Search NASA⌕ Search

SEARCH · Search NASA

Results for “scanner”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Discriminant analyses of Bendix scanner data

Flights over Weslaco, Texas are discussed, using the 9-channel Bendix scanner, providing calibrated data in the 380 to 1000 nm wavelength interval. These flights were at 2000 ft. These data gave seasonal coverage from the time signals, representing mainly the soil background. The ground truth data are provided; signature processing studies relating scanner data to ground truth were also carried out.

Richardson, A. J.↗

An orbiting multispectral scanner for overland and oceanographic applications.

Description of the major features of a multispectral scanner designed to perform overland and oceanographic surveys from space. The instrument uses an image plane conical scanner and contains independent spectrometers for land and ocean applications. The overland spectrometer has a spatial resolution of 200 ft and has six spectral bands in the atmospheric windows between 0.5 and 2.4 microns. The oceanographic spectrometer has a spatial resolution of 1200 ft and possesses 24 spectral bands equally spaced and in registration over the wavelength range from 0.4 to 0.8 micron. A thermal band of 600-ft resolution is used with a spectral range from 10.5 to 12.6 microns. The swath width of the scan is 100 nautical miles from an altitude of 500 nautical miles. The system has two modes of operation which are selectable by ground command. The six bands of overland data plus the thermal band data can be transmitted, or the 24 bands of oceanographic data plus data from two of the overland bands and the thermal band can be transmitted. The performance is described by the minimum detectable reflectance difference and the effects of sun angle and target reflectivity variations are discussed. The sensitivity is related to the variation of the ocean reflectivity in the presence of chlorophyll and to typical agricultural targets.

Peacock, K.↗

Preprocessing techniques to reduce atmospheric and sensor variability in multispectral scanner data.

Multispectral scanner data are potentially useful in a variety of remote sensing applications. Large-area surveys of earth resources carried out by automated recognition processing of these data are particularly important. However, the practical realization of such surveys is limited by a variability in the scanner signals that results in improper recognition of the data. This paper discusses ways by which some of this variability can be removed from the data by preprocessing with resultant improvements in recognition results.

Crane, R. B.↗

URSIES - An ultravariable resolution single interferometer echelle scanner.

Use of a Fabry-Perot interferometer in a Ramsay mount in tandem with an echelle Hilger monochromator with pinholes instead of slits. The instrument, URSIES, is enclosed within a pressure chamber filled with Freon. Photoelectric pulse counting techniques and pressure scanning are used to record the spectrum. This design has four basic advantages: (1) the resolution of the scanner is variable from 5.0 to 0.005 A, and the effective wavelength range is quite broad, from 3500 to 13,000 A; (2) a light gain of ten over conventional grating scanners at resolutions of 0.1 A or better is achieved; (3) very low levels of light from outside the wavelength passband reach the detector; for a resolution of 0.03 A at 6000 A this level is 5%; and (4) there are very low levels of scattered light from the pinholes when extended sources are observed. The scattered light from the instrument at the edge of the solar disk is found to be less than 1% from 4000 to 11,000 A. Measurements demonstrating these advantages are discussed.

Wyller, A. A.↗

Radiation balance mapping with multispectral scanner data.

Energy budget and radiation balance relationships have been measured from the ground by investigators in several disciplines. Airborne and spaceborne multispectral sensors provide a new measurement capability for large-area synoptic mapping of these quantities. Procedures for estimating and mapping total exitance and radiation balance from multispectral scanner data are discussed, and example maps for an agricultural application are presented. This information extraction technique is an extension of the usual recognition mapping performed with multispectral scanner data, and represents a first step in the quantitative interpretation and assessment of surface conditions with remote sensor data.

Malila, W. A.↗

An ERTS multispectral scanner experiment for mapping iron compounds.

An experiment is described which is designed to produce visible-reflective infrared ratio images from ERTS satellite data. The ERTS-A multispectral scanner has two channels in the visible-reflective infrared wavelength region which should be capable of duplicating aircraft scanner results. The average reflectances in the four ERTS-A MSS spectral bands for a few minerals and some vegetation are tabulated. The mineral laboratory samples were granular, with a particle diameter range of 250 to 1200 micrometer. If there were no spectral atmospheric or illumination variation effects, the ratio of energies in band 1 to band 4 would permit discrimination of pyroxenes (found in basic and ultrabasic rocks), quartz (found in acidic rocks), limonite and hematite (iron oxides), and green vegetation, on the basis of their respective ratio magnitudes.

Vincent, R. K.↗

Multispectral scanner imagery for plant community classification.

Optimum channel selection among 12 channels of multispectral scanner imagery identified six as providing the best information for computerized classification of 11 plant communities and two nonvegetation classes. Intensive preprocessing of the spectral data was required to eliminate bidirectional reflectance effects of the spectral imagery caused by scanner view angle and varying geometry of the plant canopy. Generalized plant community types - forest, grassland, and hydrophytic systems - were acceptably classified based on ecological analysis. Serious, but soluble, errors occurred with attempts to classify specific community types within the grassland system. However, special clustering analyses provided for improved classification of specific grassland communities.

Driscoll, R. S.↗

Bone mineral computation with a rectilinear scanner

A portable rectilinear transmission scanner and associated computerized data reduction techniques for estimating bone mineral content are described. This unit can be easily disassembled for transport to various measurement sites and has been used to estimate the bone mineral content of the os calcis, radius, and ulna in the Apollo and Skylab astronauts. The scanner is used to obtain multiple rows of data from which a bone profile is derived. Bone edges are determined with the aid of a digital computer program which employs an algorithm that determines the greatest rate of change of the counting rate.

