Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Three-Axis Fixed-Simulator Investigation of the Effects on Control Precision of Various Ways of Utilizing Rate Signals

A three-axis vehicle control study has been made by use of a fixed simulator and analog computing equipment, to evaluate the effects of various ways of utilizing rate information. A side-arm controller providing proportional acceleration control was used with a simulated vehicle having no inherent stability or damping. Vehicle rate signals were used to provide control feedback or system damping and were used in the instrument display either separate from or summed with displacement signals. Near optimum performance of both transitions in roll and control of system disturbance was obtained by using a combination of system damping and summed displacement signals and rate signals.

McKee, John W.↗

The Generation-X X-ray Observatory Vision Mission and Technology Study

The new frontier in astrophysics is the study of the birth and evolution of the first stars, galaxies and black holes in the early Universe. X-ray astronomy opens a window into these objects by studying the emission from black holes, supernova explosions and the gamma-ray burst afterglows of massive stars. However, such objects are beyond the grasp of current or near-future observatories. X-ray imaging and spectroscopy of such distant objects will require an X-ray telescope with large collecting area and high angular resolution. Our team has conceived the Generation-X Vision Mission based on an X-ray observatory with 100 sq m collecting area at 1 keV (1000 times larger than Chandra) and 0.1 arcsecond angular resolution (several times better than Chandra and 50 times better than the Constellation-X resolution goal). Such an observatory would be capable of detecting the earliest black holes and galaxies in the Universe, and will also study extremes of density, gravity, magnetic fields, and kinetic energy which cannot be created in laboratories. NASA has selected the Generation-X mission for study under its Vision Mission Program. We describe the studies being performed to develop the mission concept and define candidate technologies and performance requirements for Generation-X. The baseline Generation-X mission involves four 8m diameter X-ray telescopes operating at Sun-Earth L2. We trade against an alternate concept of a single 26m diameter telescope with focal plane instruments on a separate spacecraft. A telescope of this size will require either robotic or human-assisted in-flight assembly. The required effective area implies that extremely lightweight grazing incidence X-ray optics must be developed. To achieve the required aerial density of at least 100 times lower than in Chandra, we will study 0.1mm thick mirrors which have active on-orbit figure control. We discuss the suite of required detectors, including a large FOV high angular resolution imager, a cryogenic imaging spectrometer and a grating spectrometer. We outline the development roadmap to confront the many technological challenges far implementing the Generation-X mission.

Figueroa-Feliciano, Enectali↗

Mission Study for Generation-X: A Large Area and High Angular Observatory to Study the Early Universe

In this report we provide a summary of the technical progress achieved during the last year Generation-X Vision Mission Study. In addition, we provide a brief programmatic status. The Generation-X (Gen-X) Vision Mission Study investigates the science requirements, mission concepts and technology drivers for an X-ray telescope designed to study the new frontier of astrophysics: the birth and evolution of the first stars, galaxies and black holes in the early Universe. X-ray astronomy offers an opportunity to detect these via the activity of the black holes, and the supernova explosions and gamma-ray burst afterglows of the massive stars. However, such objects are beyond the grasp of current missions which are operating or even under development. Our team has conceived a Gen-X Vision Mission based on an X-ray observatory with 100 m2 collecting area at 1 keV (1000 times larger than Chandra) and 0.1 arcsecond angular resolution (several times better than Chandra and 50 times better than the Constellation-X resolution goal). Such a high energy observatory will be capable of detecting the earliest black holes and galaxies in the Universe, and will also study extremes of density, gravity, magnetic fields, and kinetic energy which cannot be created in laboratories. In our study we develop the mission concept and define candidate technologies and performance requirements for Gen-X. The baseline Gen-X mission involves four 8 m diameter X-ray telescopes operating at Sun-Earth L2. We trade against an alternate concept of a single 26 m diameter telescope with focal plane instruments on a separate spacecraft. A telescope of this size will require either robotic or human-assisted in-flight assembly. The required effective area implies that extremely lightweight grazing incidence X-ray optics must be developed. To achieve the required areal density of at least 100 times lower than for Chandra, we study 0.2 mm thick mirrors which have active on-orbit figure control. We also study the suite of required detectors, including a large FOV high angular resolution imager, a cryogenic imaging spectrometer and a reflection grating spectrometer.

