Dissolved Oxygen Sensor System for Real-time, In-situ Subsurface Monitoring: Geospatial Mapping of DOE Field Sites, Phase I Final Report
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Spatial resolution represents akey performance aspect in electrical capacitance volume tomography (ECVT). Factors affecting the resolution include the ``soft-field'' nature of ECVT, the number of capacitance channels used, the ill-conditioned nature of the imaging reconstruction problem, and the signal-to-noise ratio of the measurement apparatus. In this study, the effect of choosing different numbers of capacitance plates on the performance of ECVT is investigated. Specifically, two ECVT sensors with 12 and 24 capacitance channels but covering equal volumes of a cylinder are used to examine the resulting impact on the image resolution.
Explore the source record for details and available documents.
The U.S. Department of Energy (DOE) has ownership and operational responsibility for a large enterprise of nuclear facilities that provide essential functions to DOE missions ranging from national security to discovery science and energy research. These facilities support a number of DOE programs and offices including the National Nuclear Security Administration, Office of Science, and Office of Environmental Management. With many unique and “one of a kind” functions, these facilities represent a tremendous national investment, and assuring their safety and integrity is fundamental to the success of a breadth of DOE programs. Many DOE critical facilities are located in regions with significant natural phenomenon hazards including major earthquakes and DOE has been a leader in developing standards for the seismic analysis of nuclear facilities. Attaining and sustaining excellence in nuclear facility design and management must be a core competency of the DOE. An important part of nuclear facility management is the ability to monitor facilities and rapidly assess the response and integrity of the facilities after any major upset event. Experience in the western U.S. has shown that understanding facility integrity after a major earthquake is a significant challenge which, lacking key data, can require extensive effort and significant time. In the work described in the attached report, a transformational approach to earthquake monitoring of facilities is described and demonstrated. An entirely new type of optically-based sensor that can directly and accurately measure the earthquake-induced deformations of a critical facility has been developed and tested. This report summarizes large-scale shake table testing of the sensor concept on a representative steel frame building structure, and provides quantitative data on the accuracy of the sensor measurements.
Not Available
Not Available
Not provided.
Not Available
A paper presenting the design and testing results of a computational radiation sens
Not provided.
Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.
The architecture of an LLNL airborne imaging and detection system is considered in this report. The purpose of the system is to find the location of substances of interest by detecting their chemical signatures using a long-wave infrared (LWIR) imager with geo-registration capability. The detection system consists of an LWIR imaging spectrometer as well as a network of computer hardware and analysis software for analyzing the images for the features of interest. The system has been in the operations phase now for well over a year, and as such, there is enough use data and feedback from the primary beneficiary to assess the current successes and shortcomings of the LWIR system architecture. LWIR system has been successful in providing reliable data collection and the delivery of a report with results. The weakness of the architecture has been identified in two areas: with the network of computer hardware and software and with the feedback of the state of the system health. Regarding the former, the system computers and software that carry out the data acquisition are too complicated for routine operations and maintenance. With respect to the latter, the primary beneficiary of the instrument’s data does not have enough metrics to use to filter the large quantity of data to determine its utility. In addition to the needs in these two areas, a latent need of one of the stakeholders is identified. This report documents the strengths and weaknesses, as well as proposes a solution for enhancing the architecture that simultaneously addresses the two areas of weakness and leverages them to meet the newly identified latent need.
No abstract provided.
Explore the source record for details and available documents.
Power grid resilience and reliability is crucial to supporting critical infrastructure. Service interruptions can have devastating consequences to communication, emergency, and transportation services, just to name a few. In addition to infrastructure, power services are crucial to everyday life. Nearly every element of modern-day living relies on a stable and functioning power grid - heating and cooling systems to lighting, refrigeration, telecommunications, and internet access. Interruptions in the power supply can range from minor inconveniences, such as the temporary loss of internet or television services, to more significant problems, like the inability to access medical equipment or emergency services during critical situations. As climate conditions worsen, the reliability of the power grid becomes even more significant. Extreme weather events, such as hurricanes, wildfires, or severe storms, can cause serious damage to power infrastructure, leading to prolonged power outages. Rising temperatures and changing weather patterns can strain the grid, resulting in increased demand for electricity, stressing transmission and distribution systems.
A prototype has been developed at Sandia National Laboratories to collect nominally sensitive data from a mock treaty accountable item, record that information as non-sensitive encrypted outputs, and allow inspectors to subsequently evaluate that information at a time and location of their choice without any risk of the host party’s data being inadvertently (or maliciously) revealed.
Abstract not provided.
Prompted by the unexpected failure of piezoresistive sensors in both an elevated gamma-ray environment and reactor core pulse tests, we initiated radiation testing of several MEMS piezoresistive accelerometers and pressure transducers to ascertain their radiation hardness. Some commercial off-the-shelf sensors are found to be viable options for use in a high-energy pulsed reactor, but others suffer severe degradation and even catastrophic failure. Although researchers are promoting the use of MEMS devices in radiation-harsh environment, we nevertheless find assurance testing necessary.