2 thin films and the effect of InCl3 treatment
Not provided.
Investigating Sintering Mechanisms for Additive Manufacturing of Conductive Traces
Additive Manufacturing (AM) processes enable the fabrication of miniaturized and flexible devices on complex geometries. This paper explores a hybrid additive manufacturing technology that integrates micro-extrusion and PICO-jetting methods. Conductive slurries and colloidal inks were optimized for their rheological properties to aid their precise deposition. A variety of conductive materials which include carbon, silver, nano-particle silver and nickel were deposited on both rigid (glass) and flexible (Kapton) substrates. The deposited traces were cured using two sintering mechanisms which include furnace heating and in situ laser irradiation. The effect of curing mechanism on the conductance of deposited traces was evaluated. The results indicated that traces could be cured successfully with the laser curing mechanism. Nickel and silver laser cured traces had lower resistivity than the furnace sintered traces. An increase in the laser power resulted in lower resistivity of the traces. The lowest resistivity was achieved at 40W laser power with a single laser pass. Scanning electron microscopy and energy dispersive spectroscopy were used to characterize the trace morphology and elemental compositions. Higher power laser curing resulted in better bonding of the particles. Laser cured samples had minimal oxidation to the cross-section region of the traces as compared to furnace cured samples. Furthermore, this research lays the foundation for the fabrication of electronic components for a high level of freeform 3D electronics using a hybrid additive manufacturing technology.
Analysis of furnace contamination on superconducting radio frequency niobium using secondary-ion mass spectrometry
Detection of surface contamination on niobium materials used in superconducting radio frequency (SRF) applications is difficult due to quantitative sensitivity and near-atomic depth resolution needed. Inspection of samples known to have experienced surface contamination was found to have inconsistent nitride coverage after high-temperature nitrogen gas exposure (“doping”). Here we compare contaminating species found on samples treated in several different vacuum furnaces, both “exposed” directly in the chamber and “protected” by containment shielding from evaporative sources with “furnace caps.” Typically, furnace caps are used to impede contamination from reaching the interior surface of cavities during the high-temperature vacuum bake that immediately precedes exposure to nitrogen gas. Although, to date, little is known about the effectiveness of these caps, SIMS results showed that they were effective in limiting contamination arising from the furnace environment. Inspection of sample surfaces by SEM showed a lack of nitrides present on contaminated specimens. TEM with energy dispersive spectroscopy performed on these samples revealed that a carbon-rich layer now existed, indicating that a relatively high contaminant load prevents the nucleation and growth of surface nitrides, while thus inhibiting interstitial nitrogen uptake. Except in extreme cases, subsequent removal of the top several micrometers of the surface via electropolishing appears to effectively eliminate any strong influence on the subsequent SRF cavity performance. With the absence of furnace cleaning, carbon contamination was found to be nearly 10× higher for protected nitrogen-doped and electropolished samples, with minimal metallic contamination detected for both processes. SIMS analysis was also performed to compare the cleanliness of samples fully prepared by such nitrogen “doping” with those prepared by a related process, involving the dissolution of niobium surface oxide and diffusion of oxygen into the surface. This oxygen doping or alloying process offers attractive advantages.