Ullman, J.↗

A procedure for automated land use mapping using remotely sensed multispectral scanner data

A system of processing remotely sensed multispectral scanner data by computer programs to produce color-coded land use maps for large areas is described. The procedure is explained, the software and the hardware are described, and an analogous example of the procedure is presented. Detailed descriptions of the multispectral scanners currently in use are provided together with a summary of the background of current land use mapping techniques. The data analysis system used in the procedure and the pattern recognition software used are functionally described. Current efforts by the NASA Earth Resources Laboratory to evaluate operationally a less complex and less costly system are discussed in a separate section.

Whitley, S. L.↗

The four- and five-band multispectral scanners for Landsat

The earth resources sensing Multispectral Scanner (MSS) for the Landsat satellite has two versions; one with four spectral bands from 0.5 to 1.1 microns, and one with five bands, the added band being 10.4 to 12.6 microns. This paper describes optical design and performance. The instrument uses a flat, object-space scanning mirror of near-linear motion, with a sensitive optical position monitor to detect mirror angular position. The 22.9-cm aperture telescope images the scene on an array of fiber optics, which dissect and transmit the scene energy to photomultiplier tubes detecting in Bands 1, 2, and 3, and silicon photodiodes detecting Band 4. Band 5 energy passes the fiber optic assembly and is reimaged on a radiatively cooled mercury cadmium telluride (HgCdTe) detector. The orbiting four-band scanner is furnishing data registered to better than 50-m band-to-band and resolving 80-m repetitive pattern over a 185-km swath width from 907-km altitude.

Lansing, J. C., Jr.↗

A report on the use of thermal scanner data in an operational program for monitoring apparent rooftop temperatures

CENGAS, a division of Central Telephone and Utilities Corporation in cooperation with the Remote Sensing Institute, South Dakota State University, is using airborne thermal scanner data to monitor relative rooftop temperatures. Four Nebraska communities and one South Dakota community were surveyed by the Remote Sensing Institute for CENGAS. Thermal scanner data were converted to a film format and the resultant imagery has been successfully employed by CENGAS. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorklund, J.↗

An empirical study of scanner system parameters

The selection of the current combination of parametric values (instantaneous field of view, number and location of spectral bands, signal-to-noise ratio, etc.) of a multispectral scanner is a complex problem due to the strong interrelationship these parameters have with one another. The study was done with the proposed scanner known as Thematic Mapper in mind. Since an adequate theoretical procedure for this problem has apparently not yet been devised, an empirical simulation approach was used with candidate parameter values selected by the heuristic means. The results obtained using a conventional maximum likelihood pixel classifier suggest that although the classification accuracy declines slightly as the IFOV is decreased this is more than made up by an improved mensuration accuracy. Further, the use of a classifier involving both spatial and spectral features shows a very substantial tendency to resist degradation as the signal-to-noise ratio is decreased. And finally, further evidence is provided of the importance of having at least one spectral band in each of the major available portions of the optical spectrum.

Landgrebe, D.↗

Infrared scanners for temperature measurement in wind tunnels

Remote infrared scanners allow large surfaces to be studied without disturbing model and without extensive sensor installation. Computer techniques analyze data with accuracy of + or - 5 percent. Scanners are applicable to tracking and diffusion studies of rocket exhausts, nondestructive testing of rocket motor nozzles and composite materials, and detection of nonuniformity in home insulation.

Kantsios, A. G.↗

Quantitative analysis of aircraft multispectral-scanner data and mapping of water-quality parameters in the James River in Virginia

Statistical analysis techniques were applied to develop quantitative relationships between in situ river measurements and the remotely sensed data that were obtained over the James River in Virginia on 28 May 1974. The remotely sensed data were collected with a multispectral scanner and with photographs taken from an aircraft platform. Concentration differences among water quality parameters such as suspended sediment, chlorophyll a, and nutrients indicated significant spectral variations. Calibrated equations from the multiple regression analysis were used to develop maps that indicated the quantitative distributions of water quality parameters and the dispersion characteristics of a pollutant plume entering the turbid river system. Results from further analyses that use only three preselected multispectral scanner bands of data indicated that regression coefficients and standard errors of estimate were not appreciably degraded compared with results from the 10-band analysis.

Johnson, R. W.↗

Optical scanner

An optical scanner that sequentially focuses optical energy (light) at selected points in space is described. The essential component is a scanning wheel including several glass windows with each window having a different thickness. Due to this difference in thickness, the displacement of the emerging light from the incident light is different for each window. The scanner transmits optical energy to a point in space while at the same time receiving any optical energy generated at that point and then moves on to the next selected point and repeats this transmit and receive operation. It fills the need for a system that permits a laser velocimeter to rapidly scan across a constantly changing flow field in an aerodynamic test facility.

Rhodes, D. B.↗

Investigation of a high speed data handling system for use with multispectral aircraft scanners

A buffer memory data handling technique for use with multispectral aircraft scanners is presented which allows digital data generated at high data rates to be recorded on magnetic tape. A digital memory is used to temporarily store the data for subsequent recording at slower rates during the passive time of the scan line, thereby increasing the maximum data rate recording capability over real-time recording. Three possible implementations are described and the maximum data rate capability is defined in terms of the speed capability of the key hardware components. The maximum data rates can be used to define the maximum ground resolution achievable by a multispectral aircraft scanner using conventional data handling techniques.

Kelly, W. L.↗