Brissenden, Roger↗

Observations of the Ion Signatures of Double Merging and the Formation of Newly Closed Field Lines

Observations from the Polar spacecraft, taken during a period of northward interplanetary magnetic field (IMF) show magnetosheath ions within the magnetosphere with velocity distributions resulting from multiple merging sites along the same field line. The observations from the TIDE instrument show two separate ion energy-time dispersions that are attributed to two widely separated (-20Re) merging sites. Estimates of the initial merging times show that they occurred nearly simultaneously (within 5 minutes.) Along with these populations, cold, ionospheric ions were observed counterstreaming along the field lines. The presence of such ions is evidence that these field lines are connected to the ionosphere on both ends. These results are consistent with the hypothesis that double merging can produce closed field lines populated by solar wind plasma. While the merging sites cannot be unambiguously located, the observations and analyses favor one site poleward of the northern cusp and a second site at low latitudes.

Chandler, Michael O.↗

Sample Acquisition and Analytical Chemistry Challenges to Verifying Compliance to Aviators Breathing Oxygen (ABO) Purity Specification

NASA has been developing and testing two different types of oxygen separation systems. One type of oxygen separation system uses pressure swing technology, the other type uses a solid electrolyte electrochemical oxygen separation cell. Both development systems have been subjected to long term testing, and performance testing under a variety of environmental and operational conditions. Testing these two systems revealed that measuring the product purity of oxygen, and determining if an oxygen separation device meets Aviator's Breathing Oxygen (ABO) specifications is a subtle and sometimes difficult analytical chemistry job. Verifying product purity of cryogenically produced oxygen presents a different set of analytical chemistry challenges. This presentation will describe some of the sample acquisition and analytical chemistry challenges presented by verifying oxygen produced by an oxygen separator - and verifying oxygen produced by cryogenic separation processes. The primary contaminant that causes gas samples to fail to meet ABO requirements is water. The maximum amount of water vapor allowed is 7 ppmv. The principal challenge of verifying oxygen produced by an oxygen separator is that it is produced relatively slowly, and at comparatively low temperatures. A short term failure that occurs for just a few minutes in the course of a 1 week run could cause an entire tank to be rejected. Continuous monitoring of oxygen purity and water vapor could identify problems as soon as they occur. Long term oxygen separator tests were instrumented with an oxygen analyzer and with an hygrometer: a GE Moisture Monitor Series 35. This hygrometer uses an aluminum oxide sensor. The user's manual does not report this, but long term exposure to pure oxygen causes the aluminum oxide sensor head to bias dry. Oxygen product that exceeded the 7 ppm specification was improperly accepted, because the sensor had biased. The bias is permanent - exposure to air does not cause the sensor to return to its original response - but the bias can be accounted for by recalibrating the sensor. After this issue was found, continuous measurements of water vapor in the oxygen product were made using an FTIR. The FTIR cell is relatively large, so response time is slow - but moisture measurements were repeatable and accurate. Verifying ABO compliance for oxygen produced by commercial cryogenic processes has a different set of sample acquisition and analytical chemistry challenges. Customers want analytical chemists to conserve as much as possible. Hygrometers are not exposed to hours of continuous flow of oxygen, so they don't bias, but small amounts of contamination in valves can cause a "fail". K bottles are periodically cleaned and recertified - after cleaning residual moisture can cause a "fail". Operators let bottle pressure drop to room pressure, introduce outside air into the bottle, and the subsequent fill will "fail". Outside storage of K‐bottles has allowed enough in‐leakage, so contents will "fail".

