Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Some observations of separated flow on finite wings

Wind tunnel test results for aspects of flow over airfoils exhibiting single and multiple trailing edge stall 'mushroom' cells are reported. Rectangular wings with aspect ratios of 4.0 and 9.0 were tested at Reynolds numbers of 480,000 and 257,000, respectively. Surface flow patterns were visualized by means of a fluorescent oil flow technique, separated flow was observed with a tuft wand and a water probe, spanwise flow was studied with hot-wire anemometry, smoke flow and an Ar laser illuminated the centerplane flow, and photographs were made of the oil flow patterns. Swirl patterns on partially and fully stalled wings suggested vortex flow attachments in those regions, and a saddle point on the fully stalled AR=4.0 wing indicated a secondary vortex flow at the forward region of the separation bubble. The separation wake decayed downstream, while the tip vortex interacted with the separation bubble on the fully stalled wing. Three mushroom cells were observed on the AR=9.0 wing.

Winkelmann, A. E.↗

Using a Chromatographic Pseudophase Model To Elucidate the Mechanism of Olefin Separation by Silver(I) Ions in Ionic Liquids

Silver(I) ions undergo selective olefin complexation and have been utilized in various olefin/paraffin separation techniques such as argentation chromatography and facilitated transport membranes. Ionic liquids (ILs) are solvents known for their low vapor pressure, high thermal stability, low melting points, and ability to promote a favorable solvation environment for silver(I) ion–olefin interactions. To develop highly selective separation systems, a fundamental understanding of analyte partitioning to the stationary phase and the thermodynamic driving forces behind solvation is required. In this study, a chromatographic model treating silver(I) ions as a pseudophase is constructed and employed for the first time to investigate the olefin separation mechanism in silver(I) salt/IL mixtures. Stationary phases containing varying amounts of noncoordinated silver(I) salt ([Ag + ][NTf 2 – ]) dissolved in the 1-decyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 10 MIM + ][NTf 2 – ]) IL are utilized to determine the partition coefficients of various analytes including alkanes, alkenes, alkynes, aromatics, aldehyde, esters, and ketones. As ligand coordination to silver(I) ions is known to lower its olefin complexation capability, this study also examines two different types of coordinated silver(I) ion pseudophases, namely, monocoordinated silver(I) salt ([Ag + (1-decyl-2-methylimidazole, DMIM)][NTf 2 – ]) and dicoordinated silver(I) salt ([Ag + (1-methylimidazole, MIM)(DMIM)][NTf 2 – ]). The extent of olefin partitioning to the coordinated silver(I) ion pseudophases over the carrier gas and IL decreased by up to two orders of magnitude. Values for enthalpy, entropy, and free energy of solvation were determined for the three silver(I) ion-containing systems. Olefin retention was observed to be enthalpically dominated, while ligand coordination to the silver(I) ion pseudophase resulted in variations for both enthalpic and entropic contributions to the free energy of solvation. Furthermore, the developed model can be used to study chemical changes that occur in silver(I) ions over time as well as identify optimal silver(I) salt/IL mixtures that yield high olefin selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing the Drop-Size Distribution-Based Separation of Stratiform and Convective Rain Using Radar and Disdrometer Data from a Mid-Latitude Coastal Region

Stratiform and convective rain are associated with different microphysical processes and generally produce drop-size distributions (DSDs) with different characteristics. Previous studies using data from (a) a tropical coastal location, (b) a mid-latitude continental location with semi-arid climate, and (c) a sub-tropical continental location, found that the two rain types could be separated in the NW–Dm space, where Dm is the mass-weighted mean diameter and NW is the normalized intercept parameter. In this paper, we investigate the same separation technique using data and observations from a mid-latitude coastal region. Three-minute DSDs from disdrometer measurements are used for the NW- versus Dm-based classification and are compared with simultaneous observations from an S-band polarimetric radar 38 km away from the disdrometer site. Specifically, RHI (range-height indicator) scans over the disdrometer were used for confirmation. Results show that there was no need to modify the separation criteria from previous studies. Three-minute DSDs from the same location were used as input to scattering calculations to derive retrieval equations for NW and Dm for the S-band radar using an improved technique and applied to the RHI scans to identify convective and stratiform rain regions. Two events are shown as illustrative examples.

