Search NASA⌕ Search

SEARCH · Search NASA

Results for “scenario data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Applying a Multisector Scenario Framework to Evaluate Past and Future Public Surface Water Supply Infrastructure Strategies in Texas

Datasets supporting the index model and scenario analysis used in evaluating surface water supply strategies across different water system types in Texas. These data underpin the scenario development and application of five key indicators: Water Availability Index (WAI), Water Quality Index (WQI), Energy Requirement Index (ERI), Water Treatment Cost (WTC), and Water Infrastructure Cost (WIC). The datasets are organized by system type—stream reaches (flowlines), waterbodies, and reservoirs—and include both raw and standardized index values. The integrated datasets also provide scenario classifications (original and adjusted) based on infrastructure and planning priorities, enabling comparison across Shared Socioeconomic Pathways (SSPs). Additional strategy-level data are included to support evaluation of state-level new reservoir projects in relation to cost and availability tradeoffs. Please refer to the README file provided in Files for more details. Descriptions of the datasets are provided below. Dataset(s) Descriptions Folder: Index_model_database.zip Subfolder: Stream_reach.zip Fl_wf.csv, Fl_wq.csv, Fl_er.csv, Fl_wf_wtcUV.csv, Fl_wf_wtcnoUV.csv, Fl_allfac_wic1.csv, Fl_allfac_wic2.csvDatasets for computing WAI, WQI, ERI, WTC, and WIC for surface water systems classified as stream reaches (flowlines). Subfolder: Waterbody.zip Wb_wf.csv, Wb_wq.csv, Wb_er.csv, Wb_wf_wtcUV.csv, Wb_wf_wtcnoUV.csv, Wb_allfac_wic1.csv, Wb_allfac_wic2.csvEquivalent index model datasets for waterbodies, reflecting hydrologic and infrastructure attributes specific to impounded natural systems. Subfolder: Reservoir.zip Rs_wf.csv, Rs_wq.csv, Rs_er.csv, Rs_wf_wtcUV.csv, Rs_wf_wtcnoUV.csv, Rs_allfac_wic1.csv, Rs_allfac_wic2.csvIndex model datasets specific to regulated reservoir systems, incorporating both resource indicators and cost parameters. Folder: Integrated data.zip combined_merged_data.csv, combined_merged_data_scenario.csvDatasets integrating index model indicators (both raw and scaled) with scenario classifications, including adjustments reflecting SSP-aligned transitions and planning shifts. Folder: Additional data.zip wai_supplystrat_wic_merged.csvCurated dataset capturing proposed major reservoir-based municipal water supply strategies in Texas. Integrates site-level planning data with estimated capital infrastructure costs and water availability scores for comparative assessment.

geospatial↗

IM3 Data Center Driven Grid Stress Dataset for the U.S. Western Interconnection

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from an open-source grid operations modeling framework - GO), for the Integrated Multisector, Multiscale Modeling (IM3) project, under varying levels of data center demand growth between 2025 and 2035 in the U.S. Western Interconnection. The scenarios and sensitivity experiments are combinations of different data center demand growth rates and energy, weather, population and economic pathways. Data center demand growth projections were sourced from the Electric Power Research Institute (EPRI). The data center demand growth projection names are: Low (3.71% annual data center demand growth) Moderate (5% annual data center demand growth) High (10% annual data center demand growth) Higher (15% annual data center demand growth) Energy, weather, population and economic pathways are informed by two Shared Socioeconomic Pathways (SSP3 and SSP5) and two Representative Concentration Pathways (RCP4.5 and RCP8.5) following the hotter general circulation model (GCM) forcing group from a set of perturbed thermodynamics simulations. The resulting pathway names are: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The main scenarios and sensitivity experiments are detailed below. Reference scenario: The projected grid stress and reliability results for the U.S. Western Interconnection from a previous study. This scenario does not consider data center demand growth explicitly. Data center scenario: Building on the reference scenario, this scenario considers various data center growth rates and how they impact the U.S. Western Interconnection. Data center loads are modeled as flat 8760-hr profiles. This scenario does not consider new generation and transmission capacities specifically designed to meet the new data center demands. The related folder is named "flat". Delayed generator retirements sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different levels of natural gas and nuclear generator retirement delays. The resulting scenario names are: (1) postponing 100% nuclear retirements; (2) postponing 100% nuclear and 25% natural gas retirements; (3) postponing only 50% natural gas retirements; (4) postponing 100% nuclear and 50% natural gas retirements; (5) postponing 100% nuclear and 75% natural gas retirements; and (6) postponing 100% nuclear and 100% natural gas retirements. The related folder names are: no_gen_retire_0_gas, no_gen_retire_25_gas, no_gen_retire_50_gas, no_gen_retire_50_gas_only, no_gen_retire_75_gas, and no_gen_retire_100_gas. Demand response through curtailment sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different participation and compensation levels of data center demand response. The resulting scenario names are: (1) 5% demand available for curtailment with 750 $/MWh compensation; (2) 5% demand available for curtailment with 500 $/MWh compensation; (3) 5% demand available for curtailment with 250 $/MWh compensation; (4) 15% demand available for curtailment with 750 $/MWh compensation; (5) 15% demand available for curtailment with 500 $/MWh compensation; and (6) 15% demand available for curtailment with 250 $/MWh compensation. The related folder names are: dr_cost_250_drup_0_drdown_5, dr_cost_250_drup_0_drdown_15, dr_cost_500_drup_0_drdown_5, dr_cost_500_drup_0_drdown_15, dr_cost_750_drup_0_drdown_5, and dr_cost_750_drup_0_drdown_15. Combination of delayed generator retirements and demand response through curtailment sensitivity experiment: The impact of combining postponing 100% nuclear and 25% natural gas retirements with 5% demand available for curtailment with 750 $/MWh compensation is simulated. The related folder is named "dr_cost_750_drup_0_drdown_5_nuc_100_gas_25". Please refer to the README file for a detailed description of the dataset including individual files and references.

