Shear-Lag Tests of Two Box Beams with Flat Covers Loaded to Destruction
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This submission contains a report and associated data from triaxial direct shear tests conducted by Los Alamos National Laboratory. The samples used were sourced from 16A(78)-32 well core. The primary objectives of this test were to determine the shear strength in both intact and residual states, evaluate dilation against displacement, assess permeability in relation to displacement, time, and normal stress, understand the relationship between aperture and normal stress, and monitor the effluent chemistry as a function of time.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The static performances and failure characteristics of resistance spot welds (RSW) of steel sheets were studied in this work. Both similar and dissimilar joints of press-hardened steel grade 22MnB5 and as-rolled high-strength steel grade 1000 were examined. From metallographic analyses and micro-hardness measurements, it was shown that the microstructures of base metal (BM), heat affected zone (HAZ) and fusion zone of steel joints were noticeably different. In particular, the HAZ close to BM or subcritical HAZ (SCHAZ) of 22MnB5 steel exhibited greatly decreased hardness due to occurring tempered martensite, in which carbide precipitation was clearly observed. Furthermore, tensile shear test and cross-tension test of the welded steel sheets were carried out. The determined maximum loads, energy absorbability and corresponding failure mechanisms were analyzed and compared. The RSW samples of similar steel grade 1000 provided the highest load-carrying capacity and absorbed energy in both tests. Due to the large hardness difference and soft zone in weldment of dissimilar steel specimen, failure loads and static absorbed energies were deteriorated up to 17 and 68%, respectively. The observed fracture occurrences of all investigated joints were pullout failure mode, in which BM and HAZ were the crack initiation sites of grades 1000 steel and 22MnB5 steel, respectively. The SCHAZ of welded boron steel considerably caused the failure onset in tension shear test, but seemed to have negligible effect on cross-tension test.
The Iosipescu shear test method is used to measure the in-plane and interlaminar shear properties of four T300 graphite fabric/934 epoxy composite materials. Different weave geometries tested include an Oxford weave, a 5-harness satin weave, an 8-harness satin weave, and a plain weave with auxiliary warp yarns. Both orthogonal and quasi-isotropic layup laminates were tested. In-plane and interlaminar shear properties are obtained for laminates of all four fabric types. Overall, little difference in shear properties attributable to the fabric weave pattern is observed. The auxiliary warp material is significantly weaker and less stiff in interlaminar shear parallel to its fill direction. A conventional strain gage extensometer is modified to measure shear strains for use with the Iosipescu shear test. While preliminary results are encouraging, several design iterations failed to produce a reliable shear transducer prototype. Strain gages are still the most reliable shear strain transducers for use with this test method.
This memo’s objective is to report a calibration of the J2 plasticity model with the Wilkins ductile failure criterion for 17-4 PH H1150 stainless steel under slow loading at room temperature. The calibration of the hardening function was based on uniaxial tension tests, while that of the failure model included data from tension tests on notched specimens, a butterfly specimen shear test, and a set of interrupted compression tests on shear hat specimens. The procedure was that described in, minus the rate and temperature dependence.
Fluid flow through fractured media is typically governed by the distribution of fracture apertures, which are in turn governed by stress. Consequently, understanding subsurface stress is critical for understanding and predicting subsurface fluid flow. Although laboratory–scale studies have established a sensitive relationship between effective stress and bulk electrical conductivity in crystalline rock, that relationship has not been extensively leveraged to monitor stress evolution at the field scale using electrical or electromagnetic geophysical monitoring approaches. In this paper we demonstrate the use time–lapse 3–dimensional (4D) electrical resistivity tomography to image perturbations in the stress field generated by pressurized borehole packers deployed during shear–stimulation attempts in a 1.25 km deep metamorphic crystalline rock formation.
Highlights: • The δ-Cu{sub 41}Sn{sub 11} could be formed by reaction of 11Cu{sub 3}Sn + 9Cu → Cu{sub 41}Sn{sub 11} during aging above 350 °C. • The temperature effects on the growth rate and grain morphology of Cu{sub 41}Sn{sub 11} phase were found. • The Cu{sub 41}Sn{sub 11} joints with refined grains exhibited higher hardness and shear strength. • The Cu{sub 41}Sn{sub 11} joints exhibited a combination of transgranular and intergranular fracture during shear test. - Abstract: In this work, the aging treatment was carried out on full Cu{sub 3}Sn joints at different temperatures for various durations, the microstructure evolution, grain morphology variation and mechanical property change of joints were investigated. The temperature effects on the growth rate and grain morphology of Cu{sub 41}Sn{sub 11} phase were found: The complete transformation from Cu{sub 3}Sn phase to Cu{sub 41}Sn{sub 11} phase in joints needed 300 h at 400 °C, but 4 h at 500 °C. The Cu{sub 41}Sn{sub 11} phase formed at 400 °C consisted of columnar grains with an average width of 23.5 μm, while the Cu{sub 41}Sn{sub 11} phase formed at 500 °C consisted columnar grains with an average width of 8.5 μm. The average hardness and shear strength values of the Cu{sub 41}Sn{sub 11} joints formed at 400 °C were 432.5 HV and 62 MPa, while the joints formed at 500 °C exhibited higher hardness and shear strength (451.5 HV and 65 MPa). Besides, the Cu{sub 41}Sn{sub 11} joint was found to exhibit a combination of transgranular and intergranular fracture during shear test.