Merhala Thurai↗

Comparing Experimental Results for Large Particle Separation from Non-Newtonian Slurries Using Full and Tapered Bump Arrays

To separate particles from carrier fluids arrays of staggered posts inserted into the flow stream can be employed. The smaller particles follow the flow stream while the larger particles move laterally to one side. During flow, the concentration of particulate increases in one direction and decreases in the other crosswise direction. This technique separates the particles from the carrier fluid. Experiments using a slurry with non-Newtonian rheology were conducted to evaluate large particle separation from the non-Newtonian carrier fluid using bump arrays. The bentonite kaolin clay slurry with non-Newtonian rheology was spiked with large diameter inert glass particles. Experiments with flow through lateral displacement arrays evaluated the performance of particle separation using two array configurations: a full array with all posts and a tapered array with posts removed in a triangular portion of the array past the rows of anticipated particle of separation. The posts are staggered posts to promote particle segregation to one side of the flow channel. Using this type of array for removing particles from non-Newtonian yield stress slurries is novel and we present unique results. In this paper, the performance of full and tapered arrays are compared. These results have many industrial applications including removing particles from slurries of nuclear waste. Large particle removal is an important step in waste processing.

slurry, solids removal, deterministic lateral disp↗

Implementation and evaluation of multi-dual mode counter-current chromatography in the CUP Modeler software

Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Classifying Particles By Acoustic Levitation

Separation technique well suited to material processing. Apparatus with rectangular-cross-section chamber used to measure equilibrium positions of low-density spheres in gravitational field. Vertical acoustic forces generated by two opposing compression drivers exciting fundamental plane-wave mode at 1.2 kHz. Additional horizontal drivers centered samples along vertical axis. Applications in fusion-target separation, biological separation, and manufacturing processes in liquid or gas media.

Barmatz, Martin B.↗

Frequency-Channelized SAR Processing For Multiple Angle Looks

Technique for processing synthetic-aperture-radar (SAR) signals exploits fact that center frequency of frequency channel of data being processed linked directly to squint angle and to azimuth angle. Also exploits fact in multilook SAR data processing, total bandwidth of each SAR polarization channel divided into N (typically, N = 16) equal frequency channels, data in each of which processed separately. Technique has yielded data on directionality of radar back scatter from agricultural fields.

Dubois, Pascale C.↗

Mechanistic Investigation of Co(II) Extraction by TODGA to Aid Nuclear Forensic Separations

Nuclear forensic (NF) analysis supports law enforcement inquiries by analyzing evidence tainted with radioactive substances. Separation techniques can be used to identify and quantify actinides and fission 15 products in post-detonation (PD) debris. Environmental transition metals, also present in PD residues, have been observed to impact critical isotope extractions. For example, radio stable cobalt (Co), ubiquitous in urban environments, particularly in corrosion-resistant alloys, paint-drying agents, dyes, and pigments, can impact the separation of important actinides and fission products. The presented work aims to elucidate the chemistry Q2 governing Co extraction in samples pertinent to PDNF. Chemistry between Co and N,N,N,‘N’-tetraoctyl diglyco- 20 lamide (TODGA), the ligand present in the commercial chromatographic resin diglycolamide (DGA), were studied via solvent and chromatographic extraction and spectroscopic analyses. These results indicate that a tetrahedral Co(II) species is extracted by TODGA from highly acidic (>5M HCl) solutions via a spontaneous entropy-driven reaction. Furthermore, extraction trends in varied acid concentrations are consistent between solvent extraction and chromatographic extraction methods.

activation product↗

Heterogeneity in the growth hormone pituitary gland system of rats and humans: Implications to microgravity based research