Artificial Intelligence↗

Towards a Robust Adaptive Digital Twin for Fusion Applications

The development of a digital twin system for fusion applications is essential for enhancing the prediction, analysis, and optimization of complex plasma processes. Machine learning (ML), particularly deep learning has demonstrated strong capabilities in modeling such highly nonlinear and intricate systems. However, two critical challenges limit the deployment of deep learning-based digital twins: Uncertainty Quantification (UQ) and data drift. UQ is vital for ensuring trustworthy predictions, especially in decision-support scenarios. Additionally, data-driven models are often sensitive to changes in the underlying data distribution, such as shot-to-shot variations in fusion experiments, which can lead to performance degradation over time. To address these challenges, we are developing an uncertainty-aware, adaptive digital twin framework. Our approach incorporates deep learning models enhanced with Gaussian Process approximations for predictive uncertainty estimation, coupled with an online learning mechanism that enables continuous model adaptation to new experimental data. This adaptive capability allows the data driven models to respond effectively to evolving plasma behaviors and equipment conditions. Specifically, to mitigate the effects of shot-to-shot drift, our system updates itself incrementally as new data becomes available, improving both robustness and fidelity. Our vision is to evolve this data driven model into a self-sustaining digital twin system that leverages UQ based feedback to continuously refine itself and potentially support real-time decision making. This presentation will cover a brief background on uncertainty quantification for ML, our ongoing effort on development of UQ capabilities for ML, our data science pipeline from data collection to model development and analysis and online learning framework for modeling coil deflection at DIII-D. I will also briefly touch upon opportunities and challenges in development of digital twin framework.

Sammuli, Brian [General Atomics]↗

Large-scale scenarios of electric vehicle charging with a data-driven model of control

Transportation electrification is forecast to bring millions of new electric vehicles to roads worldwide this decade. Planning to support those vehicles depends on detailed scenarios of their electricity demand in both uncontrolled and controlled or smart charging scenarios. In this work, we present a novel modeling approach to enable rapid generation of demand estimates that represent the impact of controlled charging for large-scale scenarios with millions of individual drivers. To model the effect of load modulation control on aggregate charging profiles, we propose a novel machine learning approach that replaces traditional optimization approaches. We demonstrate its performance modeling workplace charging control under a range of electricity rate schedules, achieving small errors (2.5%–4.5%) while accelerating computations by more than 4000 times. To generate the uncontrolled charging demand for scenarios with residential, workplace, and public charging we use statistical representations of a large data set of real charging sessions. We demonstrate the methodology by generating diverse sets of scenarios for California's charging demand in 2030 which consider multiple charging segments and controls, each run locally in under 50 s. We further demonstrate support for rate design by modeling the large-scale impact of a new, custom rate schedule for workplace charging.