Graf, John↗

Experimental Estimation of CLASP Spatial Resolution: Results of the Instrument's Optical Alignment

The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a sounding-rocket experiment currently being built at the National Astronomical Observatory of Japan. This instrument aims to probe for the first time the magnetic field strength and orientation in the solar upper-chromosphere and lower-transition region. CLASP will measure the polarization of the Lyman-Alpha line (121.6nm) with an unprecedented accuracy, and derive the magnetic field information through the Hanle effect. Although polarization accuracy and spectral resolution are crucial for the Hanle effect detection, spatial resolution is also important to get reliable context image via the slit-jaw camera. As spatial resolution is directly related with the alignment of optics, it is also a good way of ensuring the alignment of the instrument to meet the scientific requirement. This poster will detail the experiments carried out to align CLASP's optics (telescope and spectrograph), as both part of the instrument were aligned separately. The telescope was aligned in double-pass mode, and a laser interferometer (He-Ne) was used to measure the telescope's wavefront error (WFE). The secondary mirror tilt and position were adjusted to remove comas and defocus aberrations from the WFE. Effect of gravity on the WFE measurement was estimated and the final WFE derived in zero-g condition for CLASP telescope will be presented. In addition, an estimation of the spot shape and size derived from the final WFE will also be shown. The spectrograph was aligned with a custom procedure: because Ly-light is absorbed by air, the spectrograph's off-axis parabolic mirrors were aligned in Visible Light (VL) using a custom-made VL grating instead of the flight Ly- grating. Results of the alignment in Visible Light will be shown and the spot shape recorded with CCDs at various position along the slit will be displayed. Results from both alignment experiment will be compared to the design requirement, and will be combined in order to estimate CLASP spatial resolution after its alignment in visible light.

spatial resolution↗

Laser-Guided Space Interferometer

The mirrors of astronomical interferometers need to be aligned within a fraction of a wavelength relative to one another. This would be especially challenging for optical instruments with mirrors separated by hundreds of meters flying in Earth’s orbit. However, in this work, we show that this alignment can be achieved by means of: (i) flying the mirror cluster in a particular orbital configuration; (ii) closing a coarse positioning loop using GNSS (Global Navigation Satellite System); and (iii) closing a fine wavefront-control loop using light from a laser guide star. The orbital configuration is designed to keep the mirrors passively pointing at the target star (up to a small orbital perturbation) while the interferometer cluster is orbiting and changing its baseline. The laser guide star would be flying in the same orbit but in the opposite direction. In medium- or high-Earth orbit, the interferometer would be able to observe a star for several hours per orbit. In this work, we analyzed the performance of an optical space interferometer consisting of nine 20 cm mirrors mounted on CubeSats and flying 3 km apart (together with a combiner and a laser guide star small satellite). This configuration supports a resolution of 0.04 milliarcseconds - an order of magnitude better than current ground-based interferometers. We estimate the performance of this system imaging stellar surfaces assuming perfect wavefront estimation and control.

Leonid Pogorelyuk↗

AIR Instrument Array

The large number of radiation types composing the atmospheric radiation requires a complicated combination of instrument types to fully characterize the environment. A completely satisfactory combination has not as yet been flown and would require a large capital outlay to develop. In that the funds of the current project were limited to essential integration costs, an international collaboration was formed with partners from six countries and fourteen different institutions with their own financial support for their participation. Instruments were chosen to cover sensitivity to all radiation types with enough differential sensitivity to separate individual components. Some instruments were chosen as important to specify the physical field component and other instruments were chosen on the basis that they could be useful in dosimetric evaluation. In the present paper we will discuss the final experimental flight package for the ER-2 flight campaign.

Jones, I. W.↗

Long-Lived Linear-Motion Suspension For Cryogenic Instrument

Mechanism suspends optical component in cryogenic instrument in such way to allow component to translate smoothly along one axis, without vibration. Bearings located outside cooled instrument chamber for longer life. Thermal isolators separate bearings from cryogenic environment inside instrument chamber.