A new solid-phase technique called friction stir dovetailing (FSD) has been developed for joining thick section aluminum to steel. In FSD, mechanical interlocks are formed at the aluminum-steel interface and are reinforced by metallurgical bonds where intermetallic growth has been uniquely suppressed. Lap shear testing shows superior strength and extension at failure compared to popular friction stir approaches where metallurgical bonding is the only joining mechanism. High resolution microscopy revealed the presence of a 40-70 nm interlayer having a composition of 76.4 at% Al, 18.4 at% Fe, and 5.2 at% Si, suggestive of limited FeAl3 intermetallic formation.
Continuous feeding, processing, and handling of biomass powders is pivotal to the economic viability of integrated biorefineries. However, current challenges associated with the operational reliability of bulk solids handling and transport greatly impact the process economics and ultimately the widespread commercialization of integrated biorefineries. In this work, we examine the effect of moisture and feedstock variability on the flow behavior of corn stover biomass particles. The total flow energy, compressibility, shear properties, and wall friction angles were measured for corn stover samples A and B containing 0%, 15%, 25%, 50%, and 75% (mass fraction) moisture contents using a FT4 powder rheometer. In general, the flowability of both A and B was reduced when moisture was present as indicated by the stability and variable flow rate, compressibility, and shear tests. The 15% moisture sample had the highest flow energy, revealing the interplay between the increased surface tension and looser packing both of which were caused by liquid bridging. The 75% moisture sample had the highest compressibility and the lowest flowability factor (ff c ). The trend in wall friction angle was found to be dependent upon the surface hydrophobicity of the wall material. The wall friction angle on the hydrophilic, stainless-steel surface increased with moisture and therefore poses additional handling challenges. On the other hand, the wall friction angle on the hydrophobic polymer surfaces were the lowest for samples with intermediate moisture contents. Sample B had greater bulk density, smaller compressibility, and greater flowability than the sample A , as suggested by the compressibility and shear tests. The wall friction angle of sample B was higher than or equal to that of sample A depending on both the type and the surface roughness of the wall material.
Joining soft polymers and metals is receiving increasing attention in both industry and academia to enable the manufacturing of innovative products. One motivation arises from the production of next-generation heat exchanges, the structure of which is primarily composed of polymers and metals. Waste heat coming from low temperature exhaust gas stream is significant in industries in the U.S. However, traditional heat exchangers that are available to recover heat in the presence of small temperature difference are large and costly, restricting the wide application of such heat exchangers. To address this challenge, a hybrid materials design is proposed to achieve a balance between thermal conductivity and mechanical strength. High quality requirement induced by the changing operating conditions necessitates a strong bonding between polymers and copper. In this research, the possibility of using ultrasonic welding, which is conventionally employed to join dissimilar or similar metal layers, is explored. Preliminary results from welding experiments and tensile shear tests reveal that two bonding modes exist in the welding of PET and copper. Furthermore, analysis of power signals collected during welding shows that one can potentially monitor and optimize welding processes using monitoring signals. It is concluded from this study that ultrasonic welding has excellent potential in joining soft polymers and metals. Future work is also discussed on the process improvement and mechanism investigation.
Not Available
Epoxy/Kevlar composites have been manufactured by conventional Vacuum Infusion process and the Pulse Infusion technique. Pulse Infusion allows to control the pressure of the vacuum bag on the dry fiber reinforcement by using a proper designed pressure distributor that induces a pulsed transverse action and promotes the through thickness resin flow. The realized composite panel have been mechanically characterized by performing tensile and short beam shear tests according with the ASTM D3039 and ASTM D2344/D 2344M standard respectively in order to investigate the effect of Pulse Infusion on the tensile strength and ILSS.
Engineering robust adhesion of the junction box (j-box) is a hurdle typically encountered by photovoltaic module manufacturers during product development and manufacturing process control. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp-heat,' 'thermal-cycle,' or 'creep' tests within the IEC qualification protocol is proposed to verify the basic robustness of the adhesion system. The details of the proposed test are described, in addition to a trial-run of the test procedure. The described experiments examine four moisture-cured silicones, four foam tapes, and a hot-melt adhesive used in conjunction with glass, KPE, THV, and TPE substrates. For the purpose of validating the experiment, j-boxes were adhered to a substrate, loaded with a prescribed weight, and then subjected to aging. The replicate mock-modules were aged in an environmental chamber (at 85 degrees C/85% relative humidity for 1000 hours; then 100 degrees C/<10% relative humidity for 200 hours) or fielded in Golden (CO), Miami (FL), and Phoenix (AZ) for one year. Attachment strength tests, including pluck and shear test geometries, were also performed on smaller component specimens.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.