33 ADVANCED PROPULSION SYSTEMS↗

The Evaluation of Machine Learning Techniques for Isotope Identification Contextualized by Training and Testing Spectral Similarity

Precise gamma-ray spectral analysis is crucial in high-stakes applications, such as nuclear security. Research efforts toward implementing machine learning (ML) approaches for accurate analysis are limited by the resemblance of the training data to the testing scenarios. The underlying spectral shape of synthetic data may not perfectly reflect measured configurations, and measurement campaigns may be limited by resource constraints. Consequently, ML algorithms for isotope identification must maintain accurate classification performance under domain shifts between the training and testing data. To this end, four different classifiers (Ridge, Random Forest, Extreme Gradient Boosting, and Multilayer Perceptron) were trained on the same dataset and evaluated on twelve other datasets with varying standoff distances, shielding, and background configurations. A tailored statistical approach was introduced to quantify the similarity between the training and testing configurations, which was then related to the predictive performance. Wilcoxon signed-rank tests revealed that the OVR-wrapped XGB significantly outperformed the other algorithms, with confidence levels of 99.0% or above for the 133Ba, 60Co, 137Cs, and 152Eu sources. The findings from this work are significant as they outline techniques to promote the development of robust ML-based approaches for isotope identification.

domain adaptation↗

Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Nuclear Data: What, Why How, Who? [Slides]

Nuclear data is data that describes physics in forms and formats that computer code can read to perform simulations of nuclear processes. The data is put into ”evaluations” following the combination of experiment and theory. Various physics are applied to these evaluations by the NJOY nuclear data processing code to produce application files, which simulation codes (e.g., MCNP, Partisn, etc.) can use to model various scenarios. The Nuclear Data Team at Los Alamos National Laboratory—in partnership with a variety of national and international organizations—provides nuclear data for use at LANL and throughout the world. This data is verified and validated to ensure that it performs as expected and accurately represents Mother Nature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kernelized approaches to streaming compression of scientific data

In this paper three algorithms are developed for the streaming compression of scientific data. The algorithms presented are reliant on the theory of vector-valued reproducing kernel Hilbert spaces and operator valued kernel. Further, the scientific data is modeled as a snapshot of time dependent vector field F(x, t) over a manifold M and the recovery of the data is framed as a learning problem. These processes are then appropriately modified and ana lyzed for the streaming scenario in which data is generated without the ability to revisit past entries.

97 MATHEMATICS AND COMPUTING↗

A Risk-Informed Approach to Trustworthiness Assessment in Digital Twins-Based Autonomous Control

In autonomous control systems, digital twins (DTs) are used to perform diagnostic and prognostic functions. The trustworthiness of these DTs is dependent on quality and coverage of the training data, model accuracy and integrity of sensor data. This work introduces a methodology to determine the trustworthiness of a DT system given faulty sensor data using a risk informed approach. Bayesian Belief Networks (BBNs) are used to propagate uncertainties and determine the probability of trustable recommendations. The decision to trust the control action provided by the DT is based on the DT output, expert opinion, and severity of problems. The performance of DTs is reliant on the data they are trained on. When they encounter out of distribution data, the trustworthiness of the recommendations decreases. To address this issue, we include an expert component that provides input on sensor degradation. For this, we utilize a generative artificial intelligence (AI) model, such as Generative Pretrained Transformer (GPT). The GPT functions as an expert with broad knowledge. The GPT is fine-tuned to understand and discriminate sensor degradation scenarios using manufactured data. This methodology is demonstrated through a case study on a Nearly Autonomous Management and Control System (NAMAC) during a steady state scenario. Various sensor degradation types with different severity levels are considered. Degraded sensor data is processed by the DT system and the fine-tuned GPT. Finally, using the BBN, we combine the GPT information and the DT output with its sources of uncertainty. This provides an output regarding the trustworthiness of the DT recommendation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Agricultural residue production by county - mature-market medium scenario

This dataset contains data on agricultural residue production by county from 2022 to 2041. The agricultural residue includes barley straw, corn stover, oats straw, sorghum stubble, and wheat straw. The dataset was obtained from the database of the BT23 (Davis et al., 2024) for the mature-market medium scenario with biomass market prices from $50 to $130 per dry ton. For access to this dataset, please use the contact form and indicate the dataset by name.

agricultural residues↗

Automated Controller Hardware-In-The-Loop Testbed for EV Charger Resilience Analysis

This paper focuses on the development of a tool that includes an automated testbed with controls, protection, and communications integrated into a real-time system to provide a platform to generate data sets for failure modes and effects analysis. This tool establishes a value for automation of data generation for different scenarios and addresses the gap of nonexistent field data for different applications and use cases. The features of this tool can further be expanded to include multiple power electronics models, communication protocols, and scaled system architectures. This general framework was evaluated for a DC fast charger system use case to provide quantitative solution for resiliency.