The cell separation techniques of velocity sedimentation, flow cytometry and continuous flow electrophoresis were used to obtain enriched populations of growth hormone (GH) cells. The goal was to isolate a GH cell subpopulation which releases GH molecules which are very high in biological activity, it was important to use a method which was effective in processing large numbers of cells over a short time span. The techniques based on sedimentation are limited by cell density overlaps and streaming. While flow cytometry is useful in the analytical mode for objectively establishing cell purity, the numbers of cells which can be processed in the sort mode are so small as to make this approach ineffective in terms of the long term goals. It was shown that continuous flow electrophoresis systems (CFES) can separate GH cells from other cell types on the basis of differences in surface charge. The bioreactive producers appear to be more electrophoretically mobile than the low producers. Current ground based CFES efforts are hampered by cell clumping in low ionic strength buffers and poor cell recoveries from the CFES device.

Hymer, W. C.↗

Complete separation of benzene-cyclohexene-cyclohexane mixtures via temperature-dependent molecular sieving by a flexible chain-like coordination polymer

Abstract The separation and purification of C6 cyclic hydrocarbons (benzene, cyclohexene, cyclohexane) represent a critically important but energy intensive process. Developing adsorptive separation technique to replace thermally driven distillation processes holds great promise to significantly reduce energy consumption. Here we report a flexible one-dimensional coordination polymer as an efficient adsorbent to discriminate ternary C6 cyclic hydrocarbons via an ideal molecular sieving mechanism. The compound undergoes fully reversible structural transformation associated with removal/re-coordination of water molecules and between activated and hydrocarbon-loaded forms. It exhibits distinct temperature- and adsorbate-dependent adsorption behavior which facilitates the complete separation of benzene, cyclohexene and cyclohexane from their binary and ternary mixtures, with the record-high uptake ratios for C 6 H 6 /C 6 H 12 and C 6 H 10 /C 6 H 12 in vapor phase and highest binary and ternary selectivities in liquid phase. In situ infrared spectroscopic analysis and ab initio calculations provide insight into the host-guest interactions and their effect on the preferential adsorption and structural transformation.

36 MATERIALS SCIENCE↗

Tuning the Solvation and Solubility Properties of Molecularly Heterogeneous Nonionic Deep Eutectic Solvents via Interface Organization

Common separation techniques, such as liquid− liquid extraction, are usually used for extractions and purifications due to their industrial scalability and affordability. However, these well-established practices are hindered by low selectivity and challenges in recovering solutes and solvents. Deep eutectic solvents (DES), a fairly new type of solvent, have the potential to overcome these issues. DESs are binary mixtures whose physical properties can be tuned by selecting the appropriate precursors to facilitate and/or enhance processes such as extraction. A promising DES for selective separations is formed when lauric acid (LA) is mixed with N-methylacetamide (NMA). This LA-NMA DES has a heterogeneous microscopic structure that can solvate compounds with completely different polarities. This study explores how forming an organized structure on the mesoscale affects the solubility of nonpolar solutes in nonionic DESs. To this end, the molecular and mesoscale structures and their effect on the solubility and solvation properties are evaluated for the LA-NMA DES and two new DESs with slight chemical variations in their precursors. It is observed that the organization of the nonpolar DES domains and, consequently, of their interfaces directly relates to the solubility of nonpolar compounds. Specifically, correctly selecting the DES precursors that form organized nonpolar domains leads to an organized interface in which the nonpolar solutes are solvated, thereby increasing the solubility. Additionally, enhanced dissolution power was observed in a completely different DES with mesoscale order in its molecular structure and composed of menthol and lauric acid. The latter result further validates the proposed tunability of the DES dissolution power through organized interfaces, extending it beyond a specific DES family and opening the possibility of new extraction-tailored designer solvents.