Packard, Douglas T.↗

Ulysses plasma observations in the Jovian magnetosheath

The solar wind plasma experiment aboard the Ulysses spacecraft, including separate ion and electron instruments, measured the plasma properties of the Jovian magnetosheath during the February 1992 encounter with Jupiter. Seven separate magnetosheath intervals were observed, as well as four bow shock crossings and numerous encounters with the magnetopause and its boundary layer. We present an overview of ion and electron bulk parameters and a sampling of distribution shapes for the magnetosheath and adjacent plasma regions. Plasma flows are generally appropriate for slowing and deflection of the solar wind flow about a relatively stationary obstacle, with the notable exception of the first inbound sheath transit, when an expanding magnetosphere resulted in sunward flow just above the magnetopause. The existence of a planetary depletion layer is suggested by trends in plasma density for some magnetopause encounters. The magnetopause boundary layer is characterized by a combination of sheathlike and magnetospheric distributions of both ions and electrons. The ion population in the sheath is observed to include a significant population of suprathermal protons. Electron distributions have a distinctive shape previously observed in the terrestrial magnetosheath, with fluxes parallel to the magnetic field dominating at thermal energies and perpendicular fluxes dominating at higher energies. Trends in electron temperature near the bow shock indicate that shock motion plays an important role in heating the electrons. In general, the plasma characteristics of the Jovian magnetosheath are quite similar to those in its terrestrial counterpart, but the compressible nature of the Jovian magnetosphere accentuates the importance of boundary motions.

Phillips, J. L.↗

Ulysses Plasma Observations in the Jovian Magnetosheath

The solar wind plasma experiment aboard the Ulysses spacecraft, including separate ion and electron instruments, measured the plasma properties of the Jovian magnetosheath during the February 1992 encounter with Jupiter. Seven separate magnetosheath intervals were observed, as well as four bow shock crossings and numerous encounters with the magnetopause and its boundary layer.

Ulysses↗

Stratified Radiometric Means for the Evaluation of AIRS and CrIS

There are now five hyperspectral infrared sounders in orbit (AIRS, two CrIS instruments, two IASI instruments). A longterm record spanning these instruments and continuing forward with future instruments holds great promise for the study of weather and climate. This long-term record must separate the effects of instrument artifacts and weather variability. We introduce the “StratRad” stratified radiance means product, containing means of groups of spectra for AIRS on Aqua and CrIS on SNPP. We show how this product can be used both to illuminate instrument artifacts and to study common observations of weather patterns at an accuracy of better than 0.1 K. Radiances are stratified by latitude, longitude, day/night, land/sea, and observation angle.

Kahn, Brian H.↗

Voyager observations of O(+6) and other minor ions in the solar wind

The plasma science (PLS) experiments on the Voyager 1 and 2 spacecraft began making measurements of the solar wind shortly after the two launches in the fall of 1977. In reviewing the data obtained prior to the Jupiter encounters in 1979, we have found that the large dynamic range of the PLS instrument generally allows a clean separation of signatures of minor ions (about 2.5% of the time) during a single instrument scan in energy per charge. The minor ions, most notably O(+6), are well separated from the protons and alpha particles during times when the solar wind Mach number (ratio of streaming speed to thermal speed) is greater than approximately 15. During the Earth to Jupiter cruise we find that the average ratio of alpha particle number density to that of oxygen is 66 +/- 7 (Voyager 1) and 71 +/- 17 (Voyager 2). These values are consistent with the value 75 +/- 20 inferred from the Ion Composition Instrument on ISEE 3 during the period spanning 1978 and 1982. We have inferred an average coronal temperature of (1.7 +/- 0.1) x 10(exp 6) K based on the ratio of O(+7) to O(+6) number densities. Our observations cover a period of increasing solar activity. During this time we have found that the alpha particle to proton number density ratio is increasing with the solar cycle, the oxygen to proton ratio increases, and the alpha particle to oxygen ratio remains relatively constant in time.

Villanueva, Louis↗

Integrating a Microwave Radiometer into Radar Hardware for Simultaneous Data Collection Between the Instruments

The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This unintuitive step allows the digital receiver to sample both the radiometer and radar data at a rapid, synchronized data rate (greater than 1 MHz bandwidth). Once both signals are sampled by the same digital receiver, high-speed quality control can be performed on the radiometer data to allow it to take data simultaneously with the radar. The radiometer data can be blanked during radar transmit, or when the radar return is of a power level high enough to corrupt the radiometer data. Additionally, the receiver protection switches in the RF front end can double as radiometer calibration sources, the short (four-microsecond level) switching periods integrated over many seconds to estimate the radiometer offset. The major benefit of this innovation is that there is minimal impact on the radar performance due to the integration of the radiometer, and the radiometer performance is similarly minimally affected by the radar. As the radar and radiometer are able to operate simultaneously, there is no extended period of integration time loss for the radiometer (maximizing sensitivity), and the radar is able to maintain its full number of pulses (increasing sensitivity and decreasing measurement uncertainty).