Starke, Michael↗

Agricultural crop production by county - mature-market medium scenario

This dataset contains data on agricultural crop production by county from 2022 to 2041. The agricultural crop in this dataset includes barley, biomass sorghum, corn, cotton, energy cane, eucalyptus, grain sorghum, hay, miscanthus, oats, pine, poplar, rice, soybean, switchgrass, wheat, and willow. The dataset was obtained from the database of the BT23 (Davis et al., 2024) for the mature-market medium scenario with biomass market prices from $30 to $130 per dry ton.

agricultural crop↗

Validating Connected, Automated, and Electric Vehicle Models and Simulation - Research Performance Progress Report

The objective of this project is to test connected and automated vehicles with both electrified and internal combustion engine powertrains to support updates and validation of modeling and simulation tools. This includes the development of the components and network architecture to execute and collect empirical data for multiple scenarios and traffic interactions. Specific program objectives include: • Translate Lab algorithms into vehicle and infrastructure controls • Conduct physical testing at realistic scale • Evaluate system performance • Improve models using empirical data • Improve control algorithms from lessons learned • Identify system and algorithm assumptions which need refinement It is important to note that the objective of this project was not to demonstrate the efficacy of the selected algorithms to improve energy efficiency but rather to validate and improve modeling and simulation tools using empirical data. While it is a desirable outcome to concurrently demonstrate improved energy efficiency through use of these algorithms, and in most cases that was the outcome, the success of this project was not predicated on the performance of the algorithm towards improving energy efficiency across all scenarios and test matrices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Agricultural crop and residue production by county - near-term scenario

This dataset contains data on agricultural crop and residue production by county in 2030. The agricultural crops in this dataset include barley, corn, cotton, grain sorghum, hay, oats, rice, soybeans, and wheat. The agricultural residues include barley straw, corn stover, oats straw, sorghum stubble, and wheat straw. The dataset was obtained from the database of the BT23 (Davis et al.,2024) for the near-term scenario with biomass market prices of up to $70 per dry ton.

agricultural crop↗

IM3 + EPRI Data Center Load Projections

This dataset contains scenarios of hourly total electricity demand with and without projected loads from data centers over the period 2022-2040. The root projections without data center demands are identical to those documented in Burleyson et al. 2024. In short, those projections encompass hourly electricity demands for 54 Balancing Authorities (BAs) in the United States across a range of eight of weather and socioeconomic scenarios. Refer to the root dataset and accompanying publication, Burleyson et al. 2025, for information about how those projections were generated. For this derivative dataset we used the base loads from the following scenarios: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The root load projections did not reflect the drastic expansion of data centers that has occurred in the last several years to support artificial intelligence and cloud computing. To reflect growth in data center demand, a second set of load projections were created in which we layered in additional data center load projections based on the data center load growth scenarios described in a 2024 report by the Electric Power Research Institute (EPRI): "Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption". The EPRI projections from the report are included in this dataset (EPRI_2024_Projections.xlsx). That report contained annual state-level data center load projections for four year-over-year growth rates for data center demands: Low (3.71% annual growth) Moderate (5% annual growth) High (10% annual growth) Higher (15% annual growth) To homogenize the load projections with and without data centers we had to get them to a common scale. The first step was to take the EPRI annual state-level data center energy consumption values and convert them to 8760-hr loads for each year. We did that by assuming a flat (e.g., not weather- or time-sensitive) load profile and distributing the data center loads in each state evenly across all hours in a year. From there the loads were downscaled from the state-level to the county-level using 2019 county-level populations as weights. Finally, the county-level hourly data center loads were summed to the BA-level using the county-to-BA mapping underpinning the root load projections. The net result is 16 (4 weather and socioeconomic scenarios crossed with 4 data center load growth scenarios) unique load projections for the period 2022-2040. The file format follows that of the root dataset with a single additional column "Scaled_TELL_BA_Load_with_DC_MWh" that contains the hourly loads with the added data center loads for a given BA-year-scenario combination. Please refer to the readme file in the root dataset for more information on the file format.

Burleyson, Casey [Pacific Northwest National Labor↗