Extraction↗

Multiple regression technique for Pth degree polynominals with and without linear cross products

A multiple regression technique was developed by which the nonlinear behavior of specified independent variables can be related to a given dependent variable. The polynomial expression can be of Pth degree and can incorporate N independent variables. Two cases are treated such that mathematical models can be studied both with and without linear cross products. The resulting surface fits can be used to summarize trends for a given phenomenon and provide a mathematical relationship for subsequent analysis. To implement this technique, separate computer programs were developed for the case without linear cross products and for the case incorporating such cross products which evaluate the various constants in the model regression equation. In addition, the significance of the estimated regression equation is considered and the standard deviation, the F statistic, the maximum absolute percent error, and the average of the absolute values of the percent of error evaluated. The computer programs and their manner of utilization are described. Sample problems are included to illustrate the use and capability of the technique which show the output formats and typical plots comparing computer results to each set of input data.

Davis, J. W.↗

Advanced Metal Separation (AMS) via Marangoni Effect-driven Separation

For practical, economical, and sustainable human missions to the Moon, processing of lunar regolith and metal oxides is necessary for localized production of oxygen (O2) and metals that can be repurposed as rocket propellant, life support O2, and in-space manufactured parts. The primary candidates for in-situ resource utilization (ISRU) regolith processing are carbothermic reductions and molten regolith electrolysis (MRE) which both produce oxygen and a reduced, deoxygenated metallic slag. A metal separation technique is still required to capture and purify metals from the deoxygenated slag for reuse in areas such as metallic part fabrication, structural or design frameworks, and metal catalyst production. The Marangoni Effect is best explained as mass transfer along an interface driven by surface tension gradients induced by temperature and concentration differences. Due to the temperature gradients, molten metal can be transported in this fashion to create thin films. This method can transport molten metal in the absence of gravity or mechanical motion and greatly increases the available surface area for a vacuum fractional separation process. In this study, a novel vacuum furnace induces the Marangoni Effect to fractionally decompose and separate valuable metals (e.g., aluminum) from thin films of molten metal via vacuum distillation. The proposed work will examine lunar regolith, metal-based recycling feedstocks, and metallic slags produced from the carbothermal reduction of regolith. Data and observations from this study could produce a simple yet effective method of refining lunar derived metals by taking advantage of the high vacuum environment present on the lunar surface.

ISRU↗

Distillation and Air Stripping Designs for the Lunar Surface

Air stripping and distillation are two different gravity-based methods, which may be applied to the purification of wastewater on the lunar base. These gravity-based solutions to water processing are robust physical separation techniques, which may be advantageous to many other techniques for their simplicity in design and operation. The two techniques can be used in conjunction with each other to obtain high purity water. The components and feed compositions for modeling waste water streams are presented in conjunction with the Aspen property system for traditional stage distillation models and air stripping models. While the individual components for each of the waste streams will vary naturally within certain bounds, an analog model for waste water processing is suggested based on typical concentration ranges for these components. Target purity levels for the for recycled water are determined for each individual component based on NASA s required maximum contaminant levels for potable water Distillation processes are modeled separately and in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Optimum parameters such as reflux ratio, feed stage location, and processing rates are determined with respect to the power consumption of the process. Multistage distillation is evaluated for components in wastewater to determine the minimum number of stages necessary for each of 65 components in humidity condensate and urine wastewater mixed streams. Components of the wastewater streams are ranked by Henry s Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support are presented. The advantages to the various designs are summarized with respect to water purity levels, power consumption, and processing rates.