McLinden, Matthew↗

Advances in Above- and In-Water Radiometry, Volume 3: Hybridspectral Next-Generation Optical Instruments

This publication documents the scientific advances associated with new instrument systems and accessories built to improve above- and in-water observations of the apparent optical properties (AOPs) for a diversity of water masses, including optically complex waters. The principal objective is to be prepared for the launch of next-generation ocean color satellites with the most capable commercial off-the-shelf (COTS) instrumentation in the shortest time possible. The technologies described herein are entirely new hybrid sampling capabilities, so as to satisfy the requirements established for next-generation missions. Both above- and in-water instruments are documented with software options for autonomous control of data collection activities as applicable. The instruments were developed for the Hybridspectral Alternative for Remote Profiling of Optical Observations for NASA Satellites (HARPOONS) vicarious calibration project. The state-of-the-art accuracy required for vicarious calibration also led to the development of laboratory instruments to ensure the field observations were within uncertainty requirements. Separate detailed presentations of the individual instruments provide the hardware designs, accompanying software for data acquisition and processing, and examples of the results achieved.

Hooker, Stanford B.↗

Balloon borne in-situ detection of OH in the stratosphere from 37 to 23 km

The OH number density in the stratosphere has been measured over the altitude interval of 37 to 23 km at midday via a balloon-borne gondola launched from Palestine, Texas on July 6, 1988. OH radicals are detected with a laser-induced fluorescence instrument employing a 17-kHz-repetition-rate copper vapor laser-pumped dye laser optically coupled to an enclosed flow, in-situ sampling chamber. OH abundances ranged from 88 + or - 3l pptv in the 36 to 35 km interval to 0.9 + or - 0.8 pptv in the 24 to 23 km interval. The stated uncertainty includes that from both measurement precision and accuracy. Simultaneous detection of ozone and water vapor densities was carried out with separate on-board instruments.

Stimpfle, R. M.↗

Test of the Equivalence Principle in an Einstein Elevator

The scientific goal of the experiment is to test the equality of gravitational and inertial mass (i.e., to test the Principle of Equivalence) by measuring the independence of the rate of fall of bodies from their compositions. The measurement is accomplished by measuring the relative displacement (or equivalently acceleration) of two falling bodies of different materials which are the proof masses of a differential accelerometer spinning about an horizontal axis to modulate a possible violation signal. A non-zero differential acceleration appearing at the signal frequency will indicate a violation of the Equivalence Principle. The goal of the experiment is to measure the Eotvos ratio og/g (differential acceleration/common acceleration) with a targeted accuracy that is about two orders of magnitude better than the state of the art (presently at several parts in 10(exp 13). The analyses carried out during this first grant year have focused on: (1) evaluation of possible shapes for the proof masses to meet the requirements on the higher-order mass moment disturbances generated by the falling capsule; (2) dynamics of the instrument package and differential acceleration measurement in the presence of errors and imperfections; (3) computation of the inertia characteristic of the instrument package that enable a separation of the signal from the dynamics-related noise; (4) a revised thermal analysis of the instrument package in light of the new conceptual design of the cryostat; (5) the development of a dynamic and control model of the capsule attached to the gondola and balloon to define the requirements for the leveling mechanism (6) a conceptual design of the leveling mechanism that keeps the capsule aligned before release from the balloon; and (7) a new conceptual design of the customized cryostat and a preliminary valuation of its cost. The project also involves an international cooperation with the Institute of Space Physics (IFSI) in Rome, Italy. The group at IFSI is in charge of prototyping the differential accelerometer and carrying out precursor laboratory measurements. During this grant year, our partners analyzed and then designed a new prototype of differential accelerometer that has several characteristics in common with the flight accelerometer at this point of the instrument development. The highlights of these activities are documented in a section of this report.

Shapiro, Irwin I.↗