Boul, Peter J.↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Digital Particle Image Velocimetry (DPIV) Used for Space-Time Correlations in Nozzle Flow

An optical measurement technique known as Digital Particle Image Velocimetry (DPIV) was used previously to characterize the first- and second-order statistical properties of both cold and hot jet flows from externally mixed nozzles in NASA Glenn Research Center's Nozzle Acoustic Test Rig. In this technique, an electronic camera records particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Correlation processing of the recorded particle image pairs yields the two-component velocity field across the imaged plane of the flow. The information acquired using DPIV is being used to improve our understanding of the decay of turbulence in jet flows-a critical element for understanding the acoustic properties of the flow. Recently, two independent DPIV systems were installed in Glenn's Small Hot Jet Acoustic Rig, enabling multiplane correlations in time and space. The data were collected over a range of different Mach numbers and temperature ratios. DPIV system 1 was fixed to a large traverse rig, and DPIV system 2 was mounted on a small traverse system mounted on the large traverse frame. The light sheets from the two DPIV systems were aligned to lie in the same axial plane, with DPIV system 2 being independently traversed downstream along the flow direction. For each measurement condition, the DPIV systems were started at a fully overlapping orientation. A polarization separation technique was used to avoid cross-talk between the two systems. Then, the DPIV systems fields were shifted axially apart, in successively increasing steps. The downstream DPIV system 2 was triggered at a short time delay after the upstream DPIV system 1, where the time delay was proportional to the convective flow velocity in the shear layer of the jet flow and the axial separation of the two DPIV systems. The acquired data were processed to obtain the instantaneous velocity vector maps over a range of time delays and spatial separations. The velocity fields from the different DPIV systems were then cross-correlated to determine the degree of correlation remaining in the flow as the downstream convection distance was increased. The new data provide Lagrangian measurements of the convective turbulent structures in the shear layer of an exhaust nozzle. These measurements, obtained in both cold and hot flows, will be used to validate and correct models for space-time velocity correlations-long a missing key to predicting jet noise.

Wernet, Mark P.↗

Effect of iodides on thermal behavior and phase partitioning in LiCl-KCl

Liquid-fueled molten salt reactors (MSRs) are designed to operate with fissile materials and, ultimately, fission products dissolved in the primary molten salt coolant. Understanding the speciation and transport of iodine—a high-yield fission product—is essential because this element’s accidental release poses significant environmental concerns due to its capacity to be readily absorbed by the human thyroid gland. Here, we report the impact of iodide species (LiI and KI) on phase transitions, phase distribution, and phase stability in LiCl–KCl-eutectic salt mixtures. The study employed a combination of computational and experimental techniques, including thermodynamic FactSage calculations, differential scanning calorimetry, and high-temperature X-ray diffraction. The results indicate that the presence of iodide (10–25 wt%) significantly alters the melting behavior of the LiCl–KCleutectic system. Adding 10 wt% LiI has a more-pronounced effect than 10 wt% KI, as LiI converts to KI, leading to formation of LiCl, thereby, altering the LiCl-KCl ratio which significantly affects the melting temperature of the mixture. Furthermore, the evolution of crystalline structure, solid-fraction composition, and the dynamics of mixed-halide solid–liquid partitioning as a function of temperature indicate the potential for selective iodide separation from chloride-salt mixtures via solid–liquid separation techniques. Overall, the presented findings provide valuable insights that are beneficial for the design and operation of MSRs, as well as for the safe handling and effective processing of used nuclear fuel using advanced pyrochemical techniques.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiplex coherent raman spectroscopy detector and method

A multiplex coherent Raman spectrometer (10) and spectroscopy method rapidly detects and identifies individual components of a chemical mixture separated by a separation technique, such as gas chromatography. The spectrometer (10) and method accurately identify a variety of compounds because they produce the entire gas phase vibrational Raman spectrum of the unknown gas. This is accomplished by tilting a Raman cell (20) to produce a high-intensity, backward-stimulated, coherent Raman beam of 683 nm, which drives a degenerate optical parametric oscillator (28) to produce a broadband beam of 1100-1700 nm covering a range of more than 3000 wavenumber. This broadband beam is combined with a narrowband beam of 532 nm having a bandwidth of 0.003 wavenumbers and focused into a heated windowless cell (38) that receives gases separated by a gas chromatograph (40). The Raman radiation scattered from these gases is filtered and sent to a monochromator (50) with multichannel detection.

Chen, Peter↗